• 제목/요약/키워드: measurement of color

검색결과 891건 처리시간 0.031초

A Method for Quantitative Measurement of Lateral Flow Immunoassay Using Color Camera (컬러 카메라를 이용한 측면유동 면역 어세이 정량분석 방법)

  • Park, Jongwon
    • Journal of Biomedical Engineering Research
    • /
    • 제35권1호
    • /
    • pp.1-7
    • /
    • 2014
  • Among semi-quantitative or fully quantitative lateral flow assay readers, an image sensor-based instrument has been widely used because of its simple setup, cheap sensor price, and compact equipment size. For all previous approaches, monochrome CCD or CMOS cameras were used for lateral flow assay imaging in which the overall intensities of all colors were taken into consideration to estimate the analyte content, although the analyte related color information is only limited to a narrow wavelength range. In the present work, we introduced a color CCD camera as a sensor and a color decomposition method to improve the sensitivity of the quantitative biosensor system which utilizes the lateral flow assay successfully. The proposed setup and image processing method were applied to achieve the quantification of imitatively dispensed particles on the surface of a porous membrane first, and the measurement result was then compared with that using a monochrome CCD. The compensation method was proposed in different illumination conditions. Eventually, the color decomposition method was introduced to the commercially available lateral flow immunochromatographic assay for the diagnosis of myocardial infarction. The measurement sensitivity utilizing the color image sensor is significantly improved since the slopes of the linear curve fit are enhanced from 0.0026 to 0.0040 and from 0.0802 to 0.1141 for myoglobin and creatine kinase (CK)-MB detection, respectively.

Confocal Scanning Microscopy with Multiple Optical Probes for High Speed 3D Measurements and Color Imaging (고속 3차원 측정 및 칼라 이미징을 위한 다중 광탐침 공초점 주사 현미경)

  • Chun, Wan-Hee;Lee, Seung-Woo;Ahn, Jin-Woo;Gweon, Dae-Gab
    • Journal of the Semiconductor & Display Technology
    • /
    • 제7권1호
    • /
    • pp.11-16
    • /
    • 2008
  • Confocal scanning microscopy is a widely used technique for three dimensional measurements because it is characterized by high resolution, high SNR and depth discrimination. Generally an image is generated by moving one optical probe that satisfies the confocal condition on the specimen. Measurement speed is limited by movement speed of the optical probe; scanning speed. To improve measurement speed we increase the number of optical probes. Specimen region to scan is divided by optical probes. Multi-point information each optical probe points to can be obtained simultaneously. Therefore image acquisition speed is increased in proportion to the number of optical probes. And multiple optical probes from red, green and blue laser sources can be used for color imaging and image quality, i.e., contrast, is improved by adding color information by this way. To conclude, this technique contributes to the improvement of measurement speed and image quality.

  • PDF

Color accuracy of imaging using color filters

  • Boher, P.;Leroux, T.;Patton, V. Collomb;Bignon, T.
    • Journal of Information Display
    • /
    • 제13권1호
    • /
    • pp.7-16
    • /
    • 2012
  • In this paper, the problem concerning the color accuracy of imaging systems using color filters is examined. It is shown that the only solution to the problem is to build systems with the spectral response matching the CIE curves as closely as possible. If the spectral response does not closely match the CIE curves, it was demonstrated that calibration cannot solve the problem and will result in very unstable colorimeters. A practical solution that uses telecentric lenses on the sensor side in addition to dedicated color filters for each CCD detector is presented. For systems that closely match the CIE curves, an innovative method of improving the color accuracy based on the precise measurement of the spectral response is presented. The small discrepancies in the spectral response with regard to the CIE curves are corrected in different ways during the measurements. Finally, it is shown that the tristimulus calibration that is used for display measurement is very unstable for systems without CIE matching and is much more stable with systems that closely match the CIE curves.

A study on improvement of convergent measurement performance of color display tube using photo sensors (포토 센서를 이용한 브라운관의 컨버젼스 측정 성능 향상에 관한 연구)

  • ;;Zeungnam Bien
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • 제35S권3호
    • /
    • pp.93-101
    • /
    • 1998
  • In Integrated Tube Components(ITC) process in themanufacturing of color display tube, we describe the necessity of the convergence measurement method using photo sensors. Compared with methods using 1D or 2D cameras, its characteristics is to use of moving image patterns and fixed sensors. This measurement method is formulated as the measurement problem of the phase difference in phase changing periodic signals. The convergence measurement system using photo sensors, for the good performance, must have a small standard deviation for the repetitive measurement in the same condition and a fast measurement time for thecovergence change. By above two conditions, we proposed the real time measurement algorithm of the pahse difference using fundametal and harmonic in phase changing periodic signals. And, the proposed algorithm is applied to the convergence measurement system.

  • PDF

Relationship between Soil Color Characteristics and Measurement Values by Colorimeter (토양의 색 특성과 색차계 측정치의 상호관계)

  • Kim, Ki-In;Hong, Soon-Dal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • 제35권2호
    • /
    • pp.77-86
    • /
    • 2002
  • Soil color characteristics were measured by a optical instrument, colorimeter, comparing with the conventional Munsell color chart and related to the chemical properties of soils. Total of the 67 experimental soils were taken from tobacco fields that located at Cheongwon, Enmseong, Boeun, Goesan, Jincheon, and Chungju countries in Chungbuk Province having the 29 soil series including Samgag. The values of L, a, and b measured by colorimeter were closely related with hue, value, and chroma of Munsell color chart, respectively, indicating the quantitative measurement of soil color characteristics. The standard deviations in measurement for L, a, and b values was smaller in soil sample passed by 0.5 mm sieve than 2 mm sieve, suggesting that soil particle size less than 0.5 mm was better condition for colorimeter measurement. The values of L and b measured by colorimeter showed a tendency to decrease as increase of soil moisture content but nearly on difference with moisture condition for the value of a. However, correlation coefficient between air dry samples and wet soil samples(soil moisture retension of -10 hPa) for measurements of L, a and b value were more than 0.9 showing the same tendency in measurement. Consequently, air dry soil passed by 0.5 mm sieve was recommended to desirable conditions for stable measurement by colorimeter. The measured values by colorimeter were significantly correlated with organic matter, CEC, exchangeable Ca and Mg, showing the highest correlation coefficient between L value and organic matter.

Quality Characteristics of Pan Bread Added with Color Barley Powder (유색보리 분말을 첨가한 식빵의 품질특성)

  • Jeong, Hyun-Chul;Yoo, Seung-Seok
    • Culinary science and hospitality research
    • /
    • 제20권4호
    • /
    • pp.127-143
    • /
    • 2014
  • This study investigated color barley powder substituted for wheat flour in bread recipes with the amounts of 0%, 5%, 10%, 15% and 20%. Color barley powder consisted of 9.35% of moisture content, 9.37% of crude protein, 1.64% of crude fat and 2.96% of crude ash. Water soluble dietary fiber is 3.21, insoluble dietary fiber is 4.91, total dietary fiber content is 8.12, and ${\beta}$-glucan is 49.31. DPPH radical scavenging activity is 56.76%, total phenol content is 234.34. The farinograph measurement result of the bread made with color barley powder showed that consistency, water absorption, development time and time breakdown have decreased. The alveogram measurement result of the bread made with color barley powder showed that overpressure, extensibility, swelling index and deformation energy have increased. The amylograph measurement result of the bread made with color barley powder showed that peak viscosity, hot past viscosity and breakdown have decreased. Baking loss and specific loaf volume have decreased as the color barley powder content increased. The chromaticity measurement result showed that the 'L' and 'b' of bread have increased as the color barley powder content increased, while the chromatic 'a' value increased. The texture measurement result showed that the hardness and gumminess of bread have increased as the color barley powder content increased. cohesiveness, springiness and chewiness have decreased. Overall preference scores showed a high overall acceptability for the bread made with 10% color barley powder.

A study on the Modification of Fastness Formulae and the Measurement of Staining Fastness by CCM

  • Park, Ju-Young;Hong, Min-Gi;Lee, Nan-Hyeng;Kim, Sam-Soo;Hudson Samuel M.;Park, Sung-Su
    • Textile Coloration and Finishing
    • /
    • 제18권5호
    • /
    • pp.80-87
    • /
    • 2006
  • A new fastness formula based on the CIEDE2000 color-difference formula was developed by B. Rigg and his coworkers. It is much simpler to calculate the staining fastness grade than the ISO 105-A04 fastness formula based on the CIELAB color-difference formula. Sample pair sets, which cover a wide color space range were accumulated from the NCS(Natural Color System) color book. for those sample pair sets, a visual measurement experiment and an instrumental measurement experiment of fastness grade were carried out. Each performance of the ISO 105-A43 fastness formula and newly developed fastness formula was compared through degree of agreement for visual measurement results. The newly developed fastness formula indicated improved performance for measuring fastness grade as it was confirmed that the performance of the current ISO fastness formula ISO 105-A04 for assessing staining, was inadequate for measuring fastness grade. Then the fastness formulae were examined more closely according to the particular color spaces and the correlation of hue, lightness and chroma for measuring staining fastness grade was also considered to recommend more improved fastness formula. By modifying the weighting functions of CIEDE2000, which is a basis of new fastness formula developed by B. Rigg, a modified fastness formula is proposed in this study.

Testing the Reliability of the Pain Color Circle Measurement Tool (색채동통척도의 신뢰도 연구)

  • 김주희
    • Journal of Korean Academy of Nursing
    • /
    • 제21권3호
    • /
    • pp.339-348
    • /
    • 1991
  • The study problem was to determine the reliability of the Stewart pain circle measurement tool with Korean subjects. The purpose was to assess the tool for potential use in research in Korea. The subjects were 95 primary school students and 103 university students in Seoul. The study was conducted from May to June 1990, using Stewart's pain color circle tool. To determine the difference in the rated intensity of the order of the pain color circles, statistical mean and standard deviation were employed. Item reliability and test - retest reliability were used to test for reliability. ANOVA and t-test were used to explore for differences in the rated intensity of the order of the pain color circles according to the subjects' general characteristics. The findings were as follows ; 1. Higher level pain intensity was assigned to color circle numbers 2, 4, and 6 (These contain large amounts of color). Lower level pain intensity was assigned to numbers 1, 3, and 5(These contain small amounts of color). Higher and lower levels of pain intensity selection patterns were the same as Stewart's but the highest rating of pain was different. The highest pain intensity rating was given to the color red in this study instead of black as in Stewart's test. 2. University students and primary school students' ratings were not very difteferent. 3. Pain color circle reliability was $\alpha$=0.3468, Test - retest reliability was supported (t=0.02~0.97, p=0.337~0.988) 4. Differences in the rating of the pain intensity order were related to the subjects' age and sex, but not to religion. It was concluded that the pain color circle measurement tool is worth for further study as a research instrument with both Korean adult and child clients for validity and reliability.

  • PDF

POLYGONIOSCOPE a new instrument for fastest luminance, color and viewing angle measurement with highest accuracy

  • Laur, Juergen
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1370-1373
    • /
    • 2008
  • This paper introduces a novel display measuring instrument that allows accurate, spectro-radiometric measurement of the complete viewing cone while the measuring time is similar to that of a CCD camera with transform lens optics. Actually the new instrument, named POLYGONIOSCOPE, is orders of magnitude faster compared to a conventional spot spectrometer.

  • PDF

Quantization and Calibration of Color Information From Machine Vision System for Beef Color Grading (소고기 육색 등급 자동 판정을 위한 기계시각 시스템의 칼라 보정 및 정량화)

  • Kim, Jung-Hee;Choi, Sun;Han, Na-Young;Ko, Myung-Jin;Cho, Sung-Ho;Hwang, Heon
    • Journal of Biosystems Engineering
    • /
    • 제32권3호
    • /
    • pp.160-165
    • /
    • 2007
  • This study was conducted to evaluate beef using a color machine vision system. The machine vision system has an advantage to measure larger area than a colorimeter and also could measure other quality factors like distribution of fats. However, the machine vision measurement is affected by system components. To measure the beef color with the machine vision system, the effect of color balancing control was tested and calibration model was developed. Neural network for color calibration which learned reference color patches showed a high correlation with colorimeter in L*a*b* coordinates and had an adaptability at various measurement environments. The trained network showed a very high correlation with the colorimeter when measuring beef color.