• Title/Summary/Keyword: measurement extraction

Search Result 576, Processing Time 0.03 seconds

Consideration of Appropriate Thermal Storage Time of Air-Conditioning System with Slab Thermal Storage in an Office Building by Use of Measurement Value (실측치를 통한 사무소건물 슬래브축열 공조시스템의 적정 축열시간 검토)

  • Jung, Jae-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.10
    • /
    • pp.719-726
    • /
    • 2010
  • In this paper, the appropriate thermal storage time of an air-conditioning system with slab thermal storage was considered by use of summer measurement values. Two standards of heat extraction rate and criterion function were established as the standard that evaluates appropriateness. When heat extraction rate was a standard, zero hour and seven hours were obtained as appropriate thermal storage time, in the case of evaluation by energy consumption and running cost individually. Also, when criterion function was a standard, the difference between energy consumption and running cost was small, it was because the weight function to room air temperature deviation was much bigger than heat extraction rate.

Automatic Extraction and Measurement of Visual Features of Mushroom (Lentinus edodes L.) (표고 외관 특징점의 자동 추출 및 측정)

  • Hwang, Heon;Lee, Yong-Guk
    • Journal of Bio-Environment Control
    • /
    • v.1 no.1
    • /
    • pp.37-51
    • /
    • 1992
  • Quantizing and extracting visual features of mushroom(Lentinus edodes L.) are crucial to the sorting and grading automation, the growth state measurement, and the dried performance indexing. A computer image processing system was utilized for the extraction and measurement of visual features of front and back sides of the mushroom. The image processing system is composed of the IBM PC compatible 386DK, ITEX PCVISION Plus frame grabber, B/W CCD camera, VGA color graphic monitor, and image output RGB monitor. In this paper, an automatic thresholding algorithm was developed to yield the segmented binary image representing skin states of the front and back sides. An eight directional Freeman's chain coding was modified to solve the edge disconnectivity by gradually expanding the mask size of 3$\times$3 to 9$\times$9. A real scaled geometric quantity of the object was directly extracted from the 8-directional chain element. The external shape of the mushroom was analyzed and converted to the quantitative feature patterns. Efficient algorithms for the extraction of the selected feature patterns and the recognition of the front and back side were developed. The developed algorithms were coded in a menu driven way using MS_C language Ver.6.0, PC VISION PLUS library fuctions, and VGA graphic functions.

  • PDF

Three‐Dimensional Automatic Measurement Extraction Algorithms for Neck‐base Part of Females in Their Twenties (20대 여성의 목밑둘레 부위에 대한 3차원 자동 측정 알고리즘)

  • Hwang, Keun-Young;Nam, Yun-Ja;Park, Jae-Kyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.35-43
    • /
    • 2005
  • The purpose of this study is to suggest computer assisted neck-base's landmark identification algorithms and measurement extraction methods from three-dimensional human scan data. So we developed the algorithms for automatic identification of landmarks related to the neck-base types. The subjects were 58 women $18{\sim}24$ years of age. Their body were measured directly and indirectly by using camera and three-dimensional body scanner. They were measured during the months of October in 2001. Based on the characters of classified neck-base types, algorithms for the automatic identification of landmarks and methods of automatic measurement are developed. The three-dimensional automatic measuring program is made by $C^{++}$ language. Using this program, 4 landmarks are identified and 6 items are measured. In the verifying the precision of automatic measurement, the height measurements(cervicale, side neck point, front neck point) were relatively accurate, but neck-base width measurement was measured wide.

Digital image processing techniques of digital holographic PTV measurement (디지털 holographic PTV 측정을 위한 디지털 영상처리기법에 관한 연구)

  • Kim, Seok;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.1-5
    • /
    • 2005
  • The digital HPTV velocity field measurement consists of four steps: recording, numerical reconstruction, particle extraction and velocity extraction. In the velocity extraction process, we improved PTV algorithm to extract the displacement of particle each placed in 3D space. Because a digital recording device was used, some factors such as a spatial resolution, numerical aperture, and particle concentration can affect the performance of the digital HPTV. Especially, a particle concentration ($C_{o}$) affected tile reconstruction efficiency in numerical reconstruction and particle extraction process. In this paper, the reconstruction efficiency was analyzed experimentally with different particle concentration. Optimal reconstruction efficiency was shown in the range of $C_{o}$=$13\∼15$ particles/$mm^{3}$.

  • PDF

Effect of Particle Concentration on Digital Holographic PTV Measurement (입자 농도가 Digital Holographic PTV 측정에 미치는 영향에 관한 연구)

  • Kim Seok;Lee Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.10 s.253
    • /
    • pp.929-934
    • /
    • 2006
  • The digital HPTV(holographic particle tracking velocimetry) velocity field measurement system consists of four steps: recording, numerical reconstruction, particle extraction and velocity extraction. In the velocity extraction process, we improved the two frame PTV algorithm to extract 3-D displacement information of each particle located in 3D space. Because a digital CCD camera was used, some factors such as spatial resolution, numerical aperture, and particle concentration influenced on the performance of the developed digital HPTV. Especially, the particle concentration $(C_o)$ affected the reconstruction efficiency and recovery ratio in the numerical reconstruction and particle extraction procedure. In this paper, the effect of particle concentration reconstruction efficiency and recovery ratio were analyzed experimentally. Optimal particle concentration was found to be in the range of $C_o=11{\sim}17\;particles/mm^3$.

A Study on Desorption Efficiency of PAHs according to Desorption Solvents by HPLC with Sonication Extraction (탈착용매에 따른 PAHs 흡착매체의 탈착효율 평가 연구)

  • Hong, Jwa-ryung;Lee, Ji-eun;Jung, Myung-Koo;Choi, Kwang-min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.307-316
    • /
    • 2016
  • Objectives: In general, NIOSH method 5506 is most widely used for the occupational exposure measurement of PAHs, but 2-4 ring PAHs have poor desorption efficiency, especially for a filter. The purpose of this study was to determine a method to increase the desorption efficiency of 16-PAHs using an ultrasonic extraction procedure. Methods: Test samples prepared spiked XAD-2 tubes and PTFE filters in the range of $0.01-1.0{\mu}g/mL$ for desorption efficiency study. Four different extraction solvents, acetonitrile, acetone, tetrahydrofuran and dichloromethane, were tested in order to select the most suitable solvent for the extraction of the 16 PAHs. The addition of dimethyl sulfoxide and sonication time were considered in order to determine the method with the highest extraction efficiency. All samples were made in three sets and analysis was replicated seven times by HPLC. Results: Acetonitrile and acetone were the optimized as an extraction solvent and desorption efficiency of 2-ring PAHs such as naphthalene, acenaphthylene were increased 3~19% with dimethyl sulfoxide for XAD-2. Acetone was the best extraction solvent for PTFE filter and the desorption efficiency was increased 3~13% for 2- to 4-ring PAHs. The optimum sonication time was 60 minutes and desorption efficiency increased with extraction time. Conclusions: As a result, the best extraction solvent was acetone with dimethyl sulfoxide for ultrasonic extraction procedure and the desorption efficiency of this method was better than NIOSH 5506's. This study could be applied as a method for occupational exposure measurement of PAHs.

Robust Extraction of Heartbeat Signals from Mobile Facial Videos (모바일 얼굴 비디오로부터 심박 신호의 강건한 추출)

  • Lomaliza, Jean-Pierre;Park, Hanhoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.1
    • /
    • pp.51-56
    • /
    • 2019
  • This paper proposes an improved heartbeat signal extraction method for ballistocardiography(BCG)-based heart-rate measurement on mobile environment. First, from a mobile facial video, a handshake-free head motion signal is extracted by tracking facial features and background features at the same time. Then, a novel signal periodicity computation method is proposed to accurately separate out the heartbeat signal from the head motion signal. The proposed method could robustly extract heartbeat signals from mobile facial videos, and enabled more accurate heart rate measurement (measurement errors were reduced by 3-4 bpm) compared to the existing method.

A study of activity ratios of uranium isotope in the groundwater using liquid scintillation counter (액체섬광계수기를 이용한 지하수 내 우라늄 동위원소 측정법에 관한 연구)

  • Cho, Soo-Young;Song, Kyung-Sun;Lee, Kil-Yong;Yoon, Yoon-Yeol;Kim, Won-Baek;Ko, Kyung-Sok
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.146-151
    • /
    • 2012
  • An analytical method was developed for the measurement of uranium isotope in ground water using the liquid scintillation counting technique. A LKB Wallac Quantulus 1220 liquid scintillation counter (LSC) equipped with pulse shape analyzer (PSA) and a solvent extraction method were used for the measurement of uranium isotope in ground water samples. The effect of solution volume on the extraction efficiency was evaluated for 100 to 1000 mL solutions using a NIST standard reference material (NIST SRM 4321C). The effect of groundwater pH on the extraction efficiency was also investigated for pH ranging from 0.5 to 10. It was found that the extraction efficiency had a strong dependence on pH showing a maximum at pH 2. In contrast, the effect of groundwater volume on the extraction efficiency was negligible in the range investigated. According to the method, the extraction efficiency of uranium isotopes was near 96% and the lower detection limit for uranium was 0.018 Bq/L with the counting time of 300 min. The result of this study was also verified by the conventional ICP-MS measurement. It is demonstrated that the suggested method is valuable to the determination of the optimum extraction and measurement conditions for uranium in ground water. The method was successfully applied to the ground water at four locations near the Daejeon province. It was found that the uranium content and the isotopic ratio of $^{234}U/^{238}U$ at the locations ranged 0.59~6.69 Bq/L and 0.72~1.40, respectively.

Complexing Capacity - A Measure of Evaluating Water Quality

  • Akaiwa, Hideo;Itabashi, Hideyuki
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.1089-1094
    • /
    • 1995
  • Methods for the measurement of copper(II) complexing capacity (CuCC) of natural waters by using the back-extraction of bis(benzoyl-trifluoroacetonate)copper(II) and the extraction rate of dithizonato-copper(II) complex were described. Experimental results show that the CuCC of the Kiryu river water samples from urban area were consistently larger than those from up-stream, due to a ligand which originated from human activities.

  • PDF

The Development of a Stereo vision algorithm for Height Measurement of Ball Peak Point of BGA Device (BGA 소자의 볼 정점 높이 측정을 위한 스테레오 비젼 알고리즘 개발)

  • Lee, Sang-Sin;Park, Young-Soon;Kim, Joon-Seek;Joo, Hyo-Nam
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.431-436
    • /
    • 2005
  • In this paper, We proposed the stereo image modeling using 2-dimensional images captured by the high resolution cameras to inspect the ball defects of BGA(Ball Grid Array) device. The proposed algorithm consists of the package/ball area extraction part, the FOV(Field of View) calibration part, the top point matching part, and ball height measurement part, In the package/ ball area extraction part, the package and ball areas are separately extracted in a left and right image by the extraction algerian. Through the experiment, we draw out the result.

  • PDF