• Title/Summary/Keyword: measured displacement

Search Result 1,719, Processing Time 0.032 seconds

Two Stage Kalman Filter based Dynamic Displacement Measurement System for Civil Infrastructures (이단계 칼만필터를 활용한 사회기반 건설구조물의 3자유도 동적변위 계측 시스템)

  • Chung, Junyeon;Choi, Jaemook;Kim, Kiyoung;Sohn, Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.3
    • /
    • pp.141-145
    • /
    • 2018
  • The paper presents a new dynamic displacement measurement system. The developed displacement measurement system consists of a sensor module, a base module and a computation module. The sensor module, which contains a force-balanced accelerometer and low-price RTK-GNSS, measures the high-precision acceleration with sampling frequency of 100Hz, the low-precision displacement and velocity with sampling frequency of 10Hz. The measured data is transferred to the computation module through LAN cable, and precise displacement is estimated in real-time with 100Hz sampling frequency through a two stage Kalman filter. The field test was conducted at San Francisco-Oaklmand Bay bridge, CA, USA to verify the precision of the developed system, and it showed the RMSE was 1.68mm.

THREE-DIMENSIONAL COMPARISON OF FRAMEWORK DISPLACEMENTS JOINED BY VARIOUS CONNECTION TECHNIQUES (연결방법에 따른 주조체 변위에 관한 3차원적 비교연구)

  • Lim, Jang-Seop;Jeon, Young-Chan;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.358-374
    • /
    • 1999
  • This study measured the relative displacements of the five-unit fixed partial dentures as cast with the same fixed partial dentures sectioned and assembled by investment-soldering, solder-ing stand-soldering, and cast-joining techniques A total of fifteen specimens using a type IV gold alloy were one-piece cast as control and then sectioned and assembled five test specimens for each method were prepared. A computerized three dimensional coordinate measuring machine and specially designed cylinder for this study were used. Displacement was defined by six displacement variables for the each of cylinders incorporated in each casting: three component displacements(${\Delta}Lx,\;{\Delta}Ly,\;and\;{\Delta}Lz$) and rotational displacements(${\Delta}{\theta}x,\;{\Delta}{\theta}y,\;{\Delta}{\theta}z$). The global displacement was computed using the mathematical formula ${\Delta}R$ = Global displacement =$\sqrt{{(x'-x)}^2+{(y'-y)}^2+{(z'-z)}^2}$ Under the conditions of this study, the following conclusions were drawn: 1. The investment-soldering group showed the largest mean value of final global displacements, followed by stand-soldering group, cast-joining group and one-piece cast group. However, between the mean values of final global displacement for the cast-joining group and one-piece cast group, there was no significant difference. 2. For investment-soldering and stand-soldering groups, the greater global displacements were recorded in soldering phase than in indexing or investing phase. 3. For one-piece cast group, the displacements occured mostly in the casting phase. And for cast-joining group, there was no significant difference in global displacements among the fabricating procedures. 4. Intercentroidal distance decreased in framework-patterning, solder-indexing, solder-standing, and soldering phases, but increased in investment block-investing and casting phases. 5 Specially designed cylinder for touch-trigger type coordinate measuring machine was validated.

  • PDF

The Study of Correlationship of the Fukuda Stepping Test to Determine Type of Idiopathic Scoliosis Curve (척주측만증 환자의 만곡과 후쿠다 검사의 상관성에 관한 연구)

  • Lee, Sang-Yeol;Jo, Marg-Eun;Ko, Min-Ji;Kim, Young-Ju;Lee, Seung-Min
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.2
    • /
    • pp.13-16
    • /
    • 2016
  • PURPOSE: The Fukuda test can be used at home and in school to diagnose scoliosis at an early stage and prevent serious curvature of the spine. This study aimed to use the Fukuda test to detect scoliosis. An additional aim was to invoke the national interest in imbalanced postures and habits, which result in scoliosis, by providing data obtained in periodic assessments. METHODS: The study consisted of 35 idiopathic scoliosis patients (22 in right lumbar spinal region and 13 in the left lumbar spinal region). The distance of displacement and angle of displacement were measured following the Fukuda test. A correlation analysis was then used to examine the distance of displacement and angles of displacement and rotation with regard to the direction of the curve in scoliosis. RESULTS: There was a significant negative correlation (p<0.00) between the direction of the curve in scoliosis and the angle of displacement, but there was no correlation between the cobb's angle and distance of displacement or between the cobb's angle and angle of rotation. CONCLUSION: The Fukuda test did not capture changes in spinal curvature such as the cobb's angle, or subsequent changes in the muscles. Thus, the Fukuda test is not suited to examining the direction or status of the thoracic curve in scoliosis patients. Simple methods to objectively measure scoliosis need to be developed.

Prediction of Ground Condition Changes Ahead of Tunnel Face Using Three-Dimensional Absolute Displacement Analysis (터널 3차원 절대변위 해석기법을 이용한 막장전방지반 예측)

  • Bang, Joon-Ho;Han, Il-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.2
    • /
    • pp.101-113
    • /
    • 2006
  • Arching effect occurs around the unsupported excavation surface near to tunnel face when a tunnel is excavated in a stable rock mass. If a weak fracture zone exists in front of tunnel face, a displacement occurs between tunnel face and weak fracture zone due to stress concentration. If three-dimensional absolute coordinates (longitudinal, transverse, vertical direction) is measured at tunnel face by geodetic method, the ground change in front of the tunnel face can be predicted by analysing three-dimensional absolute displacement. The purpose of this study is to verify the analysis method of three-dimensional absolute displacement by comparing the trend of displacement ratio at crown and sidewall of tunnel and the influence line/trend line of crown settlement compared with TSP results in the same section.

  • PDF

Study on characteristics of noncontact vibrating displacement sensor (비접촉식 진동 변위센서의 특성에 관한 연구)

  • Cho, C.W.;Cho, S.T.;Yang, K.H.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.13-18
    • /
    • 2011
  • This thesis is about the result of conducting a specific experiment for the development of noncontact vibration displacement sensor for measuring the spindle vibration that is used for conditional monitoring of machinery. One should be careful when using the eddy current type displacement sensor because the sensitivity of it is different according to the quality of the material. While the probe used for nondestructive inspection adopts the effect of transmitting the material by using the high frequency domain, the eddy current type displacement sensor uses the lower frequency of around 1MHz. Also, while the nondestructive probe uses the method of enhancing output by using the resonance zone, the vibration displacement sensor utilizes the stable zone by avoiding the resonance zone. Since the oscillator of the converter uses the "L" element as Probe, its characteristic changes with the variation of a relevant impedance. In other words, if the length of Probe's Cable gets extended (Impedance increase), the sensitivity declines accordingly. The effect of surrounding temperature was small, but the influence of the quality of Sensor Coil used was high. Moreover, following an experimental demonstration of the phenomenon where the sensitivity decreases as the frequency of the tested material increases from a frequency response test, the maximum frequency that could be measured was approximately 1KHz. It was noted that the degree of precision could be maintained by using the gap of the probe in the linear zone at the installation site.

The Analysis of Center of Pressure(COP) Displacement under Loading Position during Walking (보행 시 부하 위치에 따른 족저압 중심(COP) 이동 분석)

  • Park, Soo-Jin;Kim, Jin-Sang
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.1
    • /
    • pp.15-24
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the effect of loading position on plantar center of pressure(COP) displacement when carrying a schoolbag during walking. Methods : Forty-four normal subjects were randomly assigned to five groups according to the method of carrying a schoolbag. The carrying a schoolbag methods were classified into five conditions: no bag (condition 1), a backpack (condition 2), a shoulder bag (condition 3), a cross bag (condition 4), a one-hand bag (condition 5). COP displacement such as anteroposterior distance and mediolateral distance of COP were measured with F-scan system. The repeated one-way analysis of variance (ANOVA) and independent t-test were used to confirm the statistical significance. Results : In the comparison of parameters of COP displacement between conditions, anteroposterior distance and mediolateral distance in the left foot and mediolateral distance in the right foot were not significantly different(p>.05), but anteroposterior diatance in the right foot was significantly different(p>.05). Between left and right foot, at condition 1 and 5 the mediolateral distance of COP was significantly different(p<.05) but anteroposterior distance at condition 1 and 5, anteroposterior distance and mediolateral distance of COP at condition 2, 3 and 4 were not significantly different(p>.05). Conclusion : These findings showed that the various loading position by five types of carrying a schoolbag didn't have influence significantly on COP displacement on during walking because of mechanism of postural adaption.

A new model approach to predict the unloading rock slope displacement behavior based on monitoring data

  • Jiang, Ting;Shen, Zhenzhong;Yang, Meng;Xu, Liqun;Gan, Lei;Cui, Xinbo
    • Structural Engineering and Mechanics
    • /
    • v.67 no.2
    • /
    • pp.105-113
    • /
    • 2018
  • To improve the prediction accuracy of the strong-unloading rock slope performance and obtain the range of variation in the slope displacement, a new displacement time-series prediction model is proposed, called the fuzzy information granulation (FIG)-genetic algorithm (GA)-back propagation neural network (BPNN) model. Initially, a displacement time series is selected as the training samples of the prediction model on the basis of an analysis of the causes of the change in the slope behavior. Then, FIG is executed to partition the series and obtain the characteristic parameters of every partition. Furthermore, the later characteristic parameters are predicted by inputting the earlier characteristic parameters into the GA-BPNN model, where a GA is used to optimize the initial weights and thresholds of the BPNN; in the process, the numbers of input layer nodes, hidden layer nodes, and output layer nodes are determined by a trial method. Finally, the prediction model is evaluated by comparing the measured and predicted values. The model is applied to predict the displacement time series of a strong-unloading rock slope in a hydropower station. The engineering case shows that the FIG-GA-BPNN model can obtain more accurate predicted results and has high engineering application value.

Modified Tei index in patients with Kawasaki disease by tissue doppler imaging (가와사키병 환아에서 Tissue doppler imaging으로 측정한 modified Tei 지수)

  • Kim, Hee Jung;Cha, Jung Hwa;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.11
    • /
    • pp.1202-1210
    • /
    • 2006
  • Purpose : A quantitative and easily measured Doppler index of combined systolic and diastolic ventricular myocardial performance (Tei index) was recently proposed as a potentially useful predictor of global myocardial performance. However, presence of heart rate fluctuation makes it unreliable. Therefore, the modified Tei index was introduced by using tissue Doppler imaging (TDI) which enables measuring contraction and relaxation velocities from myocardium simultaneously. The purpose of this study was to investigate the effectiveness of the modified Tei index in the evaluation of global cardiac function. Methods : Forty eight patients in the acute phase of Kawasaki disease (KD) were studied. These patients were divided into two groups according to the modified Tei index. TDI and conventional echocardiography were performed. Systolic velocity, systolic displacement, E' velocity, E' displacement, A' velocity and A' displacement were measured at the base, mid-septum and the apex of the interventricular septum. Ejection fraction (EF), Tei index and modified Tei index were estimated. Results : Modified Tei index correlated negatively with systolic displacement, E' displacement and A' displacement at the base. Modified Tei index correlated positively with ESR and CRP. EF and Tei index were normal in KD patients. Conclusion : Modified Tei index is a safe, feasible and sensitive index for evaluating global ventricular functions in spite of normal EF and Tei index in KD.

Characterization of Ceramic Membranes by Gas-Liquid Displacement Porometer and Liquid-Liquid Displacement Porometer (Gas-Liquid Displacement Porometer와 Liquid-Liquid Displacement Porometer를 이용한 세라믹 분리막 특성 분석)

  • Kim, Yeo-Jin;Kim, Seong-Joong;Kim, Jeong;Jo, Yeong-Hoon;Park, Hosik;Lee, Pyung-Soo;Park, You-In;Park, Ho-Bum;Nam, Seung-Eun
    • Membrane Journal
    • /
    • v.27 no.3
    • /
    • pp.263-272
    • /
    • 2017
  • There are several different methods to characterize membrane pore size distribution, however, it is yet difficult to accurately measure pore size range of 10-50 nm. In this work, we employed gas-liquid displacement porometer (GLDP) and liquid-liquid displacement porometer (LLDP) to characterize in-house alumina hollow fiber membrane (K-100) and commercial membranes (A-100, A-20) that exhibit pore sizes between 10-100 nm. GLDP method was more suitable for measuring the maximum pore size, and the measured mean pore size of the membranes by LLDP were better correlated with water permeability and solute rejection. It was determined that LLDP is effective for measuring pore sizes between 10-50 nm; however, the method holds intrinsic disadvantages such as low precision and high sensitivity compared to that of GLDP. Nevertheless, it is expected that the recently commercialized LLDP technique can provide useful data that other methods cannot.

Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation (요골동맥 직경 변화에 따른 맥파 측정 시스템 개발)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.