• Title/Summary/Keyword: measure of size

Search Result 2,037, Processing Time 0.043 seconds

Application of Stereo Vision for Shape Measurement of Free-form Surface using Shape-from-shading (자유곡면의 형상 측정에서 shape-from-shading을 접목한 스테레오 비전의 적용)

  • Yang, Young-Soo;Bae, Kang-Yul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.5
    • /
    • pp.134-140
    • /
    • 2017
  • Shape-from-shading (SFS) or stereo vision algorithms can be utilized to measure the shape of an object with imaging techniques for effective sensing in non-contact measurements. SFS algorithms could reconstruct the 3D information from a 2D image data, offering relatively comprehensive information. Meanwhile, a stereo vision algorithm needs several feature points or lines to extract 3D information from two 2D images. However, to measure the size of an object with a freeform surface, the two algorithms need some additional information, such as boundary conditions and grids, respectively. In this study, a stereo vision scheme using the depth information obtained by shape-from-shading as patterns was proposed to measure the size of an object with a freeform surface. The feasibility of the scheme was proved with an experiment where the images of an object were acquired by a CCD camera at two positions, then processed by SFS, and finally by stereo matching. The experimental results revealed that the proposed scheme could recognize the size and shape of freeform surface fairly well.

A Comparison of PPS and Simple Cluster Sampling in Large Scale Sampling -Based on Economically Active Population Survey Sample Design (대규모 표본설계에서 확률비례 및 단순집락추출법 비교 -경제활동인구 표본조사 사례를 중심으로-)

  • 윤연옥;이상은
    • The Korean Journal of Applied Statistics
    • /
    • v.14 no.1
    • /
    • pp.1-11
    • /
    • 2001
  • In PPS sampling, measure of size(MOS) is used to determine the probability of selection of sampling unit. However, some large scale surveys conducted in NSO(National Statistical Office) showed that the sampling units have the similar MOS. In such case, simple cluster sampling method instead of PPS sampling is recommended to give the interviewers a similar work load. In this paper, MSE and CV of the above two sampling methods applied to the 1997 Economically Active Population Survey sample design are compared.

  • PDF

The change of pupil size after viewing three dimensional TV (2안식 입체TV 주시전후의 동공면적의 변화)

  • Cho, Am
    • Proceedings of the ESK Conference
    • /
    • 1995.04a
    • /
    • pp.187-198
    • /
    • 1995
  • The physiological change of eyes while viewing 3D TV was investigated. The change of pupil size was used as the measure of evaluation. The results are as follows: (1) The pupil size decreases after viewing 3D images. (2) The indoor illumination has a significant effect on the pupil size in both 2D and 3D cases. (3) Less change of pupil size were observed under the indoor illumination. Thus, if we only focus on the visual load on the eye, for viewing 3D images, it will be better to use indoor illumination.

  • PDF

Development of a Method to Measure Droplet Size and Spray Deposition Using Computer Vision (컴퓨터 시각에 의한 분무입자 크기와 분무량 측정법 개발)

  • Suh, S.R.;Kim, T.H.;Sung, J.H.;Chung, J.H.;Yoo, S.N.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.4
    • /
    • pp.369-379
    • /
    • 1994
  • A computer vision system consisted of a microscope, a CCD camera, a frame grabber and a personal computer was used to analyze spraying pattern. An algorithm was developed for the system to measure size of droplets including overlapped droplets, to count number of droplets, and to estimate spray deposition in a certain area from the data obtained. A series of experiment was carried out to test validity of the algorithm. The experiment resulted that accuracy of the droplet size measurement, accuracy of counting the number of droplets and the estimation of spray deposition were within an acceptable range. It was concluded from the results that the computer vision system operated by the developed algorithm is very useful tool to analyze spraying pattern.

  • PDF

Liquidity and Solvency Management and its Impact on Financial Performance: Empirical Evidence from Jordan

  • DAHIYAT, Ahmad Abdelrahim;WESHAH, Sulaiman Raji;ALDAHIYAT, Mohammad
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.5
    • /
    • pp.135-141
    • /
    • 2021
  • The study aims to examine the impact of liquidity and solvency management on the financial performance of Jordanian manufacturing companies listed on the Amman Stock Exchange, for a period of 10 years from 2010 to 2019. The size of the company was used as a control variable. The study employs Return on Assets (ROA) and Earnings Per Share (EPS) to measure financial performance. Current ratio (CR) and total debts to total assets were used as proxies for liquidity and solvency management, while logarithm of total assets was used to measure the size. Correlation and multi regression analyses have been applied to analyze the data. The results show a statistically significant impact of independent and control variables (liquidity and solvency management and the size of the company) on financial performance, while the detailed results of the hypotheses indicate that liquidity has an insignificant reverse impact on financial performance. With respect to other variables, there is a significant positive impact of size on performance and a significant negative impact of solvency on performance. The study suggests in light of results, increasing investments in companies' assets by focusing on internal financing, such that large-sized companies with low leverage will have a good performance.

A Hybrid Automatic Focusing Method with Gaussian Interpolation and Adaptive Step Size (가우시안보간과 적응스텝크기를 적용한 하이브리드 오토포커싱)

  • Moon, Soon Hwan;Kim, Gyung Bum
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.1
    • /
    • pp.51-55
    • /
    • 2014
  • In this paper, an hybrid automatic focusing method has been proposed for speedy and reliable measurement and inspection in industry. It can improve reliability of focusing position by using not a focusing measure but the hybrid one that is incorporated with sobel operator and auto-correlation. Also, it can not only reduce control time of focusing position using adaptive step size, but also improve accuracy of focusing position by gaussian interpolation. Its performance is verified by experiments. It is expected that it can apply to optical system for measurement and inspection in industry fields.

Effect of Dry Deposition on Water Quality -The comparison of several methodologies for estimating dry deposition flux (수질에 대한 대기건식침적의 영향 - 건식침적량 추정 방법론의 비교를 중심으로)

  • Cheong, Jang-Pyo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.159-168
    • /
    • 2008
  • A special field experiment has been carried out from March 2001 to June 2001 at the Changhowon in Kyunggi to investigate a better methodology for the estimation of dry deposition of pollutions applicable in Korea. In this study, dry deposition plate was used to measure of total and water soluble acidic mass fluxes, and CPRI(Coarse Particle Rotary Impactor), CI(Cascade Impactor) were also used to measure ambient concentrations in various particle size ranges. Sehmel-Hodgson model was used to estimate dry depostion velocity and Weibull probability distribution function was applied to get generalized particle size distribution for the size fractioned concentration data sampled by CPRI and CI. Atmospheric dry deposition fluxes of mass and ionic matters estimated by the various techniques(one-step, multi-step, equi-concentration, subdivision for only the coarse particle range, applying Weibull distribution function, etc.) were compared to flux data sampled by DDP. It was found out that the deposition fluxes estimation methodology calculated by the each particle size range devided by particle size distribution characteristics and the rapidly changed points of deposition velocity using Weibull probability distribution function was the most applicable.

Development of wearable Range of Motion measurement device capable of dynamic measurement

  • Song, Seo Won;Lee, Minho;Kang, Min Soo
    • International journal of advanced smart convergence
    • /
    • v.8 no.4
    • /
    • pp.154-160
    • /
    • 2019
  • In this paper, we propose the miniaturization size of wearable Range of Motion(ROM) and a system that can be connected with smart devices in real-time to measure the joint movement range dynamically. Currently, the ROM of the joint is directly measured by a person using a goniometer. Conventional methods are different depending on the measurement method and location of the measurement person, which makes it difficult to measure consistently and may cause errors. Also, it is impossible to measure the ROM of joints in real-life situations. Therefore, the wearable sensor is attached to the joint to be measured to develop a miniaturize size ROM device that can measure the range of motion of the joint in real-time. The sensor measured the resistance value changed according to the movement of the joint using a load cell. Also, the sensed analog values were converted to digital values using an Analog to Digital Converter(ADC). The converted amount can be transmitted wireless to the smart device through the wearable sensor node. As a result, the developed device can be measured more consistently than the measurement using the goniometer, communication with IoT-based smart devices, and wearable enables dynamic observation. The developed wearable sensor node will be able to monitor the dynamic state of rehabilitation patients in real-time and improve the rapid change of treatment method and customized treatment.

A modified Zienkiewicz-Zhu error estimator

  • Stephen, D.B.;Steven, G.P.
    • Structural Engineering and Mechanics
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 1996
  • A new error measure for a static finite element analysis is proposed. This error measure is a modification to the Zienkiewicz and Zhu energy norm. The new error estimator is a global error measure for the analysis and is independent of finite element model size and internal stresses, hence it is readily transportable to other error calculations. It is shown in this paper the the new error estimator also produces conservative error measurements, making it a suitable procedure to adopt in commerical packages.

A Study on the Jacket Pattern for Elderly Women (노년여성을 위한 재킷패턴 연구)

  • Bae, Ju-Hyeong;Kim, In-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.7
    • /
    • pp.1008-1019
    • /
    • 2007
  • The purpose of this study was to develop an appropriate jacket pattern for elderly women over sixty years old, providing a good fit and appearance. Results were as follows: The length of the jacket was made long enough to cover the area 22.0cm below the waistline. The waist back length was made 1.7cm longer than the actual size of the waist back length. The armhole length was made 0.5cm longer than B/4, enhacing the appearance and functionality while allowing freer movement of the arms. As for the front and back interscye breadths, the front interscye breadth was made 1.7cm larger than the actual size while the back interscye breadth was only 1.0cm larger, providing the front interscye breadth more space. The bust breadth was made 10.0cm larger than the bust circumference measure(B/4+2.5cm), the waist breadth was made 6.0cm larger than the waist circumference measure(W/4+1.5cm), The hip breadth was made 12.0cm larger than the him circumference measure(H/4+3.0cm). The sleeve length was made 3.0cm larger than the arm length measure, as the sleeve length of a jacket is usually long enough to cover the ulnar styloid. The sleeve width was made 5.0cm larger than the upper arm circumference measure, as the upper arm circumference measure of the model pattern was too large than necessary, worsening the overall appearance. The sleeve cap height was set at AH/4+4.7cm. The wrist circumference of 27.0cm was set, allowing 2/3 and 1/3 for the large sleeve and small sleeve respectively.