• 제목/요약/키워드: maximum size

검색결과 4,180건 처리시간 0.038초

벨마우스 깊이가 다른 소형축류홴의 공력특성에 대한 실험적 연구 (Experimental Study on the Aerodynamic Performance Characteristics of a Small-Size Axial Fan with the Different Depths of Bellmouth)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.73-78
    • /
    • 2013
  • A Small-size axial fan(SSAF) has widely been utilized to circulate a cooling air in a refrigerator, etc. Generally, the aerodynamic performance of SSAF is strongly dependent upon the depth between SSAF and bellmouth, and it includes axial, partially stalled, mostly stalled and radial flow regions according to the flow coefficient. In this study, four kinds of bellmouth depths were considered to analyze the aerodynamic performance of SSAF. As a bellmouth depth increases, a maximum flowrate decreases, but a maximum static pressure increases. Also, stall region includes an inflection point in all aerodynamic performance curves. Finally, a static pressure efficiency shows the maximum value of 37%.

전통주택 사랑대청의 우물마루 구성요소에 관한 연구 (A Study on the Wumul-maru Components of Sarang-taechong in traditional Houses)

  • 오혜경;홍이경
    • 한국실내디자인학회논문집
    • /
    • 제20호
    • /
    • pp.10-16
    • /
    • 1999
  • The purpose of this study was the wumul-maru components of Sarang-taechong with themselves in traditional houses. Physical trace method was used for this study. The samples were taken from the Sarang-taechong of 6 traditional Korean houses, Yunkyungdang, the ancient Chusa estate, Sunkyojang, Chunghyodang, Yangjindang, Unjoru. The major findings were summarized as follows; 1) Regarding to the changgui't'ul(long board); the number was from 0(minimum) to 3(maximum), the size was $244.3{\times}4407.1mm$ on average, and the proportion was 1:18.9. 2) Regarding to the tongguit'ul(center board); the number was from 5(minimum) to 18(maximum), the size $188.7{\times}2374mm$ on average, and the proportion was 1:12.9. 3) Regarding to the marunol; the number was from 42(minimum) to 155(maximum), the size was $247{\times}574mm$ on average and the proportion was 1:2.29.

  • PDF

CONDENSATION IN DENSITY DEPENDENT ZERO RANGE PROCESSES

  • Jeon, Intae
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제17권4호
    • /
    • pp.267-278
    • /
    • 2013
  • We consider zero range processes with density dependent jump rates g given by $g=g(n,k)=g_1(n)g_2(k/n)$ with $g_1(x)=x^{-\alpha}$ and $$g_2(x)=\{^{x^{-\alpha}\;if\;a&lt;x}_{Mx^{-\alpha}\;if\;x{\leq}a}$$. (0.1) In this case, with 1/2 < a < 1 and ${\alpha}$ > 0, we show that non-complete condensation occurs with maximum cluster size an. More precisely, for any ${\epsilon}$ > 0, there exists $M^*$ > 0 such that, for any 0 < M ${\leq}M^*$, the maximum cluster size is between (a - ${\epsilon}$)n and (a + ${\epsilon}$)n for large n. This provides a simple example of non-complete condensation under perturbation of rates which are deep in the range of perfect condensation (e.g. ${\alpha}$ >> 1) and supports the instability of the condensation transition.

화원의 높이 및 화재크기별 터널 천장온도 측정 실험 (Measurement of Ceiling Temperature in Tunnel for Heights and Fire Sizes of Fire Source)

  • 박원희
    • 한국유체기계학회 논문집
    • /
    • 제18권1호
    • /
    • pp.5-10
    • /
    • 2015
  • The "Ondong tunnel" is not used now where is one of the tunnels in the Janghang line which is from Cheonan to Iksan. The length of the tunnel is 214 m. The location of the fire source is center of the tunnel and the pool fire with heptane is for the fire source. Tests are carried out for the various fire sizes, the height and obstructed/open condition of the fire source. Temperature on the top of the tunnel is measured. Even if the fire size is same, the maximum temperature on the ceiling of the tunnel for the elevated fire source is very larger than the maximum for the ground fire source. As the fire size is lager the maximum temperature on the ceiling is higher. These test results can be very useful for design and guidelines of fire detectors in tunnels.

Spectrophotometric Determination of Maximum Loading Capacity of a Dendrimer

  • Youngjin Jeon
    • 대한화학회지
    • /
    • 제67권4호
    • /
    • pp.217-221
    • /
    • 2023
  • A series of hydrophobic dodecyl-terminated 6th-generation poly(amidoamine) dendrimer (H)-encapsulated cadmium sulfide ((CdS)n@H) nanoparticles in a co-solvent (toluene: methanol = 6.8: 3.2 v/v) are synthesized. The diameters of CdS nanoparticles within the dendrimer were estimated by analyzing the positions of the first excitonic absorption peaks of CdS in UV-vis spectra. The size of the CdS nanoparticle within the dendrimer shows a saturation value as the CdS/H ratio (n) increases, which is believed to be due to the limited physical size of the void cavity within the dendrimer. This simple and convenient method of estimating the saturation of the size of CdS in dendrimers may be useful in determining the maximum void space within other dendrimers under various solvent conditions.

Effect of fiber and aggregate size on mode-I fracture parameters of high strength concrete

  • Kumar, Ch.Naga Satish;Krishna, P.V.V.S.S.R.;Kumar, D.Rohini
    • Advances in concrete construction
    • /
    • 제5권6호
    • /
    • pp.613-624
    • /
    • 2017
  • In this paper, an experimental investigation was carried out to study the effect of volume fraction of fiber and maximum aggregate size on mode-I fracture parameters of high strength concrete. Total of 108 beams were tested on loading frame with three point loading, the variables in the high strength concrete beams are aggregate size (20 mm, 16 mm and 10 mm) and volume fraction of fibers (0%, 0.5%, 1% and 1.5%). The fracture parameters like fracture energy, brittleness number and fracture process zone were analyzed by the size effect method (SEM). It was found that fracture energy (Gf) increases with increasing the Maximum aggregate size and also increasing the volume of fibers, brittleness number (${\beta}$) decreases and fracture process zone (CF) increases.

마이크로컨트롤러 환경에서 타깃 바이너리 파일 분석을 통한 최대 스택 메모리 사용량 예측 기법 (Maximum Stack Memory Usage Estimation Through Target Binary File Analysis in Microcontroller Environment)

  • 최기호;김성섭;박대진;조정훈
    • 대한임베디드공학회논문지
    • /
    • 제12권3호
    • /
    • pp.159-167
    • /
    • 2017
  • Software safety is a key issue in embedded system of automotive and aviation industries. Various software testing approaches have been proposed to achieve software safety like ISO26262 Part 6 in automotive environment. In spite of one of the classic and basic approaches, stack memory is hard to estimating exactly because of uncertainty of target code generated by compiler and complex nested interrupt. In this paper, we propose an approach of analyzing the maximum stack usage statically from target binary code rather than the source code that also allows nested interrupts for determining the exact stack memory size. In our approach, determining maximum stack usage is divided into three steps: data extraction from ELF file, construction of call graph, and consideration of nested interrupt configurations for determining required stack size from the ISR (Interrupt Service Routine). Experimental results of the estimation of the maximum stack usage shows proposed approach is helpful for optimizing stack memory size and checking the stability of the program in the embedded system that especially supports nested interrupts.

입도분포계수를 이용한 사질토의 최대건조단위중량 예측 (Prediction of Maximum Dry Unit Weight of Sandy Soils From Grain-Size Distribution Parameters)

  • 송영우;진명섭;홍기남
    • 한국도로학회논문집
    • /
    • 제6권3호
    • /
    • pp.55-64
    • /
    • 2004
  • 최대건조단위중량은 노상토 재료 특성으로서 매우 중요한 인자이다. 최대건조단위중량을 예측하는 기존의 모델들은 많은 변수를 포함하고 있어 다소 복잡해 보인다 본 논문에서는 사질토의 최대건조단위중량을 예측할 수 있는 간편한 식을 제안하였다. 이를 위해 36개 시료를 체분석하여 입도분포를 구하고, 다짐시험 한 후 그 결과를 회귀 분석하였다. 제안식은 변수로 노상토의 기하평균과 기하표준편차 또는 입도분포계수를 포함한다. 제안식의 검증을 위해 전국16개 지역의 채취 시료에 대한 최대건조단위중량의 실측치와 예측치를 비교한 결과 잘 맞는 것으로 밝혀졌다.

  • PDF

지오그리드의 시공중 손상 평가를 위한 실험적 연구 (Experimental Study for Installation Damage Assessment of Geogrid)

  • 조삼덕;이광우;오세용
    • 한국환경복원기술학회지
    • /
    • 제8권1호
    • /
    • pp.27-36
    • /
    • 2005
  • Geosynthetic reinforcements may be damaged during its installation in the filed. The installation damage mainly depends on two factors such as materials used and construction activities. This paper describes the results of a series of field tests, which are conducted to assess the installation damage of geogrid according to different maximum grain sizes of fills (40, 60, and 80 mm). These tests are done in three sites for twelve different kinds of geogrids. After field tests, the changes in tensile strength of the geogrids is determined from wide width tensile tests using both damaged and undamaged specimens. In the results of tests, tensile strength of the relatively flexible geogrids after field installation tests was decreased about from 20% to 40% according to the increment of the maximum grain size. On the other hand, for the relatively stiff geogrids, the loss of the tensile strength after site installation was examined below 5.2% independent of the maximum grain size of the soils. The results of this study show that the installation damage significantly depends on the stiffness of geogrid and is more obvious to a flexible geogrid and a fill material having higher maximum grain size.

HBPI 제어기를 이용한 태양광발전 시스템의 MPPT 제어 (MPPT Control of Photovoltaic System using HBPI Controller)

  • 고재섭;정동화
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1864-1871
    • /
    • 2012
  • This paper proposes the hybrid proportional integral(HBPI) controller for maximum power point tracking(MPPT) control of photovoltaic system. The output characteristics of the solar cell are a nonlinear and affected by a temperature, the solar radiation and influence of a shadow. The MPPT control is a very important technique in order to increase an output and efficiency of the photovoltaic system. The conventional constant voltage(CV), perturbation and observation(PO) and incremental conductance(IC) are the method which finding maximum power point(MPP) by the continued self-excitation vibration, and uses the fixed step size. If the fixed step size is a large, the tracking speed of maximum power point is faster, but the tracking accuracy in the steady state is decreased. On the contrary, when the fixed step size is a small, the tracking accuracy is increased and the tracking speed is slower. Therefore, in order to solve these problems, this paper proposes HBPI controller that is adjusted gain of conventional PI control using fuzzy control, and the maximum power point tracks using this controller. The validity of the controller proposed in this paper proves through the results of the comparisons.