• 제목/요약/키워드: maximum loading

검색결과 1,533건 처리시간 0.024초

양방향말뚝재하시험의 재하용량 기준에 관한 연구 (A Study on the Loading Capacity Standard of Bi-directional Pile Load Test (BD PLT))

  • 최용규
    • 대한토목학회논문집
    • /
    • 제28권6C호
    • /
    • pp.379-388
    • /
    • 2008
  • 대형말뚝기초의 양방향 재하시험에서 재하용량 기준이 정확하게 규정되어 있지 않다. 그래서 양방향말뚝재하시험을 수행함에 있어 많은 혼란이 발생하고 있으며 재하용량에서 최대 2배까지의 차이가 나타나고 있다. 본 연구에서는 양방향 말뚝재하시험 기준들을 고찰하였으며, 국내에서 수행된 양방향 말뚝재하시험 사례들에 기초하여 최대등가시험하중, 재하하중 증가비, 재하용량 증가비 및 설계하중 충족비를 분석하였다. 양방향 말뚝재하시험 기준은 1방향 재하용량으로 정의되어야 하며, 1방향 재하용량은 설계하중의 2배 이상 이어야 한다는 것을 알 수 있었다.

변동하중에서 미소하중의 제거가 균열진전에 미치는 영향 (The Effect on Fatigue Crack Growth due to Omitting Low-amplitude Loads from Variable Amplitude Loading)

  • 심동석;이승호;김정규
    • 동력기계공학회지
    • /
    • 제8권4호
    • /
    • pp.11-16
    • /
    • 2004
  • In this study, to investigate the effects of omitting low-amplitude cycles from a flight-simulation loading, crack growth tests were conducted on 2124-T851 aluminum alloy specimens. Three test spectra were generated by omitting small load ranges as counted by the rain-flow count method. The crack growth test results were compared with the data obtained from the flight-simulation loading. The experimental results show that the ranges equal to or smaller than 5% of the maximum load do not contribute to crack growth behavior because these are below the initial stress intensity factor range. Omitting these from the flight-simulation loading, test time can be reduced by 54%. However, in the case of omitting the load ranges below 15% of the maximum load, crack growth rates decreased, and crack growth curve deviated from the crack growth data under the flight-simulation loading because loading cycles above fatigue fracture toughness were omitted.

  • PDF

Response of a laterally loaded pile group due to cyclic loading in clay

  • Shi, Jiangwei;Zhang, Yuting;Chen, Long;Fu, Zhongzhi
    • Geomechanics and Engineering
    • /
    • 제16권5호
    • /
    • pp.463-469
    • /
    • 2018
  • In offshore engineering, lateral cyclic loading may induce excessive lateral movement and bending strain in pile foundations. Previous studies mainly focused on deformation mechanisms of single piles due to lateral cyclic loading. In this paper, centrifuge model tests were conducted to investigate the response of a $2{\times}2$ pile group due to lateral cyclic loading in clay. After applying each loading-unloading cycle, the pile group cannot move back to its original location. It implies that residual movement and bending strain are induced in the pile group. This is because cyclic loading induces plastic deformation in the soil surrounding the piles. As the cyclic load increases from 62.5 to 375 kN, the ratio of the residual to the maximum pile head movements varies from 0.30 to 0.84. Moreover, the ratio of the residual to the maximum bending strains induced in the piles is in a range of 0.23 to 0.82. The bending strain induced in the front pile is up to 3.2 times as large as that in the rear pile. Thus, much more protection measures should be applied to the front piles to ensure the serviceability and safety of pile foundations.

반복하중 재하 시 모래-타이어칩 혼합토의 최대전단탄성계수 변화 (Maximum Shear Modulus of Sand - Tire Chip Mixtures under Repetitive KO Loading Conditions)

  • 류병욱;박정희;추현욱
    • 한국지반환경공학회 논문집
    • /
    • 제22권12호
    • /
    • pp.41-50
    • /
    • 2021
  • 본 연구의 목적은 모래와 타이어칩 혼합토의 반복하중조건 전후 공학적 특성 변화를 파악하는 것이다. 반복하중 시, 시료에 함유된 타이어칩 함량 및 모래와 타이어칩 입자 간의 크기비에 따른 최대전단탄성계수의 변화를 정량화 하고자, 전체 중량 대비 타이어칩 중량을 0, 10, 20, 40, 60, 100%로 하여 시료를 조성하였으며, 타이어칩 평균입경 대비 모래의 평균입경(입자크기비)을 0.44, 1.27, 1.87, 4.00으로 설정하여 혼합토를 조성하였다. 초기 상대밀도 50%의 시료를 floating wall 형태의 몰드에 조성 후, 공기압 축기(air compressor), 압력 패널(pressure panel) 및 뉴메틱 밸브(pneumatic valve)를 이용하여 정하중 재하(=50kPa), 반복하중 재하(=50-150kPa), 정하중 재하(=400kPa) 및 제하 순으로 실험이 이루어 졌다. 위의 실험이 진행됨에 따라 시료의 침하량과 전단파속도를 측정하였다. 시험 결과, 모래-타이어칩 혼합토에 가해지는 반복하중은 시료를 이루는 입자 간 접촉을 타이어칩-타이어칩 또는 타이어칩-모래에서 모래-타이어칩 또는 모래-모래로 전환시켰으며, 이로 인해 타이어칩 함량 40%에서 가장 큰 최대전단탄성계수의 증가를 확인하였다. 또한 입자크기비가 감소함에 따라 동일 타이어칩 함량에서 반복하중 시 최대전단탄성계수 증가량은 증가하였다.

앉았다 일어서기 동작 수행 시 발목 관절 각도에 따른 근 활성도 및 역학적 부하량의 비교 (A Comparison of Muscle Activation and Mechanical Loading according to the Degree of Ankle Joint Motion during a Sit-to-stand Task)

  • 이명모;박대성
    • 대한물리의학회지
    • /
    • 제12권4호
    • /
    • pp.113-122
    • /
    • 2017
  • PURPOSE: The purpose of this study was to investigate the comparison of muscle activity and mechanical loading according to the angle of ankle joint during a sit-to-stand (STS) task. METHODS: Thirty-four young participants performed the STS in a randomized trial with the ankle joint at a neutral, 15 degrees dorsiflexion and 15 degrees plantarflexion angle in a fixed sitting posture with the knee in 105 degrees flexion. Muscle activity of the tibialis anterior (TA), rectus femoris (RF), biceps femoris (BF), and gastrocnemius medialis (GCM) was measured, and the parameters calculated in relation to mechanical loading were the STS-time, maximum peak, minimum peak, and total sum of mechanical loading. RESULTS: In the dorsiflexion position, the muscle activity of the TA and GCM showed a significant increase (p<.05), and the STS time, maximum peak and total sum of mechanical loading showed a significant difference compared to that in the neutral position (p<.05). In the plantarflexion position, the muscle activity of the RF and GCM showed a significant increase (p<.05), while that of the TA showed a significant decrease (p<.05) compared to that in the neutral position. And the minimum peak was significantly increased than the neutral position (p<.05), and the maximum peak and total sum of mechanical loading were showed significant difference compared with dorsiflexion position (p<.05). CONCLUSION: These results show that there is a difference in muscle activity and mechanical loading when performing the STS movement according to the change in the ankle joint angle.

Material Characteristics of Dental Implant System with In-Vitro Mastication Loading

  • 정태곤;정용훈;이수원;양재웅;정재영;박광민;강관수
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.72-72
    • /
    • 2018
  • A dynamic fatigue characteristic of dental implant system has been evaluated with applying single axial compressive shear loading based on the ISO 14801 standard. For the advanced dynamic fatigue test, multi-directional force and motion needed to be accompanied for more information of mechanical properties as based on mastication in oral environment. In this study, we have prepared loading and motion protocol for the multi-directional fatigue test of dental implant system with single (Apical/Occlusal; AO), and additional mastication motion (Lingual/Facial; LF, Mesial/Distal; MD). As following the prepared protocol (with modification of ISO 14801), fatigue test was conducted to verify the worst case results for the development of highly stabilized dental implant system. Mechanical testing was performed using an universal testing machine (MTS Bionix 858, MN, USA) for static compression and single directional loading fatigue, while the multi-directional loading was performed with joint simulator (ADL-Force 5, MA, USA) under load control. Basically, all mechanical test was performed according to the ISO 14801:2016 standard. Static compression test was performed to identify the maximum fracture force with loading speed of 1.0 mm/min. A dynamic fatigue test was performed with 40 % value of maximum fracture force and 5 Hz loading frequency. A single directional fatigue test was performed with only apical/occlusal (AO) force application, while multi directional fatigue tests were applied $2^{\circ}$ of facial/lingual (FL) or mesial/distal (MD) movement. Fatigue failure cycles were entirely different between applying single-directional loading and multi-directional loading. As a comparison of these loading factor, the failure cycle was around 5 times lower than single-directional loading while applied multi-directional loading. Also, the displacement change with accumulated multi-directional fatigue cycles was higher than that of single directional cycles.

  • PDF

Glass FRP-Bonded RC Beams under Cyclic Loading

  • Tan, Kiang-Hwee;Saha, Mithun-Kumar
    • International Journal of Concrete Structures and Materials
    • /
    • 제1권1호
    • /
    • pp.45-55
    • /
    • 2007
  • Ten beams bonded with glass fiber reinforced polymer (GFRP) laminates were tested under cyclic loading with the load range and the FRP reinforcement ratio as test parameters. The maximum load level during cyclic loading was 55%, 65% and 75% of the static flexural strength while the minimum load level was kept constant at 35%. Deflections of the beams at the end of 525000 cycles were found to increase by 16% and 44% when the maximum load level was increased from 55% to 65% and 75% of the static flexural strength, respectively. Beams with FRP reinforcement ratios of 0.64% and 1.28% were found to exhibit lesser deflections of about 15% and 20%, respectively, compared to a similar beam without FRP reinforcement. An analytical approach based on cycle-dependent effective moduli of elasticity of concrete and FRP reinforcement is presented and found to predict the deflections of the test beams well.

Biomechanical investigation of maxillary implant-supported full-arch prostheses produced with different framework materials: a finite elements study

  • Mirac Berke Topcu, Ersoz;Emre, Mumcu
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권6호
    • /
    • pp.346-359
    • /
    • 2022
  • PURPOSE. Four and six implant-supported fixed full-arch prostheses with various framework materials were assessed under different loading conditions. MATERIALS AND METHODS. In the edentulous maxilla, the implants were positioned in a configuration of four to six implant modalities. CoCr, Ti, ZrO2, and PEEK materials were used to produce the prosthetic structure. Using finite element stress analysis, the first molar was subjected to a 200 N axial and 45° oblique force. Stresses were measured on the bone, implants, abutment screw, abutment, and prosthetic screw. The Von Mises, maximum, and minimum principal stress values were calculated and compared. RESULTS. The maximum and minimum principal stresses in bone were determined as CoCr < ZrO2 < Ti < PEEK. The Von Mises stresses on the implant, implant screw, abutment, and prosthetic screws were determined as CoCr < ZrO2 < Ti < PEEK. The highest Von Mises stress was 9584.4 Mpa in PEEK material on the prosthetic screw under 4 implant-oblique loading. The highest maximum principal stress value in bone was found to be 120.89 Mpa, for PEEK in 4 implant-oblique loading. CONCLUSION. For four and six implant-supported structures, and depending on the loading condition, the system accumulated different stresses. The distribution of stress was reduced in materials with a high elastic modulus. When choosing materials for implant-supported fixed prostheses, it is essential to consider both the number of implants and the mechanical and physical attributes of the framework material.

가력유형별 군중하중의 크기에 관한 실험적 연구 (The Size of Crowd Pressure According to Loading Patterns)

  • 김진식;신윤호;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.128-129
    • /
    • 2016
  • This study is to categorize the loading of multiple persons on a vertical building elements into three types to test the size of crowd pressure under each loading patterns. The loading patterns is divided under the combination of loading method and loading persons. The loading method is categorized into the method of instantaneous loading of hand on a force plate and the method of continuous loading. The loading persons has been composed of 1~5 persons under the loading patterns. The loading patterns is also divided into lateral loading, longitudinal loading, and agglomeration loading. The subject group has been composed of 12 males in 20s. The load measurement device(size 1800×600×36mm, capacity 20kN, rigidity 28kN/cm) has been designed and manufactured directly. To eliminate the difference of individual, the size of crowd pressure has been converted into the strength to weight ratio (maximum load/weight) for computation. The strength to weight ratio in lateral loading was about 0.91 under instantaneous loading and about 0.47 under continuous loading. The strength to weight ratio in longitudinal loading was about 0.65 under instantaneous loading and about 0.36 under continuous loading. The strength to weight ratio in agglomeration loading was about 0.65 under instantaneous loading and about 0.36 under continuous loading.

  • PDF

교량 내하력 평가를 위한 정적재하시험 및 동적재하시험 특성 (Characteristics of Static Loading and Dynamic Loading Tests for Bridge Capability)

  • 이상훈
    • 한국재난정보학회 논문집
    • /
    • 제16권4호
    • /
    • pp.638-649
    • /
    • 2020
  • 연구목적: 본 연구에서는 공용년수 20년이 경과된 콘크리트 단순 슬래브교를 대상으로 하여 대상교량 구조물의 내하성능을 평가하는 것을 목적으로 하였다. 연구방법: 정적재하시험 및 동적재해시험을 수행함으로써 변위, 변형율, 충격계수, 고유진동수 값을 실측하였으며, 해석방법을 통해 평가하였다. 연구결과: 본 연구를 통해 나타난 주요 결과는 다음과 같다. 첫째, S1 최대 변위 및 최대 변형률은 각각 2.917 mm, 44.720 𝜇ε(인장), -13.760 𝜇ε(압축)로 평가되었으며, S2 최대 변위 및 최대 변형률은 각각 2.100 mm, 4.870 𝜇ε(인장)로 나타났다. 둘째, 최대 실측충격계수는 S1 A-A단면에서 0.242로 나타났으며, 최대 실측충격계수는 S2 C-C단면에서 0.198로 나타났다. 셋째, 고유진동수를 해석결과, 6.086Hz로 평가되었고, 측정결과 6.152Hz-6.738Hz의 범위로 나타났다. 결론: 시험대상 교량은 설계하중에 대하여 양호한 거동 및 특성을 보이는 것으로 평가할 수 있다.