• Title/Summary/Keyword: maximum load

Search Result 3,948, Processing Time 0.031 seconds

Position Control of a Pneumatic Cylinder Actuator using PLC and Proximity Sensors (공압 실린더 액츄에이터 위치제어)

  • Kwon, Soon-Hong;Choi, Won-Sik;Chung, Sung-Won;Park, Jong-Min;Kwon, Soon-Goo;So, Jung-Duk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.50-55
    • /
    • 2011
  • The fluid power products are widely used in current industrial area such as automation of products and equipment assembly, high-tech machine tool, aircraft, train, and etc. As the development of industry is in progress, the development of the fluid power products is demanding and it is required in every industrial area. This research proposed a pneumatic system to evaluate displacement accuracy of the pneumatic actuator without external load and to analyze capability of integration of the valve system. The pneumatic system consisted of a combination of pneumatic actuator, four two-port valves, two three-port valves, two pressure valve, a check valve, two proximity sensors, and a program logic controller (PLC). The position controller is based on the PLC connected with the proximity sensors. The maximum air pressure applied for tests was $49.05N/cm^2$ and the displacement accuracy of a stroke was measured using a dial gauge. The supply- and discharge-side of air pressure and the length of the stroke of the pneumatic cylinder were varied The test of the position control of the pneumatic cylinder was carried out 50 times at each supply- and discharge-side air pressure of 24.53/34.34, 29.43/39.24, 34.34/44.15, and $39.24/49.05N/cm^2$ and replicated three times. The accuracy of the displacement of the pneumatic cylinder stroke increased as the supply- and discharge-side of air pressure increased with the stroke length of 133mm. Also the displacement accuracy increased as the stroke length increased with the fixed supply- and discharge-side of air pressure of the pneumatic cylinder as 34.34 and $44.15N/cm^2$, respectively. The most accurate displacement of the pneumatic cylinder was obtained at the supplyand discharge-side of air pressure of 39.24 and $49.05N/cm^2$, respectively, and strokes of 170 and 190mm.

Changes of Characteristics in Kochujang Fermented with Maesil (Prunus mume) Powder or Concentrate (매실분말 및 농축액을 첨가한 고추장의 숙성중 품질 변화)

  • Park, Woo-Po;Cho, Sung-Hwan;Lee, Seung-Chul;Kim, Sung-Yong
    • Food Science and Preservation
    • /
    • v.14 no.4
    • /
    • pp.378-384
    • /
    • 2007
  • Powder, or a concentrate, of maesil (Prunus mume) were used in the making of kochujang, and were added to kochujang at 0.5 or 1.0% (w/w). Kochujang fermented with maesil powder lower moisture content than did samples fermented with maesil concentrate. Moisture content slowly increased during fermentation, and was $3{\sim}4%$ higher than the initial value after 8 weeks of fermentation. Kochujang fermented with maesil powder or maesil concentrate showed lower pH values and higher total acidities than did the control. The total microbial count was $3.6{\times}10^7\;5.4{\times}10^7\;cfu/g$, and yeast and mold levels were $2.0{\times}10^7{\sim}3.6{\times}10^7\;cfu/g$, as kochujang fermentation commenced. Microbial load reached a maximum by 4 weeks of fermentation, and decreased thereafter. L (lightness), a (redness) and b (yellowness) values of kochujang gradually decreased during fermentation. Compared to methanol extracts of kochujang, water extracts and ethanol extracts showed higher free radical scavenging abilities at the initial stage of fermentation. Control, and samples with 0.5% (w/w) maesil powder or maesil concentrate, attained higher scores in sensory evaluation tests than did samples with higher maesil levels, and were not significantly different at P>0.05 as determined by Duncan's multiple range test.

Physical and Mechanical Properties of Synthetic Lightweight Aggregate Concrete (인공경량골재(人工輕量骨材) 콘크리트 물리(物理)·역학적(力學的) 특성(特性))

  • Kim, Seong Wan;Min, Jeong Ki;Sung, Chan Yong
    • Korean Journal of Agricultural Science
    • /
    • v.24 no.2
    • /
    • pp.182-193
    • /
    • 1997
  • The normal cement concrete is widely used material to build the construction recently, but it has a fault to increase the dead load on account of its unit weight is large compared with strength. Therefore, many engineers are continuously searching for new materials of construction to provide greater performance at lower density. The main purpose of the work described in this paper were to establish the physical and mechanical properties of synthetic lightweight aggregate concrete using perlite on fine aggregate and expanded clay, pumice stone on coarse aggregate. The test results of this study are summarized that the water-cement ratio was shown 47% using expanded clay, 56% using pumice stone on coarse aggregate, unit weight was shown $l,622kgf/m^3$ using expanded clay, $l,596kgf/m^3$ using pumice stone on coarse aggregate, and the absorption ratio was shown same as 17%. The compressive strength was shown more than $228kgf/cm^2$, tensile and bending strength was more than $27kgf/cm^2$, $58kgf/cm^2$ at all types, and rebound number with schmidt hammer was increased with increase of compressive strength. The static modulus was $1.12{\times}10^5kgf/cm^2$ using expanded clay, $1.09{\times}10^5kgf/cm^2$ using pumice stone on coarse aggregate, and stress-strain curves were shown that increased with increase of stress, and the strain on the maximum stress was shown identical with $2.0{\times}10^{-3}$, approximately.

  • PDF

Cyclic Structural Characteristics of Thermal Bridge Breaker Systems embedded in Reinforced Concrete Slabs (벽-슬래브 접합부에 매립된 열교차단장치의 반복하중에 대한 거동특성 평가)

  • Shin, Dong-Hyeon;Oh, Moung-Ho;Kim, Young-Ho;Kim, Hyung-Joon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.5
    • /
    • pp.511-521
    • /
    • 2015
  • The thermal bridge occurring in a building influences its thermal performance and durability. The domestic typical multi-unit residential buildings suffer thermal losses resulting from thermal bridges of the balcony slab. To minimize the thermal loss between inside and outside of the balcony slab, thermal bridge breaker(TBB) systems have been developed and applied in building construction. Although thermal bridge breaker systems for reinforced concrete(RC) wall-slab joints can improve the thermal performance of a building, it is necessary to verify the structural performance of TBB systems whether they provide proper resistance for cyclic loading. In order to investigate the structural characteristics of TBB systems embedded in RC slabs, cyclic tests of wall-slab joints were performed by applying two reversed cycles at each up to 30 cycles. The test results show that the RC slabs embedding TBBS systems can present excellent structural performance and the maximum moment capacity, energy dissipation capacity and ductility of TBBs systems are enhanced compared to those of the typical RC slabs.

Analysis of Rainfall Effect on the GIUH Characteristic Velocity (GIUH 특성속도에 대한 강우의 영향 분석)

  • Kim, Kee-Wook;Roh, Jung-Hwan;Jeon, Yong-Woon;Yoo, Chul-Sang
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.4
    • /
    • pp.533-545
    • /
    • 2003
  • This study analyzed several storm events observed in the Seolma-chun basin to derive the characteristic velocity of GIUH (Geomophological Instantaneous Unit Hydrograph) as well as its variability. Especially, this study focused on the variation of characteristic velocity due to the change of rainfall characteristics. The IUH of the Seolma-chun basin was derived using the HEC-1, whose peak discharge and time were then compared with those of the GIUH to derive the characteristic velocities. The characteristics velocities were analyzed by comparing with the GcIUH (Geomorphoclimatic IUH) as well as the characteristics of rainfall. Results are summarized as follows. (1) The characteristic velocity of GIUH was estimated higher with higher variability than the GcIUH, but their trends were found similar (2) Total amount of effective rainfall (or, mean effective rainfall) well explains the characteristic velocity of GIUH. This could be assured by the regression analysis, whose coefficient of determination was estimated about 0.6. (3) The duration and the maximum intensity of rainfall were found not to affect significantly on the characteristic velocity of GIUH. The coefficients of determination were estimated less than 0.3 for all cases considered. (4) For the rainfall events used in this study, the characteristic velocities of GIUH were found to follow the Gaussian distribution with its mean and the standard deviation 0.402 m/s and 0.173 m/s, respectively. Most of the values are within the range of 0.4∼0.5 m/s, and its coefficient of variation was estimated to be 0.43, much less than that of the runoff itself (about 1.0).

Determination of EMCs for Rainfall Ranges from Transportation Landuses (교통관련 토지이용에서의 강우계급별 EMC 산정)

  • Lee, So-Young;Maniquiz, Marla C.;Choi, Ji-Yeon;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.11 no.2
    • /
    • pp.67-76
    • /
    • 2009
  • The contribution of pollutant loadings from non-point source (NPS) to the four major rivers in Korea exceeded 22~37 % of the total loadings in 2004 and is expected to reach 60 % in 2020. Most of NPS loadings are coming from urban areas, especially from paved areas. Because of high imperviousness rate, many types of NPS pollutant are accumulating on the surface during dry periods. The accumulated pollutants are wash-off during a storm and highly degrading the water quality of receiving water bodies. For this reason, the Korean Ministry of Environment (MOE) developed the Total Maximum Daily Load (TMDL) program to protect the water quality by managing the point source and NPS loadings. NPS has high uncertainties during a storm because of the characteristics of rainfall and watershed areas. The rainfall characteristics can affect on event mean concentrations (EMCs), mass loadings, flow rate, etc. Therefore, this research was performed to determine EMCs for rainfall ranges from transportation landuses such as road and parking lot. Two sites were monitored over 45 storm events during the 2006/06 through 2008/10 storm seasons. Mean TSS EMCs decrease as rainfall ranges increase and highest at less than 10mm rainfall. The results of this study can be used to determine the efficient scale of BMP facility considering specific rainfall range.

  • PDF

Step-down Piezoelectric Transformer Using PZT PMNS Ceramics

  • Lim Kee-Joe;Park Seong-Hee;Kwon Oh-Deok;Kang Seong-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.102-110
    • /
    • 2005
  • Piezoelectric transformers(PT) are expected to be small, thin and highly efficient, and which are attractive as a transformer with high power density for step down voltage. For these reasons, we have attempted to develop a step-down PT for the miniaturized adaptor. We propose a PT, operating in thickness extensional vibration mode for step-down voltage. This PT consists of a multi-layered construction in the thickness direction. In order to develop the step-down PT of 10 W class and turn ratio of 0.1 with high efficiency and miniaturization, the piezoelectric ceramics and PT designs are estimated with a variety of characteristics. The basic composition of piezoelectric ceramics consists of ternary yPb(Zr$_{x}$Ti$_{1-x}$)O$_{3}$-(1-y)Pb(Mn$_{1/3}$Nb1$_{1/3}$Sb$_{1/3}$)O$_{3}$. In the piezoelectric characteristics evaluations, at y=0.95 and x=0.505, the electromechanical coupling factor(K$_{p}$) is 58$\%$, piezoelectric strain constant(d$_{33}$) is 270 pC/N, mechanical quality factor(Qr$_{m}$) is 1520, permittivity($\varepsilon$/ 0) is 1500, and Curie temperature is 350 $^{\circ}C$. At y = 0.90 and x = 0.500, kp is 56$\%$, d33 is 250 pC/N, Q$_{m}$ is 1820, $\varepsilon$$_{33}$$^{T}$/$\varepsilon$$_{0}$ is 1120, and Curie temperature is 290 $^{\circ}C$. It shows the excellent properties at morphotropic phase boundary regions. PZT-PMNS ceramic may be available for high power piezoelectric devices such as PTs. The design of step-down PTs for adaptor proposes a multi-layer structure to overcome some structural defects of conventional PTs. In order to design PTs and analyze their performances, the finite element analysis and equivalent circuit analysis method are applied. The maximum peak of gain G as a first mode for thickness extensional vibration occurs near 0.85 MHz at load resistance of 10 .The peak of second mode at 1.7 MHz is 0.12 and the efficiency is 92$\%$.

The Concentrations of Endocrine Disrupter (PCBs and DDE) in the Serumand Their Predictors of Exposure in Korean Women (일부 한국 성인 여성들의 혈중 내분비계 장애물질 농도 및 그 노출요인의 연구)

  • 민선영;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.127-137
    • /
    • 2001
  • Polychlorinated biphenyls(PCBs) are halogenated aromatic compounds with the empirical formula $C_{12}$ $H_{10-n}$C $l_{n}$(n=1~10), and are a mixture of possible 209 different chlorinated congeners. PCBs were widely used as dielectric fluids for capacitors and transformers, plasticizers, lubricant inks and paint addirives. Once released into the environment, PCBs persist for years because they are so resistant to degradation. In addition to their persistence in the environment, PCBs in ecological food chains undergo biomagnification because of their high degree of lipophilicity. In 1970s, the worldwide production of PCBs was ceased and the import of PCBs was prohibited since 1983 in Korea. In spite of these actions, many PCBs seems to be still in use. The environmental load of PCBs will continue to be recycled through air, land, water, and the biosphere for decades to come. This study was conducted to measure the concentrations of PCBs in the serum samples of 112 women by GC/MSD and GC/ECD. The main results of this study were as follows. 1. PCBs were detected in all samples. The mean $\pm$SD levels of PCBs in the serum were 3.613$\pm$0.759 ppb, and median were 3.828 ppb. 2. The correlation coefficients of the concentrations of 13 PCB congeners were from minimum, 0.7913 to maximum, 0.9985, and all was significant(p=0.0001). The correlation coefficient between the concentrations of PCBs and p,p'-DDE was 0.9641(p=0.0001). 3. There was a positive association between age and PCBs' concentrations (simple linear regression ; $R^2$=0.86, $\beta$=0.08023, p<0.001). 4. There was a positive association between total lipids in the serum and PCBs' concentrations (simple linear regression ; $R^2$=0.7058, $\beta$=0.00486, p<0.001). 5. For possible predictors of PCBs and p,p' -DDE levels in the serum, age adjusted model (Y=$\beta$$_{0}$+$\beta$$_1$age+ $B_2$X) was applied. For BMI, major residential area, wether to eat caught fish by angling, where to eat caught fish by angling(by parents in the past), fish consumption, meat consumption, meat consumption, and dairy consumption, there was no association. For total conception frequency and lactation frequency and lactation period, there was negative association.ion.

  • PDF

Feasibility of Optoelectronic Neural Stimulation Shown in Sciatic Nerve of Rats (흰쥐의 좌골 신경 자극을 통한 광전 자극의 가능성에 대한 연구)

  • Kim Eui tae;Oh Seung jae;Baac Hyoung won;Kim Sung june
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.611-615
    • /
    • 2004
  • A neural prostheses can be designed to permit stimulation of specific sites in the nervous system to restore their functions, lost due to disease or trauma. This study focuses on the feasibility of optoelecronic stimulation into nervous system. Optoelectronic stimulation supplies, power and signal into the implanted optical detector inside the body by optics. It can be effective strategy especially on the retinal prosthesis, because it enables the non-invasive connection between the external source and internal detector through natural optical window 'eye'. Therefore, we designed an effective neural stimulating setup by optically based stimulation. Stimulating on the sciatic nerve of a rat with proper depth probe through optical stimulation needs higher ratio of current spreading through the neural surface, because of high impedance of neural interface. To increase the insertion current spreading into the neuron, we used a parallel low resistance compared to load resistance organic interface and calculated the optimized outer parallel resistance for maximum insertion current with the assumption of limited current by photodiode. Optimized outer parallel resistance was at a range of 500Ω-700Ω and a current was at a level between 580uA and 650uA. Stimulating current efficiency from initial photodiode induced current was between 47.5 and 59.7%. Various amplitude and frequency of the optical stimulation on the sciatic nerve showed the reliable visual tremble, and the action potential was also recorded near the stimulating area. These result demonstrate that optoelectronic stimulation with no bias can be applied to the retinal prosthesis and other neuroprosthetic area.

Cyclic fatigue resistance, torsional resistance, and metallurgical characteristics of M3 Rotary and M3 Pro Gold NiTi files

  • Pedulla, Eugenio;Lo Savio, Fabio;La Rosa, Giusy Rita Maria;Miccoli, Gabriele;Bruno, Elena;Rapisarda, Silvia;Chang, Seok Woo;Rapisarda, Ernesto;La Rosa, Guido;Gambarini, Gianluca;Testarelli, Luca
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.2
    • /
    • pp.25.1-25.10
    • /
    • 2018
  • Objectives: To evaluate the mechanical properties and metallurgical characteristics of the M3 Rotary and M3 Pro Gold files (United Dental). Materials and Methods: One hundred and sixty new M3 Rotary and M3 Pro Gold files (sizes 20/0.04 and 25/0.04) were used. Torque and angle of rotation at failure (n = 20) were measured according to ISO 3630-1. Cyclic fatigue resistance was tested by measuring the number of cycles to failure in an artificial stainless steel canal ($60^{\circ}$ angle of curvature and a 5-mm radius). The metallurgical characteristics were investigated by differential scanning calorimetry. Data were analyzed using analysis of variance and the Student-Newman-Keuls test. Results: Comparing the same size of the 2 different instruments, cyclic fatigue resistance was significantly higher in the M3 Pro Gold files than in the M3 Rotary files (p < 0.001). No significant difference was observed between the files in the maximum torque load, while a significantly higher angular rotation to fracture was observed for M3 Pro Gold (p < 0.05). In the DSC analysis, the M3 Pro Gold files showed one prominent peak on the heating curve and 2 prominent peaks on the cooling curve. In contrast, the M3 Rotary files showed 1 small peak on the heating curve and 1 small peak on the cooling curve. Conclusions: The M3 Pro Gold files showed greater flexibility and angular rotation than the M3 Rotary files, without decrement of their torque resistance. The superior flexibility of M3 Pro Gold files can be attributed to their martensite phase.