• Title/Summary/Keyword: maximum flow

Search Result 3,397, Processing Time 0.03 seconds

Distributions of 137Cs and 90Sr in the Soil of Uljin, South Korea (울진토양에서의 137Cs 및 90Sr 분포)

  • Song, JiYeon;Kim, Wan;Maeng, Seongjin;Lee, Sang Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.49-55
    • /
    • 2016
  • Background: For the purpose of baseline data collection and enhancement of environmental monitoring the distribution studies of $^{137}Cs$ and $^{90}Sr$ in the soil of Uljin province was performed and the relation between surface soil activities and soil properties (pH, TOC and median of the surface soil) was analyzed. Materials and Methods: For 14 spots within 10 km from the NPP surface soil samples were collected and soils for depth profile were sampled for 3 spots in April 2011. Using ${\gamma}$-ray spectrometry with HPGe detector, the concentrations of $^{137}Cs$ were determined and the concentrations of $^{90}Sr$ were measured by counting ${\beta}$-activity of $^{90}Y$ (in equilibrium with $^{90}Sr$) in a gas flow proportional counter. Results and Discussion: The concentration ranges of $^{137}Cs$ and $^{90}Sr$ were $<0.479-39.6Bq{\cdot}(kg-dry)^{-1}$ (avg. $7.51Bq{\cdot}(kg-dry)^{-1}$) and $0.209-1.85Bq{\cdot}(kg-dry)^{-1}$ (avg. $0.74Bq{\cdot}(kg-dry)^{-1}$) which were similar to the reported values from other regions in Korea. The activity ratio of $^{137}Cs$ to $^{90}Sr$ in surface soils was around 9.67, which is much bigger than the initial value of 1.75 for worldwide fallouts because of faster downward movement of $^{90}Sr$ after fallout than that of $^{137}Cs$. For depth profile studies soils were collected down to 40 cm depth for the locations of Deokgu, Hujeong and Maehwa. The $^{137}Cs$ concentration distribution of the first two showed maximum values at top soils and decreased rapidly in exponential manner, while $^{90}Sr$ showed two local maximum values for soils near top and about 30 cm depth. Through linear fittings between the $^{137}Cs$ and $^{90}Sr$ concentrations of surface soil and pH, TOC and median of the surface soil, the only probable relationship obtained was between $^{137}Cs$ and TOC (determination coefficient $R^2=0.6$). Conclusion: The concentration ranges of $^{137}Cs$ and $^{90}Sr$ in Uljin were similar to the reported values from other regions in Korea. The only probable relationship obtained between activities and soil properties was between $^{137}Cs$ and TOC.

Model of Drying Stress Distribution in Disks End-wrapped in Korean Paper and Effects of End-wrappings on Prevention of Drying Defects for Vacuum Drying of Disks (한지(韓紙) 엔드래핑처리 원판(圓板)의 감압건조응력(減壓乾燥應力) 분포모형(分布模型) 및 엔드래핑스의 건조결함(乾燥缺陷) 예방효과(豫防效果))

  • Lee, Nam-Ho;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.31-63
    • /
    • 1991
  • It was proved that in conventional kiln drying of disks piling position in the kiln exerted a great influence on drying rates, and the larger the variation of disk diameter, the more undulating drying rates of disks. While in vacuum drying disks there was no influence on drying rates. By the end-wrapping treatments and the radial direction of disks tangential surface stresses in the core of disks were slightly compressive in three species. In control disks the drying stresses distributed into one step-style that compressive stresses in the pith side of 6cm from pith were larger than those in the bark side, while in the disks end-wrapped with Korean paper the drying stresses distributed uniformly, because flow rates of free water in disks had no difference between heart-and sap-wood by obstruction of evaporating water from surface of disks by end-wrapping with Korean paper. And end-wrapping with Korean paper considerably restrained those. Tangential differential shrinkage stresses developed the maximum tensile stress near the bark and with approaching the pith the stresses gradually reduced and changed into compressive stresses in near the pith. At the end of vacuum drying the maximum tangential tensile stresses of disks end-wrapped with Korean paper were smaller than those of control disks, and critical moisture contents causing the V-shaped crack of disks end-wrapped with Korean paper were lower than those of control disks because of the set by obstruction of evaporating water of end-wrapping with Korean paper. In the experiment of vacuum drying stress distribution the disks end-wrapped with Korean paper or aluminum foil in three species were free from V-shaped cracks and control disks were defected very slightly by V-shaped cracks. And also disks end-wrapped with Korean paper were free from heart checks in Alnus japonica and Juglans sinensis, and heart checks were occurred very slightly in others. Especially, not to speak of disks end-wrapped with Korean paper, vacuum drying of disks end-wrapped with aluminum foil prevented effectively drying defects, moreover drying times could be shortened, that is. Ginkgo biloba, Alnus japonica, and Juglans sinensis disks could be dried from green to in-use moisture content in 110 hours, 272 hours, and 407 hours, respectively.

  • PDF

Optical Properties of SiNx Thin Films Grown by PECVD at 200℃ (200℃의 저온에서 PECVD 기법으로 성장한 SiNx 박막의 열처리에 따른 광학적 특성 변화 규명)

  • Lee, Kyung-Su;Kim, Eun-Kyeom;Son, Dae-Ho;Kim, Jeong-Ho;Yim, Tae-Kyung;An, Seung-Man;Park, Kyoung-Wan
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.1
    • /
    • pp.42-49
    • /
    • 2011
  • We deposited $SiN_x$ thin films by using PECVD technique at $200^{\circ}C$ with various flow ratios of the $SiH_4/N_2$ gases. The photoluminescence measurements revealed that the maximum emission wavelength shifted to long wavelength as the ratio increased, however, positions of the several peak wavelengths, such as 1.9, 2.2, 2.4, and 3.1 eV, were independent on the ratio. Changes of the photoluminescence spectra were measured in the $N_{2}-$, $H_{2}-$, and $O_2$-annealed films. The luminescence intensities increased after the annealing process. In particular, the maximum emission wavelength shifted to short wavelength after $H_{2}-$ or $O_2$-annealing. But there were still several peaks on the spectra of all annealed films, several peak positions remained to be unchanged after the annealing. As for the light emission mechanism, we have considered the defect states of the Si- and N- dangling bonds in the $SiN_x$ energy gap, so that the energy transitions from/to the conduction/valence bands and the defect states in the gap were attributed to the light emission in the $SiN_x$ films. The experimental results point to the possibility of a Si-based light emission materials for flexible Si-based electro-optic devices.

Sorption of Arsenite Using Nanosized Mackinawite (FeS)-Coated Silica Sand (나노 크기 매킨나와이트로 코팅된 규사를 이용한 아비산염의 흡착)

  • Lee, Seungyeol;Kang, Jung Chun;Park, Minji;Yang, Kyounghee;Jeong, Hoon Young
    • Journal of the Mineralogical Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.185-195
    • /
    • 2012
  • Due to the high reduction and sorption capacity as well as the large specific surface area, nanosized mackinawite (FeS) is useful in reductively transforming chlorinated organic pollutants and sequestering toxic metals and metalloids. Due to the dynamic nature in its colloid stability, however, nanosized FeS may be washed out with the groundwater flow or result in aquifer clogging via particle aggregation. Thus, these nanoparticles should be modified such as to be built into permeable reactive barriers. This study employed coating methods in efforts to facilitate the installation of permeable reactive barriers of nanosized mackinawite. In applying the methods, nanosized mackinawite was coated on non-treated silica sand (NTS) and chemically treated silica sand (CTS). For both silica sands, the maximum coating of mackinawite occurred around pH 5.4, the condition of which was governed by (1) the solubility of mackinawite and (2) the surface charge of both silica and mackinawite. Under this pH condition, the maximum coating by NTS and CTS were found to be 0.101 mmol FeS/g and 0.043 mmol FeS/g respectively, with such elevated coatings by NTS likely linked with impurities (e.g., iron oxides) on its surface. Arsenite sorption experiments were performed under anoxic conditions using uncoated silica sands and those coated with mackinawite at the optimal pH to compare their reactivity. At pH 7, the relative sorption efficiency between uncoated NTS and coated NTS changed with the initial concentration of arsenite. At the lower initial concentration, uncoated NTS showed the higher sorption efficiency, whereas at the higher concentration, coated NTS exhibited the higher sorption efficiency. This could be attributed to different sorption mechanisms as a function of arsenite concentration: the surface complexation of arsenite with the iron oxide impurity on silica sand at the low concentration and the precipitation as arsenic sulfides by reaction with mackinawite coating at the high concentration. Compared to coated NTS, coated CTS showed the lower arsenite removal at pH 7 due to its relatively lower mackinawite coating. Taken together, our results indicate that NTS is a more effective material than CTS for the coating of nanosized mackinawite.

Correlation between Meteorological Factors and Water Discharge from the Nakdong River Barrage, Korea (낙동강 하구역 해양물리환경에 미치는 영향인자 비교분석(I) - 하구둑 방류량과 기상인자 -)

  • Park, San;Yaan, Han-Sam;Lee, In-Cheal;Kim, Hean-Tae
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.14 no.2
    • /
    • pp.111-117
    • /
    • 2008
  • We estirmted the yearly and monthly variation in discharge from the Nakdong River Barrage. We studied the total monthly discharge, the mean daily discharge, and the maximum daily discharge based on the observational discharge data for the 11-year period 1996-2006. We also examined the correlation between the discharge and the meteorologiml factors that influence the river inflow. The results from this study are as follows. (1) The total monthly discharge for 11 years at the Nakdong River Barrage was $224,576.8{\times}10^6\;m^3$: The daily maximum was in 2003, with $56,292.3{\times}10^6\;m^3$. The largest daily mean release discharges occurred in August with $52,634.2{\times}10^6\;m^3$ (23.4% of the year), followed by July and September in that order with 23.1 and 17%, respectively. (2) The monthly pattern of discharge could be divided into the flood season for the period July-September (discharge =$1000{\times}10^6\;m^3$/day), the normal season from April to June and October (discharge=$300{\times}10^6\;m^3$/day), and the drought season from December to March (discharge < $300{\times}10^6\;m^3$/day). (3) Periods of high temperature, low evaporation loss, and short sunshine duration produced a much higher discharge in general. Conditions of low rainfall and high evaporation loss, as was the rose in 2003, tended to reduce the discharge, but high rainfall and low evaporation loss tended to increase the discharge as it did in 200l. (4) The dominant wind directions during periods of high discharge were NNE (15.5%), SW and SSW (13.1%), S(12.1%), and NE (10.8%) This results show that it run bring on accumulation of fresh water when northern winds are dominant, and it run flow out fresh water toward offslwre when southern winds are dominant.

  • PDF

Error Analysis of Image Velocimetry According to the Variation of the Interrogation Area (상관영역 크기 변화에 따른 영상유속계의 오차 분석)

  • Kim, Seojun;Yu, Kwonkyu;Yoon, Byungman
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.8
    • /
    • pp.821-831
    • /
    • 2013
  • Recently image velocimetries, including particle image velocimetry (PIV) and surface image velocimetry (SIV), are often used to measure flow velocities in laboratories and rivers. The most difficult point in using image velocimetries may be how to determine the sizes of the interrogation areas and the measurement uncertainties. Especially, it is a little hard for unskilled users to use these instruments, since any standardized measuring techniques or measurement uncertainties are not well evaluated. Sometimes the user's skill and understanding on the instruments may make a wide gap between velocity measurement results. The present study aims to evaluate image velocimetry's uncertainties due to the changes in the sizes of interrogation areas and searching areas with the error analyses. For the purpose, we generated 12 series of artificial images with known velocity fields and various numbers and sizes of particles. The analysis results showed that the accuracy of velocity measurements of the image velocimetry was significantly affected by the change of the size of interrogation area. Generally speaking, the error was reduced as the size of interrogation areas became small. For the same sizes of interrogation areas, the larger particle sizes and the larger number of particles resulted smaller errors. Especially, the errors of the image velocimetries were more affected by the number of particles rather than the sizes of them. As the sizes of interrogation areas were increased, the differences between the maximum and the minimum errors seemed to be reduced. For the size of the interrogation area whose average errors were less than 5%, the differences between the maximum and the minimum errors seemed a little large. For the case, in other words, the uncertainty of the velocity measurements of the image velocimetry was large. In the viewpoint of the particle density, the size of the interrogation area was small for large particle density cases. For the cases of large number of particle and small particle density, however, the minimum size of interrogation area became smaller.

Evaluation of Pollen Viability of Nakdongbyeo, Two Transgenic Rice Lines, Its Hybrids with Weedy Rice, and Subsequent Selfed Progenies: F2 and F3 (낙동벼, 2개의 promoter를 각각 삽입한 유전자변형 계통과 잡초성벼(Oryza sativa)인공수정 한 후 다음세대인 F1, F2, F3의 화분활력 평가)

  • Ghimire, Sita Ram;Sohn, Eun-Young;Shin, Dong-Hyun;Lee, In-Jung;Kim, Kil-Ung
    • Journal of Life Science
    • /
    • v.19 no.7
    • /
    • pp.839-844
    • /
    • 2009
  • This experiment was conducted to evaluate pollen viability of Nakdongbyeo, transgenic rice lines, an F$_1$ hybrid from a cross between Milyang weedy rice and ABC-promoter transgenic rice line containing basta-resistant (bar) gene and subsequent selfed progenies, F$_2$ and F$_3$. The reaction of pollen with 3-{4,5 dimethylthiazolyl-2}-2,5-diphenyl monotetrazolium bromide (MTT) as a staining chemical immediately after pollen shedding showed maximum pollen viability of 86% in Nakdongbeyo, 75% in ABC-promoter transgenic rice line, 62% in ubiquitin-promoter transgenic line, 68% in F$_1$, 79% in F$_2$ and 78% in F$_3$. Viability gradually declined during subsequent observations at 20-minute intervals. However, there was a drastic decline in pollen viability after 40 minutes of pollen shedding. The mean difference of pollen viability among rice lines and time was highly significant, indicating significantly different pollen viabilities at different time intervals. Maximum viability of 36.2% was observed in F$_3$ and minimum viability of 3.5% was found in F$_2$ at 90 min after pollen shedding. Results of this experiment on pollen viability and longevity elucidate potential risks of pollen-mediated flow of herbicide-resistant gene from transgenic rice lines and possible integration of it into the weedy rice population.

A review on the design requirement of temperature in high-level nuclear waste disposal system: based on bentonite buffer (고준위폐기물처분시스템 설계 제한온도 설정에 관한 기술현황 분석: 벤토나이트 완충재를 중심으로)

  • Kim, Jin-Seop;Cho, Won-Jin;Park, Seunghun;Kim, Geon-Young;Baik, Min-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.587-609
    • /
    • 2019
  • Short-and long-term stabilities of bentonite, favored material as buffer in geological repositories for high-level waste were reviewed in this paper in addition to alternative design concepts of buffer to mitigate the thermal load from decay heat of SF (Spent Fuel) and further increase the disposal efficiency. It is generally reported that the irreversible changes in structure, hydraulic behavior, and swelling capacity are produced due to temperature increase and vapor flow between $150{\sim}250^{\circ}C$. Provided that the maximum temperature of bentonite is less than $150^{\circ}C$, however, the effects of temperature on the material, structural, and mineralogical stability seems to be minor. The maximum temperature in disposal system will constrain and determine the amount of waste to be disposed per unit area and be regarded as an important design parameter influencing the availability of disposal site. Thus, it is necessary to identify the effects of high temperature on the performance of buffer and allow for the thermal constraint greater than $100^{\circ}C$. In addition, the development of high-performance EBS (Engineered Barrier System) such as composite bentonite buffer mixed with graphite or silica and multi-layered buffer (i.e., highly thermal-conductive layer or insulating layer) should be taken into account to enhance the disposal efficiency in parallel with the development of multilayer repository. This will contribute to increase of reliability and securing the acceptance of the people with regard to a high-level waste disposal.

Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy (Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가)

  • Yeon, Joon-Ho;Kim, Soo-Yung;Choi, Sung-Ook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.76-82
    • /
    • 2011
  • Purpose: Lymphoscintigraphy is absolutely being used standard examination in lymphatic diagnosis, evaluation after treatment, and it is useful for lymphedema to plan therapy. In case of lymphoscintigraphy of lower-extremity lymphedema, it had an effect on results if patients had not pose same position on the examination of 1 min, 1 hour and 2 hours after injection. So we'll study the methods to improve confidence with minimized quantitative analysis errors by influence factors. Materials and Methods: Being used the Infinia of GE Co. we injected $^{99m}Tc$-phytate 37 MBq (1.0 mCi) 4 sylinges into 40 people's feet hypodermically from June to August 2010 in Samsung Medical Center. After we acquired images of fixed and unfixed condition, we confirmed the count values change by attenuation of soft tissue and bone according to different feet position. And we estimated 5 times increasing 2 cm of distance between $^{99m}Tc$ point source and detector each time to check counts difference according to distance change by different feet position. Finally, we compared 1 and 6 min lymphoscintigraphy images with same position to check the effect of quantitative analysis results owing to difference of amounts of movement of the $^{99m}Tc$-phytate in the lymphatic duct. Results: Percentage difference regarding error values showed minimum 2.7% and maximum 25.8% when comparing fixed and unfixed feet position of lymphoscintigraphy examination at 1 min after injection. And count values according to distance were 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm) which distance was increased interval of 2 cm and basal value was mean 176,587 counts, and percentage difference values were not over 2.5% such as 1.27, 1.79, 2.04, 2.42, 2.35%. Also, Assessment results about amounts of movement in lymphatic duct within 6 min until scanning after injection showed minimum 0.15%, and maximum 2.3% which were amounts of movement. We can recognize that error values represent over 20% due to only attenuation of soft tissue and bone except for distance difference (2.42%) and amounts of movement in lymphatic duct (2.3%). Conclusion: It was show that if same patients posed different feet position on the examination of 1 min, 1 hour and 2 hours after injection in the lymphoscintigraphy which is evaluating lymphatic flow of patients with lymphedema and analyzing amount of intake by lymphatic system, maximum error value represented 25.8% due to attenuation of soft tissue and bone, and PASW (Predictive Analytics Software) showed that fixed and unfixed feet position was different each other. And difference of distance between detector and feet and change of count values by difference of examination beginning time after injection influence on quantitative analysis results partially. Therefore, we'll make an effort to fix feet position and make the most of fixing board in lymphoscintigraphy with quantitative analysis.

  • PDF

Effect of Physical Training on Pulmonary Function (체력단련(體力鍛鍊)이 폐기능(肺機能)에 미치는 효과(效果))

  • Nam, Pal-Soo;Hwang, Soo-Kwan;Kim, Hyeong-Jin;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.15 no.1
    • /
    • pp.37-43
    • /
    • 1981
  • In the present study, an effort was directed to elucidate the effect of the physical training on the pulmonary function. Twenty-four male athletics major students who have undergone regular physical training for more than five years were randomly chosen as the athletic subjects, and 12 regular male students who have not been engaged in any form of regular physical exercise or training were chosen as the non-athletic subjects, and a comparison was made between the two groups. The following were mainly observed by spirometry for the study; respiratory rate, tidal volume, vital capacity, maximum voluntary ventilation(MVV), forced expiratory volume for 1 second$(FEV_1)$, percent $FEV_1$ to forced vital capacity$(FEV_1%)$, forced expiratory flow for initial 1 liter$(FEF_{0.2-1.2}L)$, and forced mid-expiratory flow$(FEF_{\;25-75}%)$. The results obtained are summarized as follow. 1) The respiratory rate, tidal volume, and vital capacity showed no significant difference between athletes and non-athletes. The MVV in athletes was significantly (p<0.01) increased to $148.1{\pm}3.1\;L/min$ comparing with $118.3{\pm}9.1\;L/min$ in non-athletes. 2) $FEV_1$ was $3.310{\pm}0.070\;L$ in athletes and $2.779{\pm}0.104$ in non-athletes; $FEV_1%\;83.63{\pm}1.29%$ in athletes and $75.33{\pm}1.75%$ in non-athletes, both showing significant(p<0.01) increase in athletes. 3) $FEF_{0.2-1.2}L$ was $297.1{\pm}13.5\;L/min in athletes and $222.7{\pm}15.0\;L/min$ in non-athletes; $FEF_{\;25-75}%$ was $3.543{\pm}0.109\;L/sec$ in non-athletes, both showing significant(p<0.01) increase in athletes. 4) Some discussions were made on these results. The lung volumes showed no significant difference between the two groups. But MVV, $FEV_1$, $FEV_1%$, $FEF_{0.2-1.2}L$ and $FEF_{25-75}%$ in athletes were significantly(p<0.01) higher than in non-athletes. It is therefore concluded that the athletes have more powerful respiratory muscles, or higher compliance of the lung and thorax than the non-athletes.

  • PDF