• 제목/요약/키워드: maximum blood pressure

검색결과 141건 처리시간 0.025초

주기별 맥동파형의 절흔점 위치변화 특성을 이용한 혈압 추정 (Estimation of the Blood Pressure Using Point Variation Aspect of Dicrotic Notch on Pulsating Waveform at Each Cardiac Periods)

  • 백승완;박성민;손정만;박근철;이상훈;장우영;전아영;전계록
    • 센서학회지
    • /
    • 제22권2호
    • /
    • pp.136-143
    • /
    • 2013
  • In the study, novel blood pressure estimation method was proposed to improve the accuracy of oscillometric method. The proposed algorithm estimated the blood pressure by comparing and analyzing the point variation aspect of dicrotic notch on pulsating waveform during each cardiac cycle. The waveforms of each cardiac cycle were extracted by maximum points. The extracted pulsating waveforms were applied by re-sampling, end-matching, and normalization. The systolic and diastolic blood pressures were estimated by point variation aspect of dicrotic notch. The blood pressures, which were estimated from proposed algorithm, were compared and analyzed by blood pressures from oscillometric methods and auscultation. The systolic blood pressure from oscillometric methods were +0.88 mmHg more than proposed algorithm, and 1.875 less than the diastolic blood pressures from proposed algorithm. The systolic and diastolic blood pressures from auscultation were 2.89 mmHg and 3.44 mmHg less than the blood pressures from proposed algorithm. As the errors between blood pressures from proposed algorithm, oscillometric method and auscultation were less than 5 mmHg, the proposed algorithm was effective.

혈압 측정을 위한 외팔보형 접촉힘 센서 어레이 (A Cantilever Type Contact Force Sensor Array for Blood Pressure Measurement)

  • 이병렬;정진우;전국진
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.121-126
    • /
    • 2012
  • Piezoresistive type contact force sensor array is fabricated by (111) Silicon bulk micromachining for continuous blood pressure monitoring. Length and width of the unit sensor structure is $200{\mu}m$ and $190{\mu}m$, respectively. The gap between sensing elements is only $10{\mu}m$. To achieve wafer level packaging, the sensor structure is capped by PDMS soft cap using wafer molding and bonding process with $10{\mu}m$ alignment precision. The resistance change over contact force was measured to verify the feasibility of the proposed sensor scheme. The maximum measurement range and resolution is 900 mm Hg and 0.57 mm Hg, respectively.

무선통신기술과 MAA 알고리즘을 이용한 휴대형 혈압측정 시스템 구현 (Implementation of the Potable Blood Pressure Measurement System Using Wireless Communication Technology and MAA Algorithm)

  • 김보성;김세진;정도운
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 춘계종합학술대회
    • /
    • pp.678-681
    • /
    • 2007
  • 본 연구에서는 오실로메크릭법에 의한 혈압측정을 위하여 비관혈적인 방법으로 보다 정확하게 혈압을 추정할 수 있는 시스템을 구현하였다. 구현된 혈압 측정 시스템은 압력 제어부, 신호 측정부 그리고 혈압 신호처리부, 무선센서네트워크부 등으로 구성하였다. 구현된 혈압측정 실험 시스템의 타당성을 검증하기 위하여 압력 측정부의 특성 평가 실험, 혈압 추정을 위한 특성비율 산출 실험, 오실로 메트릭법에 의한 혈압 추정 및 평가 실험을 수행하였다. 본 연구에서 구현된 혈압 측정 실험 시스템으로 성인남성 5명을 실험 대상군으로 선정하여 데이터를 계측하고 혈압을 추정하는 실험을 한 결과 오실로메트릭에 의한 혈압 추정 및 평가 실험에서 청진법과의 평균동맥압, 수축기 혈압, 그리고 이완기 혈압에서 최대 절대편차 비율이 각각 1.38 %, 1.63 그리고 2.97 % 이었고 최대 표준오차가 각각 5.00, 3.72, 그리고 4.34인 혈압 측정 시스템을 구현하였다.

  • PDF

한국 인슐린 비의존형 당뇨병 환자의 체중 변화, 체지방, 혈압 및 C-peptide/혈당 비 (Past and Present Obesity, Parameters of Body Fat and Blood Pressure in Korean Patients with Non-Insulin Dependent Diabetes Mellitus(NIDDM))

  • 박혜자;이인옥;김세현
    • 대한간호학회지
    • /
    • 제31권6호
    • /
    • pp.1034-1043
    • /
    • 2001
  • To determine the frequency of past and present obesity among patients with NIDDM and to identify the differences of body fat, blood pressure and C-peptide/glucose ratio according to obese diabetic patients (BMI$\geq$25 kg/$m^2$) and nonobese (BMI<25 kg/$m^2$). Also the final factor is to observe the anthrometric change patterns in the study. Method: The weight at 20 years-old, previous maximal body weight, and acute weight loss were queried. Current height, body weight, BMI, waist & hip circumferences, waist-hip ratio, skinfold thicknesses, blood pressure, fasting blood glucose, and fasting C-peptide were measured in one hundred sixty-seven NIDDM patients. The differences of the parameters ccording to obese and nonobese, and three anthropometric change patterns were analyzed. Result: Results were as follows: 1. 66.5 % of the NIDDM patients had a history of past obesity as assessed by their maximum weight, while only 33.2% of them were currently obese (p's < 0.001). 2. The waist & hip circumferences, skinfold thicknesses, systolic, diastolic & mean arterial blood pressure in obese patients were greater than those of nonobese patients (all p's < 0.001). 3. The waist and the hip circumferences, and skinfold thicknesses (subscapula & triceps) were highest among the obese-obese group. WHR and abdominal skinfold thickness in the obese-obese and obese-nonobese groups were higher than those in the nonobese- nonobese group. Systolic & diastolic and mean arterial blood pressures in the obese-obese group were higher than those of obese-nonobese and nonobese-nonobese groups(all p's < 0.005). 4. The abdominal and subscapular skinfold thicknesses in female diabetic patients were greater than those of male patients (all p's <0.0001). Conclusion: Although most Korean NIDDM patients were previously obese, many of them were not obese during the course of the study. Greater central and upper body adiposicity and higher blood pressure was shown in obese diabetic patients. Also, greater central and upper body adiposicity was demonstrated in female diabetic patients.

  • PDF

8주간의 강도별 웨이트트레이닝이 비만고교생의 대사증후군 인자 개선에 미치는 영향 (The Effects of Weight Training by Intensity for 8 Weeks of Metabolic Syndrome Factor Improvement in Overweight High School Students)

  • 정선태;권선옥
    • 생명과학회지
    • /
    • 제19권4호
    • /
    • pp.492-501
    • /
    • 2009
  • 일반계 비만고교생 60명을 4그룹으로 구분, 웨이트트레이닝을 1일 60${\sim}$70분, 주 3회, 8주간 강도별(A group: control group, B group: $40{\sim}55%RM$, C group: $60{\sim}75%RM$, D group: $80{\sim}90%RM$)로 실시하여 대사증후군 5가지 인자(waist size, fasting glucose, TG, HDL-C, blood pressure) 개선을 위한 가장 효과적인 WT 강도를 알아보았다. Waist size의 감소는 운동군 모두 효과적이었으나 $40{\sim}55%RM$$60{\sim}75%RM$ 실시 그룹이 더욱 효과적이었고, TG의 감소도 운동군 모두 효과적이었으나 $40{\sim}55%RM$ RM 실시 그룹이 더욱 효과적이었다. Fasting glucose는 차이가 없었으며, HDL-C는 대조군보다 $80{\sim}90%RM$ 실시 그룹이 유의하게 증가하였고, blood pressure는 diastolic blood pressure는 차이가 없었고, systolic blood pressure는 다른 그룹보다 $40{\sim}55%RM$ 실시 그룹이 유의하게 감소하였다. 이러한 결과는 중 고강도보다는 오히려 저강도가 대사증후군 인자 개선에 효과적이라는 것을 시사하며, 웨이트트레이닝이 비만고교생의 대사증후군 위험 인자를 개선해준다는 사실을 확인하였다. 따라서, 비만고교생은 대사증후군 인자의 개선을 위해 $40{\sim}55%\;RM$의 웨이트트레이닝을 실시하는 것이 효과적이라 생각된다.

Determination of blood concentration of higenamine by high pressure liquid chromatography

  • Park, Sun-Oak;Hong, Chang-Yee;Paik, Seung-Whan;YunChoi, Hye-Sook
    • Archives of Pharmacal Research
    • /
    • 제10권1호
    • /
    • pp.60-66
    • /
    • 1987
  • A procedure utilizing high pressure liquid chroatography coupled with UV detection is described for the determination of blood concentration of higenamine. Deproteinized serum was pretreated with$C_{18}$(Sep-pak $C_{18}$ cartridge) and the 70% EtOH eluent was applied onto a reversed-phase column ($\mu$ Bondapak $C_{18}]$) with a 15% acetonitrile in 0.05 N $NaH_2$$PO_4$-trichloroacetic acid mixed buffer (pH 2.8) as a mobile phase. With the UV detection at 232 nm, the retention times of higenamine and 1, 2, 3, 4-tetrahydropapaveroline, an internal standard, were 5.2 min and 3.9 min respectively. The blood concentration of higenamine was meausred at regular intervals after i. v. injection of higenamine to rabbit. A drastic decrease in higenamine concentration to 30% of the maximum value obtained immediately after the injection, was observed during the first 1-2 min period and thereafter the rate of decrease was slowed down. The analytical result seemed to coincide with the pharmacological effect of higenamine exerting the maximum chronotropic and hypotensive effect at the completion of the injections which were progressively recovered.

  • PDF

SHR에 $\alpha-Methyldopa$를 Timolol 또는 Labetalol과 병용투여시 혈압강하효과에 관한 연구 (Antihypertensive Effect of $\alpha-Methyldopa$ Administered Concurrent with Timolol or Labetalol in SHR.)

  • 김종기;허인회;김재완
    • 약학회지
    • /
    • 제25권2호
    • /
    • pp.57-64
    • /
    • 1981
  • The antihypertensive effect of $\alpha-Methyldopa$ administered concurrently with timolol or labetalol were studied with spontaneously hypertensive rats (SHR). Every drugs were administered orally once a day after prechecking the systolic blood pressure and heart rate of SHR. The blood pressure and heart rate of SHR were significantly decreased in groups of combination while those of non-combination groups were fallen slightly. Compared with control group, the significant changes of blood pressure was obseved in group of $\alpha-methyldopa$ with timolol(100mg+2mg/kg)and $\alpha-methyldopa$ with labetalol (100mg+12.5mg/kg). The group of $\alpha-methyldopa$ with timolo 1 (100mg + 1.0mg/kg) reduced blood Pressure in similar degree as manifested in group of $\alpha-methyldopa$ with labetalol (100mg + 50mg/kg). In the group that $\alpha-methyldopa$ was administered concurrently with timolol, the maximum antihypertensive effect and heart rate decreasing effect were appeared after 3hr and 1hr of administration respectively and those effects in group of $\alpha-methyldopa$ with labetalol were appeared after 6hr of administration. The acute oral toxicity test was performed using albino mice with $\alpha-methyldopa$ alone, $\alpha-methyldopa$ with timolol (100:1) and $\alpha-methyldopa$ with labetatol (4:1), and was found that the $LD_{50}$ of $\alpha-methyldopa$ alone was 1104 mg/kg, $\alpha-methyldopa$ with timolol (100:1) was 1115 mg/kg and $\alpha-methyldopa$ with labetalol (4:1) was 354mg/kg.

  • PDF

모듈방식의 가정용 혈압 측정 시스템 구현 (An Implementation of Non-invasive Blood Pressure System Using Variable Characteristic Ratio)

  • 이종수;노영아;이상용;박종억;김영길
    • 한국정보통신학회논문지
    • /
    • 제5권7호
    • /
    • pp.1263-1271
    • /
    • 2001
  • There are two methods in blood pressure measurement ; Invasive methode and Non-invasive method. The Invasive methode can get the 띠cod pressure measurement but, patient feel uncomfortable. So Non-invasive methode used generally. The Oscillometric method is typical Non-Invasive method. This method is commonly used to measure BP in electric sphygmomanometer and has various algorithm. In this paper it is described about a algorithm, it controls, determinates the cuff pressure, and fillers the measured BP data. This system can interface with PC(personal computer) by RS-232 and save the measured data in PC. This system deflates the cuff pressure by Solenoid valve. The main algorithm are oscillometric and maximum amplitude algorithm(MAA). MAA has various measured oscillation, it depends on patient's age, height, weight and arm circumference size. In this paper proposed system can measure Systolic BP, Diastolic BP, and Mean BP using Interpolation, Auto Reinflation algorithm.

  • PDF

비신축성 코르셋의 의복압으로 인한 생리적 반응의 변화 (Changes in Physiological Responses by the Pressure of Non-Elastic Corset)

  • 나영주;김양희
    • 한국의류산업학회지
    • /
    • 제13권6호
    • /
    • pp.943-951
    • /
    • 2011
  • The purpose of this study is to analyze the physiological effects of non-elastic corset on women's health and pain through measuring the clothing pressure, subjective pressure sensation, blood velocity and metabolism. 5 women in their twenties were picked as our subjects, their average size being 85cm at bust girth, 69 cm at waist girth. With the subjects each wearing a corset, we are testing in artificial environment with a treadmill according to the planned exercise procedures. The average pressure of the corset is 0.938 kPa (maximum 3.006 kPa at 45 degree front bowing), which is 10.2 times higher than the control group, averaging from 9.3 times higher at resting, 11.4 times at walking, 11.1 times at running. The effect of corset pressure on the physiological responses of the body is increased more when exercise than when resting. Clothing pressure increased in the order of the postures: sitting > standing with 45 degree bowing > standing. They experienced a high level of tighten discomfort of 5.6 in the scale of 1.0 to 7.0 due to the high pressure of the corset when resting, after intense exercise the level increased to 6.0, while without corset the level increased 1.7 to 2.2. With corset on, the blood circulation did not increase even though when the body exercised and blood flow became unbalanced making great gaps between both at the right and left finger tips. Perspiration of chest and back decreased 37.3% when wearing corset; 27.5% at resting, 56.7% at walking, 25.8% at running, and 39.0% at recovery. With corset on oxygen consume and metabolism increased 9.0%, 7.9%, respectively, which means the corset makes the body uncomfortable. Lung volume exchange VE decreased almost 4.1~7.3% with corset on and $VCO_2/VO_2$, RER and total volume in lung, VT also decreased too, which means the digestion of stomach and lung function are inhibited due to the high corset pressure.

비뉴턴 유체의 협착관내 압력손실계수에 관한 연구 (A study on the pressure loss coefficient of non-Newtonian fluids in the stenotic tubes)

  • 서상호;유상신;장남일
    • 대한기계학회논문집B
    • /
    • 제20권5호
    • /
    • pp.1603-1612
    • /
    • 1996
  • The pressure loss coefficient of Newtonian and non-Newtonian fluids such as water, aqueous solutions of Carbopol-934 and Separan AP-273 and blood in the stenotic tubes are determined experimentally and numerically. The numerical analyses for flows of non-Newtonian fluids in the stenotic tubes are conducted by the finite element method. The effect of the contraction ratio and the ratio of length to diameter on the pressure drop are investigated by the experiments and numerical analysis. The pressure loss coefficients are significantly dependent upon the Reynolds number in the laminar flow regime. As Reynolds number increases, the pressure loss coefficients of both Newtonian and non-Newtonian fluids decrease in the laminar flow regime. As the ratio of length to diameter increases the maximum pressure loss coefficient increases in the laminar flow regime for both Newtonian and non-Newtonian fluids. Newtonian fuid shows the highest values of pressure loss coefficient and blood the next, followed by Carbopol solution and Separan solution in order. Experimental results are used to verify the numerical analyses for flows of Newtonian and non-Newtonian fluids. Numerical results for the maximum pressure loss coefficient in the stenotic tubes are in fairly good agreement with the experimental results. The relative differences between the numerical and experimental results of the pressure loss coefficients in the laminar flow regime range from 0.5% to 14.8%.