• Title/Summary/Keyword: maxillofacial prosthodontics

Search Result 299, Processing Time 0.028 seconds

The effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns (다양한 부위에서의 감소된 두께가 지르코니아 크라운의 파절 저항에 미치는 영향)

  • Abukabbos, Layla;Park, Je Uk;Lee, Wonsup
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.135-142
    • /
    • 2022
  • Purpose. This study aims to evaluate the combined effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns. Materials and methods. Seven nickel-chromium dies were generated from a 3D model of mandibular first molar using the digital scanner with the following geometries: 1.5 mm occlusal reduction, 1.0 mm deep chamfer. Based on the abutment model, Zirconia blocks (Luxen Zirconia) were selected to fabricate Sixty-three zirconia crowns with occlusal thicknesses of 0.3 mm, 0.5 mm, and 1.5 mm, and different axial thicknesses of 0.3 mm, 0.5 mm, and 1.0 mm. All crowns were cemented by resin cement. Next, the crowns were subjected to load-to-fracture test until fracture using an electronic universal testing machine. In addition, fracture patterns were observed with a scanning electron microscope (SEM). Two-way ANOVA and the Tuckey HSD test for post hoc analysis were used for statistical analysis (P < .05). Results. The mean values of fracture resistancerecorded was higher than the average biting force in the posterior region. The two-way ANOVA showed that the occlusal and axial thickness affected the fracture resistance significantly (P < .05). However, the effect of axial thickness on fracture resistance did not show a statistical difference when thicker than 0.5 mm. The observed failure modes were partial or complete fracture depending on the severity of crack propagation. Conclusion. Within the limitations of the present study, the CAD-CAM monolithic zirconia crown with extremely reduced thickness showed adequate fracture resistance to withstand occlusal load in molar regions. In addition, both occlusal and axial thickness affected the fracture resistance of the zirconia crown and showed different results as combined.

Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current

  • Gaeta-Araujo, Hugo;Nascimento, Eduarda Helena Leandro;Fontenele, Rocharles Cavalcante;Mancini, Arthur Xavier Maseti;Freitas, Deborah Queiroz;Oliveira-Santos, Christiano
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • Purpose: This study was performed to evaluate the magnitude of artifacts produced by gutta-percha and metal posts on cone-beam computed tomography (CBCT) scans obtained with different tube currents and with or without metal artifact reduction (MAR). Materials and Methods: A tooth was inserted in a dry human mandible socket, and CBCT scans were acquired after root canal instrumentation, root canal filling, and metal post placement with various tube currents with and without MAR activation. The artifact magnitude was assessed by the standard deviation (SD) of gray values and the contrast-to-noise ratio (CNR) at the various distances from the tooth. Data were compared using multi-way analysis of variance. Results: At all distances, a current of 4 mA was associated with a higher SD and a lower CNR than 8 mA or 10 mA (P<0.05). For the metal posts without MAR, the artifact magnitude as assessed by SD was greatest at 1.5 cm or less (P<0.05). When MAR was applied, SD values for distances 1.5 cm or closer to the tooth were reduced (P<0.05). MAR usage did not influence the magnitude of artifacts in the control and gutta-percha groups(P>0.05). Conclusion: Increasing the tube current from 4 mA to 8 mA may reduce the magnitude of artifacts from metal posts. The magnitude of artifacts arising from metal posts was significantly higher at distances of 1.5 cm or less than at greater distances. MAR usage improved image quality near the metal post, but had no significant influence farther than 1.5 cm from the tooth.

Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines (이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.184-190
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for one periapical radiography using the portable and wall type dental X-ray machines. Materials and methods: Thermoluminescent chips were placed at 25 sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable and wall type dental X-ray machines. For one periapical radiography taken by portable dental X-ray machine, the exposure setting was 60 kVp, 2 mA and 0.2 seconds, while for one periapical radiography taken by wall type dental X-ray machine, exposure setting was 70 kVp, 8 mA and 0.074 seconds. Absorbed dose measurements were performed and equivalent doses to individual organs were summed using ICRP 103 to calculate effective dose. Results: In the upper anterior periapical radiography using portable dental X-ray machine and in the lower posterior periapical radiography using both machines, the highest absorbed dose was recorded at the mandible body. The effective dose in upper anterior periapical radiography using portable and wall type dental X-ray machines was $4{\mu}Sv$, $2{\mu}Sv$, respectively. In the lower posterior periapical radiography, the effective dose for each portable and wall type dental X-ray machines was $6{\mu}Sv$, $2{\mu}Sv$. Conclusion: It was recommended that the operator use prudently potable dental X-ray machine because that the effective dose in the periapical radiography using wall type dental X-ray machine was lower than that in the periapical radiography using portable dental X-ray machine.

Consideration for the Importance of Diseases Associated with Oral Medicine by Analyzing the Dental Cyber Consultation (사이버 치과 진료 상담을 통해 살펴본 구강내과 질환의 중요성에 대한 고찰)

  • Kim, Su-Beom;Jeong, Jae-Yong;Kim, Cheul;Kim, Young-Jun;Park, Moon-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.4
    • /
    • pp.317-322
    • /
    • 2008
  • The moderners of industrial society suffer from various stresses, which bring about increase in prevalence of temporomandibular disorders, oral mucosal disease and chronic neuropathic pain, therefore, the number of patients seeking help of those symptoms tend to increase. The purpose of this study was to discuss the importance of oral medicine related disease by investigating questions that appeared in cyber consultation of Kangnung National University Dental Hospital web site. Among the nearly 2000 questions, the rate of questions related to oral medicine was 20.92%, and the rate of questions related to other departments were oral and maxillofacial surgery 16.87%, conservative dentistry 16.67%, orthodontics 14.02%, prosthodontics 12.25%, periodontics 8.36%, pediatric dentistry 4.93%, preventive dentistry 2.08% and otherwise questions 3.90%. Among the 403 questions related to oral medicine, the frequent questions were oral mucosal diseases 44.17%, temporomandibular disorders 41.19%, halitosis 4.47%, xerostomia 3.23%, other orofacial pain 2.23%, forensic dentistry 1.49% and otherwise questions 2.98%. From the higher rate of questions related to oral medicine compared with other fields of dentistry, we would consider that the people are considerably concerned about the oral medicine related disease, such as oral mucosal diseases and temporomandibular disorders.

Radiographic Evaluation of Condyle Position at Maximum Intercuspal Position Using Cone-beam CT (Cone-beam CT를 이용한 최대교두간접촉위(MIP)에서 과두 위치에 대한 방사선적 평가)

  • Oh, Sang-Chun;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.111-120
    • /
    • 2010
  • Purpose: This investigation was designed to evaluate the condyle position and the symmetry of the both condyle heads at the maximum intercuspal position on the sagittal CT image of the temporomandibular joint. Materials and Methods: Cone-beam CT was used to assess 400 joints in 100 symptom and 100 symtom-free subject(100 male, 100 female). Three independent observers(dentists) determined the positions classified with Anterior Position(AP), Middle Position(MP), and Posterior Position(PP), and the symmetry of the both condyle. Results: According to gender, the mean percentages of AP, MP, and PP were 48.5, 28.5, and 23 in male group, and 34, 38, and 28 in female group. The symmetry of condylar heads was more common than asymmetry in the both of groups. In the respect of symptom or symptom-free, the mean percentages of AP, MP, and PP were 44.5, 34, and 21.5 in the symptom-free group, and 37, 33.5, and 29.5 in the symptom group. The symmetry of condylar heads was more common in the symptom-free group, but the asymmetry of condylar heads was more common in the symptom group. Conclusions: These data might serve as useful criteria for the clinical assessment of condyle position at the maximum intercuspal position optained by Cone-beam CT.

What is the effect of initial implant position on the crestal bone level in flap and flapless technique during healing period?

  • Al-Juboori, Mohammed Jasim;Ab Rahman, Shaifulizan;Hassan, Akram;Ismail, Ikmal Hisham Bin;Tawfiq, Omar Farouq
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.4
    • /
    • pp.153-159
    • /
    • 2013
  • Purpose: The level of the implant above the marginal bone and flap design have an effect on the bone resorption during the healing period. The aim of this study is to detect the relationship between the level of the implant at the implant placement and the bone level at the healing period in the mesial and distal side of implants placed with flapless (FL) and full-thickness flap (FT) methods. Methods: Twenty-two nonsubmerged implants were placed with the FL and FT technique. Periapical radiographs were taken of the patient at implant placement, and at 6 and 12 weeks. By using computer software, bone level measurements were taken from the shoulder of the healing cap to the first bone implant contact in the mesial and distal side of the implant surface. Results: At 6 weeks, the correlation between the crestal bone level at the implant placement and crestal bone level of the FT mesially was significant (Pearson correlation coefficient=0.675, P<0.023). At 12 weeks, in the FT mesially, the correlation was nonsignificant (Spearman correlation coefficient=0.297, P<0.346). At 6 weeks in the FT distally, the correlation was nonsignificant (Pearson correlation coefficient=0.512, P<0.107). At 12 weeks in the FT distally, the correlation was significant (Spearman correlation coefficient=0.730, P<0.011). At 6 weeks in the FL mesially, the correlation was nonsignificant (Spearman correlation coefficient=0.083, P<0.809). At 12 weeks in the FL mesially, the correlation was nonsignificant (Spearman correlation coefficient= 0.062, P<0.856). At 6 weeks in the FL distally, the correlation was nonsignificant (Spearman correlation coefficient=0.197, P<0.562). At 12 weeks in the FL distally, the correlation was significant (Pearson correlation coefficient=0.692, P<0.018). Conclusions: A larger sample size is recommended to verify the conclusions in this preliminary study. The bone level during the healing period in the FT was more positively correlated with the implant level at implant placement than in the FL.

In vitro Antibacterial Effect of Orthodontic Adhesives Mixed with Silver Nanoparticles

  • Choi, Kwon-Yong;Lee, Jong-Chan;Hwang, Yun-Chan;Chang, Seok-Woo;Kum, Kee-Yeon;Bae, Kwang-Shik;Lim, Bum-Soon;Paeng, Jun-Young;Kim, Eun-Cheol;Kwon, Ho-Beom;Kim, Young-Ho
    • Journal of Korean Dental Science
    • /
    • v.5 no.1
    • /
    • pp.7-12
    • /
    • 2012
  • Purpose: To examine the antibacterial effectiveness of silver nanoparticles (SNP) mixed with commercial orthodontic adhesives. Materials and Methods: SNP was prepared by dissolving silver perchlorate in an organic solvent and reducing it with ultraviolet radiation. SNP was then mixed with four commercial orthodontic adhesives (Light Bond, Blugloo, Transbond XT, and Fuji Ortho LC) (0.05 wt %), which were then formed into disc-shape specimens ($8.0mm{\times}3.0mm$). Commercial orthodontic adhesives containing no SNP were used as the control groups. Specimens of the four experimental and four control groups were incubated with streptococcus mutans and the medium turbidity was assessed at 3, 6, 9, 12, and 24 hours after incubation. The agar diffusion test was also performed to examine the growth inhibition zone of these groups. The data were statistically analyzed using a Wilcoxon rank sum test and t-test with a Bonferroni's correction (P<0.05). Result: The SNP containing groups had a superior antibacterial effect compared to the control groups. In the agar diffusion test, the control groups without SNP did not produce an inhibition zone, whereas the SNP containing groups showed inhibition zone of 10~13 mm. Conclusion: The incorporation of SNP into orthodontic adhesives can inhibit cariogenic bacterial growth.

Clinical Evaluation of Guided Bone Regeneration Using 3D-titanium Membrane and Advanced Platelet-Rich Fibrin on the Maxillary Anterior Area (상악 전치부 3D-티타늄 차폐막과 혈소판농축섬유소를 적용한 골유도재생술의 임상적 평가)

  • Lee, Na-Yeon;Goh, Mi-Seon;Jung, Yang-Hun;Lee, Jung-Jin;Seo, Jae-Min;Yun, Jeong-Ho
    • Implantology
    • /
    • v.22 no.4
    • /
    • pp.242-254
    • /
    • 2018
  • The aim of the current study was to evaluate the results of horizontal guided bone regeneration (GBR) with xenograf t (deproteinized bovine bone mineral, DBBM), allograf t (irradiated allogenic cancellous bone and marrow), titanium membrane, resorbable collagen membrane, and advanced platelet-rich fibrin (A-PRF) in the anterior maxilla. The titanium membrane was used in this study has a three-dimensional (3D) shape that can cover ridge defects. Case 1. A 32-year-old female patient presented with discomfort due to mobility and pus discharge on tooth #11. Three months after extracting tooth #11, diagnostic software (R2 GATE diagnostic software, Megagen, Daegu, Korea) was used to establish the treatment plan for implant placement. At the first stage of implant surgery, GBR for horizontal augmentation was performed with DBBM ($Bio-Oss^{(R)}$, Geistlich, Wolhusen, Switzerland), irradiated allogenic cancellous bone and marrow (ICB $cancellous^{(R)}$, Rocky Mountain Tissue Bank, Denver, USA), 3D-titanium membrane ($i-Gen^{(R)}$, Megagen, Daegu, Korea), resorbable collagen membrane (Collagen $membrane^{(R)}$, Genoss, Suwon, Korea), and A-PRF because there was approximately 4 mm labial dehiscence after implant placement. Five months after placing the implant, the second stage of implant surgery was performed, and healing abutment was connected after removal of the 3D-titanium membrane. Five months after the second stage of implant surgery was done, the final prosthesis was then delivered. Case 2. A 35-year-old female patient presented with discomfort due to pain and mobility of implant #21. Removal of implant #21 fixture was planned simultaneously with placement of the new implant fixture. At the first stage of implant surgery, GBR for horizontal augmentation was performed with DBBM ($Bio-Oss^{(R)}$), irradiated allogenic cancellous bone and marrow (ICB $cancellous^{(R)}$), 3D-titanium membrane ($i-Gen^{(R)}$), resorbable collagen membrane (Ossix $plus^{(R)}$, Datum, Telrad, Israel), and A-PRF because there was approximately 7 mm labial dehiscence after implant placement. At the second stage of implant surgery six months after implant placement, healing abutment was connected after removing the 3D-titanium membrane. Nine months after the second stage of implant surgery was done, the final prosthesis was then delivered. In these two clinical cases, wound healing of the operation sites was uneventful. All implants were clinically stable without inflammation or additional bone loss, and there was no discomfort to the patient. With the non-resorbable titanium membrane, the ability of bone formation in the space was stably maintained in three dimensions, and A-PRF might influence soft tissue healing. This limited study suggests that aesthetic results can be achieved with GBR using 3D-titanium membrane and A-PRF in the anterior maxilla. However, long-term follow-up evaluation should be performed.

The Content Analysis of the Textbooks of Dental Clinical Course (치과임상교과목 교재에 대한 내용분석)

  • Lee, Sun-Mi;Yoo, Jung-Sook;Ahn, Se-Youn;Lim, Mi-Hee;Han, Ji-Youn;Jun, Mi-Kyoung;Lee, Hyun-Ok;Won, Young-Soon
    • Journal of dental hygiene science
    • /
    • v.15 no.3
    • /
    • pp.272-279
    • /
    • 2015
  • This study was conducted to provide baseline data which could suggest a direction of role based efficient integrated clinical education by avoiding duplicate of contents through analyzing clinical courses. Among the 7 clinical courses, orthodontics and periodontology were the most published subjects which were published in 5 kinds of books and dental materials was the least published subject which was published in 2 kinds of books on investigation of overlapping contents based on titles that appeared on chapters and verses of all textbooks for clinical courses. Dental implant was covered in 4 subjects such as oral maxillofacial surgery, prosthodontics, periodontology and dental materials which was the most number. Other overlapping contents were restoration treatment, occlusion and malocclusion, temporomandibular joint diseases, anesthesia sedation, tooth trauma, systemic disease and dental treatment, dental casting, isolation techniques, tooth bleaching, pulp protection, gingivitis periodontitis, tooth development, etc. Reviews of textbooks of clinical courses should be conducted in a detailed manner by systematic, various studies in order to improve quality of the textbooks.