• Title/Summary/Keyword: materials science

Search Result 32,549, Processing Time 0.067 seconds

Comparison of Boiling Point and Distillaiion Ranige, Melting Range, and Identification Methods of Various Organizations on Synthetic Food Additives (식품첨가물에 대한 여러 기관의 비점 및 유분측정법, 융점측정법 및 확인시험법 비교)

  • Shin Dong-Hwa;Kim Yong-Suk;Lee Young-Hwan;Bang Jeong-Ho;Om Ae-Son;Shin Jae-Wook;Lee Tal-Soo;Jang Young-Mi;Hong Ki-Hyoung;Park Sung-Kwan;Kwon Yong-Kwan;Park Jae-Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.3
    • /
    • pp.134-140
    • /
    • 2005
  • Boiling point and distillation range, melting range, and identification methods in general test method of Korea, Japan, Joint FAO/WHO Expert Committee of Food Additives (JECFA), and USA on chemical food additives were compared. Boiling point of propylene glycol was indicated as boiling point in Korea, distillate in Japan, distillation range in JECFA and USA, and its value was up to the standard. Distillation range of propionic acid was indicated as distillate in Korea and Japan, distillation range in JECFA and USA, and its value was up to the standard. There is no standard on distillation range of isopropyl alcohol in Japanese method. Test method of melting range on synthetic food additives was identical in all organizations, and there are 28 items to which this test method applies in Korean Food Additives Code. The standards on molting range of D-mannitol were different in various organizations, and in USA method there are no standards to which L-ascorbic acid, calciferol, and fumaric acid apply. Synthetic food additives performing the identification test were 251 items in Korean Food Additives Code, but there are no items to which manganese, glycerophosphate, bromate, thiosulfate, and bromide apply. Calcium benzoate was dissolved by heating in benzoate test and we could not identify the citrate in ferric citrate by method (2) of Korea and Japan. Identification test methods for ammonium, lactate, magnesium, copper, sulfate, phosphate, and zinc were identical in all organizations, and these could be identifed by current identification methods.

Survival and Cross-contamination of Escherichia coli O157:H7 on Various Agricultural Product-Contact Surfaces (농산물 접촉 표면 재질에 따른 Escherichia coli O157:H7의 생존 및 상추로의 교차오염도 조사)

  • Kim, Se-Ri;Choi, Song-Yi;Seo, Min-Kyoung;Kim, Won-Il;Chung, Duck-Hwa;Ryu, Kyoung Yul;Yun, Jong-Chul;Kim, Byung-Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.272-278
    • /
    • 2013
  • To evaluate the effect of surface contaminated with Escherichia coli O157:H7 (E. coli O157:H7) on the microbiological safety of lettuce, this study was conducted to investigate the attachment, biofilm producing, survival, and cross-contamination of E. coli O157:H7 on stainless steel and polyvinyl chloride (PVC). The attachment rate of E. coli O157:H7 on PVC was 10 times higher than that on stainless steel after exposure 1 h in cell suspension. However, there was not a difference between two types of surface after exposure for 6 h and 24h. The biofilm producing of E. coli O157:H7 was TSB > 10% lettuce extracts > 1% lettuce extracts > phosphate buffer. When two kinds of materials were stored at various conditions ($20^{\circ}C$ and $30^{\circ}C$, relative humidity (RH) 43%, 69%, and 100%), the numbers of E. coli O157:H7 at $30^{\circ}C$, RH 43% or RH 69% were reduced by 5.0 log CFU/coupon within 12 h regardless of material type. Conversely, the survival of E. coli O157:H7 at RH 100% was lasted more than 5 days. In addition, the reduction rate of E. coli O157:H7 was decreased in the presence of organic matter. The transfer efficiency of E. coli O157:H7 from the contaminated surface to lettuce was dependent upon the water amount of the surface of lettuce. Especially, the transfer rate of E. coli O157:H7 was increased by 10 times in the presence of water on the lettuce surface. From this study, the retention of E. coli O157:H7 on produce contact surfaces increase the risk cross-contamination of this pathogen to produce. Thus, it is important that the surface in post harvest facility is properly washed and sanitized after working for prevention of cross-contamination from surface.

Affective Effect of Video Playback Style and its Assessment Tool Development (영상의 재생 스타일에 따른 감성적 효과와 감성 평가 도구의 개발)

  • Jeong, Kyeong Ah;Suk, Hyeon-Jeong
    • Science of Emotion and Sensibility
    • /
    • v.19 no.3
    • /
    • pp.103-120
    • /
    • 2016
  • This study investigated how video playback styles affect viewers' emotional responses to a video and then suggested emotion assessment tool for playback-edited videos. The study involved two in-lab experiments. In the first experiment, observers were asked to express their feelings while watching videos in both original playback and articulated playback simultaneously. By controlling the speed, direction, and continuity, total of twelve playback styles were created. Each of the twelve playback styles were applied to five kinds of original videos that contains happy, anger, sad, relaxed, and neutral emotion. Thirty college students participated and more than 3,800 words were collected. The collected words were comprised of 899 kinds of emotion terms, and these emotion terms were classified into 52 emotion categories. The second experiment was conducted to develop proper emotion assessment tool for playback-edited video. Total of 38 emotion terms, which were extracted from 899 emotion terms, were employed from the first experiment and used as a scales (given in Korean and scored on a 5-point Likert scale) to assess the affective quality of pre-made video materials. The total of eleven pre-made commercial videos which applied different playback styles were collected. The videos were transformed to initial (un-edited) condition, and participants were evaluated pre-made videos by comparing initial condition videos simultaneously. Thirty college students evaluated playback-edited video in the second study. Based on the judgements, four factors were extracted through the factor analysis, and they were labelled "Happy", "Sad", "Reflective" and "Weird (funny and at the same time weird)." Differently from conventional emotion framework, the positivity and negativity of the valence dimension were independently treated, while the arousal aspect was marginally recognized. With four factors from the second experiment, finally emotion assessment tool for playback-edited video was proposed. The practical value and application of emotion assessment tool were also discussed.

Study for Automatic Exposure Control Technique (AEC) in SPECT/CT for Reducing Exposure Dose and Influencing Image Quality (SPECT/CT에서 자동노출제어(AEC)를 이용함으로써 얻어지는 영상의 질 평가와 피폭선량 감소에 관한 고찰)

  • Yoon, Seok-Hwan;Lee, Sung-Hwan;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.33-38
    • /
    • 2014
  • Purpose Auto exposure control (AEC) in SPECT/CT automatically controls the exposure dose (mA) according to patient's shape and size. The aim of this study was to evaluate the effect of AEC in SPECT/CT on exposure dose reduction and image quality. Materials and Methods The model of SPECT/CT used in this study was Discovery 670 (GE, USA), Smart mA for AEC; and $^{99m}Tc$ as a radioisotope. To compare SPECT and CT images by CT exposure dose variation, we used a standard technique set at 80, 100, 120, 140 kVp, 10, 30, 50, 100, 150, 200, 250 mA, and AEC at 80, 100, 120, 140 kVp, 10-250 mA. To evaluate resolution and contrast of SPECT images, triple line phantom and flangeless Esser PET phantom were used. For CT images, noise and uniformity were checked by anthropomrphic chest phantom. For dose evaluation to find DLP value, anthropomorphic chest phantom was used and the CT protocol of torso was applied by standard technique (120 kVp, 100 mA) and AEC (120 kVp, 10-250 mA). Results When standard and AEC were applied, the resolutions at SPECT images with attenuation correction (AC) were the same as FWHM by center 3.65 mm, left 3.48 mm, right 3.61 mm. Contrasts of standard and AEC showed no significant difference: standard 53.5, 29.8, 22.5, 15.8, 6.0, AEC 53.5, 29.6, 22.4, 15.7, 6.1 In CT images, noise values at standard and AEC were 15.4 and 18.5 respectively. The application of AEC increases noise but the value of coefficient variation were 33.8, 24.9 respectively, obtaining uniform noise image. The values of DLP at standard and AEC were 426.78 and 352.09 each, which shows that the application of AEC decreases exposure dose more than standard by approximately 18%. Conclusion The results of our study show that there was no difference of AC in SPECT images based on the CT exposure dose variation at SPECT/CT images. It was found that the increased CT exposure dose leads to the improvement of CT image quality but also increases the exposure dose. Thus, the use of AEC in SPECT/CT contributes to obtaining equal AC SPECT images, and uniform noise in CT images while reducing exposure dose.

  • PDF

A Study on the Organization and Function of Security for the Royal Household in the Early Koryo: focused on 2Gun6Wi (고려전기(高麗前期)의 왕실호위 제도의 조직과 기능에 관한 연구: 2군육위(二軍六衛)를 중심으로)

  • Kim, Hyeong-Jung
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.139-176
    • /
    • 2013
  • It is believed that the Koryo dynasty era is the period which has very special meaning with regard to the history of the VIP guard system. The guard system in the early Koryo dynasty time focused on the official protection for kings and their families with absolute royal authority. On the contrary, the guard system in the late Koryo dynasty time, especially military regime period, conducted providing private protection for military rulers and increasing their power. The official guard troops named 2Gun6Wii became just perfunctory organizations at that time. That is the reason why this study develops the discussion only about the guard system of the early Koryo time. The official VIP guard organizations under the government structure of the early Koryo period were Naegoonbu, Byeongbu and Joongchoowon. This study particularly reviewed the Joongchoowon with thorough research. In the meantime, the guard organizations under the military chart of the early Koryo period were 2Gun6Wii, Gonghakgoon, Geonryonggun and so on. 2Gun consisted of ungyanggun and yonghogun. They were the royal bodyguards. This study especially tried to review the substance of the Gonghakgoon, Geonryonggun with different point of view from other theories. The Gumowwii, one of 6 Wii, conducted many official duties such as royal palace protection, capital city Gaesung defence, area patrols, criminal apprehension and disturbance prevention. It also accomplished crowd control and convoy mission at the streets to respond emergency cases while carrying out VIP protection roles for kings and Chinese diplomats. Many bibliographies verified that the Chunwoowii was the royal bodyguards which helped kings during state ceremonies and grand meetings held by kings. Consequentially, it is true that this study discovered, analyzed and evaluated various references and research materials related with the guard system. It is meaningful that this study newly reviewed the organizations and functions of the guard system as one structure.

  • PDF

Effectiveness of Fentanyl Transdermal Patch (Fentanyl-TTS, $Durogegic^{(R)}$) for Radiotherapy Induced Pain and Cancer Pain: Multi-center Trial (방사선치료로 인한 통증 및 암성통증에 대한 듀로제식의 효과: 다기관연구)

  • Shin, Seong-Soo;Choi, Eun-Kyung;Kim, Jong-Hoon;Ahn, Seung-Do;Lee, Sang-Wook;Kim, Yeun-Sil;Lee, Kyu-Chan;Lee, Chang-Geol;Loh, John-JK;Chun, Mi-Son;Oh, Young-Teak;Kim, Ok-Bae;Huh, Seung-Jae
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.263-271
    • /
    • 2006
  • $\underline{Purpose}$: To evaluate the effectiveness and safety of fentanyl-TTS in the management of radiotherapy induced acute pain and cancer pain treated with radiotherapy. $\underline{Materials\;and\;Methods}$: Our study was open labelled prospective phase IV multi-center study. the study population included patients with more 4 numeric rating scale(NRS) score pain although managed with other analgesics or more than 6 NRS score pain without analgesics. Patients divided into two groups; patients with radiotherapy induced pain (Group A) and patients with cancer pain treated with radiotherapy (Group B). All patients received 25 ug/hr of fentanyl transdermal patch. Primary end point was pain relief; second end points were change in patient quality of life, a degree of satisfaction for patients and clinician, side effects. $\underline{Results}$: Between March 2005 and June 2005, 312 patients from 26 participating institutes were registered, but 249 patients completed this study. Total number of patients in each group was 185 in Group A, 64 in Group B. Mean age was 60 years and male to female ratio was 76:24. Severe pain NRS score at 2 weeks after the application of fentanyl was decreased from 7.03 to 4.01, p=0.003. There was a significant improvement in insomnia, social functioning, and quality of life. A degree of satisfaction for patients and clinician was very high. The most common reasons of patients' satisfactions was good pain control. Ninety six patients reported side effect. Nausea was the most common side effect. There was no serious side effect. $\underline{Conclusion}$: Fentanyl-TTS was effective in both relieving pain with good tolerability and improving the quality of life for patients with radiotherapy induced acute pain and cancer pain treated with radiotherapy. The satisfaction of the patients and doctors was good. There was no major side effect.

Citation Trend and Suggestions for Improvement of Impact Factor of Journal of Korean Therapeutic Radiology and Oncology (대한방사선종양학회지의 학술인용 변화 추이 및 학술 영향력 지수 개선을 위한 제안: 한국의학학술지 인용색인 자료 분석)

  • Kim, Seong-Hwan;Ahn, Myeong-Im;Jeong, So-Na;Hwang, Seong-Su
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.309-316
    • /
    • 2006
  • $\underline{Purpose}$: To analyze the recent citation trend and to find a way to improve impact factor (IF) of the Journal of Korean Therapeutic Radiology and Oncology (JKSTRO) by analysis of Korean Medical Citation Index (KoMCI) citation data of JKSTRO and comparison with that of mean citation data of all journals enlisted on KoMCI (KoMCI journals) during 2000-2005. $\underline{Materials\;and\;Methods}$: All citation data of entire journals enlisted on KoMCI and JKSTRO from 2000 to 2005 were obtained from KoMCI. The trend of total and annual number of published articles and reference citations, total citations and self-citations per paper, IF and impact factor excluding self-citations (ZIF) were described and compared on both KoMCI journals and JKSTRO. $\underline{Results}$: Annual number of published articles was decreased for 6 years on both KoMCI journals and JKSTRO (32% and 38% reduction rate). The number of Korean journal references per article is 1.6 papers on JKSTRO comparing to 2.0 papers on KoMCI journals. The percentage of Korean references/total references increased from 5.0% in 2000 to 7.7% in 2005 on JKSTRO and from 8.5% in 2000 to 10.1% on KoMCI journals. The number of total citations received/paper on JKSTRO (average 1.333) is smaller than that of KoMCI journals (average 1.694), there was an increased rate of 67% in 2005 comparing to 2000. The percentage of self-citations/total citations (average 72%) on JKSTRO is slightly higher than that of KoMCI journals (average 61%). IF of JKSTRO was gradually improved and 0.144, 0.125, 0.088, 0.107, 0.187, and 0.203 in 2000-2005 respectively. However, ZIF of JKSTRO is steadily decreased from 0.038 in 2000 to 0.013 in 2005 except 0.044 in 2004. $\underline{Conclusion}$: IF of JKSTRO was slightly improved but had some innate problem of smaller number of citations received. To make JKSTRO as a highly cited journal, the awareness of academic status of JKSTRO and active participation of every member of JKSTRO including encouraging self-citations of papers published recent 2 years and submission of English written papers, and active academic cooperation with related academic societies.

Experimental renal artery embolization with iohexol-ethanol and barium-ethanol in dogs (개에서 iohexol-ethanol 및 barium-ethanol을 이용한 실험적 신동맥 색전술)

  • Hwang, Guk-jin;Chang, Dongwoo;Seo, Minho;Jung, Joohyun;Choi, Mincheol;Yoon, Junghee
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.429-436
    • /
    • 2001
  • The present study was performed to investigate the effect of iohexol-ethanol mixture and barium-ethanol mixture on the induction of transcatheter renal artery embolization in healthy 18 dogs, which were divided into two groups of 9 dogs and the 9 dogs were divided into 3 subgroups of 3 dogs. The renal artery embolization was undertaken unilaterally with the dose of 1.5, 2.0, and 3.0 ml/kg iohexol-ehtanol mixture and with the dose of 0.2, 0.4, and 0.8 ml/kg barium-ethanol mixture. And serum chemistry on 0, 1,3, 7, and 14 days, intravenous pyelography on 7days, angiography on 14 days, and histopathology on 14 days were evaluated. Serum BUN and creatinine concentration of two groups with iohexol-ethanol mixture and barium-ethanol mixture administration were mildly increased a t 1 day after injection of embolic materials and then returned to baseline. No significant changes in BUN and creatinine levels occurred in any of dogs. In all dogs with the dose of 1.5 ml/kg iohexol-ethanol mixture, the renal arteries were not embolized. All dogs with the dose of 3.0 ml/kg died. In all dogs with the dose of 2.10 ml/kg, the treated arteries were completely occluded. In barium-ethanol mixture administered group, the renal artery in one dog with the dose of 0.2 ml/kg was not embolized. In all dogs with the dose of 0.8 ml/kg, the renal arteries were completely embolized, but loac overembolization occured in two dogs. All animals with the dose of 0.4 ml/kg had effective embolization and no evidence of radiopaque barium opacity in systemic arteries distal to the renal-artery was found. All embolized kidneys were shrunk and decreased in size in gross examination and were shown diffuse necrosis in histopathologic examination. In the present study, renal arteries were embolized with the dose of 2.0 ml/kg iohexol-ethanol mixture or 0.4 ml/kg barium-ethanol mixture. And it is considered that the dose had a satisfactory embolic effect.

  • PDF

Screening of Chemicals on Bacterial Brown Blotch Caused by Pseudomonas tolaasii on Flammulina velutipes (팽이버섯 세균성갈색무늬병(Pseudomonas tolaasii) 방제약제 선발)

  • Lee, Hyun-Uk;Kim, Tae-Sung;Park, Hyean-Cheal;Song, Keun-Woo;Shin, Won-Kyo;Moon, Byung-Ju
    • The Korean Journal of Mycology
    • /
    • v.27 no.2 s.89
    • /
    • pp.164-169
    • /
    • 1999
  • This study was carried out in an attempt to select chemicals such as zeolite granules, chitosan, wood-vinegar, $Ca(OCl)_2$, NaOCl, against bacterial brown blotch caused by Pseudomonas tolaasii on Flammulina velutipes in laboratory and mushroom unit. Results obtained using these chemicals were summarized. Inhibitory effect on $Ca(OCl)_2$ and wood-vinegar with 0.5% concentration was shown to caual pathogen, P. tolaasii, by slight damage on the mycelial growth of F. velutipes. Those materials were recognized as promising one for control of bacterial brown bloth on F. velutipes. Disease incidence in control was the highest value as 43.8%; whereas chemical treatment was estimated as 14.6% with 0.5% of $Ca(OCl)_2$. Disease incidence was inhibited about 20% in chemical treatment with 0.5% of wood-vinegar, 1.0% of $Ca(OCl)_2$, and 26.1% with 1.0% of wood-vinegar. For the inhibition effects of chemical concentrations, it was effective at the low concentration which was 0.5% rather than that of 1.0%. Quality of mushrooms was significantly improved, and yields was also increased by 30% in the chemical treatment. In case of $Ca(OCl)_2$ treatment at 1.0% concentration, the yields was increased by 35.6% showed the highest value among tested chemicals. However, the overall effects including disease incidence, quality and yields suggests that $Ca(OCl)_2$ is relatively more effective than wood-vinegar, and the optimal concentration controlling the disease was $0.5{\sim}1.0%$ with $Ca(OCl)_2$ and 0.5% with wood-vinegar.

  • PDF

Studies on Antimicrobial Susceptibility and Characteristics of R-plasmids and Antigens of High-level Gentamicin Resistant Enterococcus faecalis (Gentamicin 고도내성 Enterococcus faecalis균주의 항균제감수성, R-플라스미드 및 항원의 특성연구)

  • Kang, Hyun
    • Biomedical Science Letters
    • /
    • v.1 no.1
    • /
    • pp.55-72
    • /
    • 1995
  • Forty gentamicin-resistant isolates of Enterococcus faecalis were selected from various clinical materials, determined their antimicrobial susceptibility, and studied there R-plasmid characteristics and polypeptide patterns. All of the isolates were susceptible to vancomycin. The MICs($\mu$/ml) of antimicrobial agents to the isolates were as follows; the MIC of gentamicin was 128 and $\geq$2040, ampicillin 1 and 1, chlorarmphenicol 2 and 8, erythromycin 32 and 256, and vancomycin 1 and 2. E. faecalis HL-1 strain had 8 plasmid DNA elements, HL-2 and HL-3 strains had 6, HL-4 had 7, HL-5 had 4, and HL-6 had 5. The 51.7 Kb of gentamicin resistance plasmid DNA was conjugally transferred from two strains of E. faecalis HL-1 and HL-6 to S. aureus SK 982. The plasmid transfer frequency between S. aureus SK 982 and E. faecalis HL-1 or E. faecalis HL-6 was 6.3$\times10^{-4} and 3.7$\times10^{-5}$, respectively. Plasmid curing ratio after the treatment of ethidium bromide(10$\mu$/ml) to E. faecalis tarnsconjugants R-1 and R-6 were about 51% and 67%, respectively. The tetracycline gene was located in 2.15 Kb plasmid of E. faecalis HL-1, but it was not found in the E. faecalis HL-6 by Southern blot analyses. The antigenic components of E. faecalis HL-1, HL-6, R-1 and R-6 strains were analyzed by SDS-PAGE and immunoblotting. The E. faecalis strains had 7 to 16 polypeptide bands, however their major proteins were 97.8 and 26.8 Kd. At the Immunoblotting, 97.8, 95.8, 74.8, 63.5, 33.7 and 26.8 Kd polypeptides of the strains showed major antigenic activities with patient's sera infected intra-abdominally with an E. faecalis strain.

  • PDF