• Title/Summary/Keyword: material standardization

Search Result 233, Processing Time 0.023 seconds

Evaluation on Extraction Conditions and HPLC Analysis Method for Bioactive Compounds of Astragali Radix (황기의 추출조건 및 유효성분의 HPLC 분석법 평가)

  • Kim, Geum Soog;Lee, Dae Young;Lee, Seung Eun;Noh, Hyung Jun;Choi, Je Hun;Park, Chun Geun;Choi, Soo Im;Hong, Seung Jae;Kim, Seung Yu
    • Korean Journal of Medicinal Crop Science
    • /
    • v.21 no.6
    • /
    • pp.486-492
    • /
    • 2013
  • This study has been conducted to establish the optimal extraction process and HPLC analysis method for the determination of marker compounds as a part of the materials standardization for the development of health functional food materials from Astragali radix. Five extraction conditions including the shaking extraction at room temperature and the reflux extraction at $85^{\circ}C$ with 30%, 50% and 95% ethanol were evaluated. Reflux extraction with 50% ethanol showed the highest extraction yield as $27.27{\pm}2.27%$, while the extraction under reflux with 95% ethanol showed significantly the lowest yield of $10.55{\pm}0.24%$. The quantitative determination methods of calycosin-7-O-${\beta}$-D-glucoside and calycosin as marker compounds of Astragali radix extracts were optimized by HPLC analysis using a Thermo Hypersil column ($4.6{\times}250mm$, $5{\mu}m$) with the gradient elution of water and acetonitrile as the mobile phase at the flow rate of $0.8mLmin^{-1}$ and a detection wavelength of 230nm. The HPLC/UV method was applied successfully to the quantification of two marker compounds in Astragali radix extracts after validation of the method with the linearity, accuracy and precision. The contents of calycosin-7-O-${\beta}$-D-glucoside and calycosin in 50% ethanol extracts by reflux extraction were significantly higher as $1,700.3{\pm}30.4$ and $443.6{\pm}8.4{\mu}g-1$, respectively, comparing with those in other extracts. The results indicate that the reflux extraction with 50% ethanol at $85^{\circ}C$ is optimal for the extraction of Astragali radix, and the established HPLC method are very useful for the evaluation of marker compounds in Astragali radix extracts to develop the health functional material from Astragali radix.

Validation of Analytical Method of Marker Compounds in Extract of Pear Pomace as a Functional Health Ingredient (건강기능식품 원료로서 나주 배박 추출물의 지표성분 분석법 벨리데이션)

  • Cho, Eun-Jung;Bang, Mi-Ae;Cho, Seung-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.11
    • /
    • pp.1682-1686
    • /
    • 2015
  • This study was conducted to establish an HPLC analysis method for determination of marker compounds as part of materials standardization for development of health functional food materials from pear pomace. The quantitative determination method of caffeic acid and chlorogenic acid as marker compounds of pear pomace extract (PPE) was optimized by HPLC analysis using a C18 column ($5{\times}250mm$, $5{\mu}m$) with a 0.2% elution gradient of acetic acid and methanol as the mobile phase at a flow rate of 0.8 mL/min and detection wavelength of 330 nm. The HPLC/UV method was applied successfully to the quantification of marker compounds in PPE after validation of the method with linearity, accuracy, and precision. The method showed high linearity of the calibration curve with a coefficient of correlation ($R^2$) of 0.9999, and limit of detection and limit of quantification were $1.14{\mu}g/mL$ (caffeic acid) and $1.61{\mu}g/mL$ (chlorogenic acid) as well as $4.9{\mu}g/mL$ (caffeic acid) and $4.9{\mu}g/mL$ (chlorogenic acid), respectively. Relative standard deviation values from intra- and inter-day precision were less than 3.1% (caffeic acid) and 4.0% (chlorogenic acid), respectively. Recovery rates of caffeic acid and chlorogenic acid at 12.5, 25, and $50{\mu}g/mL$ were 93.66~106.32% and 97.33~105.68%, respectively. An optimized method for extraction of caffeic acid and chlorogenic acid in PPE was established through diverse extraction conditions, and the validation indicated that the method is very useful for evaluation of marker compounds in PPE to develop a health functional food material.

Evaluation of the Radiopacity of Contemporary Luting Cements by Digital Radiography (디지털방사선촬영술을 이용한 합착용 시멘트의 방사선불투과성 평가)

  • An, Seo-Young;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.377-383
    • /
    • 2013
  • This study examined the radiopacity of eight contemporary luting cements by direct digital radiography. Five disc-shaped specimens ($5mm{\times}1mm$) were prepared for each material tested (BisCem, Clearfil SA Luting, Duolink, Maxcem Elite, Multilink Speed, Panavia F 2.0, RelyX Unicem Clicker, V-link). The specimens were radiographed using a Kodak CS 7600 image plate (Carestream Health, Inc., Rochester, NY, USA) and an aluminum step wedge with a range of thicknesses (1.5 to 16.5 mm in 1.5 mm increments) and a 1 mm tooth used as a reference. A dental X-ray machine Kodak 2200 Intraoral X-ray System (Carestream Health, Inc., Rochester, NY, USA), operating at 70 kVp, 4 mA, 0.156 s and a source-to-sample distance of 30 cm, was used. According to international standards, the radiopacity of the specimens was compared with that of an aluminum step wedge using NIH ImageJ software (available at http://rsb.info.nih.gov/ij/).The data was analyzed by ANOVA and a Tukey's post hoc test. Maxcem Elite (5.66) showed the highest radiopacity of all materials, followed in order by Multilink Speed (3.87) and V-link (2.83). The radiopacity of Clearfil SA Luting (1.35), BisCem (1.33), Panavia F 2.0 (1.29) and Duolink (1.10) were between enamel (1.79) and dentin (0.19). RelyX Unicem Clicker (0.71) showed the lowest radiopacity, which was higher than that of dentin. All materials showed a radiopacity above the minimum recommended by the International Organization for Standardization and the American National Standards/American Dental Association with the exception of RelyX Unicem Clicker.

The Study on Method of Speech Audiometry and the Korean Word Lists Part 1 : Normal Hearing Group (어음청력점사방법과 한국어음청력검사표에 관한 연구)

  • 김기령;김영명;최생이;강대령;심윤주
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.6.1-6
    • /
    • 1977
  • Among the various audiometric test batteries, pure tone and speech audiometry was carried as routine. During the past 20 years, there have been works on speech word list for Korean language. As a preliminary work for standardization of Korean speech word list, the authors are intended to study on the factors of test methods with these proposal speech word lists. Now, authors has studied as followings methods and materials and the results were obtained as followings. A. Materials and Methods a. Word List 1. Paik Chun Kee (Paik) 2. Soh Jin Myoung (Soh) 3. Cynn Kyu Shik (Cynn) 4. Lee Jong Dam (Lee) 5. Hahm Tae Young (Hahm) b. Test Method 1. ascending 2. descending c. Test Material 1. live voice 2. Recorded male voice 3. Recorded female voice B. Results 1. Score of ascending method was better result than descending method. 2. Speech reception threshold and discrimination score were better in recorded female voice, live voice and recorded male voice in that order. 3. Speech reception thresholds among tested word lists were Hahm, Lee, Soh, Cynn and Paik in that order. 4. Discrimination score was highest with Cynn and Lee, Soh, Hahm, Paik in that order.

  • PDF

Establishment of the Preparation Method on Quality Changes of Seasoned Perilla Leaves during Storage (깻잎절임의 조리조건 확립 및 품질변화)

  • Lyu, Eun-Soon;Lee, Ki-Eun;Choi, Dong-Man;Shin, Dong-Ju;Chung, Sun-Kyung
    • Food Science and Preservation
    • /
    • v.14 no.6
    • /
    • pp.598-604
    • /
    • 2007
  • Process development and standardization are necessary in maintaining high hygienicquality of side dishes. Seasoned perilla leaves are a typical side dish needing process development. In this study the optimum condition for preparing seasoned perilla leaves was investigated experimentally. The best sensory quality was established by response surface methodology. The rinsing and washing method of preparing fresh perilla leaves was optimized to decontaminate the raw material and preserve the product in chilled storage. Washing and rising with 3% salt water reduced the aerobic bacterial count of perilla leaves to 0.55 (log CFU/g), while rinsing reduced the load from 8.08 to 4.27 (log CFU/g). The effect of rinsing method was maintained during subsequent storage of the prepared seasoned leaves at $10^{\circ}C$. There was no significant quality change in the product during chilled storage at $10^{\circ}C$. Soaking in 3% salt water for 1 min, followed by rinsing with tap water, contributed positively to the microbial quality, and is proposed as the optimal preparation method.

An Experimental Study for RFID Application of Construction Materials in an Apartment House Construction Site (건설자재의 공동주택 현장 적용을 위한 RFID 부착 및 인식에 관한 실험적 연구)

  • Ju, Ki-Beom;Han, Choong-Han
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.5
    • /
    • pp.67-75
    • /
    • 2009
  • While the trend of all industries recently lies in combination, construction industry is much interested in enhancing efficiency and competitiveness in the aspect of site control by adopting RFID. Though RFID has been applied to diverse areas thus far, it cannot be easily applied to construction industry due to diverse physical, chemical and use-environmental properties of construction materials. Furthermore, it is rarely applied to the site because of many problems in its application. It is required to prepare RFID code issuance and system that can systematically control the code as well as to research the standardization of frequency, specification, protocol, package method, recognition method, etc in order to apply RFID to construction industry. In this research, RFID code issuance and management program are proposed as a part of program research to apply RFID. Furthermore, the restricted matters of existing RFID tag are drawn to produce pilot product of RFID tag that can solve it so as to perform site application test. According to the experiment, effective recognition distance varies depending on material/environmental property and control efficiency changes depending on attachment method and application method. Thus, preparing diverse restrictive factors and solutions by systematically analyzing control method(medium, process) of current architecture materials and applying it to construction site can be the way to successfully apply RFID.

Biochemical Methane Potential of Agricultural Waste Biomass (농산 바이오매스의 메탄 생산 퍼텐셜)

  • Shin, Kook-Sik;Kim, Chang-Hyun;Lee, Sang-Eun;Yoon, Young-Man
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.903-915
    • /
    • 2011
  • Recently, anaerobic methane production of agricultural waste biomass has received increasing attention. Until now domestic BMP (Biochemical methane potential) studies concerned with agricultural waste biomass have concentrated on the several waste biomass such as livestock manure, food waste, and sewage sludge from WWTP (Waste water treatment plant). Especially, the lack of standardization study of BMP assay method has caused the confused comprehension and interpretation in the comparison of BMP results from various researchers. Germany and USA had established the standard methods, VDI 4630 and ASTM E2170-01, for the analysis of BMP and anaerobic organic degradation, respectively. In this review, BMP was defined in the aspect of organic material represented as COD (Chemical oxygen demand) and VS (Volatile solid), and the influence of several parameters on the methane potential of the feedstock was presented. In the investigation of domestic BMP case studies, BMP results of 18 biomass species generating from agriculture and agro-industry were presented. And BMP results of crop species reported from foreign case studies were presented according to the classification system of crops such as food crop, vegetables, oil seed and specialty crop, orchards, and fodder and energy crop. This review emphasizes the urgent need for characterizing the innumerable kind of biomass by their capability on methane production.

Evaluation of Titanium-nitride Coated Crown: Surface Hardness, Corrosion Resistance and Color Sustainability (타이타늄-질소 코팅된 금속관에 대한 평가: 표면 경도, 부식 저항성, 색조 안정성)

  • Kim, Hyojin;Lim, Sumin;Kim, JinYoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.3
    • /
    • pp.344-351
    • /
    • 2021
  • The purpose of this study was to compare surface hardness between titanium-nitride coated crowns (TiNCs) and stainless steel crowns (SSCs), and to evaluate the corrosion resistance and color sustainability of TiNCs. Ten TiNCs and 10 SSCs were used for the hardness test. Measurement was performed 30 times for each type of crowns, and the mean values were compared. Metallic raw material plates (before being processed into crowns) of TiNCs and SSCs were prepared for the corrosion resistance test. The total amounts of metal ion releases in the test solution were detected by inductively coupled plasma-optical emission spectrometry. Five TiNCs were subjected to the color sustainability test by applying repetitive brushing forces. The mean hardness values of TiNC group and SSC group were 395.53 ± 105.90 Hv and 278.70 ± 31.45 Hv respectively. Hardness of TiNCs were significantly higher than that of SSCs. The total amounts of metal ion releases from the materials of TiNCs and SSCs satisfied the criterion in International Organization for Standardization 22674. The results mean that TiNCs and SSCs were not harmful in an acidic environment. The golden coating was stable against the repetitive physical stimulations for a given period time.

A Study on the Safety Management Methods of Micro-Gas Engine Combined Heat and Power System (소형 가스엔진 열병합발전 시스템의 안전관리 방안에 관한 연구)

  • Kim, So-Hyun;Kim, Min-Woo;Lee, Eun-Kyung;Lee, Jung-Woon
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.76-89
    • /
    • 2018
  • The distribution of the combined heat and power system is active as a solution to the instability of energy supply and environmental pollution caused by continuous industrial development. In Korea, the safety standards for combined heat and power system using a gas engine are insufficient therefore the study on this is needed. In this study, the safety performance and structural/material assessment items of domestic and international standards applied to the combined heat and power system were analyzed to carry out a standardization study on safety performance applicable to 20 kW gas engine combined heat and power system. In addition, the safety performance assessment (plan) of the gas engine combined heat and power system was derived by performing risk analysis and risk assessment using HAZOP. Assessment items include engine ignition systems related to safety performance, piping tight performance, watering and temperature rise performance, combustion performance, electrical efficiency, thermal efficiency, overall efficiency and humidity performance. Gas and water pipes, gas control and shut-off valves, durability, heat resistance, and cold resistance of metal or non-metallic materials related to the structure and materials of the gas engine combined heat and power systems.

Development and Validation of Analytical Method for Decursin in Aerial Parts of Angelica gigas Nakai Extract (참당귀 지상부 추출물의 지표성분 decursin의 분석법 개발 및 검증)

  • Kim, Hee-Yeon;Lee, Ki-Yeon;Kim, Tae-Hee;Park, A-Reum;Noh, Hee-Sun;Kim, Si-Chang;Ahn, Mun-Seob
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.52-57
    • /
    • 2019
  • Method development and validation of decursin for the standardization of Angelica gigas Nakai as a functional ingredient and health food were accomplished. The quantitative determination method of decursin as a marker compound of aerial parts of Angelica gigas Nakai extract (AAGE) was optimized by HPLC analysis using a C18 column ($3{\times}150mm$, $3{\mu}m$) with 0.1% TFA in water and acetonitrile as the mobile phase at a flow rate of 0.5 mL/min and detection wavelength of 330 nm. The HPLC/PDA method was applied successfully to quantification of the marker compound in AAGE after validation of the method with linearity, accuracy, and precision. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.9994 and the limit of detection and limit of quantitation were $0.011{\mu}g/mL$ and $0.033{\mu}g/mL$, respectively. Relative standard deviation (RSD) values of data from intra- and inter-day precision were less than 1.10% and 1.13%, respectively. Recovery of decursin at 0.5, 1, 5 and $10{\mu}g/mL$ were 92.38 ~ 104.11%. These results suggest that the developed HPLC method is very useful for the determination of marker compound in AAGE to develop a health functional material.