• Title/Summary/Keyword: mass uncertainty

Search Result 252, Processing Time 0.021 seconds

Development of a Model System of Uncertainty Evaluations for Multiple Measurements by Isotope Dilution Mass Spectrometry: Determination of Folic Acid in Infant Formula

  • Kim, Byung-Joo;Hwang, Eui-Jin;So, Hun-Young;Son, Eun-Kyung;Kim, Yong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3139-3144
    • /
    • 2010
  • A model system has been established for the evaluation of the uncertainty of the value from measurements of multiple subsamples by isotope dilution mass spectrometry (IDMS). In this report, we apply this model system for the evaluation of measurement uncertainty in determination of folic acid in infant formula. Five subsamples were analyzed by IDMS. The mean of the measurement results of the five subsamples was assigned as the final measurement value. The standard deviation (s) of the results from five subsamples was attributable to repeatability of the measurement. The uncertainty components in the IDMS measurement methods were categorized into two groups. Group I includes uncertainty components which give common systematic effects to all subsamples and do not contribute to the variation among multiple measurements (repeatability). Group II includes uncertainty components that give random effects on the measurement results, and are related with the measurement repeatability. These random effects are attributed to s. Therefore, the uncertainty of the final value was calculated by combining the standard deviation of the mean of multiple measurements, $s/{\surd}n$ (where n = 5), and the measurement uncertainty associated with the uncertainty components that give systematic effects.

Long Term Stability of Uncertainty Analysis of Light Oil Elow Standard System (장기 안정성을 고려한 경질유 유량표준장치 불확도 평가)

  • Lim, Ki-Won;Choi, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.10 s.241
    • /
    • pp.1130-1138
    • /
    • 2005
  • A national standard system for the petroleum field has been developed to calibrate and test the oil flow meters in Korea. The operating system and the uncertainty of the system were evaluated by the peer reviewers of foreign national metrology institutes in 2002. Since the characteristics of the system might be changed by time, the uncertainty of the system is reevaluated with the consideration of the long term stability of the system. It is found that the system has a relative expanded uncertainty of 0.048 $\%$ in the range of $15\~120\;m^3/h$. According to the uncertainty budget, the uncertainties of the fluid density and the final mass measurement, which are temperature dependent, contribute about $94\%$ of the total uncertainty in the oil flow standard system

Estimation of Rock Mass rating(RMR) and Assessment of its Uncertainty using Conditional Simulations (조건부 모사 기법을 이용한 암반등급의 예측 및 불확실성 평가에 관한 연구)

  • Hong Chang-Woo;Jeon Seok-Won;Koo Chung-Mo
    • Tunnel and Underground Space
    • /
    • v.16 no.2 s.61
    • /
    • pp.135-145
    • /
    • 2006
  • In this study, conditional simulation was conducted to estimate rock mass rating(RMR) in unsurveyed regions. Sequential Gaussian simulation(SGS) and sequential indicator simulation(SIS) were applied for estimating RMR from the bore hole logging data. The uncertainty of SGS and SIS was verified by sample cross validation. A subset composed of 5 bore hole logging data among the original 30 bore hole logging data was set aside as test data. The remainder was training data. The quality of SGS and SIS estimation on the testing data reflects how well it would perform in an unsupervised setting. SGS and SIS were useful stochastic methods to estimate the spatial distribution of rock mass classes correctly and assess the uncertainty of estimation quantitatively. The result of conditional simulation can offer useful information of rock mass classes such as RMR in unsurveyed regions.

A Study on the Controller Design for EMS System using Disturbance Observer (외란관측기를 이용한 자기부상시스템의 제어기 설계에 관한 연구)

  • Kang, Nam-Sook;Jo, Nam-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1264-1269
    • /
    • 2013
  • In this paper, we study a disturbance observer (DOB) based controller for an EMS(Electro-Magnetic Suspension) system in presence of mass uncertainty and input disturbance. The DOB based controller is employed in order to compensate the modeling uncertainty and attenuate disturbance signals. For the design of DOB based controller, the Jacobain linearization of nonlinear system model equation is used. Computer simulation is carried out for nonlinear model in order to compare the performance of the proposed DOB controller with that of the conventional PID controller. The simulation results show that the substantial improvement in the performance can be achieved by the proposed DOB controller.

A Study on Measurement Uncertainty of CMM used for Inspection of Precision Machined parts. (정밀가공 부품 검사에 사용되는 삼차원측정기의 측정불확도 연구)

  • 이갑조;오상록;김종관
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.3-9
    • /
    • 2004
  • The machining parts must be produced within the specification of drawing and those will be able to meet function and efficiency. At that time. it is necessary not only precision machine or machining technique but also the measurement technique is very important. So. the improvement of precise measurement technique is to be joined together at once with improvement of product technique. Finally. he quality and value of the parts are decided by precision measurement. This paper aims to study on he measurement uncertainty when the machined parts are inspected with 3-dimensional coordinate measuring machine. The objectives are to remove an error of measurement and to improve quality and productivity of the mass products.

  • PDF

Quantitative Analysis of Trace pp'-DDE in Corn Oil by Isotope Dilution Mass Spectrometry : Uncertainty Evaluations

  • 김병주;김달호;최종오;소헌영
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.8
    • /
    • pp.910-916
    • /
    • 1999
  • A current interest in chemistry concerns traceability of analytical measurements to the International System of Units (SI) and the proper estimation of their uncertainties in accordance with the internationally agreed guide provided by the International Organization for Standardization (ISO). Isotope dilution mass spectrometry (IDMS) is regarded as a primary method, which make the measurement results traceable to SI units without significant empirical correction factors. Our laboratory, as the national standards institute of Korea, participated in an intercomparison of environmental analysis, pp'-DDE in corn oil, which was organized by the CCQM under supervision of the CIPM to test feasibility of IDMS as a primary method for the trace analysis of organic compounds. In this report, we provide basic equations used for the calculation of the concentration of the analyte in a sample and a precise description of the processes for the evaluation of the uncertainties of the measurement results. Also, we report the experimental conditions adopted to improve the accuracy of the IDMS measurement. The principles contained in ??Guide to the Expression of Uncertainty in Measurement'' provided by ISO are followed for the uncertainty evaluation.

Multiple failure criteria-based fragility curves for structures equipped with SATMDs

  • Bakhshinezhad, Sina;Mohebbi, Mohtasham
    • Earthquakes and Structures
    • /
    • v.17 no.5
    • /
    • pp.463-475
    • /
    • 2019
  • In this paper, a procedure to develop fragility curves of structures equipped with semi-active tuned mass dampers (SATMDs) considering multiple failure criteria has been presented while accounting for the uncertainties of the input excitation, structure and control device parameters. In this procedure, Latin hypercube sampling (LHS) method has been employed to generate 30 random SATMD-structure systems and nonlinear incremental dynamic analysis (IDA) has been conducted under 20 earthquakes to determine the structural responses, where failure probabilities in each intensity level have been evaluated using Monte Carlo simulation (MCS) method. For numerical analysis, an eight-story nonlinear shear building frame with bilinear hysteresis material behavior has been used. Fragility curves for the structure equipped with optimal SATMDs have been developed considering single and multiple failure criteria for different performance levels and compared with that of uncontrolled structure as well as structure controlled using passive tuned mass damper (TMD). Numerical analysis has shown the capability of SATMDs in significant enhancement of the seismic fragility of the nonlinear structure. Also, considering multiple failure criteria has led to increasing the fragility of the structure. Moreover, it is observed that the influence of the uncertainty of input excitation with respect to the other uncertainties is considerable.

Uncertainty Analysis of the Optical Smoke Density Measurement through the Doorway in a Compartment Fire (구획화재의 출입구를 통한 광학적 연기밀도 측정의 불확실성 해석)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.75-79
    • /
    • 2013
  • The present study measured the light transmission to quantify the smoke density(smoke mass concentration) through the doorway in a compartment fire and performed the uncertainty analysis to evaluate the reliability of the measurement technique. The optical light extinction method based on Bourguer's law was applied to estimate the smoke density of doorway exhausting smoke flow in upper layer of a compartment for methane gas fires. The measurement uncertainty of the light extinction measurement was evaluated for the light transmittance, path length, and specific mass extinction coefficient and the expanded uncertainty was estimated about 20% with confidence level of 95%. The mean smoke density through the doorway for the methane fire was calculated for quasi-steady fire and the smoke density linearly increased as the GER increased.

Robust Vibration Control for a Building with Parameter Uncertainty (파라미터 불확실성을 고려한 건물의 견실 진동 제어)

  • 최재원;김신종;이만형
    • Journal of KSNVE
    • /
    • v.10 no.4
    • /
    • pp.575-583
    • /
    • 2000
  • In this paper, we design a vibration control system that includes a 3-D.O.F. mass-spring-damper structure for the analytical model of a building that is excited at the base of this structure by an external dynamic force, and one Active Mass Damper(AMD) on the top of this structure to generate control forces fro attenuation of the structural response. Two robust controllers based on $\mu$-synthesis and H$\infty$ optimal control are designed for the structural system to show that the performance of a control system can be degraded by some parameter uncertainties such as mass, stiffness coefficients, and/or damping coefficients. The performance of the two controllers are compared in terms of nominal performance, robust stability and robust performance by simulations.

  • PDF

Measurement Uncertainty of Nicotine in Environmental Tobacco Smoke (ETS)

  • Lee, Jeong-Il;Lee, Cheol Min;Shim, In-Keun;Kim, Seong-Mi;Lee, Woo-Seok;Kim, Yoon-Shin
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2394-2398
    • /
    • 2013
  • Nicotine is the main component of environmental tobacco smoke, and its presence in indoor air is widely used as a secondhand-smoke indicator. Environmental tobacco smoke is a major source of indoor air pollution, but sufficient investigation of the uncertainty of its measurement, which mirrors the reliability of nicotine measurement, has not been performed. We calculated the uncertainty of measurement of indoor air nicotine concentration at low, medium, and high concentrations of 11.3798, 10.1977, $98.3768{\mu}g/m^3$, respectively, and we employed the Guide to the Expression of Uncertainty in Measurements (GUM), proposed by the International Organization for Standardization (ISO). The factors considered in determining the uncertainty were uncertainty of the calibration curve (calibration curve and repeated measurements), desorption efficiency, extraction volume, and sampling airflow (accuracy and acceptable limits of flowmeter). The measurement uncertainty was highest at low concentrations; the expanded measurement uncertainty is $0.9435{\mu}g/m^3$ and is represented as a relative uncertainty of 63.38%. At medium and high (concentrations, the relative uncertainty was 13.1% and 9.1%, respectively. The uncertainty of the calibration curve was largest for low indoor nicotine concentrations. To increase reliability of measurement in assessing the effect of secondhand smoke, measures such as increasing the sample injection rate ($1{\mu}L$ or more), increasing sampling volume to increase collected nicotine, and using gas chromatography-mass spectrometry (GC/MS) or GC/MS/MS, which has a lower quantitation threshold, rather than gas chromatography with nitrogen phosphorous detector, should be considered.