• Title/Summary/Keyword: mass loss rate

Search Result 404, Processing Time 0.031 seconds

A Combustion Characteristic Analysis of Quercus Variabilis and Pinus Densiflora Fallen Leaves Using Radiation Heat Flux (복사열을 이용한 소나무와 굴참나무 낙엽의 연소특성 분석)

  • Park, Hyung-Ju;Kim, Eung-Sik;Kim, Jang-Hwan;Kim, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.41-46
    • /
    • 2007
  • The combustion characteristics of surface forest fire fuels was analysed using variable external irradiation level. The characteristics such as ignition time, ignition temperature, critical heat flux and mass loss rate were measured. Fuel samples were exposed to incident heat fluxes from 8 to $50\;kW/m^2$. For the measurement of various combustion characteristics, the size of specimen holder was $100\;mm{\times}100\;mm{\times}12\;mm$ and the fuel samples grinded by electric mill were the fallen leaves of Quercus variabilis and Pinus densiflora. As results, the occurrence of ignition is possible to the heat flux more than $9\;kW/m^2$. The fuel of Pinus densiflora keeps its high temperature longer than that of Quercus variabilis during the combustion process. The results of measurement shows that the maximun and average mass loss rate of Quercus variabilis larger than that of Pinus densiflora.

Combustion Characteristics Analysis of a Non-class 1E Cable for Nuclear Power Plants according to Aging Period (경년열화 기간에 따른 원자력발전소용 비안전등급 케이블의 연소특성 분석)

  • Kim, Min Ho;Lee, Seok Hui;Lee, Min Chul;Lee, Sang Kyu;Lee, Ju Eun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, combustion and smoke release characteristics of a non-class 1E cable for nuclear power plants were investigated according to aging period. The aging was reproduced through an accelerated aging method for interval of 10 years :10, 20, 30 and 40 year, which was applied the Arrhenius equation. The cable was subjected to accelerated aging. In order to understand combustion and smoke release characteristics, the cone calorimeter test was performed according to the standard code of KS F ISO 5660-1. Heat release rate, mass loss rate, average rate of heat emission and smoke production rate were examined through cone calorimeter test. Fire performance index, fire growth index and smoke factor were derived from test results for the comparison of quantitative fire risk. When comparing the fire performance index and the fire growth index, the early fire risk tends to decrease as aging progresses, which might be attributed from the fact that the volatile substances of cables were evaporated. However, when comparing the heat release rate, average rate of heat emission and mass loss rate, which represent the mid and late periods of the fire risk, the values of accelerated aging cables were much higher than those of non-aged cable, which signifies the unstable formation of the char layer resulted in the change in the performance of flame retardants. In addition, the results from the smoke characteristics show that the accelerated aging cables were lager than the non-aged cables in terms of overall fire risk. These results can be used as baseline data when assessing fire risk of cables and establishing fire safety code for nuclear power plants.

Effect of Impact Angle on the Etching of Glass by Powder Blasting (Powder Blasting 을 이용한 유리의 표면부식시 분사각도의 영향)

  • 김광현;박경호;박동삼
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.349-354
    • /
    • 2001
  • In this study, we investigated the effect of the impacting ang1e of particles, the scanning times and the stand-off distance on the surface roughness and the weight-loss rate of samples with no mask, and the wall profile and overetching of samples with different mask pattern in powder blasting of soda-lime glass. The varying parameters were the different impact angles between 50$^{\circ}$ and 90$^{\circ}$, scanning times of nozz1e up to 40 and the stand-off distances 70mm and 100mm. The widths of mask pattern were 0.2mm, 0.5mm and 1mm. The powder was alumina sharp particles, WA#600. The mass flow rate of powder during the erosion test was fixed constant at 175g/min and the blasting pressure of powder at 0.2MPa

  • PDF

Mass Transfer during Osmotic Dehydration of Carrots and Its Effect on Browning Reaction (당근 삼투압 건조시 물질 이동과 갈색화 반응에 미치는 효과)

  • Kim, Myung-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.307-312
    • /
    • 1989
  • Internal mass transfer during osmotic dehydration of carrots in sugar solutions was examined as a function of concentration, temperature and immersion time of those solutions using moisture loss, sugar gain, molality and rate parameter. Influence of osmotic dehydration and blanching on browning reaction of vacuum dried carrots(3% MC: wet basis) was also evaluated. Increasing the concentration and temperature of sugar solutions increased moisture loss, sugar gain, molality and rate parameter. Water loss and sugar gain were rapid in first 4 min and then levelled off. The rate of sugar gain and molality changes on temperature was significant in lower concentration$(20^{\circ}\;Brix)$ compared to higher concentration$(60^{\circ}\;Brix)$. The changes of rate parameter were affected by concentration than by temperature of sugar solutions. Moisture loss during osmotic dehydration using a sugar solution $(60^{\circ}\;Brix,\;80^{\circ}C)$ with 20min immersion time was 55.7%. Effect of osmotic dehydration and blanching before vacuum dried to 3% MC(Wet basis) on browning reaction was significant. Minimum browning reaction during vacuum drying was carried out using pretreatments such as osmotic dehydration in sugar solution$(40^{\circ}\;Brix,\;80^{\circ}C)$ with 16 min immersion time(O.D.=0.09) and blanching with 12 min immersion time at $80^{\circ}C$(O.D.=0.31) compared to control(O.D.=1.59).

  • PDF

Corrosion Behaviour of Some Alloys in Tropical Urban and Marine Atmospheres

  • Dang, Vu Ngoan;Bui, Ba Xuan;Nguyen, Nhi Tru
    • Corrosion Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.125-129
    • /
    • 2008
  • Results of corrosion testing for different grades of titanium, copper, zinc, alluminium alloys and steels after two years of outdoor exposure under humid tropical urban and marine conditions have been presented and discussed. Mass loss and corrosion product characteristics for the exposed specimens at Hanoi testing site with high humidity and Nhatrang marine stations (at 100 and 1,000 meters distances from sea) with different airborne salinities (35.9 and $90.0mg/m^2.d$ respectively) have been selected for investigation. From time dependence of the specimen mass loss and corrosion product characteristics, the strong influence of environmental parameters upon durability for the investigated metals and alloys has been demonstrated. Only titanium alloys show high resistance to the marine conditions. All the other specimens (copper, zinc, alluminium alloys and steels) have been underwent strong deterioration under influence of aerosol salinity. Results of corrosion products analysis have been also presented for characterization of environmental impact on the metal degradation processes.

The Relationship between Flash Point and Fire Properties of Flammable Liquids (가연성 액체의 인화점과 화재특성치와의 관계)

  • Song, Young-Ho;Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.2 s.35
    • /
    • pp.10-14
    • /
    • 2007
  • Flash point is one of the major physical properties used to evaluate fire hazards of the combustible liquids. Properties showing relative fire hazards of the combustible liquids are heat release rate(HRR), peak heat release rate(PHRR), time to ignition(TTI), mass loss rate, and yield of $CO/CO_2$. The relationships between flash points and fire properties of the combustible liquids were examined in this study. For this study, mass loss rate and time to ignition were measured to calculate fire properties of the combustible liquids. The results showed that good correlations could be found between flash point and time to ignition, time to peak heat release rate, and the propensity to flashover. From a presented results, the parameters can be used to evaluate relative hazards of the combustible liquids on fire.

  • PDF

Gamitaeeumjowee-tang for Weight Loss in Post-Menopausal Obese Women: A Retrospective Chart Review (폐경 후 비만 여성의 체중감량을 위한 가미태음조위탕의 임상적 활용: 후향적 차트 리뷰)

  • Yun-Jin Lee;Jeong-In Kang;Yun-Ha Kim;Eun-Chae Min;Young-Woo Lim;Eunjoo Kim
    • The Journal of Korean Medicine
    • /
    • v.45 no.1
    • /
    • pp.65-79
    • /
    • 2024
  • Objectives: The purpose of this study is to evaluate weight change and analyze adverse events in post-menopausal obese women with Gamitaeeumjowee-tang for weight loss. Methods: A retrospective chart review was conducted for medical records of 115 post-menopausal obese women (body mass index, BMI≥25 kg/m2) who were administered with Gamitaeeumjowee-tang for 12 weeks for the purpose of weight loss. Weight, skeletal muscle ratio and BMI changes were compared before and after the program. Adverse events were evaluated by causality, severity and system-organ classes. Results: A total of 115 patients were included in this study. The average total weight loss in post-menopausal women was 5.72±2.04kg(p<0.001) and the average weight loss rate was 8.06±2.70%(p<0.001). After the 12-week program, the body fat rate was significantly decreased(3.76±2.20%)(p<0.001) and the skeletal muscle ratio was significantly increased(2.07±1.24%)(p<0.001). There were no significant differences in weight loss, skeletal muscle ratio change and body fat rate change depending on the number of hospital visits. Insomnia was frequently reported throughout the period, and no serious adverse events were reported. Conclusions: This study showed the potential that weight management treatment with Gamitaeeumjowee-tang could be a good way to lose weight of post-menopausal obese women without serious adverse events. Continuous well designed clinical studies are needed.

Performance test for the compressor of 100kW APU (100kW급 보조동력장치용 압축기 성능시험)

  • Lim, Byeung-Jun;Cha, Bong-Jun;Yang, Soo-Seok;Lee, Kyoung-Jin;Baik, Ki-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.655-660
    • /
    • 2001
  • The performance test of a centrifugal compressor for APU(Auxiliary Power Unit) which is developed by the collaborative research of KARI and Samsung TechWin has been conducted. The investigated compressor consists of a curved inlet, a centrifugal impeller, a channel diffuser and a plenum chamber. The experiments were carried out in an open-loop centrifugal compressor test rig driven by a turbine. For three different diffusers, overall performance data were obtained at 80%, 90% and 97% of design speed. For the initially designed wedge-type diffuser, test results showed that the compressor was operated at a higher mass flow rate than the design requirement. By reducing the diffuser throat area, the compressor operating range was shifted to lower mass flow rate range. The test result of redesigned wedge-type diffuser showed high pressure loss. To reduce the diffuser loss, diffuser inlet radius was increased and airfoil-type of diffuser was adopted. This airfoil-type diffuser showed reasonal results in terms of design requirement.

  • PDF

DETERMINATION OF WIND PARAMETERS BY THE METHOD OF DIFFERENTIAL CORRECTIONS (차등보정법에 의한 항성풍인자의 결정)

  • 김유경;강영운
    • Journal of Astronomy and Space Sciences
    • /
    • v.11 no.1
    • /
    • pp.107-114
    • /
    • 1994
  • This paper describes a method for the determination of wind parameters as mass-loss rate, wind velocity, stochastic velocity in Zeta Aurigae type binaries. We have modified the Baade's (1989) computer code to analyze the wind parameters of Zeta Aurigae type binaries according to the least squares criterion. The modified program adjusts the wind parameters by the method of differential corrections. We have appled this method to the IUE observations of 32 Cygni. We have fitted a theoretical line profile to the IUE observations of Fe II resonance line at various phases. The mass-loss rate, wind velocity and stochastic velocity of 32 Cygni obtained in this paper are $2.18{\times}10^{-8}M_{\odot}/yr$, 132.14km/s, 39.82km/s, respectively.

  • PDF

FORMATION OF LINE PROFILES BY THE WINDS OF EARLY TYPE STARS

  • KANG IVIIN-YOUNG;KIM KYUNG-MEE;CHOE SEUNG-URN
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.263-264
    • /
    • 1996
  • We have solved the radiative transfer problem using a Sobolev approximation with an escape probability method in case of the supersonic expansion of a stellar envelope to an ambient medium. The radiation from the expanding envelope turns out to produce a P-Cygni type profile. In order to investigate the morphology of the theoretical P-Cygni type profile, we have treated $V{\infty},\;V_{sto},\;{\beta}$ (parameter for the velocity field), M and $\epsilon$ (parameter for collisional effect) as model parametrs. We have found that the velocity field and the mass loss rate affect the shapes of the P-Cygni type profiles most effectively. The secondarily important factors are $V{\infty},\;V_{sto}$. The collisional effect tends to make the total flux increase but not so .much in magnitude. We have infered some physical parameters of 68 Cyg, HD24912, and $\xi$ persei such as V$\infty$, M from the model calculation, which shows a good agreement with the observational results.

  • PDF