• Title/Summary/Keyword: mass loss rate

Search Result 404, Processing Time 0.027 seconds

Influences of changes in the Thermal Properties on Pyrolysis of Solid Combustibles (열물성의 변화가 고체 가연물의 열분해에 미치는 영향)

  • Hong, Ter-Ki;Lee, Jong Won;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.41-48
    • /
    • 2017
  • In order to investigate the influence of changes in the thermal properties of solid combustibles on thermal decomposition, a series of solid pyrolysis experiments were performed using a cone calorimeter specified in KS F ISO 5660-1. In the present study, Poly Methyl Methacrylate (PMMA) which does not produce Char during pyrolysis process was used as solid fuel. Results obtained from cone calorimeter experiments were compared to ones obtained from numerical analysis of Fire Dynamics Simulator (FDS) 1D pyrolysis model adopted with thermal properties of solid fuel as input parameters. Comparisons between experimentally calculated and model-predicted mass loss rate were then made to elucidate the effect of changes in the thermal properties on pyrolysis of PMMA.

Technical Improvement Using a Three-Dimensional Video System for Laparoscopic Partial Nephrectomy

  • Komatsuda, Akari;Matsumoto, Kazuhiro;Miyajima, Akira;Kaneko, Gou;Mizuno, Ryuichi;Kikuchi, Eiji;Oya, Mototsugu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2475-2478
    • /
    • 2016
  • Background: Laparoscopic partial nephrectomy is one of the major surgical techniques for small renal masses. However, it is difficult to manage cutting and suturing procedures within acceptable time periods. To overcome this difficulty, we applied a three-dimensional (3D) video system with laparoscopic partial nephrectomy, and evaluated its utility. Materials and Methods: We retrospectively enrolled 31 patients who underwent laparoscopic partial nephrectomy between November 2009 and June 2014. A conventional two-dimensional (2D) video system was used in 20 patients, and a 3D video system in 11. Patient characteristics and video system type (2D or 3D) were recorded, and correlations with perioperative outcomes were analyzed. Results: Mean age of the patients was $55.8{\pm}12.4$, mean body mass index was $25.7{\pm}3.9kg/m^2$, mean tumor size was $2.0{\pm}0.8cm$, mean R.E.N.A.L nephrometry score was $6.9{\pm}1.9$, and clinical stage was T1a in all patients. There were no significant differences in operative time (p=0.348), pneumoperitoneum time (p=0.322), cutting time (p=0.493), estimated blood loss (p=0.335), and Clavien grade of >II complication rate (p=0.719) between the two groups. However, warm ischemic time was significantly shorter in the 3D group than the 2D group (16.1 min vs. 21.2min, p=0.021), which resulted from short suturing time (9.1 min vs. 15.2 min, p=0.008). No open conversion occurred in either group. Conclusions: A 3D video system allows the shortening of warm ischemic time in laparoscopic partial nephrectomy and thus may be useful in improving the procedure.

Adaptive Beam Selection Method for Improvement of Spectral Efficiency in Millimeter-Wave MIMO (밀리미터파 대역의 다중입출력 안테나 시스템에서 스펙트럼 효율 향상을 위한 적응적 빔 선택 기법)

  • Kim, Jun-Ho;Byun, Youn-Shik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.8
    • /
    • pp.890-895
    • /
    • 2016
  • As the wireless communication technique is developing rapidly, the use of smart devices is increasing. Due to gradually increasing data traffic, a new area, more than 6GHz of bandwidth to increase capacity of the network, has been studied. Millimeter Wave(MmWave) communications utilizes the bandwidth above 6GHz, which makes it possible to achieve one gigabit per second data rate. To overcome the path loss due to the smaller wavelength, the mass of the antenna arrangement is used. This paper presents an algorithm that maximizes the spectral efficiency of the system in the pre-coding process using a hybrid beamforming. Also it is suggested with the optimization of the number of beams that maximizes the spectral efficiency was maximized by the propose method.

Transient performance behaviour of the CRW type UAV propulsion system during flight mode transition considering valve operation (CRW형식 무인항공기 추진시스템의 밸브 작동을 고려한 비행모드 전환에 따른 천이 성능특성 연구)

  • Kong Chanduk;Park Jong-Ha;Yang Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.219-224
    • /
    • 2005
  • In order to investigate transient behaviour of the CRW(Canard Rotor Wing) type UAV(Uninhabited Aerial Vehicle) propulsion system during flight mode transition considering flow control valve operation, the propulsion system was modelled using SIMULINK commercial program. For transient simulation of the main engine system, the ICV(Inter-Component Volume) method was applied. The valve system is to control the gas flow of the rotary duct system and the main duct system, and the analysis was performed with an assumption that the total gas mass flow of the main engine is the same as summation of the rotary duct flow and the main duct flow, and with consideration of valve loss, flow rate and effective area in valve angle variation. The performance analysis was carried out during flight mode transitions from the rotary flight mode to the fixed wing flight mode and vice versa mode at altitude of 1Km, flight Mach number 0.1 and maximum engine rpm.

  • PDF

Development of a Surface Shape for the Heat Transfer Enhancement and Reduction of Pressure Loss in an Internal Cooling Passage (내부 냉각유로에서 열전달 강화와 압력손실 감소를 위한 표면 형상체의 개발)

  • Doo, Jeong-Hoon;Yoon, Hyun-Sik;Ha, Man-Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.427-434
    • /
    • 2009
  • A new surface shape of an internal cooling passage which largely reduces the pressure drop and enhances the surface heat transfer is proposed in the present study. The surface shape of the cooling passage is consisted of the concave dimple and the riblet inside the dimple which is protruded along the stream-wise direction. Direct Numerical Simulation (DNS) for the fully developed turbulent flow and thermal fields in the cooling passage is conducted. The numerical simulations for five different surface shapes are conducted at the Reynolds number of 2800 based on the mean bulk velocity and channel height and Prandtl number of 0.71. The driving pressure gradient is adjusted to keep a constant mass flow rate in the x direction. The thermoaerodynamic performance for five different cases used in the present study was assessed in terms of the drag, Nusselt number, Fanning friction factor, volume and area goodness factor in the cooling passage. The value of maximum ratio of drag reduction is -22.86 %, and the value of maximum ratio of Nusselt number augmentation is 7.05% when the riblet angle is $60^{\circ}$. The remarkable point is that the ratio of Nusselt number augmentation has the positive value for the surface shapes which have over $45^{\circ}$ of the riblet angle. The maximum volume and area goodness factors are obtained when the riblet angle is $60^{\circ}$.

Use of the Tenocutaneous Free Flap In Hand Reconstruction (유리 건 피판을 이용한 수부 재건술)

  • Chung, Duke-Whan;Han, Chung-Soo;Kim, Ki-Bong;Yi, Jin-Woong
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.2
    • /
    • pp.93-98
    • /
    • 2001
  • Purpose : This describes our experience with a tenocutaneous free flap from the dorsum of the foot or radial forearm to reconstruct the dorsal skin and extensor tendons of the hand. Material and Methods : Between february 1987 and July 1998, we treated 9 patients with composite tissue loss on the dorsal hand caused by crushing injury. Nine men had an average age of 26.4 years(range, $19{\sim}47$). We treated 5 patients with the free dorsalis pedis flap including the extensor tendons and the superficial peroneal nerve and 4 patients with reverse forearm flap including the brachioradialis tendon and/or superficial radial nerve. Flap size was average 4.4(3,2cm. Evaluation of the results was based on the survived flap rate, the recovery rates for range of motion of the metacarpophalageal joints in the operated fingers. two-point discrimination. Results : All flaps were well vascularized and survived completely. Recovery rates for range of motion of the metacarpophalageal joints in operated fingers range from $78%{\sim}99%$(average, 90%). Two-point discrimination of the transferred flaps in 5 patients average $20{\pm}3.5mm$. Conclusion : The advantages of this procedure are mass action reconstruction with tendon, one-stage operation, faster healing with less adhesion formation, and early mobilization.

  • PDF

Numerical Investigation on Soot Primary Particle Size Using Time Resolved Laser Induced Incandescence (TIRE-LII) (시분해 레이저 유도 백열법을 이용한 매연 입자 크기에 관한 수치적 연구)

  • Lee, Jong-Ho;Kim, Jeong-Yong;Jeong, Dong-Soo;Chang, Young-June;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.9 s.240
    • /
    • pp.1022-1031
    • /
    • 2005
  • Temporal behavior of the laser induced incandescence (LII) signal is often used for soot particle sizing, which is possible because the cooling behavior of a laser heated particle is dependent on the particle size. In present study, LII signals of soot particles are modeled using two non-linear coupled differential equations deduced from the energy- and mass-balance of the process. The objective of this study is to obtain an appropriate calibration curve for determining primary particle size by comparing the gated signal ratio and double-exponential curve fitting methods. Not only the effects of laser fluence and gas temperature on the cooling behavior but also heat transfer mechanisms of heated soot particle have been investigated. The second-order exponential curve fitting showed better agreements with the LII signals than the gated signal ratio method which was based on the lust-order exponential curve fit. And the temporal decay rate of the LII signal and primary particle size showed nearly linear relationship, which was little dependent on the laser fluence. And it also could be reconfirmed that vaporization was dominant process of heat loss during first loons after laser pulse, then heat conduction played most important role while thermal radiation had little influence all the time.

A Study on Properties of Concrete Made of Natural and Crushed Sand in High Temperatures (자연모래와 부순모래를 사용한 콘크리트의 고온 하에서 특성연구)

  • Kim, Joo-Seok;Choi, Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.53-60
    • /
    • 2012
  • The main object of this paper is to investigate the effects of high temperatures on the physical and mechanical properties of natural sand concrete(NSC) and crushed sand concrete(CSC). Test samples were exposed to high temperature ranging from $200^{\circ}C$ to $800^{\circ}C$. After exposure, various tests were conducted. Color image analysis and weight losses were determined and compressive strength test and splitting tensile strength test were conducted. The results indicated that weight losses increased as exposure temperature increased with comparable decreasing rate. The results also showed that compressive strength and splitting tensile strength and modulus of elasticity decreased as exposure temperature increased. The results also showed that residual compressive strength of NSC decreased more drastically than that of CSC at $200^{\circ}C$ and $400^{\circ}C$. Residual splitting tensile strength of NSC decreased more than that of CSC at $200^{\circ}C$, while NSC and CSC showed comparable residual strength ratio at $800^{\circ}C$.

Thermomechanical Analysis of Composite Structures in Pyrolysis and Ablation Environments (열분해 및 삭마 환경의 복합재 구조물의 열기계적 연계 해석)

  • Choi, Youn Gyu;Kim, Sung Jun;Shin, Eui Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.8
    • /
    • pp.597-604
    • /
    • 2013
  • A coupled thermomechanical analysis of composite structures in pyrolysis and ablation environments is performed. The pyrolysis and ablation models include the effects of mass loss, pore gas diffusion, endothermic reaction energy, surface recession, etc. The thermal and structural analysis interface is based upon a staggered coupling algorithm by using a commercial finite element code. The characteristics of the proposed method are investigated through numerical experiments with carbon/phenolic composites. The numerical studies are carried out to examine the surface recession rate by chemical and mechanical ablation. In addition, the effects of shrinkage or intumescence during the pyrolysis process are shown.

Analysis of Heat Exchanging Performance of Heat Recovering Device Attached to Exhaust Gas Duct (열회수장치에 의한 열회수성능 분석)

  • 서원명;윤용철;강종국
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.212-222
    • /
    • 2000
  • This study was performed to investigate the performance of heat recovery device attached to exhaust gas flue connected to combustion chamber of greenhouse heating system. The experimental heat recovery system is mainly consisted of LPG combustion chamber and two heat recovery units; unit-A is attached directly to the exhaust gas flue, and unit-B is connected with unit-A. Heat recovery performance was evaluated by estimating total energy amounts by using enthalpy difference between two measurement points together with mass flow rate of gas and/or air passing through each heat recovery unit depending on 5 different flow rates controlled by voltage meter. The results of this experimental study, such as heat exchange behavior of supply air tubes and exhaust air passages crossing the tubes, pressure drop between inlet and outlet, heat recovery performance of exchange unit, etc., will be used as fundamental data for designing optimum heat recovery device to be used for fuel saving purpose by reducing heat loss amounts mostly wasted outside of greenhouse through flue.

  • PDF