• Title/Summary/Keyword: mass formula

Search Result 266, Processing Time 0.025 seconds

Calculation Formula for Effective Photon Energy in kV X-ray Beam of Mammography (유방촬영의 kV X-선 빔에서 유효광자에너지에 대한 계산식)

  • Young-On Park;Sang-Hun Lee;Jong-Eon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.507-514
    • /
    • 2023
  • The purpose of this study is to find a formula that can easily calculate the effective photon energy in the X-ray beam of mammography. The tube voltage measured for each set tube voltage was obtained using the X2 MAM Sensor. The mass attenuation coefficient for aluminum of the aluminum filter was obtained from the half value layer measurement from each measured tube voltage X-ray beam. The mass attenuation coefficient of aluminum obtained from each measured tube voltage X-ray beam was corresponded to the mass attenuation coefficient of aluminum for each photon energy obtained from NIST. The photon energy corresponding to the matching mass attenuation coefficient was determined as the effective photon energy. The formula for calculating the determined effective photon energy was obtained by polynomial matching of the effective photon energy for each tube voltage in the Origin pro 2019b statistical program as y = 28.98968-1.91738x + 0.07786x2-0.000946717x3. Here, x is the measuring tube voltage and y is the effective photon energy. The calculation formula of the effective photon energy of the mammography X-ray beam obtained in this study is considered to be very useful in obtaining the interaction coefficient between the X-ray beam and a certain substance in clinical practice.

Theoretical Analysis for the Measurement of Viscosity and Shear Modulus of Viscoelastic Fluids by Using a Quartz Crystal Oscillator (수정진동자를 사용한 점탄성 유체의 점성계수와 전단 탄성계수 측정에 관한 이론해석)

  • Suh, Yong-Kweon;Kim, Young-Han
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.7
    • /
    • pp.487-496
    • /
    • 2008
  • Quartz crystal oscillator is frequently used in measuring a very small amount of mass attached to or adsorbed on the surface of an electrode on the quartz plate. The physical principle is that the resonance frequency of the shear vibration of the quartz caused by an applied electric field is a function of the mass. Recently, effort has been tried to measure physical properties of viscoelastic fluids, such as viscosity and shear modulus. This paper presents useful formula that can be used in estimating the properties of viscoelastic fluids. Important finding in this analysis is that the formula can produce multiple values for the physical properties of the viscoelastic materials.

I-PD Controller Design of Motor Speed Control in a Two-Mass Motor Drive system (2관성 모터 시스템의 속도제어를 위한 I-PD제어기 설계)

  • Shim, Yong-Hun;Suh, Byung-Suhl
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.42-45
    • /
    • 2002
  • In the two-mass motor drive system driving a load through a flexible shaft or transmission system, a shaft torsional vibration is often generated. The overshoot of the motor drive system easily causes vibration. In this case I-PD controller has been generally used in speed control, because of the simplicity of structure. This paper using an analytical pole assignment design, proposes the overshoot formulas, and the settling time formula. The objective of this paper is to provide a design method of I-PD controller by using overshoot formulas, and settling time formula. The simulation results show that we can design the controller with desired overshoot and settling time.

  • PDF

MPS eutectic reaction model development for severe accident phenomenon simulation

  • Zhu, Yingzi;Xiong, Jinbiao;Yang, Yanhua
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.833-841
    • /
    • 2021
  • During the postulated severe accident of nuclear reactor, eutectic reaction leads to low-temperature melting of fuel cladding and early failure of core structure. In order to model eutectic melting with the moving particle semi-implicit (MPS) method, the eutectic reaction model is developed to simulate the eutectic reaction phenomenon. The coupling of mass diffusion and phase diagram is applied to calculate the eutectic reaction with the uniform temperature. A heat transfer formula is proposed based on the phase diagram to handle the heat release or absorption during the process of eutectic reaction, and it can combine with mass diffusion and phase diagram to describe the eutectic reaction with temperature variation. The heat transfer formula is verified by the one-dimensional melting simulations and the predicted interface position agrees well with the theoretical solution. In order to verify the eutectic reaction models, the eutectic reaction of uranium and iron in two semi-infinite domains is simulated, and the profile of solid thickness decrease over time follows the parabolic law. The modified MPS method is applied to calculate Transient Reactor Test Facility (TREAT) experiment, the penetration rate in the simulations are agreeable with the experiment results. In addition, a hypothetical case based on the TREAT experiment is also conducted to validate the eutectic reaction with temperature variation, the results present continuity with the simulations of TREAT experiment. Thus the improved method is proved to be capable of simulating the eutectic reaction in the severe accident.

A Study on the Approximate Formula for Radiation Efficiency of a Simply Supported Rectangular Plate in Water (단순지지 사각 접수 평판의 방사효율 근사식에 관한 연구)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kim, Bong-Ki;Kim, Sang-Ryul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.1
    • /
    • pp.21-27
    • /
    • 2014
  • In this paper, an approximate formula for radiation efficiency of the plate surround by an infinite rigid baffle is studied. The plate is simply supported and one side is in contact with air, while other side with water. By assuming an infinite plate, the fluid loading effect is derived in terms of an effective mass. Based on the observation that the fluid loading effect decreases as frequency increases, the radiation efficiency formula at high frequency, which was originally derived for a plate vibrating in the air, is modified as the approximate formula for a submerged plate. The fluid loading effect is taken into account in the wavenumber of the plate. Comparisons of the approximate formula with the numerical results shows that they match well except the mid-frequency range in which numerical results show many oscillations. In numerically solving the fully coupled equations of motion, fourfold integrals of the impedance coefficients are reduced to single nonsingular integrals, which results in substantial reduction in computing time.

Clinical Trial of Herbal formula (Slim-diet) on Weight Loss in Obese Pre-menopausal Korean Females (비만환자의 체중감량에 있어 슬림다이어트 처방의 유용성 평가를 위한 임상시험)

  • Chung, Won-Suk;Shin, Hyun-Dae;Song, Mi-Yeon
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • Background: Recently, Obesity has become a social problem in all over the world including Korea. Dietary regulation, exercise and behavior modification therapy are used in the treatment of obesity, but until now, there have been many difficulties in treating it. Objectives: To examine in obese pre-menopausal Korean females the short-term efficacy for weight loss of an herbal formula (Slim-diet). Design: A 6-week longituidinal evaluation of a herbal formula (Slim-diet) in 35 pre-menopausal females (baseline age $31.6\;{\pm}\;6.1$) with body mass index > $25kg/m^2$. Body composition was measured using bioimpedence analysis (BIA) and dual energy X-ray absorptiometry (DXA). Anthropometry was done by same observer. Total cholesterol, total lipid, triglyceride, and LDL-cholesterol were measured. Results: Herbal formula (Slim-diet) treatment produced significant loss of weight (P < 0.001), percent of body fat (P < 0.001, both BIA and DXA) and waist circumference (P < 0.001). It also produced significant reduction of total cholesterol and total lipid levels (P < 0.05).

  • PDF

Analytical Methods of Leakage Rate Estimation from a Containment tinder a LOCA (냉각수상실 사고시 격납용기로부터 누출되는 유체유량 추산을 위한 해석적 방법)

  • Moon-Hyun Chun
    • Nuclear Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.121-129
    • /
    • 1981
  • Three most outstanding maximum flow rate formulas are identified from many existing models. Outlines of the three limiting mass flow rate models are given along with computational procedures to estimate approximate amount of fission products released from a containment to environment for a given characteristic hole size for containment-isolation failure and containment pressure and temperature under a loss of coolant accident. Sample calculations are performed using the critical ideal gas flow rate model and the Moody's graphs for the maximum two-phase flow rates, and the results are compared with the values obtained from the mass leakage rate formula of CONTEMPT-LT code for converging nozzle and sonic flow. It is shown that the critical ideal gas flow rate formula gives almost comparable results as one can obtain from the Moody's model. It is also found that a more conservative approach to estimate leakage rate from a containment under a LOCA is to use the maximum ideal gas flow rate equation rather than tile mass leakage rate formula of CONTEMPT-LT.

  • PDF

High-Throughput Active Compound Discovery using Correlations between Activity and Mass Profiles

  • Park, Kyu-Hwan;Yoon, Kyo-Joong;Kwon, Kyung-Hoon;Kim, Hyun-Sik
    • Mass Spectrometry Letters
    • /
    • v.1 no.1
    • /
    • pp.13-16
    • /
    • 2010
  • The active components in a plant extract can be represented as mass profiles. We introduce here a new, multi-compound discovery method known as Scaling of Correlations between Activity and Mass Profiles (SCAMP). In this method, a correlation coefficient is used to quantify similarities between the extract activity and mass profiles. The method was evaluated by first measuring the anti-oxidation activity of eleven fractions of an Astragali Radix extract using DPPH assays. Next, 15 T Fouriertransform ion cyclotron resonance (FT-ICR) MS was employed to generate mass profiles of the eleven fractions. A comparison of correlation coefficients indicated two compounds at m/z 285.076 and 286.076 that were strong antioxidants. Principal component analyses of these profiles yielded the same result. FT-ICR MS, which offers a mass resolving power of 500,000, was used to discern isotopic fine structures and indicated that the molecular formula corresponding to the peak at m/z 285.076 was $C_{16}H_{13}O_5$. SCAMP in combination with high-resolution MS can be applied to any type of mixture to study pharmacological activity and is a powerful tool for active compound discovery in plant extract studies.

Comparison of LDL-Cholesterol direct measurement with the estimate using various formula

  • Kwon, Se Young;Na, Young-Ak
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.3
    • /
    • pp.103-111
    • /
    • 2012
  • Low-Density Lipoprotein cholesterol (LDLC) is the most important marker for the treatment of hyperlipidemia in NCEP-ATP III(National Cholesterol Education Program-Adult Treatment Panel III) guideline. Therefore, LDL cholesterol is pathologically meaningful, accurate measurement should be a top priority. Currently, LDLC is directly measured in most cases, but, the estimate is still used in mass health examination or screening test. This study is about the comparison of LDL-Cholesterol direct measurement with the estimate using various formula (Friedewald: [LDL-F=TC-HDL-TG/5], Nakajima: [LDL-N=TC-HDL-TG/4], Hattori: [LDL-H =0.94TC-0.94HDL-0.19TG], Puavilai: [LDL-P=TC-HDL-TG/6], Carvalho: [LDL-C=3(TC-HDL)/4]) for calculating more accurate value. We analyzed total cholesterol (TC), try-glyceride (TG), high-density lipoprotein cholesterol (HDLC), and LDLC levels of 210 subjects between June and November in 2011. Until now, the Friedewald formula is the most commonly used estimate for the LDLC. When Friedewald formula was applied, the correlation coefficient (r) was 0.940, showing high correlation. But, the result of the direct method was significantly different, compared with those of the Friedewald formula in triglyceride levels ${\geq}400mg/dL$(p<0.05). There was the highest correlation when we used LDL-P formula(r=0.947) in triglyceride levels <400 mg/dl. Also there was the lowest mean difference regardless of triglyceride level. Therefore, the study showed that TG/6 is more precise means of calculation than TG/5. On the other hand, the calculation of LDL-Cholesterol was underestimated, compared with direct measurement. It is necessary to have more data and modified Friedewald formula should be used for the accurate calculation.

  • PDF

The Effects of Mass Loss on the Pre-Main Sequence Evolutionary Tracks of Stein's Model Stars

  • Um, In-Kyung
    • Publications of The Korean Astronomical Society
    • /
    • v.1 no.1
    • /
    • pp.1-8
    • /
    • 1984
  • Under the context of Stein's linear theory of stellar models, the luminosity-effective temperature relationship is derived for contracting pre-main sequence stars which are losing mass, according to the empirical formula, given by Reimers (1975). The effects of mass loss on their evolution are investigated by calculating evolutionary tracks of 1. $1.5M_{\odot}$, $5M_{\odot}$, and $10M_{\odot}$, stars. Our calculations reveal that the effects of mass loss show up in the radiative equilibrium stage of the evolution. It is found that an increase of mass loss rate leads to delay the onset of radiative equilibrium, thus resulting in under-luminous main sequence stars. It is also noted that the mass loss prolongs the pre-main sequence life time. Detailed results of the calculations are discussed.

  • PDF