• Title/Summary/Keyword: mass concrete

Search Result 892, Processing Time 0.026 seconds

The Reduction of Maximum Hydration Temperature in Cement Paste Using Calcium Silicate Hydrates and Glucose (칼슘실리케이트 수화물과 포도당을 이용한 시멘트 페이스트의 최대 수화온도 저감)

  • Moon, Hoon;Kim, Hyeong-Keun;Ryu, Eun-Ji;Jin, Eun-Ji;Chung, Chul-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.3
    • /
    • pp.265-272
    • /
    • 2015
  • In this study, a method to reduce temperature rise due to hydration in mass concrete is investigated. It is to use retarder (glucose) for reducing heat of hydration and to use calcium silicate hydrate (C-S-H) for compensating the retardation effect due to its role as a nucleation seed. For this purpose, the temperature rise of cement paste due to hydration was measured and the effect of using both C-S-H and glucose on setting and 28-day compressive strength of mortar specimens was investigated. According to the experimental results, using C-S-H and glucose caused the reduction in the maximum temperature but accelerated the time to reach the maximum temperature compared to that of retarded cement paste using glucose. In addition, using C-S-H and glucose did not show significant effect on 28-day compressive strength of mortar specimens, indicating that the method shown in this study can be a successful alternative to control maximum temperature rise in mass concrete.

Optimum Binder Ratio of Mass Concrete for LNG Tank (LNG저장시설 적용을 위한 매스콘크리트 최적 결합재 혼입율 검토)

  • Kim, Young-Jin;Park, Sang-Jun;Kim, Kyoung-Min;Lee, Eui-Bae
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.240-245
    • /
    • 2013
  • The optimum binder ratio of the low heat mass concrete for LNG tank was evaluated in the present study. Three types of binder such as OPC I, ground granulated blast-furnace slag powder were mixed and were used. Also fine particle cement and activator were used to raise an early age strength development and ground limestone was used to reduce the cost. As a result of the study, mix ratio II (30:30:40) was suitable for Bottom Center and mix ratio III(40:30:30) was suitable for Roof based on compressive strength and semi-adiabatic temperature.

Seismic control of concrete buildings with nonlinear behavior, considering soil structure interaction using AMD and TMD

  • Mortezaie, Hamid;Zamanian, Reza
    • Structural Engineering and Mechanics
    • /
    • v.77 no.6
    • /
    • pp.721-734
    • /
    • 2021
  • The seismic analysis of structures without applying the effects of soil can undermine functional objectives of structure so that it can affect all the desired purposes at the design and control stages of the structure. In this research, employing OpenSees and MATLAB software simultaneously and developing a definite three-dimensional finite element model of a high-rise concrete structure, designed using performance-based plastic design approach, the performance of Tuned Mass Damper (TMD) and Active Mass Damper (AMD) is both examined and compared. Moreover some less noted aspects such as nonlinear interaction of soil and structure, uplift, nonlinear behavior of structure and structural torsion have received more attention. For this purpose, the analysis of time history on the structural model has been performed under 22 far-field accelerogram records. Examining a full range of all structural seismic responses, including lateral displacement, acceleration, inter-story drift, lost plastic energy, number of plastic hinges, story shear force and uplift. The results indicate that TMD performs better than AMD except for lateral displacement and inter-story drift to control other structural responses. Because on the one hand, nonlinear structural parameters and soil-structure interaction have been added and on the other hand, the restriction on the control force applied that leads up to saturation phenomenon in the active control system affect the performance of AMD. Moreover, the control force applied by structural control system has created undesirable acceleration and shear force in the structure.

Temperature History of Mock-up Mass Concrete Considering Different Heat Generation Due to Mixture Adjustment (수화발열량이 다른 콘크리트조합 모의부재 매스콘크리트의 온도이력 특성)

  • Kim Jong;Jeon Chung-Keun;Shin Dong-An;Yoon Gi-Won;Oh Seon-Kyo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.9-12
    • /
    • 2005
  • This paper investigated the temperature history of mass concrete mock up structure considering different heat generation by varying with mixture proportion. Setting time difference between high early strength mixture (E-P) and retarding mixture (R-F30) was 14.5hours. Incorporation of $30\%$ of fly ash contributed to $10^{\circ}C$ of hydration heat reduction. In generally used C and D combination, bottom concrete shows earlier hydration, while E-J combination showed reverse tendency and thus, this method can reduce the crack occurrence. Therefore, heat generation difference method has beneficial effect on reducing crack induced by hydration heat resulting from heat generation difference between surface and center section.

  • PDF

Dispertion Effect of Hydration Heat due to Materials and Standard Variation of Embedded Heat Pipe (매입형 히트파이프의 재질 및 규격변화에 따른 수화열 분산 효과)

  • Kim, Myung-Sik;Yeom, Chi-Sun;Baek, Dong-Il
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.6
    • /
    • pp.111-116
    • /
    • 2009
  • The cracking due to hydration heat in mass concrete must be resolved to improve the stability and durability of concrete structures. In this study, the economic efficiency was improved by replacing a copper pipe with a steel one for the heat pipe, and the heat pipe was standardized to significantly improve the operation efficiency, such as the processing, transport, assembly, and construction time. As a result of the experiment, the peak temperature of the ICSHP, ISSHP, and ISUHP specimens decreased by about $7.2{\sim}10.9^{\circ}C$ compared to the OPC specimen and the probability of a thermal crack being generated in the ICSHP, ISSHP, and ISUHP specimens decreased by up to 84~88%.

Evaluation of Durability Properties of Cement Matrix Using the Polymer of Powder Type (분말형 폴리머를 사용한 시멘트 경화체의 내구성 평가)

  • Kim, Seong-Soo;Jung, Ho-Seop;Lee, Jeong-Bae;Yoon, Ha-Young;Koh, Joon-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.495-498
    • /
    • 2005
  • It was investigated the durability of the concrete to improve construction materials with polymer cement mortar in this study. With the popularity of repair and rehabilitation material, some mixtures composed of Ethylene Vinyl Acetate(EVA) was studied. Ethylene Vinyl Acetate(EVA) carried out tests to determine its properties which a include: freezing-thawing resistance test, carbonation test, and chemical resistance test. Result of freezing-thawing resistance test, mass change ratio and chemical resistance test, mass change ratio decreased of 12 and $15\~45\%$ as compared with control mortar. Carbonation depth decreased $3.7\~5.6mm$ as polymer-cement ratio increased $1\~4\%$.

  • PDF

Seismic Response Control of Nonlinear Hysteretic Structures Using Tuned Mass Damper (동조질량감쇠기를 이용한 비선형이력 구조물의 지진응답제어)

  • Lee, Sang-Hyun;Chung, Lan;Woo, Sung-Sik;Lee, Joung-Woo;Choi, Ki-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.206-209
    • /
    • 2006
  • This study presents the performance evaluation of a tuned mass damper (TMD) for controlling seismic responses of the nonlinear hysteretic structure represented by a Bouc-Wen model, considering that the general reinforce concrete building structures subject to earthquake load show nonlinear hysteretic behavior. Numerical analysis result indicates that the performance of a passive TMD of which design parameters are optimized for a elastic structure deteriorates when the hysteretic portion of the structural responses increases, while a semi-actively operated TMD shows about 15-40% more response reduction than the TMD.

  • PDF

Shaking Table Test of Small Scale RC Structure with Tuned Liquid Damper (동조액체 감쇠기를 설치한 철근콘크리트 축소모델의 진동대 실험)

  • Woo, Seang-Sik;Lee, Sang-Hyun;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.113-116
    • /
    • 2005
  • In this study, in order to. investigate the effectiveness af tuned liquid damper (TLD) for the seismic performance enhancement af the existing reinforced concrete (RC) apartment structure which is nat seismically designed, shaking table test was conducted for the small scale five stary RC structure with TLD. TLD model was constructed to. have the frequency tuned to. the first modal frequency af the structure, $2\%$ mass ratio. af the first modal mass, and 0.08 liquid depth ratio. White noise with $0.2\~5Hz$ frequency bandwidth tests were performed using the shaking table at Korea Institute af Machinery and Materials, and the displacement and absolute acceleration af each floor were measured. Test results indicate that mare than $30\%$ seismic responses reduction can be achieved using TLD for RC structure under white noise.

  • PDF

Development of Polypropylene Fiber Reinforced Environmental Friendly Pavement Material for Farm Road (폴리프로필렌 섬유보강 환경친화형 포장재료의 개발)

  • Sung, Chan-Yong;Kim, Young-Ik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.1
    • /
    • pp.35-40
    • /
    • 2004
  • This study is performed to examine the physical and mechanical properties of eco-concrete using soil, natural coarse aggregate, excellent soil compound and polypropylene fiber. The test result shows that mass loss ratio is decreased with increasing the content of coarse aggregate and excellent soil compound. The compressive and flexural strengths are increased with increasing the content of coarse aggregate, excellent soil compound and polypropylene fiber. The coefficient of permeability is decreased with increasing the content of coarse aggregate and excellent soil compound, but it is increased in 0.2% polypropylene fiber content. The lowest coefficient of permeability is showed in $5.066\times 10^{-9}$cm/s. These eco-concrete can be used for farm road.

Properties of Low Heat Portland(Belite Rich) Cement Concrete (저열 포틀랜드(벨라이트)시멘트 콘크리트의 특성)

  • 하재담;김기수;김동석;구본창;조계홍;이동윤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.66-71
    • /
    • 1998
  • Recently, it has been increased to construct massive concrete structures, like under-ground structure, offshore structure etc., ie. concrete construction have become larger and higher and are demanding lower heat concrete to prevent thermal cracking. It has been progressed to replace cements with fly-ash and slag to lower heat of hydration, but it is hard to control quality of the mineral admixtures in stage of adjusting of real construction. Application of low heat portland(Belite Rich) cement for the mass concrete is the best solution to satisfied those requirements. Here are explained the basic properties of fresh concrete as well as hardened concrete of using low heat portland cement(LHPC). Also, we compare the results of adiabatic temperature rise test using LHPC and OPC.

  • PDF