• 제목/요약/키워드: masonry building

검색결과 196건 처리시간 0.024초

건식벽체에서 접착제 종류에 따른 타일부착 안전성 평가에 관한 연구 (A Study of the appraisal for adhesive stability classified by tile bond agent on the dry wall surface)

  • 엄찬용;선윤숙;권시원;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.173-178
    • /
    • 2005
  • The tile construction methods for existing have been used materials within limit which adhesion by wet method in masonry wall and concrete structure. These existing adhesive tech can caused many problems in construction of large and reform tile, after that it can be happened loose scale, peel off, falling off tile by heat and vibration or impact. In according to, this study is to test tile for bond stability, adhesive property by impact, vibration. low property by heat and then, we have the results as below; (1) The tile adhesive stability can be effected as adhesive area between bond agent and tile, adhesive area can more wide and press enough to ensure property. (2) Existing adhesive strength and standard relative tile construction is limited to adjust performance tile on the concrete and masonry wall. In summary, It is necessary to establish standard of performance and test method to ensure tile adhesive salability in dry wall.

  • PDF

아라미드 스트립을 이용한 학교건축물의 내진성능 보강방안에 관한 실험적 연구 (Experimental Study on Seismic Retrofitting Methods for School Building using Aramid Strip)

  • 김혜진;박태원;조승호;이경구;노영숙;정란
    • 한국안전학회지
    • /
    • 제25권3호
    • /
    • pp.100-106
    • /
    • 2010
  • Most of the school buildings were built before the seismic code was established. To consider the sunlight and ventilation to the partition walls are built about 1m height beside columns at typical school buildings. For the reason, columns which is consisted school building occur brittle failure shape by the reduced effective depth. In this study, experimental test for retrofitting effect by Aramid Fiber Reinforced Polymers(AFRP) strips on masonry infilled reinforced concrete(RC) frames is performed. The test results were to ensured enough time to evacuate due to the enhancement of ductility and strength of school buildings to withstand earthquakes using AFRP strips.

사인파형 웨브주름 보강재를 이용한 저층건물의 내진보강에 관한 연구 (A Study on the Seismic Reinforcement of a Low-Rise Building Using Sinusoidal Corrugated Web Members)

  • 정동조;김진
    • 한국농촌건축학회논문집
    • /
    • 제24권2호
    • /
    • pp.13-20
    • /
    • 2022
  • In this study, a general low-rise building was selected to compare the new shear wall reinforcement method, which is a general method among the existing reinforcement methods, and the reinforcement method using sinusoidal corrugated web reinforcement. And it was confirmed that the following effects can be expected. Sinusoidal corrugated web members can be carried out in a short period of time as it does not require the removal of the masonry filling wall, the reinforcement of reinforcing bars, and the curing period of the concrete. It is effective in preventing damage that may occur when masonry filling wall is overturned in the out-of-plane direction, and the burden of the foundation is also reduced, and thus the construction period and cost required for reinforcement can greatly be reduced. By adjusting the number of sinusoidal corrugated web member, details of joints, and reinforcement positions, the flow of load can be induced to have an advantageous effect on the building. It can be considered as the most suitable reinforcement plan in terms of life safety. Unlike the shear wall that fills between the columns, the sinusoidal corrugated web members, which has a width of 1.5m, can install openings between two columns depending on the purpose of use, and can be expected to have a great effect in terms of usability due to its free installation location. As mentioned above, the seismic reinforcement using a sinusoidal corrugated web members, can expect great effect compared to conventional reinforcement methods in terms of usability, economic feasibility, and stability.

비보강 조적식 구조의 형상에 따른 내진성능 평가 해석 (Effect of Physical Shape on Seismic Performance of URM Structures)

  • 박주남
    • 한국지진공학회논문집
    • /
    • 제20권5호
    • /
    • pp.277-283
    • /
    • 2016
  • Unreinforced masonry (URM) buildings are known to be highly vulnerable to seismic loadings. Although significant physical variation may exist for URM buildings that fall into a same structural category, a single set of fragility curves is typically used as a representation of the seismic vulnerability of the URM structures. This study investigates the effect of physical variation of URM structures on their seismic performance level. Variables that describe the physical variation of the structure are defined based on the inventory analysis. Seismic behavior of the structures is then monitored by changing the variables to investigate the effect of each variable. The analysis results show that among the variables considered the seismic performance of URM building depends on the variation of the width, the aspect ratio, and the number of story. The need for further research on the modeling of the connections between the walls and diaphragms and the torsional effect is also addressed.

조적조 비내력벽을 가진 기존 학교 구조물의 내진 성능평가 (Evaluation of Performance of Korean Existing School Buildings with Masonry Infilled Walls Against Earthquakes)

  • 문기훈;전용률;이창석;한상환
    • 한국지진공학회논문집
    • /
    • 제16권6호
    • /
    • pp.37-46
    • /
    • 2012
  • In Korea, most existing school buildings have been constructed with moment frames with un-reinforced infill walls designed only considering gravity loads. Thus, the buildings may not perform satisfactorily during earthquakes expected in Korea. In exterior frames of the building, un-reinforced masonry infill walls with window openings are commonly placed, which may alter the structural behavior of adjacent columns due to the interaction between the wall and column. The objective of this study is to evaluate the seismic performance of existing school buildings according to the procedure specified in ATC 63. Analytical models are proposed to simulate the structural behavior of columns, infill walls and their interaction. The accuracy of the proposed model is verified by comparing the analytical results with the experimental test results for one bay frames with and without infill walls with openings. For seismic performance evaluation, three story buildings are considered as model frames located at sites having different soil conditions ($S_A$, $S_B$, $S_C$, $S_D$, $S_E$) in Korea. It is observed that columns behaves as a short columns governed by shear due to infill masonry walls with openings. The collapse probabilities of the frames under maximum considered earthquake ranges from 62.9 to 99.5 %, which far exceed the allowable value specified in ATC 63.

파이버 및 전단 스프링요소를 이용한 비보강 조적벽체의 비선형 해석모델 (Nonlinear Analytical Model of Unreinforced Masonry Wall using Fiber and Shear Spring Elements)

  • 홍정모;신동현;김형준
    • 한국전산구조공학회논문집
    • /
    • 제31권6호
    • /
    • pp.283-291
    • /
    • 2018
  • 본 연구는 지진에 저항하는 부재인 비보강 조적벽체로 구성된 건물의 내진성능평가에 활용되는 비선형 정적해석을 위한 비보강 조적벽체의 해석모델을 수립하고자 하였다. 본 연구의 해석모델은 비보강 조적벽체의 휨거동을 모사하기 위한 파이버 요소와 비보강 조적벽체의 전단에 대한 응답을 예측하기 위한 전단스프링 요소로 구성된다. 본 논문은 먼저 제안하고 있는 모델의 형상에 대해서 설명하고, 기존에 행해진 조적조 프리즘의 실험결과로부터 얻은 응력-변형률 곡선을 근거로 파이버와 전단스프링 요소의 물성치에 대한 결정 방법을 설명한다. 제시하고 있는 모델은 비선형 정적 해석결과와 다른 연구자들에 의해 수행된 실험결과를 비교하여 타당성을 검증한다. 해당 모델은 최대강도, 초기강성, 그리고 이들로부터 얻어지는 비보강 조적벽체의 하중-변위 곡선을 적절하게 모사하고 있다. 또한, 해석모델이 비보강 조적벽체의 파괴모드를 예측할 수 있는 것으로 나타난다.

한국(韓國) 전탑(甎塔)과 모전석탑(模甎石塔)의 관계성(關係性)에 관한 연구(硏究) (A Study about the Relations between Brick Pagodas and Stone Brick Pagodas in Korea)

  • 한욱;김지현
    • 대한건축학회논문집:계획계
    • /
    • 제35권7호
    • /
    • pp.81-88
    • /
    • 2019
  • The purpose of this study is to investigate the relations between brick and stone brick pagodas in all classes of pagoda with their construction and shape. Research objects of this study are brick and stone brick pagodas of National Treasure and Treasure and masonry pagodas that are similar to brick and stone brick pagoda. This study includes checking preceding researches, drawing questions from these preceding researches, and finding answers from these questions. The results of this study are as follows. First, pagoda of Bunhwangsa Temple, the first pagoda in the Silla Dynasty, was built as a masonry pagoda, not a stone brick pagoda. Second, roofs of stone brick pagoda barrows from brick pagoda's techniques for performance of material and ease construction. Third, brick or stone brick pagodas' base have Type II that has low and extensive foundation with soil and stones usually. Forth, Korean pagodas are categorized by their materials, construction methods, and shapes. Wooden pagodas, stone pagodas, and brick pagodas are categorized by materials, post-and lintel pagodas and masonry stone pagodas are categorized by construction methods, and pitched roof pagodas and terraced roof pagodas are categorized by shapes. Fifth, masonry pagodas of Buddhism that have shape of multi-story building were developed from Doltap, traditional stone stack, and they advanced with brick pagodas and stone pagodas to terraced roof stone pagodas and post-and lintel base brick pagodas.

증분동적해석을 통한 비보강 조적벽식 건물의 내진성능 평가 (Seismic Performance Assessment of Unreinforced Masonry Wall Buildings Using Incremental Dynamic Analysis)

  • 권기혁;김만회;김형준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권3호
    • /
    • pp.28-39
    • /
    • 2013
  • 비보강 조적벽체를 이용한 저층 건축물은 국내에 가장 흔히 볼 수 있는 주거형태이지만, 비보강 조적벽체는 높은 횡강성에 비하여 연성능력 부족 등의 이유로 지진으로부터 구조적 피해를 피하기 힘든 횡력저항시스템으로 알려져 있다. 하지만, 국내 비보강 조적벽체 전단강도와 전단강성에 대한 실험적 연구는 부족한 편이며, 실제 지진이 발생했을 비보강 조적벽체를 횡력저항요소로 사용하는 건축물의 내진성능에 대한 연구는 상대적으로 부족한 실정이다. 이로 인하여 국내 비보강 조적벽체의 특성을 반영하고 있다고 볼 수 없는 FEMA 356에서 제시하고 있는 비보강 조적벽체의 전단강도와 강성을 준용하여 사용하고 있다. 본 연구에서는 우선 FEMA 356에서 제시하고 비보강 조적벽체의 전단강도와 강성을 실험결과와의 차이에 대해 기술하고, 이 차이가 현황조사와 실험데이터를 바탕으로 결정한 표본 비보강 조적조 건축물의 내진성능에 미치는 영향과 경과년수에 따른 영향을 증분동적해석을 이용하여 계산된 붕괴여유비와 구조성능의 불확실성을 표현하는 베타값을 이용하여 분석하였다. 해석결과를 통하여 FEMA 356에 의한 전단강도와 강성을 사용할 경우 조적조 건축물의 붕괴여유비와 베타값을 과소평가하는 것으로 나타났다. 하지만, 두 경우 모두 국내 내진설계기준에서 제시하는 성능기준을 만족하지 않는 것으로 나타났으며, 경과연수가 클수록 이런 현상은 뚜렷해지며, 30년 이상 경과된 조적조 건축물은 2400년 재현주기의 지진에 붕괴확률이 약 90%에 도달하는 것으로 나타났다.

철근콘크리트 모멘트 골조시스템에서 조적 끼움벽의 내진성능 (Seismic Performance of Concrete Masonry Unit (CMU) Infills in Reinforced Concrete Moment Framing System)

  • 홍종국
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권1호
    • /
    • pp.19-26
    • /
    • 2019
  • 조적 끼움벽은 건축물의 건설에 있어서 공간을 나누고 구획하는데 사용되는 가장 흔한 시스템 중의 하나이다. 조적 끼움벽의 많은 장점에도 불구하고, 대상 시스템은 지진하중에 대하여 주의를 가지고 사용되어야 한다. 지진이 작용하는 동안 끼움벽에는 대각 방향의 압축 스트럿이 형성되면서 주변의 RC 골조에 작용하는 요구 하중을 크게 한다. 특히 개구부가 있는 조적 끼움벽의 경우, 하중 전달과정이 매우 복잡하기 때문에 시스템의 설계에 있어서 엔지니어의 주관적인 판단이 필요하게 된다. 본 연구에서는 개구부를 갖는 조적 끼움벽에 대하여 유한요소해석(FEA)를 실시하여 거동을 조사하였고, 그 결과를 현행 설계기준인 ASCE 41을 적용한 경우와 비교하였다. ASCE 41의 기준을 적용할 때, 압축 스트럿의 등가폭이 FEA를 통한 결과에 비하여 32%까지 작게 나타났다. 또한 하중저항 능력은 ASCE 41을 적용한 경우 FEA에 의한 결과에 비하여 28% 작게 나타났다. 따라서 상당한 노력이 필요한 FEA를 대신하여, 조적 끼움벽의 해석과 설계에 ASCE 41을 적용하면 약 25% 수준의 보수적이며 적절한 결과를 얻을 수다고 할 수 있다.

Updating of FE models of an instrumented G+9 RC building using measured data from strong motion and ambient vibration survey

  • Singh, J.P.;Agarwal, Pankaj;Kumar, Ashok;Thakkar, S.K.
    • Earthquakes and Structures
    • /
    • 제4권3호
    • /
    • pp.325-339
    • /
    • 2013
  • A number of structural and modal parameters are derived from the strong motion records of an instrumented G + 9 storeyed RC building during Bhuj earthquake, 26 Jan. 2001 in India. Some of the extracted parameters are peak floor accelerations, storey drift and modal characteristics. Modal parameters of the building are also compared with the values obtained from ambient vibration survey of the instrumented building after the occurrence of earthquake. These parameters are further used for calibrating the accuracy of fixed-base Finite Element (FE) models considering structural and non-structural elements. Some conclusions are drawn based on theoretical and experimental results obtained from strong motion records and time history analysis of FE models. An important outcome of the study is that strong motion peak acceleration profile in two horizontal directions is close to FE model in which masonry infill walls are modeled.