• Title/Summary/Keyword: mask consumption

Search Result 30, Processing Time 0.032 seconds

Design of VCO(Voltage Controlled Oscillator) for mobile communication with a built-in voltage regulator (전압 레귤레이터를 내장한 이동통신용 VCO(Voltage Controlled Oscillator) 설계)

  • Cho, Hyon-mook
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.76-84
    • /
    • 1997
  • In this paper, one of the core components of a mobile communication system, VCO(Voltage Controlled Oscillator) IC is designed. The VCO IC was designed, have realized as LC turned oscillator using varicap. LC sinusoidal tuned oscillator generally requires external inductors and thus remainding circuit is implemneted in monolithic IC. The circuit is fabricated using an 15 mask IC process and has a die size of 1150um${\times}$780um. The tests showed that VCO was operated at frequencies in the regions between 880MHz-915MHz in the control voltage range of 1V to 3V at 5V supply voltage and as the power supply was varied from 4.5V to 5.5V, the frequency varied 425KHz/V. The VCO IC has frequency shift of 1.97MHz/T, carrier level of -7dBm and power consumption of 16.7mA. Also it has phase noise of -80dBc/Hz, offset at 50KHz and harmonic response of center frequency is -41dBm. For the future development of the transceiver 1 chip, the previously mentioned external devices need to be incorporated into Si MMIC.

  • PDF

Validity on Submaximal Load Tests Using Cycle Ergometer in Evaluation of Maximum Oxygen Consumption Volume (최대 산소소모량 평가에 있어서 자전거 에르고미터를 이용한 최대하부하검사방법의 타당도)

  • Kang, Dongmug;Park, Yong Kyun;Lee, Yong Hwan;Sul, Jin Gon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.145-151
    • /
    • 2006
  • Because of the limitations of maximal load tests for $VO_2max$, submaximal tests using cycle ergometer are used for field study in general. This study was conducted to evaluate validity of various submaximal tests using cycle ergometer. This study had been conducted during May to June 2005, which subjects were 15 males and 15 females in twenties. Experiment was performed with restrictive conditions which regulated ambient temperature, noise, and entrance restriction. Submaximal load test protocols including YMCA Protocol (YP), ${\AA}strand$-Rhyming Protocol (ARP), Relative heart ratio Protocol (RP), and Ramp test Protocol (RP) were compared with maximal load test which used gas mask analyser using Bruce Protocol. All submaximal load tests were highly related with maximal load test (Spearman's correlation coefficient > 0.60) with statistical significancy. The highest correlation coefficient with maximal test was found in RP. Three submaximal test results except RP were significantly different with maximal test results (Wilcoxon rank test). All submaximal tests had high validity. The reason why RP had highest validity might be that it represents Korean physical strength and individual differences better than the others. RP using cycle ergometer would make easy to study for physical capacity evaluation and field workload estimation.

The Influence of $O_2$ Gas on the Etch Characteristics of FePt Thin Films in $CH_4/O_2/Ar$ gas

  • Lee, Il-Hoon;Lee, Tea-Young;Chung, Chee-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.408-408
    • /
    • 2012
  • It is well known that magnetic random access memory (MRAM) is nonvolatile memory devices using ferromagnetic materials. MRAM has the merits such as fast access time, unlimited read/write endurance and nonvolatility. Although DRAM has many advantages containing high storage density, fast access time and low power consumption, it becomes volatile when the power is turned off. Owing to the attractive advantages of MRAM, MRAM is being spotlighted as an alternative device in the future. MRAM consists of magnetic tunnel junction (MTJ) stack and complementary metal- oxide semiconductor (CMOS). MTJ stacks are composed of various magnetic materials. FePt thin films are used as a pinned layer of MTJ stack. Up to date, an inductively coupled plasma reactive ion etching (ICPRIE) method of MTJ stacks showed better results in terms of etch rate and etch profile than any other methods such as ion milling, chemical assisted ion etching (CAIE), reactive ion etching (RIE). In order to improve etch profiles without redepositon, a better etching process of MTJ stack needs to be developed by using different etch gases and etch parameters. In this research, influences of $O_2$ gas on the etching characteristics of FePt thin films were investigated. FePt thin films were etched using ICPRIE in $CH_4/O_2/Ar$ gas mix. The etch rate and the etch selectivity were investigated in various $O_2$ concentrations. The etch profiles were studied in varying etch parameters such as coil rf power, dc-bias voltage, and gas pressure. TiN was employed as a hard mask. For observation etch profiles, field emission scanning electron microscopy (FESEM) was used.

  • PDF

Design of Dual-Band WLAN Transmitter with Frequency Doubler (주파수 체배기를 이용한 이중대역 무선 송신부 설계)

  • Roh, Hee-Jung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.116-126
    • /
    • 2008
  • This paper describes the Dual-band WLAN transmitter with 2.4[GHz], 5[GHz]. Dual-band WLAN transmitter was designed at 2.4[GHz] and 5[GHz]. The Dual-band WLAN transmitter has a amplifier which operate at 2.4[GHz] and 5[GHz] frequency and two VCO(Voltage Controlled Oscillator) or VCO has a wide scope of frequency. these problem cause a size and a power consumption, The Dual-band WLAN transmitter module was proposed to solve these. the transmitter was designed to get output signals of IEEE 802.11a's 5.8[GHz] band signal using frequency multiplication way or to act a amplifier about the 2.4[GHz] band signal of IEEE 802.11b/g, according to inputed frequency and bias voltage that a eve using single transmission block. The output spectrum get the improved specification of ACPR of 4[dB], 6[dB], 16[dB] at +11[MHz], +20[MHz], +30[MHz] offset of center frequency compared to no linearization, was satisfied to transmit spectrum mask of IEEE 802.11a wireless Lan.

The influence of mothers' health beliefs and attitudes on prevention of infectious diseases on preventive health behaviors of late school-aged children (감염병 예방에 대한 어머니의 건강신념 및 태도가 학령후기 아동의 예방적 건강행위에 미치는 영향)

  • Ham, Suchang;Lee, Hanyi
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.27 no.3
    • /
    • pp.287-297
    • /
    • 2021
  • Purpose: The purpose of this study was to examine the differences in preventive health behaviors of school-age children according to their mothers' health beliefs and attitudes toward the prevention of infectious diseases. Methods: This study was conducted with 121 pairs of 4th to 6th grade elementary school children and their mothers from October 13 to October 30, 2020. The collected data were analyzed using descriptive analysis, an independent t-test, a one-way ANOVA, Sheffé's test, Pearson's correlation coefficient analysis and a multiple linear regression. Result: The mean and SD of mother's health belief in preventing infectious diseases was 3.58±0.41, the mean and SD of mother's attitude toward preventing infectious diseases was 3.39±0.38, and the mean and SD of late school-age children's preventive health behavior was 3.52±0.37. The multiple linear regression results show that the children's vaccination behavior was influenced by their mothers' perceived benefits in preventing infectious diseases. In addition, the child's vitamin C and vegetable consumption was influenced by the mother's perceived susceptibility in preventing infectious diseases, and the child's mask-wearing behavior was influenced by the mother's perceived seriousness in preventing infectious diseases. Conclusion: In order to improve the health behavior of school-aged children, programs or education are required to enhance the health beliefs and attitudes of their mothers, who were shown to affect the preventive health behavior of their children.

Influencing factors for Sleep Disturbance in the Intensive Care Unit Patients: A Systematic Review (중환자실 환자의 수면에 영향을 미치는 요인: 체계적 고찰)

  • Cho, Young Shin;Joung, Sunae
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.2
    • /
    • pp.1-14
    • /
    • 2023
  • Purpose : Sleep disturbances in patients in the intensive care unit (ICU) are related to health problems after discharge. Therefore, active prevention and management are required. Hence, identification of the factors that affect sleep in patients who are critically ill is necessary. Methods : The PubMed, Cochrane Library, CINAHL, EMBASE, and Web of Science databases were searched. Selection criteria were observational and experimental studies that assessed sleep as an outcome, included adult patients admitted to the ICU, and published between November 2015 and April 2022. Results : A total of 21,136 articles were identified through search engines and manual searches, and 42 articles were selected. From these, 22 influencing factors and 11 interventions were identified. Individual factors included disease severity, age, pain, delirium, comorbidities, alcohol consumption, sex, sleep disturbance before hospitalization, chronic obstructive pulmonary disease (COPD), cardiovascular disease, and high diastolic blood pressure (DBP), low hemoglobin (Hb), and low respiratory rate (RR). Environmental factors included light level, noise level, and temperature. Furthermore, treatment-related factors included use of sedatives, melatonin administration, sleep management guidelines, ventilator application, nursing treatment, and length of ICU stay. Regarding sleep interventions, massage, eye mask and earplugs, quiet time and multicomponent protocols, aromatherapy, acupressure, sounds of the sea, adaptive intervention, circulation lighting, and single occupation in a room were identified. Conclusion : Based on these results, we propose the development and application of various interventions to improve sleep quality in patients who are critically ill.

The Correlation between HRCT Emphysema Score and Exercise Pulmonary Testing Parameters (HRCT Emphysema Scoring과 운동부하 폐기능검사 지표들 간의 상관관계)

  • Choi, Eun-Kyoung;Choi, Young-Hee;Kim, Doh-Hyung;Kim, Yong-Ho;Yoon, Se-Young;Park, Jae-Seuk;Kim, Keun-Youl;Lee, Kye-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.415-425
    • /
    • 2001
  • Background : The correlation between the high resolution computed tomography(HRCT) emphysema score and the physiologic parameters including resting and exercise pulmonary function test was investigated in 14 patients($60.6{\pm}10.3$ years) with pulmonary emphysema. Methods : The patients underwent a HRCT, a resting pulmonary function test, and incremental exercise testing(cycle ergometer, 10 W/min). Computed tomography scans were obtained on a GE highlight at 10 mm intervals using 10 mm collimation, from the apex to the base after a full inspiration. The emphysema scores were determined by a CT program 'Density mask' outlining the areas with attenuation values less than -900 HU, indicating the emphysema areas, and providing an overall percentage of lung involvement by emphysema. Results : Among the resting PFT parameters, only the diffusing capacity(r=-0.75) and $PaO_2$ (r=-0.66) correlated with the emphysema score(p<0.05). Among the exercise test parameters, the emphysema score correlated significantly with the maximum power(r=-0.74), maximum oxygen consumption(r=-0.68), anaerobic threshold(V-slope method: r=-0.69), maximal $O_2$-pulse(r=-0.73), and the physiologic dead space ratio at the maximum workload(r=-0.80)(p<0.01). Conclusion: We could find that exercise testing parameters showed a much better correlation with the HRCT emphysema score, which is known to have a good correlation with the pathologic severity than the resting PIT parameters. Therefore it is suggested that exercise testing is superior to resting PIT for estimating in the estimation of the physiologic disturbance in emphysema patients.

  • PDF

Design of Bias Circuit for Measuring the Multi-channel ISFET (다채널 ISFET 측정용 단일 바이어스 회로의 설계)

  • Cho, Byung-Woog;Kim, Young-Jin;Kim, Chang-Soo;Choi, Pyung;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.31-38
    • /
    • 1998
  • Multi-channel sensors can be used to increase the reliability and remove the random iloise in ion-sensitive field effect transistors(ISFETs). Multi-channel sensors is also an essential step toward potential fabrication of sensors for several ionic species in one device. However, when the multi-channel sensors are separately biased, the biasing problems become difficult, that is to say, the bias circuit is needed as many sensors. In this work, a circuit for biasing the four pH-ISFETs in null-balance method, where bias voltages are switched, was proposed. The proposed concept is need only one bias circuit for the four sensors. Therefore it has advantages of smaller size and lower power consumption than the case that all sensors are separately biased at a time. The proposed circuit was tested with discrete devices and its performance was investigated. In the recent trend, sensor systems are implemented as portable systems. So the verified measurement circuit was integrated by using the CMOS circuit. Fortunately, ISFET fabrication process can be compatible with CMOS process. Full circuit has a mask area of $660{\mu}m{\times}500{\mu}m$. In the future, this step will be used for developing the smart sensor system with ISFET.

  • PDF

Cohort Observation of Blood Lead Concentration of Storage Battery Workers (축전지공장 근로자들의 혈중 연농도에 대한 코호트 관찰)

  • Kim, Chang-Yoon;Kim, Jung-Man;Han, Gu-Wung;Park, Jung-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.23 no.3 s.31
    • /
    • pp.324-337
    • /
    • 1990
  • To assess the effectiveness of the interventions in working environment and personal hygiene for the occupational exposure to the lead, 156 workers (116 exposed subjects and 40 controls) of a newly established battery factory were examined for their blood lead concentration (Pb-B) in every 3 months up to 18 months. Air lead concentration (Pb-A) of the workplaces was also checked for 3 times in 6 months interval from August 1987. Environmental intervention included the local exhaust ventilation and vacuum cleaning of the floor. Intervention of the personal hygiene included the daily change of clothes, compulsory shower after work and hand washing before meal, prohibition of cigarette smoking and food consumption at the work site and wearing mask. Mean Pb-B of the controls was $21.97{\pm}3.36{\mu}g/dl$ at the preemployment examination and slightly increased to $22.75{\pm}3.38{\mu}g/dl$ after 6 months. Mean Pb-B of the workers who were employed before the factory was in operation (Group A) was $20.49{\pm}3.84{\mu}g/dl$ on employment and it was increased to $23.90{\pm}5.30{\mu}g/dl$ after 3 months (p<0.01). Pb-B was increased to $28.84{\pm}5.76{\mu}g/dl$ 6 months after the employment which was 1 month after the initiation of intervention program. It did not increase thereafter and ranged between $26.83{\mu}g/dl\;and\;28.28{\mu}g/dl$ in the subsequent 4 tests. Mean Pb-B of the workers who were employed after the factory had been in operation but before the intervention program was initiated (Group B) was $16.58{\pm}4/53{\mu}g/dl$ before the exposure and it was increased to $28.82{\pm}5.66{\mu}g/dl$(P<0.01) in 3 months later (1 month after the intervention). The values of subsequent 4 tests remained between 26.46 and $28.54{\mu}g/dl$. Mean Pb-B of the workers who were employed after intervention program had been started (Group C) was $19.45{\pm}3.44{\mu}g/dl$ at the preemployment examination and gradually increased to $22.70{\pm}4.55{\mu}g/dl$ after 3 months(P<0.01), $23.68{\pm}4.18{\mu}g/dl$ after 6 months, and $24.42{\pm}3.60{\mu}g/dl$ after 9 months. Work stations were classified into 4 parts according to Pb-A. The Pb-A of part I, the highest areas, were $0.365mg/m^3$, and after the intervention the levels were decreased to $0.216mg/m^3\;and\;0.208mg/m^3$ in follow-up tests. The Pb-A of part II was decreased from $0.232mg/m^3\;to\;0.148mg/m^3,\;and\;0.120mg/m^3$ after the intervention. Pb-A of part III and W was tested only after intervention and the Pb-A of part III were $0.124mg/m^3$ in Jannuary 1988 and $0.081mg/m^3$ in August 1988. The Pb-A of part IV not stationed at one place but moving around, was $0.110mg/m^3$ in August 1988. There was no consistent relationship between Pb-B and Pb-A. Pb-B of the group A and B workers in the part of the highest Pb-A were lower than those of the workers in the parts of lower Pb-A. Pb-B of the workers in the part of the lowest Pb-A incerased more rapidly. Pb-B of group C workers was the highest in part I and the lowest in part IV. These findings suggest that Pb-B is more valid method than Pb-A for monitoring the health of lead workers and intervention in personal hygiene is more effective than environmental intervention.

  • PDF

A cohort study on blood zinc protoporphyrin concentration of workers in storage battery factory (축전지 공장 근로자들의 혈중 Zinc Protoporphyrin에 대한 코호트 연구)

  • Jeon, Man-Joong;Lee, Joong-Jeong;SaKong, Joon;Kim, Chang-Yoon;Kim, Jung-Man;Chung, Jong-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.1 s.60
    • /
    • pp.112-126
    • /
    • 1998
  • To investigate the effectiveness of the interventions in working environment and personal hygiene for the occupational exposure to the lead, the blood zinc protoporphyrin (ZPP) concentrations of 131 workers (100 exposed subjects and 31 controls) of a newly established battery factory were analyzed. They were measured in every 3 months up to 18 months. Ai. lead concentration (Pb-A) of the workplaces was also checked for 3 times in 6 months interval from August 1987. Environmental intervention included the local exhaust ventilation and vacuum cleaning of the floor. Intervention of the personal hygiene included the daily change of clothes, compulsory shower after work and hand washing before meal, prohibition of cigarette smoking and food consumption at the work site and wearing mask. Mean blood ZPP concentration of the controls was $16.45{\pm}4.83{\mu}g/d\ell$ at the preemployment examination and slightly increased to $17.77{\pm}5.59{\mu}g/d\ell$ after 6 months. Mean blood ZPP concentration of the exposed subjects who were employed before the factory was in operation (Group A) was $17.36{\pm}5.20{\mu}g/d\ell$ on employment and it was increased to $23.00{\pm}13.06{\mu}g/d\ell$ after 3 months. The blood ZPP concentration was increased to $27.25{\pm}6.40{\mu}g/d\ell$ on 6 months (p<0.01) after the employment which was 1 month after the initiation of intervention program. It did not increase thereafter and ranged between $25.48{\mu}g/d\ell$ and $26.61{\mu}g/d\ell$ in the subsequent 4 results. Mean blood ZPP concentration of the exposed subjects who were employed after the factory had been in operation but before the intervention program was initiated (Group B) was $14.34{\pm}6.10{\mu}g/d\ell$ on employment and it was increased to $28.97{\pm}7.14{\mu}g/d\ell$ (p<0.01) in 3 months later(1 month after the intervention). The values of subsequent 4 tests were maintained between $26.96{\mu}g/d\ell$and $27.96{\mu}g/d\ell$. Mean blood ZPP concentration of the exposed subjects who were employed after intervention program had been started (Group C) was$21.34{\pm}5.25{\mu}g/d\ell$ on employment and it was gradually increased to $23.37{\pm}3.86{\mu}g/d\ell$ (p<0.01) after 3 months, $23.93{\pm}3.64{\mu}g/d\ell$ after 6 months, $25.50{\pm}3.01{\mu}g/d\ell$ after 9 months, and $25.50{\pm}3.10{\mu}g/d\ell$ after 12 months. Workplaces were classified into 4 parts according to Pb-A. The Pb-A of part I, the highest areas, were $0.365mg/m^3$, and after the intervention the levels were decreased to $0.216mg/m^3$ and$0.208mg/m^3$ in follow-up test. The Pb-A of part II which was resulted in lowe. value than part I was decreased from $0.232mg/m^3$ to $0.148mg/m^3$, and $0.120mg/m^3$ after the intervention. The Pb-A of part III was tested after the intervention and resulted in $0.124mg/m^3$ in January 1988 and $0.181mg/m^3$ in August 1988. The Pb-A of part IV was also tested after the intervention and resulted in $0.110mg/m^3$ in August 1988. There was no consistent relationship between Pb-A and blood ZPP concentration. The blood ZPP concentration of the group A and B workers in the part of the highest Pb-A were lower than those of the workers in the parts of lower Pb-A. The blood ZPP concentration of the workers in the part of the lowest Pb-A increased more rapidly. The blood ZPP concentration of the group C workers was the highest in part III. These findings suggest that the intervention in personal hygiene is more effective than environmental intervention, and it should be carried out from the first day of employment and to both the exposed subjects, blue color workers and the controls, white color workers.

  • PDF