• 제목/요약/키워드: marginal accuracy

검색결과 96건 처리시간 0.026초

침식연소를 고려한 고체로켓의 비정상 내탄도 해석 기법 (Unsteady Internal Ballistic Analysis for Solid Rocket Motors with Erosive Burning)

  • 조민경;허준영;성홍계
    • 한국추진공학회지
    • /
    • 제13권2호
    • /
    • pp.17-25
    • /
    • 2009
  • 본 연구에서는 연소실의 축방향 압력과 속도변화를 고려한 비정상 내탄도 해석모델을 제안하고 이를 바탕으로 침식연소에 미치는 인자를 해석하였다. 개발 모델의 검증을 위하여 침식연소가 없는 경우와 침식연소가 있는 경우에 대하여 선행연구 결과와 비교하였으며 해석결과가 일치함을 확인하였다. 연소실 압력, 그레인 길이, 그레인 초기온도, 추진제 기화온도가 침식연소에 미치는 영향을 조사하였다.

Linear prediction and z-transform based CDF-mapping simulation algorithm of multivariate non-Gaussian fluctuating wind pressure

  • Jiang, Lei;Li, Chunxiang;Li, Jinhua
    • Wind and Structures
    • /
    • 제31권6호
    • /
    • pp.549-560
    • /
    • 2020
  • Methods for stochastic simulation of non-Gaussian wind pressure have increasingly addressed the efficiency and accuracy contents to offer an accurate description of the extreme value estimation of the long-span and high-rise structures. This paper presents a linear prediction and z-transform (LPZ) based Cumulative distribution function (CDF) mapping algorithm for the simulation of multivariate non-Gaussian fluctuating wind pressure. The new algorithm generates realizations of non-Gaussian with prescribed marginal probability distribution function (PDF) and prescribed spectral density function (PSD). The inverse linear prediction and z-transform function (ILPZ) is deduced. LPZ is improved and applied to non-Gaussian wind pressure simulation for the first time. The new algorithm is demonstrated to be efficient, flexible, and more accurate in comparison with the FFT-based method and Hermite polynomial model method in two examples for transverse softening and longitudinal hardening non-Gaussian wind pressures.

C-Arm 유도하의 안면골 골절의 정복술 (C-Arm Fluoroscopy for Accurate Reduction of Facial Bone Fracture)

  • 황소민;김장혁;김형도;정용휘;김홍일
    • 대한두개안면성형외과학회지
    • /
    • 제14권2호
    • /
    • pp.96-101
    • /
    • 2013
  • Background: Among facial fractures, nasal bone fracture, zygomatic arch fracture and mandibular subcondyle fracture take a large portion. Among surgical operations for nasal bone fracture, zygomatic arch fracture and mandibular subcondyle fracture, closed reduction has been generally used but, unlike open reduction, there is a problem in evaluating its accuracy of reduction. Methods: An assessment was made from October 2011 until April 2013 prospectively on 37 patients. For all the operations, closed reductions were executed in a conventional way and simultaneously using C-Arm to verify the reduction of fractures. Two images of plain radiography, one taken before operation and another one taken one day after the operation, were compared. After obtaining images of plain radiography using C-Arm immediately after the correction upon operation, they were compared with the images of plain radiography taken one day after the operation. Results: The fracture reductions of 26 patients among 27 nasal fracture patients were satisfactory but one patient showed a marginal overcorrection of less than 1 mm. The fracture reductions of 7 patients among 8 zygomatic arch fracture patients were satisfactory but one patient showed a marginal undercorrection of less than 2 mm. All of two mandibular subcondyle fracture patients showed less than 2 mm undercorrection. Conclusion: Closed reduction guided by C-Arm for nasal bone fracture, zygomatic arch fracture and mandibular subcondyle fracture was clinically useful because it could make a real-time assessment on fractured areas and add immediate corrections during the operation.

EFFECTS OF ATMOSPHERIC WATER AND SURFACE WIND ON PASSIVE MICROWAVE RETRIEVALS OF SEA ICE CONCENTRATION: A SIMULATION STUDY

  • Shin, Dong-Bin;Chiu, Long S.;Clemente-Colon, Pablo
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.892-895
    • /
    • 2006
  • The atmospheric effects on the retrieval of sea ice concentration from passive microwave sensors are examined using simulated data typical for the Arctic summer. The simulation includes atmospheric contributions of cloud liquid water and water vapor and surface wind on surface emissivity on the microwave signatures. A plane parallel radiative transfer model is used to compute brightness temperatures at SSM/I frequencies over surfaces that contain open water, first-year (FY) ice and multi-year (MY) ice and their combinations. Synthetic retrievals in this study use the NASA Team (NT) algorithm for the estimation of sea ice concentrations. This study shows that if the satellite sensor’s field of view is filled with only FY ice the retrieval is not much affected by the atmospheric conditions due to the high contrast between emission signals from FY ice surface and the signals from the atmosphere. Pure MY ice concentration is generally underestimated due to the low MY ice surface emissivity that results in the enhancement of emission signals from the atmospheric parameters. Simulation results in marginal ice areas also show that the atmospheric and surface effects tend to degrade the accuracy at low sea ice concentration. FY ice concentration is overestimated and MY ice concentration is underestimated in the presence of atmospheric water and surface wind at low ice concentration. In particular, our results suggest that strong surface wind is more important than atmospheric water in contributing to the retrieval errors of total ice concentrations over marginal ice zones.

  • PDF

Verification of a computer-aided replica technique for evaluating prosthesis adaptation using statistical agreement analysis

  • Mai, Hang-Nga;Lee, Kyeong Eun;Lee, Kyu-Bok;Jeong, Seung-Mi;Lee, Seok-Jae;Lee, Cheong-Hee;An, Seo-Young;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권5호
    • /
    • pp.358-363
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the reliability of computer-aided replica technique (CART) by calculating its agreement with the replica technique (RT), using statistical agreement analysis. MATERIALS AND METHODS. A prepared metal die and a metal crown were fabricated. The gap between the restoration and abutment was replicated using silicone indicator paste (n = 25). Gap measurements differed in the control (RT) and experimental (CART) groups. In the RT group, the silicone replica was manually sectioned, and the marginal and occlusal gaps were measured using a microscope. In the CART group, the gap was digitized using optical scanning and image superimposition, and the gaps were measured using a software program. The agreement between the measurement techniques was evaluated by using the 95% Bland-Altman limits of agreement and concordance correlation coefficients (CCC). The least acceptable CCC was 0.90. RESULTS. The RT and CART groups showed linear association, with a strong positive correlation in gap measurements, but without significant differences. The 95% limits of agreement between the paired gap measurements were 3.84% and 7.08% of the mean. The lower 95% confidence limits of CCC were 0.9676 and 0.9188 for the marginal and occlusal gap measurements, respectively, and the values were greater than the allowed limit. CONCLUSION. The CART is a reliable digital approach for evaluating the fit accuracy of fixed dental prostheses.

인상채득방법과 방향에 따른 인상체의 정밀성과 체적 안정성에 관한 연구 (A STUDY ON ACCURACY AND DIMENSIONAL STABILITY ACCORDING TO IMPRESS10N METHODS)

  • 이재영;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제37권5호
    • /
    • pp.567-580
    • /
    • 1999
  • Accurate reproduction of intraoral tissue is essential in the fabrication of fixed prosthesis. This selection of impression material and method is very important. In this study, vinyl polysiloxane type impression material $Panasil^{(R)}$ was used. Three impression methods ; one-step technique, individual tray technique, and individual tooth tray technique using the vinyl polysiloxane type bite registration material $Futar^{(R)}$ Occlusion, were used to take horizontal and vertical impression. Improved stone models were fabricated. The amount of occlusal surface discrepaneies, interabutment distance discrepancies, amount of marginal defect were evaluated with the $X-PLAN360d^{(R)}$ and photoscanning. The results were as follows. 1. There was no significant difference in occlusal surface according to the directions and techniques of impression taking. 2. There was no significant difference in interabutment distance discrepancies according to the directions and techniques of impression taking 3. There was no significant difference in marginal discrepancies according to the direction of impression taking but there was significant difference between one-step technique and individual tray technique, individual tooth tray technique (P<0.05). Taken together, these results suggest that individual tray technique and individual tooth tray technique are more accurate for impression taking than one-step technique.

  • PDF

Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections

  • Siadat, Hakimeh;Beyabanaki, Elaheh;Mousavi, Niloufar;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.271-277
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to evaluate the effect of implant connection design (external vs. internal) on the fit discrepancy and torque loss of zirconia and titanium abutments. MATERIALS AND METHODS. Two regular platform dental implants, one with external connection ($Br{\aa}nemark$, Nobel Biocare AB) and the other with internal connection (Noble Replace, Nobel Biocare AB), were selected. Seven titanium and seven customized zirconia abutments were used for each connection design. Measurements of geometry, marginal discrepancy, and rotational freedom were done using video measuring machine. To measure the torque loss, each abutment was torqued to 35 Ncm and then opened by means of a digital torque wrench. Data were analyzed with two-way ANOVA and t-test at ${\alpha}=0.05$ of significance. RESULTS. There were significant differences in the geometrical measurements and rotational freedom between abutments of two connection groups (P<.001). Also, the results showed significant differences between titanium abutments of internal and external connection implants in terms of rotational freedom (P<.001). Not only customized internal abutments but also customized external abutments did not have the exact geometry of prefabricated abutments (P<.001). However, neither connection type (P=.15) nor abutment material (P=.38) affected torque loss. CONCLUSION. Abutments with internal connection showed less rotational freedom. However, better marginal fit was observed in externally connected abutments. Also, customized abutments with either connection could not duplicate the exact geometry of their corresponding prefabricated abutment. However, neither abutment connection nor material affected torque loss values.

Evaluation of different approaches for using a laser scanner in digitization of dental impressions

  • Lee, Wan-Sun;Kim, Woong-Chul;Kim, Hae-Young;Kim, Wook-Tae;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.22-29
    • /
    • 2014
  • PURPOSE. This study aimed to investigate the potential clinical application of digitized silicone rubber impressions by comparing the accuracy of zirconia 3-unit fixed partial dentures (FPDs) fabricated from 2 types of data (working model and impression) obtained from a laser scanner. MATERIALS AND METHODS. Ten working models and impressions were prepared with epoxy resin and vinyl polysiloxane, respectively. Based on the data obtained from the laser scanner (D-700; 3Shape A/S, Copenhagen, Denmark), a total of 20 zirconia frameworks were prepared using a dental CAD/CAM system (DentalDesigner; 3shape A/S, Copenhagen, Denmark / Ener-mill, Dentaim, Seoul, Korea). The silicone replicas were sectioned into four pieces to evaluate the framework fit. The replicas were imaged using a digital microscope, and the fit of the reference points (P1, P2, P3, P4, P5, P6, and P7) were measured using the program in the device. Measured discrepancies were divided into 5 categories of gaps (MG, CG, AWG, AOTG, OG). Data were analyzed with Student's t-test ($\alpha$=0.05), repeated measures ANOVA and two-way ANOVA (${\alpha}=0.05$). RESULTS. The mean gap of the zirconia framework prepared from the working models presented a narrower discrepancy than the frameworks fabricated from the impression bodies. The mean of the total gap in premolars (P=.003) and molars (P=.002) exhibited a statistical difference between two groups. CONCLUSION. The mean gap dimensions of each category showed statistically significant difference. Nonetheless, the digitized impression bodies obtained with a laser scanner were applicable to clinical settings, considering the clinically acceptable marginal fit ($120{\mu}m$).

한국 주변해역 30초 격자수심 - KorBathy30s (Digital 30sec Gridded Bathymetric Data of Korea Marginal Seas - KorBathy30s)

  • 서승남
    • 한국해안·해양공학회논문집
    • /
    • 제20권1호
    • /
    • pp.110-120
    • /
    • 2008
  • 한국 주변해역$(30^{\circ}N{\sim}44^{\circ}N,\;117^{\circ}E{\sim}143^{\circ}E)$에 대한 30초 간격의 격자수심을 산출하였다 자료 생산을 위해 공개된 1분 수심 최신자료와 2007년 간행된 국립해양조사원의 모든 수치해도를 이용하였다. 격자수심의 기준면은 약 최저저조면이며 경위도는 WGS84 좌표계를 사용하였다. 특히 수치해도에서 측심자료를 추출하고 이를 WGS84 좌표로 변환하는 프로그램을 개발하여 자료의 정확성을 꾀하였고 보간법을 이용한 산출된 자료를 기존 자료와 비교 분석하였다. 본 수심자료에서는 기존 격자수심과 달리 보다 상세하고 정확한 지형을 볼 수 있다.

CAD/CAM으로 제작된 지르코니아 코어의 지대치 형태에 따른 변연 및 내면 적합도에 관한 연구 (Marginal and internal fit according to the shape of the abutment of a zirconia core manufactured by computer-aided design/computer-aided manufacturing)

  • 김지수;류재경
    • 대한치위생과학회지
    • /
    • 제5권1호
    • /
    • pp.13-19
    • /
    • 2022
  • Background: In this study, zirconia copings were fabricated by setting clinically acceptable inner values for prostheses using computer-aided design/computer-aided manufacturing (CAD/CAM). The processed copings were evaluated for the marginal and internal fit of each abutment shape with a CAD program using the silicone replica technique. Methods A total of 20 copings was produced by selecting models commonly used in clinical practice. After injecting the sample, the minimum thickness, internal adhesion interval, and distance to the margin line were set to 0.5, 0.05, and 1.00 mm using a dental CAD program, respectively. It was measured using a 2D section function in a three-way program of the silicon replication technology. Although the positions and number of measurements of the anterior and posterior regions differed, nine parts of each pre-tube were designated and measured by referring to a previous study to compare the two samples. Results As a result, the average margin of the mesial, distal, and buccal (labial) surfaces was 59.90 ㎛ in the anterior region and 60.40 ㎛ in the posterior region. The mean axial wall margin was 67.25 ㎛ in the anterior region and 69.25 ㎛ in the posterior region. In occlusion, the anterior teeth (77.70 ㎛), posterior teeth (77.60 ㎛), and both anterior and posterior regions were within the clinically acceptable range. Conclusion The edge and inner fit of zirconia coping manufactured using the CAD/CAM system showed clinically applicable results. To reduce errors and increase accuracy, materials and machine errors that affect the manufacture of prosthetics should be investigated. Based on our results, the completeness of prosthetics could increase if the inner value and characteristics of the material are adjusted when applied in clinical practice.