• Title/Summary/Keyword: manufacturers

Search Result 6,769, Processing Time 0.03 seconds

The study of Breast Specific Gamma Imaging Protocol using Self-development Phantom (자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰)

  • Lee, Hae-Jung;Lee, Juyoung;Lim, Kuen-Kyo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.39-47
    • /
    • 2014
  • Purpose As breast cancer patients continue to increase every year, cases of BSGI are on the rise with a heavier reliance on it. However, BSGI protocol in hospitals was not studied enough despite it was covered by hospital's condition and recommendation of manufacturers. The objective of the study was an examination of methods to be applicable to BSGI protocols, putting the self-development phantom to use in quality assessment of the images. Materials and Methods Dilon 6800 (Dilon Technologies Inc, Newport News, USA) was used in the study and five different sizes of sphere were distinctively produced in the phantom. The study used $^{99m}TcO_4$. The cases were classified in to three categories that background radioactivity to region of interest as ratio of 2: 4: 8, They were acquired images for 5, 7, 10mins. The acquired image was set region of interest according to the size of sphere, and We analyzed quantitative and qualitative analysis. The acquired data statistically analyzed with SPSS ver.18.0. Results As the result of quantitative and qualitative analysis, count rate of each sphere in accordance with difference of injection dose showed that higher count rate as injection dose and sphere size increased (P<0.005). Count rate of each sphere in accordance with difference of acquisition time showed that higher count rate as acquisition time and sphere size increased (P<0.005). Contrast noise ratio of each sphere in accordance with difference of injection dose showed that higher contrast noise ratio as injection dose increased. Particularly, Contrast noise ratio of eight times ratio images was the highest among. Contrast noise ratio of each sphere in accordance with difference of acquisition time showed that higher contrast noise ratio as acquisition time increased. And, Contrast noise ratio of seven minute image was the highest among (P<0.005). Conclusion There was significant change of Contrast noise ratio through quantitative and qualitative analysis. Moreover, We found usefulness of phantom. If Institutions identified image through the phantom study and they made BSGI protocol, We expected to help the improvement of diagnostic value of the images.

  • PDF

Studies on the Usage of Compound Flavorings in Korea (국내의 조합향료 사용실태 조사)

  • Kim, Hee-Yun;Yoon, Hae-Jung;Hong, Ki-Hyoung;Park, Sung-Kwan;Choi, Jang-Duck;Choi, Woo-Jeong;Kim, Ji-Hye;Park, Hui-Og;Jin, Myeong-Sig;Lee, Chul-Won
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.8
    • /
    • pp.1407-1413
    • /
    • 2004
  • This study was performed to investigate the usage and management of flavorings inside or outside (Europe, Japan, JECFA and USA) for that establish a legislation about the flavoring management in Korea. Also, this study contributed to prevent confusion when manufacturers produce flavorings used in food industry. 6,434 among 8,386 flavorings authorized by Korea Food and Drug administration are compound flavorings, and 618 among 6,434 compound flavorings are synthetic flavorings. Many other substances except for flavorings are using as solvent in flavoring manufacture. Flavorings used in food industries of Korea are listed at least one among FEMA, JECFA, CoE and JFFMA except for isooctyl acetate and tricyclene. 493 items out of total 618 synthetic flavorings have completed safety evaluation by JECFA. 106 synthetic flavorings out of the rest listed FEMA as GRAS and 20 synthetic flavorings used in Japan. The replier answered that the most frequently used flavorings are strawberry, grape, orange, plum, lemon and vanilla flavor and that the usage of flavoring added to foodstuffs is less than 0.5%.

A Study on the Development of Aerobic Exercise Equipment Design for User-Centered -Focusing on Elliptical Cross Trainer- (사용자 중심의 유산소 운동기구 디자인 개발에 관한 연구 -Elliptical Cross Trainer를 중심으로-)

  • Chung, Kyung-Ryul;Song, Bok-Hee;Yoon, Se-Kyun;Park, Il-Woo
    • Archives of design research
    • /
    • v.19 no.5 s.67
    • /
    • pp.129-138
    • /
    • 2006
  • It is expected that the typical lifestyle of the future will be transformed into an opulent and comfortable existence as the quality of life improves due to the increase in household income and reduction in working hours. In the meantime, as the standard of living becomes increasingly more comfortable and plentiful, the toll on physical health becomes magnified as a result of obesity and insufficient exercise caused by super nutrition and change in labor conditions (from physical labor to mental labor). This has instigated a deep awareness in fitness on the part of many people, forcing them to recognize the significance of daily exercise and physical activity. The high annual growth rate in the fitness and athletic apparatus market, which is more than 20%, is attributed to this phenomenon. The Elliptical Cross Trainer(ECT), which has drawn wide attention recently, is a non-impact athletic apparatus that not only promotes exercise of the upper body parts in such sports as skiing but also the exercise of lower parts of the body on a treadmill. It is a type of cross training athletic gear that has been developed for aerobic exercise throughout the entire body. It has already formed a market as big as that of the treadmill in Europe, America, etc. Recently, its demand is growing sharply in the Korean markets as well as those in Northeast Asian countries, Despite such demand increase and expansion, since most of the expensive ECTs are exclusively supplied by suppliers in only a few advanced countries, localization of the ECT is urgently required in order to enhance competitiveness of Korean manufacturers and to expand the market. This paper introduces the process and results of a design-engineering cooperative study that was peformed for the development of the ECT.

  • PDF

A Study on Air Resistance and Greenhouse Gas Emissions of an Ocean Leisure Planning Boat (해양레저용 활주형선의 공기저항 및 온실 가스 배출에 대한 연구)

  • Kim, Y.S.;Hwang, S.K.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.3
    • /
    • pp.202-210
    • /
    • 2013
  • As incomes increase, interest in ocean leisure picks up. As a result, a lot of research and developments on hull form design and production of planing boats, mostly used for ocean leisure, are needed. Analysis in researches on resistance of planing boats shows that resistance characteristic of planing boats is different from resistance characteristic of general boats because the former is fast, and its wetted surface is very small. Using Savitsky formula widely used in the calculation of effective horse power in shipbuildingyards, and propulsion system and engine manufacturers, this study calculated total resistance of a research planing boat. Then it analyzed the flow characteristics of the planing boat through theoretical analysis and wind tunnel experiment, and computed air resistance and lift force by changes of speed and trim angle. It also compared and analyzed result of theoretical analysis and experiment of the ratio of air resistance to total resistance under variations of velocity and trim angle. When the study is used to estimate more accurate effective horse power, it is expected to remedy abuses of unnecessarily installing high-powered engine. As nature disasters due to abnormal changes of weather increase, interest in greenhouse gas grows. International Maritime Organization (IMO) legislated Energy Efficiency Design Index (EEDI) and Energy Efficiency Operational Indicator (EEOI) to reduce ship greenhouse gas emissions. But this index will be applied to over 400 tons ships, small ships, emitting more greenhouse gases than larege ships per unit power, will dodge the regulations. Thus, this study indicated a problem by calculating greenhouse gas emissions of an ocean leisure planning boat (a small ship), and suggested the need for EEDI of small ships.

Evaluation of the Usefulness of the Self-developed Kw-infrared Reflective Marker in Non-coplanar Treatment (비동일면 치료 시 자체 제작한 Kw-infrared Reflective Marker의 유용성 평가)

  • Kwon, Dong-Yeol;Ahn, Jong-Ho;Park, Young-Hwan;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: In radiotherapy that takes into account respiration using a RPM (Real time Position Management, Varian, USA) system, which can treat in consideration of the movement of tumor, infrared reflective markers supplied by manufacturers cannot obtain respiratory signal if the couch rotates at a certain angle or larger. In order to solve this problem, the author developed the 3D infrared reflective marker named 'Kw-marker' that can obtain respiratory signal at any angle, and evaluate its usefulness. Materials and Methods: In order to measure the stability of respiratory signal, we put the infrared reflective marker on the 3D moving phantom that can reproduce respiratory movement and acquired respiratory signal for 3 minutes under each of 3 conditions (A: $couch\;0^{\circ}$, a manufacturer's infrared reflective marker B: $couch\;0^{\circ}$, Kw-marker C: $couch\;90^{\circ}$, Kw-marker). By analyzing the respiratory signal using a breath analysis program (Labview Ver. 7.0), we obtained the peak value, valley value, standard deviation, variation value, and amplitude value. In order to examine the rotation error and moving range of the target, we placed a B.B phantom on the 3D moving phantom, and obtained images at a couch angle of $0^{\circ}$ and $90^{\circ}$ using OBI, and then acquired the X, Y and Z values (mm) of the ball bearing at the center of the B.B phantom. Results: According to the results of analyzing the respiratory signal, the standard deviation at the peak value was A: 0.002, B: 0.002 and C: 0.003, and the stability of respiration for amplitude was A: 0.15%, B: 0.14% and C:0.13%, showing that we could get respiratory signal stably by using the Kw-marker. When the couch rotated $couch\;90^{\circ}$, the mean rotation error of the ball bearing, namely, the target was X: -1.25 mm, Y: -0.45 mm and Z: +0.1 mm, which were within 1.3 mm on the average in all directions, and the difference in the moving range of the target was within 0.3 mm. Conclusion: When we obtained respiratory signal using the Kw-marker in non-coplanar treatment where the couch rotated, we could acquire respiratory signal stably and the Kw-marker was effective enough to substitute for the manufacturer's infrared reflective marker. When the rotation error and moving range of the target were measured, there was little difference, indicating that the displacement of the reflector movement in couch rotation is the cause of change in the scale and amplitude of respiratory signal. If the converted value of amplitude height according to couch angle is studied further and applied, it may be possible to perform non-coplanar phase-based gating treatment.

  • PDF

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

Physicochemical Properties of Commercial Sweet Potato Starches (시판 고구마전분의 이화학적 특성)

  • Baek, Man-Hee;Cha, Dong-Su;Park, Hyun-Jin;Lim, Seung-Taik
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.755-762
    • /
    • 2000
  • Physicochemical properties of commercial sweet potato starches manufactured by 7 different companies were investigated in comparison with corn and potato starches. Crude ash and protein content varied from 0.36 to 1.02%, and from 0.04 to 0.14% based on dry weight, respectively. The protein contents were relatively smaller than that of corn or potato starch. But whiteness of the sweet potato starches was less than that of corn or potato starch. Mean diameter of the sweet potato starch granules varied from 14.23 to $21.08\;{\mu}m$ depending on the company and all sweet potato starches showed bimodal size distributions. Pasting viscosity measured by Rapid Viscoanalyzer(RVA) also showed variations among the starches of different companies. The starch from D company in Korea had the lowest pasting temperature$(74.00^{\circ}C)$ whereas the starch from a phillippine company(P) did the highest one$(80.35^{\circ}C)$. The peak viscosity of sweet potato starches was higher than that of corn starch but lower than that of potato starch. The D company starch also showed the highest peak viscosity(2283 cp) among the starches tested. Paste breakdown by hot shearing ranged from 524 cp (S company) to 1279 cp (HL company). Textural properties of the starch gels appeared significantly different among the starches of different manufacturers. The greatest hardness of the gel was $137.90\;g_{f}$ at 1 day storage whereas the lowest value was $31.53\;g_{f}$. Except the starches from 2 companies (P and S), the sweet potato starches formed very soft and weak gels. P or S company starches formed the gels similar to potato starch. Syneresis by freeze-thawing treatments appeared less for sweet potato starch gels than that for corn starch gels, but greater than that for potato starch gel. The overall properties of the sweet potato starches varied by the manufacturing companies, and ranged between those of corn and potato starches.

  • PDF

정지궤도 통신해양기상위성의 기상분야 요구사항에 관하여

  • Ahn, Myung-Hwan;Kim, Kum-Lan
    • Atmosphere
    • /
    • v.12 no.4
    • /
    • pp.20-42
    • /
    • 2002
  • Based on the "Mid to Long Term Plan for Space Development", a project to launch COMeS (Communication, Oceanography, and Meteorological Satellite) into the geostationary orbit is undergoing. Accordingly, KMA (Korea Meteorological Administration) has defined the meteorological missions and prepared the user requirements to fulfill the missions. To make a realistic user requirements, we prepared a first draft based on the ideal meteorological products derivable from a geostationary platform and sent the RFI (request for information) to the sensor manufacturers. Based on the responses to the RFI and other considerations, we revised the user requirement to be a realistic plan for the 2008 launch of the satellite. This manuscript introduces the revised user requirements briefly. The major mission defined in the revised user requirement is the augmentation of the detection and prediction ability of the severe weather phenomena, especially around the Korean Peninsula. The required payload is an enhanced Imager, which includes the major observation channels of the current geostationary sounder. To derive the required meteorological products from the Imager, at least 12 channels are required with the optimum of 16 channels. The minimum 12 channels are 6 wavelength bands used for current geostationary satellite, and additional channels in two visible bands, a near infrared band, two water vapor bands and one ozone absorption band. From these enhanced channel observation, we are going to derive and utilize the information of water vapor, stability index, wind field, and analysis of special weather phenomena such as the yellow sand event in addition to the standard derived products from the current geostationary Imager data. For a better temporal coverage, the Imager is required to acquire the full disk data within 15 minutes and to have the rapid scan mode for the limited area coverage. The required thresholds of spatial resolutions are 1 km and 2 km for visible and infrared channels, respectively, while the target resolutions are 0.5 km and 1 km.

Selection of Tissue Papers for Nematode Extraction from Soil in Combined Screening-funnel Method (토양선충분리(土壤線蟲分離)를 위(爲)한 여과지(濾過紙) 선발(選拔)에 관(關)하여)

  • Cho, Myoung-Rae;Choi, Young-Eoun
    • Korean journal of applied entomology
    • /
    • v.24 no.1 s.62
    • /
    • pp.39-44
    • /
    • 1985
  • This study was undertaken to select a suitable Korean tissue paper for Baermann funnel method. Ten kinds of five manufacturers were evaluated as to nematode extraction efficiency in Baermann funnel. 'Crown Hankie'(Korea Special Paper Co., Ltd.) had suitable properties in nematode permeability and strength regardless of three soil types, loamy sand, sandy loam and clay loam. The number of nematodes extracted using 'Crown Hankie' 4 ply was 198, while that of 'Cottonwool Nematode Filter' was 227. Un-perfumed tissue papers showed higher nematode extraction efficiencies than perfumed tissue papers by 53 and 23% in 'Kleenex New Softness' and 'Monaliza Finely Soft Tissue', respectively. Among the nematode extraction efficiencies by temperatures, $15^{\circ},\;25^{\circ}\;and\;35^{\circ}C$, it was highest at $35^{\circ}C$. In experiment of evaluating nematode extraction using Baermann funnel at 12 hours interval to 92 hours, 35.3 and 40.3% of nematodes were extracted after 12 and 24 hours, respectively.

  • PDF

TENSILE BOND STRENGTH BETWEEN ELASTOMERIC IMPRESSION MATERIALS AND TRAY RESINS DEPENDING ON THE THICKNESS OF THE TRAY ADHESIVE

  • Kim, Tae-Won;Moon, Hong-Seok;Lee, Keun-Woo;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.6
    • /
    • pp.699-711
    • /
    • 2006
  • Statement of problem. Elastomeric impression materials have been widely used to obtain an accurate impression. However there have not been enough studies on the influence of the thickness of the tray adhesives on the bonding strength between the trays and the elastomeric impression materials. Purpose. In order to understand the relationship between the thickness of the tray adhesive and the tensile bond strength and to suggest the thickness at which the bonding strength is strongest, tensile bond strength related to the thickness of adhesives of 3 different elastomeric impression materials were tested. Materials and methods. 3 impression materials, $Permlastic^{(R)}$. Regular Set(Kerr Corp., Romulus, Michigan, U.S.A.), $Impregum^{TM}$ $Penta^{TM}$(3M ESPE, Seefeld, Germany), and Aquasil Ultra Monophase Regular Set Smart Wetting.(Dentsply Caulk, Milford, Delaware, U.S.A.), were used in this study, and tray adhesives from the same manufacturers of the impression materials were used, which were Rubber Base Adhesive, Polyether Adhesive, and Silfix, respectively. The tray specimens were prepared by autopolymerizing the tray material(Instant Tray Mix, Lang, Wheeling, Illinois, U.S.A.), and a PVC pipe was used to house the impression material. In group A, tray adhesives were applied in multiple thin layers of 1 to 5 and in group B, adhesives were applied only once, in the thickness equivalent to several applications. Lightness($L^*$) of the adhesion surface was measured with a spectrophotometer(CM-3500d, Konica Minolta, Sakai, Osaka, Japan). The tensile bond strength of the elastomeric impression material and the tray resin was measured with universal materials testing machines(Instron, Model 3366, Instron Corp, Nowood, Massachusetts, U.S.A.). A formula between the number of adhesive application layers and the lightness of the adhesion surface was deduced in group A, and the number of adhesive layers in group B was estimated by applying the lightness($L^*$) to the deduced formula. Results. 1. In group A, a statistically significant increase in tensile bond strength appeared when the number of application layers increased from 1 to 2 and from 4 to 5, and no significant difference was present between 2, 3, and 4 layers in Permlastic. In Impregum, the tensile bond strength was significantly increased when the number of adhesive layers increased from 1 to 3, but no significant difference after 3 layers. In Aquasil, the tensile bond strength significantly increased as the number of application layers increased up to 4 but showed no significant difference between 4 and 5. 2. In group B, the tensile bond strength was decreased when the thickness of the adhesive increased in Permlastic. Impregum showed an increased tensile bond strength when the thickness of the adhesive was increased. In Aquasil, the tensile bond strength increased as the number of adhesive application layers increased up to approximately 2.5 layers but it sharply decreased after approximately 4.5. Conclusion. From the study, the common idea that it is better to apply a thin and single coat of tray adhesive needs correction in more detailed ways, and instructions on some of the tray adhesives should be reconsidered since there were several cases in which the tensile bond strength increased according to the increase in the thickness of the adhesives.