Mammography using mammography equipment is a method of examination that is being employed most widely to diagnose the early stages of breast cancer. Detecting or diagnosing a fibrous tissue, micro calcification, or mass in the breast is influenced by the quality management of mammography equipment considerably. Particularly in mammography, quality management refers to a behavior of figuring out and correcting all sorts of hindrance factors that can cause all the problems related to the equipment associated with the diminishment of diagnosed area due to the reduction of image quality in clinical imaging in advance and maintaining a consistent level of image quality and obtaining a proper image. Here, these researchers aim to summarize and report the general contents of quality management in mammography using mammography equipment.
Mammography equipment is an essential detector for making an early diagnosis of female's breast lesion. Recently, in most hospitals, a digital mammography detector is used due to the wide and consistent supply of digital mammography equipment. However, the average effective radiation is increasing due to the indiscreet use of CR or DR mammography. The purpose of this study is to recognize the possible indirect radiation damage, which can be occurred due to an excessive effective exposure of radiation, by evaluating spacial radiation rate of the digital mammography detector used for female patient. Consequently, the high mount of spacial radiation showed digital mammography equipment on the horizontal direction. Considering the result, digital mammography equipment should be installed by avoiding along the horizontal direction.
Proceedings of the Korean Society of Medical Physics Conference
/
2002.09a
/
pp.38-41
/
2002
Mammography is considered the single most important diagnostic tool in the early detection of breast cancer. Today's dedicated mammographic equipment, specially designed x-ray screen/film combinations, coupled with controlled film processing, produces excellent image quality and can detect very low contrast small lesions. In mammography, it is most important to produce consistent high-contrast, high-resolution images at the lowest radiation dose consistent with high image quality. Some of the major technical development milestones that have let to today's high quality in mammographic imaging are reviewed. Both the American College of Radiology Mammography Accreditation Program and the Mammography Quality Standards Act have significant impact on the improvement of the technical quality of mammographic images in the United States and worldwide. A most recent development in digital mammography has opened up avenues for improving diagnosis.
In this study, we measure dose against various density and thickness using phantom to compare FFDM to DBT of Digital mammography equipment and evaluate usefulness of DBT through compare the image quality of FFDM and DBT. We use mammography equipment, Selenia Dimensions ; this is able to examine breast by both FFDM and DBT, The results are that when the thickness of phantom is 6cm or more and density is 70% or more and the thickness of phantom is 7cm or more and density is 50% or more, AGD of DBT is lower than that of FFDM. The evaluation results of image quality are that in the tumor and small calcification group that composed by mammary tissue and fat, FFDM is great and in fibrin, DBT is great. But in the all thicknesses of BR3D phantom that reflected overlapped tissue of breasts, DBT is great in calcification group, fibrin and tumor. DBT is greater image quality and lower dose more than FFDM in Thick and high density breast, Therefore, DBT is more useful in Korean women's breast that is characterized dense breast than FFDM.
As breast cancer shows the highest incidence among women's cancers, the use of mammography is also increasing as a screening test. Mammography should produce high-quality images for accurate diagnosis. For this, it is necessary to manage the performance and image quality of mammography. Thus, in order to investigate quality control, the present study conducted a questionnaire survey of 37 hospitals registered as breast cancer medical examination centers in Gwang-Ju, concerning their quality control of mammography. In the results of surveying the characteristics of apparatus use for mammography, many respondents did not know about the equipment that they were using. Of the hospitals, 19 (49%) were using film, 19 (49%) CR, and 1 DR. In the results of asking how to do quality control, only 38% answered that they inspected according to the manual. In addition, all the surveyed hospitals had specialized agencies do quality control for them. As to the reason for using agencies, 65% mentioned limitations in personnel, time, distance, etc, and 44% mentioned the absence of machines and materials. These results suggest that quality control is being performed perfunctorily, as well as passively and indifferently as it relies on specialized agencies. Accordingly, it is necessary to provide regular education for enhancing people's perception of quality control and to perform quality control adequately in the presence of Radiologist.
Mammography using X-rays is currently the most used for early diagnosis of breast cancer. As the frequency of use of X-ray devices increases, interest in radiation hazards caused by mammography is increasing. Therefore, in this study, in order to measure the exposure dose of the mammary gland in X-ray mammography that requires high contrast and high resolution, the international Atomic Energy Agency (IAEA) stipulates the international standards presented by IEC 62220-1-2: 2015. Based on the beam quality criteria of the recommendation, we tried to present a guideline for evaluating the average mammary gland dose. As a result, the average streamline dose value of the 4.5 cm PMMA phantom was 2.3 mGy at the maximum within the 30 kV range, and was evaluated to be 1.19 mGy based on 28 kV.
More than 4 million women undergo breast cancer (BC) screening with mammography each year in Korea. Digital mammography (DM) was introduced in 2000, and it has been reported to have a higher diagnostic accuracy than screen-film mammography (SFM) or computed radiography (CR) in women with dense breasts. According to a study using data from the National Cancer Screening Program for BC, the diagnostic accuracy of DM was higher than those of SFM and CR, regardless of age, breast density, and screening round. Currently, despite high supply rate among OECD countries, the distribution of DM equipment is approximately 35% in Korea. For quick replacement with DM, it will be necessary to improve its fee for the National Health Insurance and support an educational program for radiologists. In addition, efforts should be made to increase the accessibility of DM.
Digital Mammography is very important for the early diagnosis of breast cancer. but excessive radiation dose to the patient may increase the probability of occurrence of breast cancer. absorbed dose rate and signal, noise, and contrast in accordance with the change of the filter, and analyzed the signal-to-noise ratio. absorbed dose rate GE Equipment is higher than that of Siemens and Hologic. using the material of Mo / Mo was lower than the other target-filter combination. SNR of Siemens equipment is high and measured high when Mo / Mo selected, the other two devices was measured high when Mo / Rh selected. when you choose a target-filter combination our results will be a good indicator.
Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Lee, Eul-Kyu;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
Journal of radiological science and technology
/
v.39
no.3
/
pp.415-420
/
2016
The purpose of this study was to evaluation of the performance characteristic for mammography by using edge device that mammography equipment improves essential in the correct diagnosis for the maintenance. We measured the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using the 61267 RQA-M2 based on commission standard international electro-technical commission (IEC). As a results, spatial resolution of elenia demensions tomo and lorad selenia mammography were maintained at $10mm^{-1}$ and NPS and DQE including the low nyquist frequency indicated to $6.0mm^{-1}$. Therefore, regulary QA of mammography system should be necessary. This study can be contribute to evaluate QA for performance characteristic of mammography of DDR system.
Mammography is the most useful test for the early diagnosis of breast cancer. The MammoPad can be used for the purpose of reducing the pain felt by the patient due to the pressure of the breast. MammoPad cushion the pressure between the breasts and the equipment and reduce the patient's discomfort. A new material pad was fabricated to solve the problem of the H-pad which is currently in circulation. Quantitative evaluation of SNR and CNR and qualitative evaluation of imitation lesion using ACR Phantom were performed. In the quantitative evaluation, SNR and CNR of Non pad and Filter pad were not statistically significant.(p>0.05) In the qualitative evaluation, Fiber and Imitation lesion of H-pad and Filter pad were statistically significant(p<0.05), and all values of Calcification and Mass were not statistically significant. (p>0.05) In addition, Fiber, calcification, mass, and imitation lesion were not statistically significant in both Non pad and Filter pad.(p>0.05) Through this study, it was confirmed that the newly created Filter pad minimizes image quality degradation and can replace existing products.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.