• 제목/요약/키워드: malposition

검색결과 103건 처리시간 0.037초

횡복직근 유리피판을 이용한 유방재건술에서의 즉시 유두재건 (Immediate Nipple Reconstruction in Breast Reconstruction with TRAM Free Flap)

  • 김정태;김창연;차지훈;황원중
    • Archives of Plastic Surgery
    • /
    • 제32권1호
    • /
    • pp.76-84
    • /
    • 2005
  • Immediate breast reconstruction in breast cancer patients is universalized and now with a wide variety of methods to choose from, we can select a breast reconstruction method according to the patient's condition. Among these methods, immediate breast reconstruction with TRAM free flap is the most commonly used. Nipple reconstruction is usually performed as a secondary procedure, reconstructed. Nipple is reconstructed with contralateral nipple composite graft or with local flap. Areola is reconstructed with skin graft and tattooing. Therefore, to reconstruct complete breast, two or more staged operations are needed and are troublesome to both the surgeon and the patient. If we could reconstruct breast mound and nipple at same time, we would reduce the operative stages and heighten the patient's satisfaction. The author performed delayed or immediate breast reconstruction with TRAM free flap and nipple reconstruction at the same time. If the TRAM flap was to situate in the whole of the breast or at the center of the breast mound, nipple was reconstructed with a local flap from the TRAM flap. If the TRAM flap was not situated in center of breast mound, nipple was reconstructed with a local flap from remnant breast skin. Immediate nipple reconstructions in breast reconstruction consisted total of 22 cases. Among these, delayed breast reconstruction were 5 cases and immediate breast reconstruction were 17 cases. According to patient's condition and mastectomy method, nipple reconstruction method was selected; nipple reconstruction with contralateral nipple composite graft(3 cases); nipple reconstruction with remnant breast skin(6 cases); nipple reconstruction from flap margin(10 cases); nipple reconstruction with prefabricated nipple on flap(3 cases). Malposition of the reconstructed nipple was the most common and serious complication(6 cases). The other complications were atrophy of the nipple(1 case), and necrosis(1 case). Reconstruction of the breast and nipple at the same time can reduce the need of a secondary operation and use remnant skin or redundant flap tissue maximally. On the other hand, it must be considered that position and shape of nipple could be deformed, because the nipple reconstruction is performed before the shape of reconstructed breast settles completely. Prudent attention is needed, because the danger of complication is higher than delayed nipple reconstruction.

완전 거치형 정맥도관의 임상분석 (Clinical Review of Totally Implantable Venous Catheter)

  • 김정태;오태윤
    • Journal of Chest Surgery
    • /
    • 제40권10호
    • /
    • pp.691-695
    • /
    • 2007
  • 배경: 중심정맥 도관은 1979년 처음 사용된 이래로 암환자의 치료에 있어 많은 편의를 제공하였다. 이에 본원 흉부외과에서는 완전 거치형 정맥도관의 임상 양상 및 사용에 따른 합병증 등을 분석하여 향후 치료에 도움이 되고자 본 연구를 하였다. 대상 및 방법: 2004년 11월부터 2006년 2월까지 완전 거치형 정맥도관 시술을 받은 100명의 환자를 대상으로 후향적 연구를 하여 다음과 같은 결과를 얻었다. 결과: 완전 거치형 정맥 도관 시술의 삽입정맥으로는 우측 쇄골하정맥 삽입이 74예(74%)였으며 좌측쇄골하 정맥(21예, 21%), 우측 경정맥(3예, 3%), 좌측 경정맥(1예, 1%)을 사용하였으며 1예에서는 우측 대퇴정맥을 사용하였다. 초기 합병증으로는 위치 이상이 5예(5%)와 동맥천자한 경우 5예 있었다. 만기 합병증으로는 쇄골하 정맥 혈전 형성이 한 예 있어 현재 항응고제 복용중이며 pinch off 증후군이 2예 있었다. 그 외의 초기 또는 만기 합병증은 없었다. 결론: 완전 거치형 도관의 사용은 합병증의 발생률은 낮고 비교적 안전한 방법이지만 감염, 혈전 형성, 도관의 절단 등은 장기간 사용시 나타날 수 있는 합병증으로 초기에 진단 및 치료가 된다면 더 큰 합병증을 예방할 수 있다.

상악 구개측 중앙부에 매복된 과잉치 (MESIODENS IN THE VAULT OF THE PALATE)

  • 민성진;김성오;이제호;곽지윤;최병재;최형준
    • 대한소아치과학회지
    • /
    • 제32권4호
    • /
    • pp.670-674
    • /
    • 2005
  • 과잉치는 치배 형성기에 정상 치판의 과도한 증식의 결과로 발생하며 산발적일 수도 있고 유전적일 수도 있다 발생 빈도는 $1{\sim}3%$이며, 2:1의 비율로 남아에게 호발한다. 주로 상악 전방부에서 많이 발견되며 매복, 영구치의 위치 이상, 정중부 이개, 낭종, 비강으로의 맹출 등과 같은 다양한 합병증을 나타낼 수도 있다. 상악 전방부에서 발견되어지는 과잉치는 치축방향에 따라 위치가 결정되며 상악 전방부 과잉치의 1/3정도는 역위 매복되어 맹출의 가능성이 없지만, 치낭의 치관 부위가 정상적인 관계로 존재하는 한 과잉치의 이동이 일어날 수 있다. 치아의 이동은 경구개, 소구치 부위, 비강까지도 일어날 수 있다. 또한 전상악 수직고경의 성장으로 시간이 지남에 따라 외과적 접근이 어려워질 수 있다. 이에 본 두 증례에서는 역위 매복된 상악 전방부의 과잉치가 구개 측 중앙부까지 이동된 것을 발견하여 외과적으로 제거하였다.

  • PDF

소아에서 완전 이식형 중심정맥포트를 위한 두정맥 절개술의 유용성 (The Usefulness of Cephalic Vein Cut-Down for Totally Implantable Central Venous Port in Children)

  • 정규환;문석배;정성은;이성철;박귀원
    • Advances in pediatric surgery
    • /
    • 제14권1호
    • /
    • pp.67-74
    • /
    • 2008
  • The usefulness of totally implantable central venous port for long-term intravenous infusion is widely accepted in children. Usually the catheters are placed through the internal or external jugular vein. In case of jugular vein cut-down, two separate incisions are needed for catheter and port respectively. Patients also feel uncomfortable as the catheter run through the neck. However these disadvantages can be overcome by using the cephalic vein (CV). We reviewed our experiences on CV cut-down for totally implantable central venous port in children. From January 2002 to December 2006, 201 patients (M:F=127:74) underwent 218 central venous port insertions. Mean age at operation was 5.9 years (2 months - 19 years). Indications included chemotherapy (N=167), long-term intravenous antibiotics infusion (N=36), and total parenteral nutrition (N=15). CV was selected preferentially. The incision includes the deltopectoral triangle laterally, and both the CV cut-down and port insertion were achieved with a single incision. The number of insertion through external, internal jugular vein, and CV was 77, 66 and 75, respectively. The median age, height and body weight were higher in CV cut-down group. The youngest age for CV cut-down was 8 months, the shortest height was 69 cm and the smallest body weight was 5.9 kg. Of 118 trials of CV cut-down, cut-down was successful in 75 cases (63.6 %). CV was absent in 10 cases(8.4 %) and CV was sacrificed after catheter tip malposition in 10 cases (8.4 %). There was only one complication, in which the catheter was inserted into the minute branch of subclavian artery. The CV cut-down method for totally implantable central venous port was safe and feasible in selected groups of patients in children. In addition, preservation of jugular vein and a more favorable cosmetic effect are other benefits of CV cut-down.

  • PDF

파괴폐에서 발생한 대량객혈의 치료: Endobronchial Blocker를 이용하여 반대측 폐로의 흡인을 방지한 후 시행한 전폐절제술 (Treatment of Massive Hemoptysis Occurred from Destroyed Lung: Prevention of Contralateral Aspiration Using Endobronchial Blocker Followed by Pneumonectomy)

  • 김슬기;이은정;박지영;김은영;강경환;정회훈;최천웅;김이형;유지홍;곽영태;조상호;정준영;김대현
    • Tuberculosis and Respiratory Diseases
    • /
    • 제72권1호
    • /
    • pp.68-71
    • /
    • 2012
  • Untreated massive hemoptysis, especially in patients with tuberculous-destroyed lung, is a serious complication resulting in considerable morbidity and mortality. We report a case of a patient who had active tuberculosis and a destroyed left lung with massive bleeding. He was transferred to our clinic with intubation of a right-sided Robertshaw double lumen tube and right upper lobe collapse likely due to tube malposition that was presented on chest X-ray. Because hemoptysis had persisted after bronchial arterial embolizaton, we replaced the double lumen tube with a conventional endotracheal tube and inserted an endobronchial blocker into the left main bronchus through an endotracheal tube guided by bronchoscopy to prevent aspiration of blood into the right lung. Left pneumonectomy was performed and hemotpysis was ceased. We suggest that the use of an endobronchial blocker followed by surgery may be a safe and effective modality of treatment in patients with persistent bleeding after bronchial arterial embolization.

구개측 매복된 상악 견치의 교정적 치험례 (ORTHODONTIC TREATMENT OF THE PALATALLY IMPACTED MAXILLARY CANINE)

  • 감동훈;김정욱;한세현
    • 대한소아치과학회지
    • /
    • 제25권1호
    • /
    • pp.127-133
    • /
    • 1998
  • An impacted tooth is defined pathologically as a tooth that remains under the mucosa of inside bone without eruption of the crown after a specific period of eruption. Clinically, the term includes those teeth, even before eruption period, that are not expected to erupt due to shape, position and alignment of tooth and lack of space. Canine is prone to impaction more than other teeth because it has the longest time to develop and a complex route from the place of formation to the site of eruption. The impaction incidence of maxillary canine is repoted 0.92$\sim$3.3% (Ferguson, 1990). In 1995 Orton reported that the incidence was 0.92$\sim$2.2% and palatal impaction was more frequent than labial impaction(85%:15%). In 1969 Johnston presented it was more common to woman than to man(3:1). The etiology includes systemic disease such as endocrine disorder, cleidocranial dysostosis, irradiation, Crouzon syndrome, ricketts, facial hemihypertrophy and hereditary and local problems such as ectopic position of the tooth, distance of tooth from its place of eruption, malformation of the tooth, presence of supernumerary teeth, trauma of tooth germ, infection of tooth germ, displacement of tooth germ or tooth by a neoplasm, ankylosis, overretention of deciduous predecessor, lack of space for the tooth in the dental arch and mucosal barrier due to gingival fibrosis. The maxillary canine is especially important as it has the longest root, provides guidance for lateral movement of the mandible and masticatory function and assumes an important role esthetically as it is located at mouth angle. If left untreated, it may cause migration and external, internal resorption of adjacent teeth, loss of arch length, formation of dentigerous cyst or tumors, infection and referred pain as well as malposition of the tooth. Therefore, periodic examination of the development and eruption of the maxillary canine is especially important in a growing child. This case study presents the results of treatment of palatally impacted maxillary canine utilizing surgical exposure and orthodontic tooth movement on patients visiting SNUDH dept. of pediatric dentistry.

  • PDF

뇌실 복강간 단락 부전의 기여인자 (The Contributory Factors of CSF Shunt Failure)

  • 김영돈;황성규;황정현;성주경;함인석;박연묵;김승래
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권sup1호
    • /
    • pp.79-84
    • /
    • 2001
  • 목 적 : 뇌실 복강간 단락술 부전의 기여인자를 조사 및 분석하여 뇌실 복강간 단락술의 합병증 및 재수술의 가능성을 줄이는 데에 목적이 있다. 대상 및 방법 : 1995년 1월부터 1998년 12월까지 본원에서 뇌실 복강간 단락술을 시행 받은 237명의 수두증 환자를 후향적 방법으로 고찰하여 뇌실 복강간 단락 부전의 기여인자 및 단락기 생존율을 통계학적으로 분석하였다. 결 과 : 수두증의 원인은 종양, 출혈, 감염, 선천성 기형, 정상 뇌압 수두증, 외상 등이었다. 68명의 환자에서 109회의 재수술이 이루어졌다. 재수술의 이유는 폐색, 근위부 카세타의 위치이상, 감염 등이었다. 단락기 생존율은 1년, 2년, 3년에 각각 77.1%, 75.4%, 74.1%이었다. 10세 이하의 환자에서 재수술의 빈도가 통계학적으로 의의 있게 높았다. 그리고 수두증의 원인에 따라서 통계학적으로 의의 있게 재수술의 빈도 차이가 있었다. 결 론 : 대부분의 뇌실 복강간 단락 부전은 술후 1년내에 발생하였다. 환자의 나이 및 수두증의 원인이 뇌실 복 강간 단락 부전의 주요 기여인자였다.

  • PDF

A Single-Center Experience of Robotic-Assisted Spine Surgery in Korea : Analysis of Screw Accuracy, Potential Risk Factor of Screw Malposition and Learning Curve

  • Bu Kwang Oh;Dong Wuk Son;Jun Seok Lee;Su Hun Lee;Young Ha Kim;Soon Ki Sung;Sang Weon Lee;Geun Sung Song;Seong Yi
    • Journal of Korean Neurosurgical Society
    • /
    • 제67권1호
    • /
    • pp.60-72
    • /
    • 2024
  • Objective : Recently, robotic-assisted spine surgery (RASS) has been considered a minimally invasive and relatively accurate method. In total, 495 robotic-assisted pedicle screw fixation (RAPSF) procedures were attempted on 100 patients during a 14-month period. The current study aimed to analyze the accuracy, potential risk factors, and learning curve of RAPSF. Methods : This retrospective study evaluated the position of RAPSF using the Gertzbein and Robbins scale (GRS). The accuracy was analyzed using the ratio of the clinically acceptable group (GRS grades A and B), the dissatisfying group (GRS grades C, D, and E), and the Surgical Evaluation Assistant program. The RAPSF was divided into the no-breached group (GRS grade A) and breached group (GRS grades B, C, D, and E), and the potential risk factors of RAPSF were evaluated. The learning curve was analyzed by changes in robot-used time per screw and the occurrence tendency of breached and failed screws according to case accumulation. Results : The clinically acceptable group in RAPSF was 98.12%. In the analysis using the Surgical Evaluation Assistant program, the tip offset was 2.37±1.89 mm, the tail offset was 3.09±1.90 mm, and the angular offset was 3.72°±2.72°. In the analysis of potential risk factors, the difference in screw fixation level (p=0.009) and segmental distance between the tracker and the instrumented level (p=0.001) between the no-breached and breached group were statistically significant, but not for the other factors. The mean difference between the no-breach and breach groups was statistically significant in terms of pedicle width (p<0.001) and tail offset (p=0.042). In the learning curve analysis, the occurrence of breached and failed screws and the robot-used time per screw screws showed a significant decreasing trend. Conclusion : In the current study, RAPSF was highly accurate and the specific potential risk factors were not identified. However, pedicle width was presumed to be related to breached screw. Meanwhile, the robot-used time per screw and the incidence of breached and failed screws decreased with the learning curve.

척추 수술 후 영상 평가: 초기 및 중장기 합병증 (Imaging Evaluation of Early and Long-Term Complications Associated with the Postoperative Spine)

  • 박재휘;김동현;채지원;김효진;서지운;손진영
    • 대한영상의학회지
    • /
    • 제85권1호
    • /
    • pp.36-53
    • /
    • 2024
  • 척추 수술의 빈도 증가와 더불어 radiography, CT, MRI 등의 의료 영상 촬영 건수도 증가하고 있으며, 이와 관련된 영상 판독의 중요성이 점점 더 커지고 있다. 본 논문에서는 척추 수술 후 발생 가능한 다양한 합병증을 이해하고, 이를 정확하고 효과적으로 진단하는 영상 검사의 중요 소견에 대해 다루고자 한다. 특히, 수술 후 초기 및 중장기 합병증을 구분하여, 각 시기별 특징적인 영상 소견을 자세히 설명한다. 척추 수술 후 초기 합병증으로는 부적절한 수술 기구 배치(instrument malposition), 장액종(seroma), 혈종(hematoma), 거짓수막류(pseudomeningocele), 수술 주변 감염(infection) 등이 있으며, 중장기 합병증으로는 수술 기구 주변의 골용해(osteolysis), 융합 실패(failure of fusion), 인접 분절 질환(adjacent segment disease), 경막외 섬유화 또는 흉터 조직(epidural fibrosis or scar) 형성 등이 포함된다. 이러한 척수 수술 후 발생하는 합병증 관련 영상 평가에 대한 정확한 이해는 척추 수술 후 합병증을 적시에 정확하게 진단하여 효과적인 환자 치료에 기여할 것이다.

심방 중격 결손의 경피적 폐쇄술 후 발생한 합병증에 관한 연구 (Complications of transcatheter closure of atrial septal defects using the amplatzer septal occluder)

  • 제서진;권효진;장기영;이재영;김수진;손창성;이주원
    • Clinical and Experimental Pediatrics
    • /
    • 제51권4호
    • /
    • pp.401-408
    • /
    • 2008
  • 목 적 : 이차공 심방 중격 결손의 경피적 폐쇄술은 수술을 대체할 수 있어 안전하고 효과적인 치료로서 자리를 잡아가고 있으나, 드물게 합병증의 발생이 보고되고 있어, Amplatzer septal occluder를 이용한 심방 중격 결손의 경피적 폐쇄술 후 발생한 초․중기 합병증 및 그 대책을 살펴보고자 하였다. 방 법 : 2003년 6월부터 2006년 5월까지 부천세종병원과 고려대학교 의료원에서 이차공 심방 중격 결손을 진단 받은 64명의 환자를 대상으로 하였다. 남녀 비는 1:2.4였고, 시술 당시 나이는 2.6에서 64세(중앙값 : 17세), 시술 당시 체중은 13 kg에서 100 kg (중앙값 : 47.5 kg)이었다. 결 과 : 경흉부 또는 경식도 심장 초음파 검사상 결손의 크기는 6 mm에서 28 mm (중앙값 : 15 mm), 풍선 확장 시 결손의 크기는 6.5 mm에서 34 mm (중앙값 : 18 mm)이었고, 사용한 Amplatzer septal occluder의 크기는 6 mm에서 36 mm (중앙값 : 19.5 mm)로 풍선 확장 시 결손의 크기와 같거나 1-2 mm 큰 크기의 기구가 사용되었다. 시술 후 발생한 합병증으로는 부정맥(2례), 기구 변형(2례), 대동맥 우심방 간 누공 형성 및 용혈성 빈혈(1례), 승모판 잠식(1례), 기구 위치 이상(1례), 잔류 단락(1례), 하대 정맥 천공(1례) 등이 있었다. 결 론 : ASO를 이용한 심방 중격 결손의 경피적 폐쇄술은 안전성이나 효과, 기술적인 면에서 수술을 대체할 수 있는 효율적인 치료로 생각된다. 그러나 드물게 발생하는 기구 이탈이나 부정맥, 심장막 삼출, 누공 형성 등의 합병증이 발생할 수 있으므로 시술 전 주의 깊게 대상 환자를 선정하고, 심방 중격 결손의 정확한 해부학적 이해와 기구 선택이 필요하며 시술 후 추적 관찰을 통해 합병증의 조기 발견 및 예방이 필요할 것으로 판단된다.