• Title/Summary/Keyword: maintenance type

Search Result 1,802, Processing Time 0.028 seconds

An Experimental study on the Construction Standard for Sealer of Injection Type for Leakage Maintenance (누수보수용 주입형 실링재의 시공 기준에 관한 실험적 연구)

  • Lim Min-Chan;Cho Il-Kyu;Seon Yun-Suk;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.51-54
    • /
    • 2005
  • The concrete structure hasn't perfect waterproofing performance but if it doesn't have a joint part that could isolate a permeability. Concrete structure(communication tunnel and underground structure) has an expansion joint and construction joint. There are a lot of joint type after construction or expansion, shrinkage, vibration, over load, performance of decline etc.. they offer a water of way by variety change. In this reason, It carries in effect a waterproofing work for the concrete structure of waterproofing. but the structure has a behavior that cause a problem by waterproofing layer of damage, heaving phenomenon, temperature of shrinkage. In this study, we will estimate a field of application for Sealer of injection type for leakage maintenance of construction standard on the waterproofing performance.

  • PDF

Damage assessment of shear-type structures under varying mass effects

  • Do, Ngoan T.;Mei, Qipei;Gul, Mustafa
    • Structural Monitoring and Maintenance
    • /
    • v.6 no.3
    • /
    • pp.237-254
    • /
    • 2019
  • This paper presents an improved time series based damage detection approach with experimental verifications for detection, localization, and quantification of damage in shear-type structures under varying mass effects using output-only vibration data. The proposed method can be very effective for automated monitoring of buildings to develop proactive maintenance strategies. In this method, Auto-Regressive Moving Average models with eXogenous inputs (ARMAX) are built to represent the dynamic relationship of different sensor clusters. The damage features are extracted based on the relative difference of the ARMAX model coefficients to identify the existence, location and severity of damage of stiffness and mass separately. The results from a laboratory-scale shear type structure show that different damage scenarios are revealed successfully using the approach. At the end of this paper, the methodology limitations are also discussed, especially when simultaneous occurrence of mass and stiffness damage at multiple locations.

A Study on the Posture Maintenance Performance and Self-Efficacy in accordance with Posture Correction Program (자세교정프로그램에 따른 자세유지 수행과 자기효능감에 관한 연구)

  • Jang, Su-Gyeong
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.459-474
    • /
    • 2000
  • The purpose of this study is to identify the posture correction program as the development of the posture maintenance performance, and search for the more efficient posture correction program. The data analysis was processed by SPSS. The data was analysed with $x^2$-test, t-test, pearson product moment correlation, and stepwise regression analysis. The finding of this study is as follows: There are the homogeneity between two groups was verified on the know ledges CF=.697, df=2, P>.05), self-efficacy(F=.098, df=2, P>.05) about the posture. The developed posture correction program has proved to enhance the posture maintenance performance(knowledge t=1.60, P<.05 ; posture manintenance t=7.69, P<.01). The type of posture correction program showed some significant differences (t=5.62, P<.01) in the accuracy of movement way among the factors of the posture maintenance performance. The posture maintenance performance affected self-efficacy. Therefore, the major conclusion is as follows: The posture correction program was meaningfully effective on developing the posture maintenance, and with practice created accuracy much more on the posture maintenance movement way. The development of the posture maintenance performance affected the increase of self-efficacy about the posture. The self-efficacy has proved so powerful factor to influence on the posture maintenance performance development. So, the posture correction program should be done systematically and continually, and developing the posture maintenance performance should be done with practice. After the education, it should be reinforced through practice, midterm identification and reeducation and motivated with recognizing the accurate posture measurement. And it should be created the correction program to develop the high self-efficacy about the posture. It needs the strategy to educate the correct posture individually, and to spread to the society for healthy life style.

  • PDF

EFFECTS OF CIMATEROL ON CARCASS AND SKELETAL MUSCLE CHARACTERISTICS UNDER AD LIBITUM AND RESTRICTED FEEDING CONDITIONS IN LAMBS

  • Kim, Y.S.;Lee, Y.B.;Ashmore, C.R.;Han, I.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.1 no.4
    • /
    • pp.223-232
    • /
    • 1988
  • Fifty-two wether lambs weighing 30 kg were randomly assigned to 5 treatment groups; 1) initial slaughter. 2) control-maintenance (CON-MT), 3) control-ad libitum (CON-AL), 4) cimaterol-maintenance (CIM-MT) and 5) cimaterol-ad libitum (CIM-AL). Ad libitum-fed animals had free access of a high-concentrate diet, whereas maintenance animals were restricted in feed intake to maintain the initial weight of 30 kg for 90 days. Cimaterol was administered in the feed at 10 mg/kg. Regardless of feeding level, the administration of CIM improved carcass weight (p < .05), dressing % (p < .01), longissimus muscle area (p < .01), leg conformation and muscling (p < .01), USDA yield and quality grades (p < .01) and protein concentration (p < .01) in carcass as well as in muscle. Cimaterol feeding decreased organ wt (p < .01), baekfat depth (p < .01), intramuscular fat and overall fatness. Cimaterol was effective for muscle accretion even under restricted feeding condition. The greater accretion of muscle was the result of the hypertrophy of both type I and type II muscle fibers but the hypertrophy of type II fiber (110%) was much greater than that of type I fiber (37%). Cimaterol feeding decreased muscle DNA concentrations but the number of nuclei per muscle fiber was not changed, indicating that the lower DNA concentration was due to the dilution effect caused by the hypertrophy of muscle fiber. As evidenced by lower flank streaking, lower marbling and darker muscle, CIM feeding adversely affected meat quality. Meat tenderness was also adversely affected, resulting in significantly (p H .01) tougher meat in CIM-fed animals.

Factors Influencing to Select Types of U.S. Hospital Network (미국 병원의 네트워크 유형 선택에 영향을 미치는 요인분석)

  • 김양균
    • Health Policy and Management
    • /
    • v.14 no.2
    • /
    • pp.1-16
    • /
    • 2004
  • The study purpose was to find which factors affect selection of hospital network types. This study used the 1998 American Hospital Association Annual Survey Database from Health Forum. Among these U.S. hospitals, the researcher selected hospitals located in Metropolitan Statistical Areas. Therefore the final observation cases for analysis are 1,971 Metropolitan Statistical Area hospitals in the United States. To identify significant variables influencing hospital network types, the study used proportional odds logistics regression model on population size, Health Maintenance Organization penetration rate, and market competition rate of area including a hospital, types of hospital ownership, hospital bed size, proportion of Medicare patients and Medicaid patients in total hospital patients, and occupancy rate. Contrary to conventional wisdom, selection of hospital network types was influenced by population size of area which a hospital located, types of ownership, hospital bed size, and proportion of medicare patients rather than Health Maintenance Organization penetration. Population size 1,000,000-2,499,999 had the highest probability of selecting type IV (clinical-vertical integration) from an independent hospital, and a religious group owned hospitals and for-profit owned hospitals had the highest probability of selecting Type IV (clinical-vertical integration) from an independent hospital. A bed size had positive relation on selecting Type IV (clinical-vertical integration) from an independent hospital. Unlikely general belief that the selecting types of hospital network was determined by the change of health insurance policy such as Health Maintenance Organizations and Preferred Provider Organizations, the types of hospital network were influenced by community characteristics such as population size, and hospital characteristics.

A Study on the Repair Time of the Construction Type in the Apartment Housings (공동주택 공종별 수선시기 설정 연구)

  • Lee, Kang-Hee;Park, Geun-Soo;Chae, Chang-U
    • Journal of the Korean housing association
    • /
    • v.22 no.4
    • /
    • pp.83-92
    • /
    • 2011
  • Apartment is settled down as a main housing type and massive supply has been conducted since 1990's. The government has focused on the housing supply to improve the housing number and cut its price. On the contrary, the management of the housing has been neglected to get an early deterioration. Since 1995's, various ways have been made to improve and maintain the building function and performance. Among these, the long-term repair plan has played a main role to manage the housing condition and plan the repair schedule for preparing the massive cost of repair such as a roof proof, elevator change. The long-tern repair plan provides the repair time and repair rate according to various construction types. Most of the management agent apply the repair standard into the field area. But the repair time could not reflect the present condition and bring into the wrong maintenance. Therefore, the repair time for the long-term maintenance plan would be revised and reflected from the material and technology development. |n this study, it aimed at improvement for the repair time in various construction types which are provided in the long-term repair plan. For this, the 22 management agents are surveyed directly. This study shows that the repair time of the painting are correspondent to the repair time of the long-term plan irregardless of the painting materials. Most of other areas would correspondently similar to the long-term plan. This study could not include the building location, material and other haracteristics. Therefore, the further study would be needed to reflect the building and materials attributes to get the detailed repair time.

A Study for selecting the Highway Sites' Best Management Practice for Nonpoint Source Pollution (고속도로 현장별 비점오염 저감시설 선정방안 연구)

  • Lee, Yong-Bok;Choi, Sang-Il;Park, Kye-Su;Seong, Il-Jong;Jung, Sun-Kook
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.857-866
    • /
    • 2011
  • This research categorized EIA target highways into following three types in order to minimize non-point source pollution from highway runoff. 1. Big drainage basin. 2. Small drainage basin. 3. Bridge section. The Natural, Filter and Swirl-Type devices were evaluated in terms of removal efficiency of TSS, BOD, COD, T-N, T-P, compatibility of site selection, economic feasibility, and maintenance convenience through which the final BMP was selected. According to the removal efficiency result, the area of Big and Small Drainage basin and bridge section had higher removal efficiency with natural facility than that of the Filter or Swirl-Type device. To make appropriate selection of highways'BMP for non-point source pollution, this study will aim to contribute to building more environmentally friendly highways by proposing the selection process that is made of 5 stages. 1. Selecting the target drainage basin. 2. Selecting the land for the mitigation facility. 3. Analysing the ease of maintenance. 4. Technically evaluating each installation. 5. Evaluating the effective implementation methods.

An Experimental Study on the Fatigue Behavior of H & Channel-Type Lining Board (H형 복공판과 Channel형 복공판의 피로거동에 관한 실험적 연구)

  • Lee, Seung-Soo;Kim, Doo-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.4
    • /
    • pp.209-216
    • /
    • 2005
  • The objective of this paper is to investigate the H & Channel type lining board's capacity by using the fatigue test. The accumulated test result will be used to analyze the relation between the cause of crack occurrence and the behavior of structure. H type lining boards was comfortable behaved in over one million recycled. loading test. In case of channel type lining board specimens occurred the fatigue fracture in about one hundred thousand recycled loading test, and then could not secured endurance life that used servicing load.

Determinants of Residential Satisfaction and Attachment According to the Urban Multi-family Dwelling Types (도시형 생활주택의 유형별 거주만족도 및 거주애착에 미치는 영향요인에 관한 연구)

  • Hong, Keong-Gu
    • Journal of the Korean housing association
    • /
    • v.24 no.3
    • /
    • pp.73-83
    • /
    • 2013
  • The aim of this paper is to examine the determinants of residential satisfaction and attachment according to the urban multi-family dwelling types. On the basis of the surveys, the factor analysis and regression are employed as the empirical analysis on residential satisfaction and attachment in Daegu metropolitan city. The major findings are as follows; First, as for post-occupancy evaluation of residential environment of building and outside, the residents of complex type of multi-family housing satisfied with most of items more than studio type except the location, amenity facilities around building and utilities fee. Second, about the Residential Satisfaction and Attachment by types, the residents of complex type of multi-family housing satisfied with most of items more than studio type too. Third, the determinants in residential Satisfaction of complex types are 'welfare and amenity facilities factor', 'maintenance factor' and 'location factor'. On the other hand, the determinants in residents of studio type are 'inexpensive rent fee factor', 'welfare and amenity facilities factor' and 'maintenance factor'. Going forward, this research will help us better understand residential satisfaction from the point of residents and find new ways to improve resident satisfaction and attachment.

Structural Behavior of the RC Column-Steel Beam Joint with Band Plate (Band Plate로 연결된 RC기둥-철골보 접합부의 이력거동에 관한 실험연구)

  • Seo, S.Y.;Yi, W.H.;Lee, L.H.;Yoon, S.J.
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.1
    • /
    • pp.213-221
    • /
    • 2002
  • This paper presents the experimental result of Reinforced Concrete column-steel beam joint connected by Band Plates(BP). Main parameters in the test are the shape of BP and thickness of plate. Ten interior and exterior RC column-steel beam joint specimens are designed. Cyclic loads are applied to the beam end of eight specimens (four interior specimens and four exterior specimens). To evaluate the cyclic effect, monotonic loads are acted for two specimens. All specimen showed similar failure pattern such as the plate of BP get torn after the large deformation. Even though the specimen with double cross type BP has lower strength than the specimen with single cross type BP, the energy dissipation capacity of the specimen turned out high. Thus, provided the strength of joint with double cross type to be designed to have suitable strength by increasing the thickness of plate, the joint system may show higher seismic capacity.