• 제목/요약/키워드: maintenance standard materials

검색결과 115건 처리시간 0.025초

Empirical Equations for the Analysis of the Time Dependence of the Luminance Properties of LCD Panels and Backlights for TV Applications

  • Ryu, Jin-Sun;Kim, Su-Jin;Park, Seung-Mi;Ko, Jea-Hyeon
    • Journal of Information Display
    • /
    • 제11권2호
    • /
    • pp.39-44
    • /
    • 2010
  • The time dependences of the luminance properties of 55-inch CCFL and LED backlights and 32-inch FFL backlights with LCD panels were investigated during the warm-up time from the cold start. The long-term luminance maintenance curve of a standard CCFL was examined in a time window up to 5000 hours. These two time dependences are important characteristics from the viewpoint of initial picture quality and lifetime reliability, respectively. Empirical equations were suggested for the analysis of the time dependence of these luminance data. These approaches are expected to be helpful in predicting the luminance properties of backlights based on the luminance data obtained in a limited time window.

지하 콘크리트 구조물에 적용되는 에폭시 수지계 주입형 누수보수재료의 화학저항성능 평가 (Evaluation of Chemical Resistance of Epoxy Resin Injection Type Leakage Repairing Materials Applied to Underground Concrete Structures)

  • 박소영;김수연;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.41-42
    • /
    • 2017
  • In this study, an investigation was made to study the chemical resistance performance of epoxy resin injection type leakage repair material used in the Korean construction market in accordance to the test method outlined in "ISO TS 16774, Part 2; Test Method for Chemical Resistance." This is a new standard document used for quality control method of injection type repair material used for leakage cracking of underground concrete structures. The results of this study can be expected to be utilized as reference data that can be used for quality improvement of the maintenance methods for future construction.

  • PDF

Reduction of Heat Generation from Junction Box in 3 kW Photovoltaic Power Generation System

  • Yun, Jung-Hyun;Sun, Ki-Ju;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권1호
    • /
    • pp.21-24
    • /
    • 2016
  • A junction box used in a 3 kW photovoltaic power generation system plays a role in collecting and supplying the direct current voltage produced by photovoltaic modules to an inverter. It is also used for facilitating maintenance checks and protecting the module and inverter by keeping the voltage constant. As for the junction box, using it in a parallel connection creates a difference between the setup modules. In order to compensate, an inverse voltage diode is used. But the high-power created through the solar generator can be delivered to the inverter through the inverter regularly. Therefore, a component can break down due to excess heat. And consequently short circuits and electric leakage occurs. In this study, using a junction box that enabled the bypass of high electric power, it was possible to reduce heat generation by approximately 35℃ when compared to a standard junction box.

건축기준 완화를 위한 순환골재 콘크리트 적용 시의 품질 특성 연구 (A Study on the Quality Properties When Applying Recycled Aggregate Concrete for the Construction Standard Mitigation)

  • 우경섭;김정호;이세현;오중근
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권3호
    • /
    • pp.63-69
    • /
    • 2020
  • 우리나라는 전체 폐기물 발생량 중 건설폐기물 발생량은 약 47.3%로 가장 많은 비중을 차지하고 있고 그 중 폐콘크리트가 약 62.8%로 재활용이 시급한 상황이다. 이에 정부는 건설폐기물의 재활용을 촉진하기 위해 순환골재의 다양하고 폭넓은 활용을 권장하고 있다. 또한 건축물에 콘크리트용 순환골재를 사용할 경우 용적률, 건축높이 등 건축기준을 완화해주고 있다. 그 기준은 콘크리트용 순환골재 최대 25% 사용 시 용적률을 최대 15% 완화해 주는 조건이다. 이에 본 연구는 순환골재의 콘크리트용으로의 사용을 적극 권장하고자 콘크리트용 순환골재 사용 시 건축기준의 완화 내용을 검토하였고 순환골재 중 순환굵은골재을 사용하여 치환율에 따른 배치플랜트에서의 적정 혼합시간을 도출하였다. 또한 건조수축 개선을 위해 순환골재용 혼화제를 사용하여 순환굵은골재 치환율별 콘크리트의 물리, 역학적 특성에 대해 비교 분석하여 건조수축 개선 효과를 나타내어 향후 현장에 안정적으로 적용이 가능할 것으로 판단된다.

유실저항성 시험방법을 이용한 유속조건에서의 질량변화 추이 연구 합성고무계 보수재료를 중심으로- (A Study on the Change of Mass in Flow Velocity Using Loss Resistane Test Method - Using Synthetic rubber system Repair material -)

  • 박소영;장보;김수연;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.127-128
    • /
    • 2017
  • Tests are conducted according to the ISO TS 16774, Part 3 standard for quality management of leakage repair materials used in cracks in underground concrete structures. These test methods are performed indirectly using a nonwoven fabric on a chalet containing leak repair materials. However, it is considered that it is appropriate to verify the resistance of the repair material, which is required to be applied directly to the cracks in the actual field and to exhibit the resistance of the flow velocity. In this study, mass change was measured by using nonwoven fabric and nonwoven fabric. As a result, both methods showed an increase in mass, which indicated that the maintenance material itself contained a large amount of water, and that the mass change occurred depending on the drying state. Also, depending on the use of nonwoven fabric, the error due to the indirect test could not be ruled out. Therefore, further verification is needed, and it is considered that the test for change of mass reduction measurement is necessary according to the drying time of other types of the same series.

  • PDF

Advanced Indentation Studies on the Effects of Hydrogen Attack on Tensile Property Degradation of Heat-Resistant Steel Heat-Affected Zones

  • Choi, Yeol;Jang, Jae-il;Lee, Yun-Hee;Kwon, Dongil;Kim, Jeong-Tae
    • Corrosion Science and Technology
    • /
    • 제2권6호
    • /
    • pp.266-271
    • /
    • 2003
  • Safety diagnosis of various structural components and facilities is indispensable for preventing catastrophic failure of material by time-dependent and environment accelerating degradation. Also, this diagnosis of operating components should be done periodically for safe maintenance and economical repair. However, conventional standard methods for mechanical properties have the problems of bulky specimen, destructive procedure and complex procedure of specimen sampling. So, a non-destructive and simple mechanical testing method using small specimen is needed. Therefore, an advanced indentation technique was developed as a potential method for non-destructive testing of in-field structures. This technique measures indentation load-depth curve during indentation and analyzes the mechanical properties related to deformation such as yield strength, tensile strength and work-hardening index. In this paper, we characterized the tensile properties including yield and tensile strengths of the V-modified Cr-Mo steels in petro-chemical and thermo-electrical plants. And also, the effects of hydrogen-assisted degradation of the V-modified Cr-Mo steels were analyzed in terms of work-hardening index and yield ratio.

교면 덧씌우기 콘크리트의 인발부착강도(引拔附着强度) 시험법(試驗法) 제안(提案) (Proposal of Concrete Pull Off Bond Strength Measurement Method for Bridge Deck Overlay)

  • 김성환;김동호;김현오;이봉학
    • 산업기술연구
    • /
    • 제23권A호
    • /
    • pp.149-156
    • /
    • 2003
  • The development and maintenance of a sound bond are essential requirements of concrete repair and replacement. The bond property of a overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials, but no test method has been adopted as a standard. In this study, a concrete pull off bond strength measurement method for field application is proposed and evaluated. This study compares the splitting tensile test, slant shear test, nipple pipe direct tensile test, flexural adhesion test, briquette tensile test, jumbo nail pull-out test and core pull-off test with their test procedures. From these comparison and investigation, core pull-off test is selected as a main topic of this study because of it's suitability for in situ testing, simplicities in field application and clearness at interface boundary condition. Thus, the proposed core pull off test is evaluated to be the most appropriate method for field application in a simple manner. The fracture surface and fracture mode could be easily determined by visual observation of failure surface of the field specimen. The core pull off test was found to be sensitive to surface condition and latex contents at latex modified concrete.

  • PDF

시약 변경 시 모집단 분포 추이에 따른 결과 분석 (Result Analysis according to Population Distribution Trends when Reagents are Changed)

  • 박혜미;임수연;유선희;이선호
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.55-61
    • /
    • 2023
  • Purpose In this study, the monthly population distribution was calculated for statistical verification of 10 tests (CA19-9, CA15-3, testosterone, PTH, calcitonin, AFP, CEA, CA72-4, PSA, estradiol) with changed reagents, and the trend of change By comparing and analyzing the results, we want to verify the accuracy of the results and improve the reliability of the test. Materials and Methods From June 2021 to February 2023, for the 10 items in which the reagent was changed, the monthly percentage and standard deviation index before and after the reagent change were compared, respectively. At this time, the reference value was arbitrarily set for the comparison group in consideration of the reference value of the test item, and the groups were subdivided and compared, and the standard deviation index allowed range was -2.0 or more and 2.0 or less. Results For CA19-9, CA15-3, AFP, CEA, and calcitonin 5 test items, the change in monthly ratio in all test sections before and after the reagent change was kept constant. On the other hand, for CA72-4, PSA, testosterone, PTH, and estradiol items, the standard deviation index exceeded the acceptable standard after changing the reagent. CA72-4 test items showed an increasing trend in standard deviation index in the test section exceeding the reference value. In the case of the PSA test item, the maintenance ratio of 0.04 ng/mL was significantly decreased after changing the reagent. The testosterone test item had a standard deviation index of -2.5 in the test section exceeding 10.1 ng/mL after changing the reagent, and the standard deviation index of the PTH test item was out of the acceptable range in all test sections. It was confirmed that the estradiol test item showed an overall increase in the result value. Conclusion Through this study, the continuity and accuracy of the test results could be verified. It is considered that the stability of the test can be secured by analyzing the factors affecting the test result and solving the cause for the test item whose standard deviation index is out of the acceptable standard.

  • PDF

『임원경제지』 「섬용지」와 문화재수리 표준시방서를 통해 본 전통조경공간 설계 시공방법 (A Study on the Design & Construction Method of Traditional Landscape Space through the 『Imwongyeongjeji』 「Seomyongji」 and the 'Standard Specification for Repairing Cultural Heritages')

  • 이정한
    • 한국전통조경학회지
    • /
    • 제37권4호
    • /
    • pp.1-10
    • /
    • 2019
  • 본 연구는 과거 전통조경공간의 설계 및 시공과 오늘날 이를 유지 계승하기 위한 문화재수리 및 정비 등의 시공방법을 임원경제지 섬용지와 문화재수리 표준시방서를 토대로 서술방식, 전통조경 분야 관련 공정 추출, 시공방법을 상호 비교하였으며, 그 결과는 다음과 같다. 첫째, 임원경제지 섬용지와 문화재수리 표준시방서의 서술방식 및 전통조경 분야 관련 공정을 살펴본 결과 임원경제지 섬용지는 생활공간 전반의 시공방법을 집대성한 백과사전서로 구성요소별 시공방법의 사용처, 효과, 장·단점을 서술하고 구체적인 수치를 제시하여 전통조경공간 시공의 제도의 보급을 목적으로 삼았다. 문화재수리 표준시방서는 문화재 수리의 공정 전반을 제시하였으며, 문화재 수리 현장에서 참고할 수 있는 일종의 지침서 역할을 하고 있다. 이중 기초공사, 지붕공사, 조경공사, 담장공사 등이 전통조경분야에 적용될 수 있는 주요 항목으로 도출되었다. 둘째, 전통조경공간 시공방법을 기초공사와 지붕공사, 조경공사, 담장공사 등의 공정으로 구분하여 분석해보면, 기초공사는 지반을 다지는 과정을 반복하는 방식이다. 지붕공사 중 기와지붕 조성은 서까래 위에 산자를 설치하고 기와를 쌓았으며, 초가지붕은 볏짚을 여러 다발로 묶어 차례로 지붕을 덮었다. 석판지붕은 기와 대신 얇고 넓은 돌을 사용하였으며, 너와지붕은 나무판자를, 굴피지붕은 건조시킨 굴피를 여러 겹으로 깔아 조성하였다. 조경공사는 주로 잡석다짐을 통한 포장기법과 여러 단을 조성하고 상부에 석물이나 화초나 관목 등을 식재하는 화계 시공이 주를 이루고 있고 담장공사는 쌓는 재료에 따라 흙을 다져 쌓은 토담, 돌과 진흙을 사용한 돌담, 기와로 무늬를 만든 영롱담, 널판을 벽면으로 사용하는 판장 시공 등이 도출되었다. 셋째, 임원경제지 섬용지와 문화재수리 표준시방서의 시공방법을 비교해보면, 임원경제지 섬용지는 전통공간의 신규 조성을 위한 시공방법의 표준화에 중점을 두고, 문화재수리 표준시방서는 문화재 수리 현장의 다양성을 고려한 전반적인 시공 절차를 제공하여 시공의 범위 설정에 차이가 있다. 또한 과거 전통조경공간은 일상거주공간이었으나 오늘날에는 문화재로 지정된 곳으로서 기 구축된 시설의 유지관리 공정이 이루어지며, 관람환경 조성을 위한 시공방법이 추가되었다. 전통지식의 계승 차원에서 과거의 시공방식은 오늘날 문화재 수리에도 일정 부분 유사한 방법들이 확인되며, 일부 소재나 배합방식, 후대 추가된 시설의 구분, 효율적인 시공방식의 도입 등 전통기술을 재구성한 사례도 확인되었다.

자철석 혼입 모르터의 기초물성 연구 (Preliminary Tests of Mortars Containing Magnetite as Fine Aggregate)

  • 윤상천;양성철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권3호
    • /
    • pp.82-88
    • /
    • 2013
  • 본 연구에서는 원적외선의 방출을 증진시켜 쾌적한 실내 환경을 조성시키며 아울러 비중이 높은 재료를 사용하여 층간소음을 저감시키기 위한 방안으로서 건축용 친환경 바닥 마감재에 자철석 잔골재를 사용하는 모르터의 기초물성 연구를 수행하였다. 실험에 사용된 모르터의 배합은 자철석 잔골재를 자연사로 0, 20, 40, 60, 100% 치환하였다. 먼저 원적외선 방출성능으로서 방사율과 방사에너지를 측정하여 KICM의 기준을 훨씬 상회하는 결과를 얻었다. 단위용적질량 압축강도 실험결과 치환율이 증가함에 따라 선형적으로 증가하는 결과를 얻었다. 그러나 건조수축 시험결과 자철석 잔골재의 치환율이 증가함에 따라 건조수축 변화율이 기준 시험체 대비 급격하게 증가하는 것으로 나타나 향후 이를 해결하기 위한 방안이 강구되어야 함을 알 수 있었다.