• 제목/요약/키워드: maintenance dose

검색결과 169건 처리시간 0.023초

급곡선 궤도에서 속도제한표 적정위치 (A Study on the Location of Speed Limit Post of Curved Track)

  • 이기승;이종수;김성호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 춘계학술대회 논문집
    • /
    • pp.289-294
    • /
    • 2001
  • A curved track needs balanced super elevation according to the speed of the passing train and it is limited by maximum allowable amount. Therefore, passing speed at high degree curved track has to be controlled below the limits. Accurate position of the Speed Limit Post(SLP), which shows allowable speed of curved track dose not regulated so design and line side maintenance engineer adopt the position differently, When the rate of cant deficiency is considered on transition-curved section, the SLP should be located at the beginning point of the transition curve so as to control the speed of passing train and it will increase ride quality to passenger.

  • PDF

X선영상증배관의 상대변환계수 측정에 관한 검토 (The Study on Measurement of Relative Conversion Factor in X-ray Image Intensifier)

  • 김성철;신성일;이선숙;허준;김성수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.28-33
    • /
    • 1997
  • For the Evaluation of X-ray image intensifier, we measured radiation dose at input of I. I., brightness and fluorescence at output of I. I. by using X-ray exposure meter, optometer and fluorescence meter for the relative conversion factor. Especially, by using fluorescence meter, we could easily get relative conversion factor without having regulated machine by JIS. Since using, the quality of image intensifier is going down. Consequently, it needs continuous quality maintenance.

  • PDF

Theoretical study of cross sections of proton-induced reactions on cobalt

  • Yigit, Mustafa
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.411-415
    • /
    • 2018
  • Nuclear fusion may be among the strongest sustainable ways to replace fossil fuels because it does not contribute to acid rain or global warming. In this context, activated cobalt materials in corrosion products for fusion energy are significant in determination of dose levels during maintenance after a coolant leak in a nuclear fusion reactor. Therefore, cross-section studies on cobalt material are very important for fusion reactor design. In this article, the excitation functions of some nuclear reaction channels induced by proton particles on $^{59}Co$ structural material were predicted using different models. The nuclear level densities were calculated using different choices of available level density models in ALICE/ASH code. Finally, the newly calculated cross sections for the investigated nuclear reactions are compared with the experimental values and TENDL data based on TALYS nuclear code.

Principles and Applications of Non-Thermal Technologies for Meat Decontamination

  • Yewon Lee;Yohan Yoon
    • 한국축산식품학회지
    • /
    • 제44권1호
    • /
    • pp.19-38
    • /
    • 2024
  • Meat contains high-value protein compounds that might degrade as a result of oxidation and microbial contamination. Additionally, various pathogenic and spoilage microorganisms can grow in meat. Moreover, contamination with pathogenic microorganisms above the infectious dose has caused foodborne illness outbreaks. To decrease the microbial population, traditional meat preservation methods such as thermal treatment and chemical disinfectants are used, but it may have limitations for the maintenance of meat quality or the consumers acceptance. Thus, non-thermal technologies (e.g., high-pressure processing, pulsed electric field, non-thermal plasma, pulsed light, supercritical carbon dioxide technology, ozone, irradiation, ultraviolet light, and ultrasound) have emerged to improve the shelf life and meat safety. Non-thermal technologies are becoming increasingly important because of their advantages in maintaining low temperature, meat nutrition, and short processing time. Especially, pulsed light and pulsed electric field treatment induce few sensory and physiological changes in high fat and protein meat products, making them suitable for the application. Many research results showed that these non-thermal technologies may keep meat fresh and maintain heat-sensitive elements in meat products.

전자선 검역처리선량이 파프리카의 품질 및 관능특성에 미치는 영향 (Effects of quarantine doses of e-beam irradiation on the physicochemical and sensory characteristics of paprika)

  • 박윤지;조윤희;권중호
    • 한국식품과학회지
    • /
    • 제49권2호
    • /
    • pp.117-122
    • /
    • 2017
  • 신선 채소인 파프리카에 검역처리 선량의 전자선 처리(0, 0.4, 1, 2 kGy) 후 냉장저장 40일 동안 미생물학적, 이화학적 및 관능적 품질을 평가하였다. 파프리카의 미생물 농도는 총세균, 효모 및 곰팡이의 경우 $10^4CFU/g$, 대장균군은 $10^2CFU/g$ 수준이었고, 1 kGy 선량은 미생물 농도를 1 log cycle 감소시킬 수 있었다. 중량감소율은 조사처리에 따른 차이를 보이지 않았고, 경도와 카로티노이드 함량은 조사 직후 1 kGy 이상의 선량에서 유의적으로 감소하였으며, 저장 중에도 선량에 관계없이 감소하였다. 비타민 C 함량은 선량에 따른 유의적인 차이를 보이지 않았고, 0, 0.4 및 1 kGy 처리 시료는 저장 40일째 저장 초기 함량의 87-90% 수준으로 감소하였다. 파프리카에 대한 관능평가 결과, 2 kGy 수준의 전자선 처리는 색과 조직감 저하에 영향을 미치는 것으로 확인되었다. 이상의 결과, 수출용 파프리카의 해충구제 및 검역처리를 위한 0.4-1 kGy 수준의 전자선 처리는 냉장저장 동안 미생물학적 안전성을 확보하면서 이화학적 품질을 유지시키는 것으로 확인되었다.

흰쥐 해마 CA1 영역에서 H2O2에 의한 장기강화 억제에 대한 발효황금 추출물의 효과 (Effects of Fermented Scutellaria Baicalensis Extract on H2O2 - Induced Impairment of Long-term Potentiation in Hippocampal CA1 Area of Rats)

  • 허준호;;김민선
    • 동의생리병리학회지
    • /
    • 제33권6호
    • /
    • pp.356-362
    • /
    • 2019
  • Scutellaria baicalensis (SB) has widely used in the treatment for various brain diseases in the field of Oriental medicine. Biofermantation of SB can make major chemical constituents of SB to pass blood-brain barrier easily and to have more potent anti-oxidant ability. There is a little information about the contribution of fermented SB (FSB) to the formation or maintenance of the neural plasticity in the hippocampus. The purpose of this study was to evaluate effects of FSB extract on hydrogen peroxide (H2O2) - induced impairments of the induction and maintenance of long-term potentiation (LTP), an electrophysiological marker for the neural plasticity in the hippocampus. From hippocampal slices of rats, the field excitatory postsynaptic potentials (fEPSPs) were evoked by the electrical stimulation to the Schaffer collaterals - commissural fibers in the CA1 areas and LTP by theta-burst stimulation by using 64 - channels in vitro multi-extracellular recording system. In order to induce oxidative stress to hippocampal slices two different concentrations (200, 400 μM) of H2O2 were given to the perfused aCSF before and after the LTP induction, respectively. The ethanol extract of FBS with concentration of 25 ㎍/ml, 50 ㎍/ml was diluted in perfused aCSF that had 200 μM H2O2, respectively. Oxidative stress by the treatment of H2O2 resulted in decrease of the induction rate of LTP in the CA1 area with a dose - dependent manner. However, the ethanol extract of FSB prevented the reduction of the induction rate of LTP caused by H2O2 - induced oxidative stress with a dose - dependent manner. These results may support a potential application of FSB to ameliorate impairments of hippocampal dependent neural plasticity or memory caused by oxidative stress.

Effect of remifentanil on intraoperative fluid balance: a retrospective statistical examination of factors contributing to fluid balance

  • Ohara, Sayaka;Nishimura, Akiko;Tachikawa, Satoshi;Iijima, Takehiko
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권3호
    • /
    • pp.129-135
    • /
    • 2020
  • Background: Postoperative fluid retention is a factor that causes delay in recovery and unexpected adverse events. It is important to prevent intraoperative fluid retention, which is putatively caused by intraoperative release of stress hormones, such as ADH (anti-diuretic hormone) or others. We hypothesized that intraoperative analgesia may prevent pathological fluid retention. We retrospectively explored the relationship between analgesics and in-out balance in surgical patients from anesthesia records. Methods: Anesthetic records of 80 patients who had undergone orthognathic surgery were checked in this study. Patients were anesthetized with either TIVA (propofol and remifentanil) or inhalational anesthesia (sevoflurane and remifentanil). During surgery, acetated Ringer's solution was infused for maintenance at a rate of 3-5 ml/kg/h at the discretion of the anesthetist. The perioperative parameters, including the amount of crystalloid and colloid infused, and the amount of urine and bleeding were checked. Furthermore, we checked the amount and administration rate of remifentanil during the surgical procedure. The correlation coefficient between the remifentanil dose and the in-out balance or the urinary output was analyzed using the Pearson correlation coefficient. The contributing factor to fluid retention, including urinary output, was statistically examined by means of multivariate logistic regression analysis. Results: A significant positive correlation was found between remifentanil dose and urinary output. Urinary output less than 0.04 ml/kg/min was suggested to cause positive fluid balance. Although in-out balance approaches zero balance with increase in remifentanil administration rate, no contributing factor for near-zero fluid balance was statistically picked up. The remifentanil administration rate was statistically picked up as the significant factor for higher urinary output (> 0.04 ml/kg/min) (OR, 2,644; 95% CI, 3.2-2.2 × 106) among perioperative parameters. Conclusions: In conclusion, remifentanil contributes in maintaining the urinary output during general anesthesia. Although further prospective study is needed to confirm this hypothesis, it was suggested that fluid retention could be avoided through suppressing intraoperative stress response by means of appropriate maintenance of remifentanil infusion rate.

Morphine과 Buprenorphine의 지속적 정주에 의한 술후 통증 억제효과의 비교 (Effects of Morphine and Buprenorphine Intravenous Infusion for Postoperative Pain)

  • 백선기;소상윤;한영진;최훈
    • The Korean Journal of Pain
    • /
    • 제7권1호
    • /
    • pp.78-83
    • /
    • 1994
  • 수술후 통증치료에 morphine과 buprenorphine의 효과를 알아보기 위하여 morphine과 buprenorphinec을 단독 투여하거나(1, 2군) buprenorphine과 ketorolac을 반량씩 혼합하여 지속적으로 정주(3군)하여 다음과 같은 결과를 얻었다. 1) 각군에서 모두 혈압과 맥박의 의의있는 변화는 초래하지 않았다. 2) Visual analogue scale으로 평가한 진통 발현은 각군에서 모두 비슷하였다. 3) Visual analogue scale과 Prince Henry Scale로 평가한 진통효과는 morphine군에서 가장 우수하였고, buprenorphine군과 buprenorphine+ketorolac의 반량 투여군에서는 비슷하였다. 4) 부작용의 발생은 1군과 2군에서 비슷하였으나 3군에서 가장 낮았다. 이상의 결과로 보아 지속적 정주에 의한 술후 통증의 억제에 있어서 buprenorphine은 morphine을 대치할 수는 있으나 morphine보다 우수하지는 못한 것으로 사료되며, buprenorphine 사용시는 ketorolac을 병용하여 사용량을 줄염으로써 부작용을 줄일 수 있을 것으로 사료된다.

  • PDF

TOMO 치료 시 체온 유지를 위한 물질 사용에 따른 조직 내 선량 변화 평가 (In Tomotherapy, for the Maintenance of Body Temperature due to Substance Use, Changes in Dose Assessment in the Organization)

  • 황재웅;정도형;김대웅;양진호;최계숙
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.131-134
    • /
    • 2010
  • 목 적: TOMO 치료는 일반 방사선 치료와 달리 상대적으로 긴 Beam time과 온도에 민감한 CT 검출기 등으로 치료실 내 적정온도($20{\sim}21^{\circ}$)를 유지하기 위하여 자체 Cooling system 이외에도 항온 항습기를 작동시키고 있다. 이로 인해 TOMO 치료실 내 온도가 저하되어 환자들의 체온 유지를 위해서 치료 부위에 이불 등을 덮어준다. 따라서 이러한 물질들이 조직 내 선량에 어떠한 변화를 주는지 알아보고자 한다. 대상 및 방법: 조직 내 선량변화를 비교하기 위하여 치즈팬텀(Cheese Phantom)을 사용하였고, CT-simulation 촬영 후 치즈팬텀의 중심점을 PTV (Planning Target Volume, 치료계획 표적 용적)로 설정하여 Daily dose 200 cGy, 3회의 치료계획을 세웠다. PTV, PTV+7 cm, PTV+14 cm, 총 세지점에서 Ion chamber를 사용하여 팬텀에 아무 물질도 덮지 않은 상태에서 선량을 측정하고, 치료 중 가장 많이 사용하는 이불을 포함한 빈번하게 사용하는 4가지 물질(방포 0.8 mm, 가운 1.4 mm, 담요 3.3 mm, 이불 13.7 mm)을 팬텀에 덮었을 때의 선량을 동일한 위치에서 각각 3회 측정하여 비교 분석하였다. 결 과: PTV, PTV+7 cm, PTV+14 cm 지점에서 아무물질도 덮지 않은 상태에서 측정한 결과와 4가지 물질(방포, 가운, 담요, 이불)을 덮은 상태에서 측정한 결과를 비교해본 결과, PTV에서 각각 -0.17%, -0.44%, -0.53%, -0.9% 변화하였고, PTV+7 cm에서 각각 -0.04%, +0.07%, +0.06%, +0.07% 변화하였고, PTV+14 cm에서 각각 0%, -0.06%, -0.02%, +0.6% 변화하였다. 결 론: 본 실험 결과 TOMO 치료 시 환자들의 체온 유지를 위하여 사용하는 물질에 의해 PTV에서는 물질의 두께에 비례하여 감소하는 것으로 나타났다. 그러나 PTV+7 cm 지점에서는 미세한 변화를 보였고, PTV+14 cm 지점에서 선량은 조금 증가하는 것으로 나타났다. 세지점 모두 그 차이가 치료 허용오차 범위인 ${\pm}3%$로 안에 들어오는 것으로 확인이 되어 치료효과에는 큰 영향을 미치지 않을 것으로 사료된다.

  • PDF

렉셀 감마플랜(LGP)에서 추출된 선량 분포와 가변 타원체 모형화기술(VEMT)에 의해 계산된 선량 분포 사이의 비교 (Comparisons between the Two Dose Profiles Extracted from Leksell GammaPlan and Calculated by Variable Ellipsoid Modeling Technique)

  • 허병익
    • 한국방사선학회논문지
    • /
    • 제11권1호
    • /
    • pp.9-17
    • /
    • 2017
  • 감마나이프 방사선수술(GKRS)의 높은 정밀도와 정확성은 치료 성공을 위한 기본 요건이다. 방사선의 급격한 감소와 함께 정교한 방사선 전달 및 선량 기울기가 임상적으로 적용되어야 하므로 방사선량 측정 및 기하학적 정확성을 보장하고 감마나이프 방사선수술에서 발생할 수 있는 모든 위험 요인을 줄이기 위해서는 전용 정도관리(QA) 프로그램이 필요하다. 본 연구에서는 독립적인 검증 프로그램 가변 타원체 모형화기술(Variable Ellipsoid Modeling Technique: VEMT)을 적용해서 감마나이프 치료계획 시스템 렉셀 감마플랜의 알고리즘에 사용된 단일 샷 선량 분포의 정확성을 검증하였다. 감마나이프 퍼펙션(PFX)에 장착한 직경 160 mm의 구형 ABC 팬텀에 조사한 단일 샷의 선량 분포를 평가했다. 단일 샷의 조사는 ABC 팬텀의 중심으로 향하게 하여 x, y 및 z 축을 따라 4, 8 및 16 mm 크기의 시준기 배치가 고려되었다. 감마나이프 방사선수술에서 사용되는 감마나이프 퍼펙션 치료계획 시스템은 렉셀 감마플랜(LGP) 버전 10.1.1이 사용되었다. VEMT의 검증을 통해서 감마나이프 방사선수술의 정확성은 배가 될 것이다. 그래서 VEMT 검증 후 감마나이프 방사선수술의 정확성과 정밀성을 토대로 임상 적용이 최종적으로 수행되어야 한다. 특히 환자의 머리가 직경 160mm의 구형으로 시뮬레이션된 조건에서 50% 등선량 높이 수준의 너비, 즉 최대반값폭(FWHM)이 검토되었다. VEMT를 통해 예측된 x, y, z 축의 선량 분포에 관한 모든 데이터는 4 mm 및 8 mm 시준기 배치에 대해 z 축을 따라 최대반값폭과 반그늘(PENUMBRA)의 약간의 차이점을 제외하고는 사양 내(등선량 50%에서 1 mm 이내)에서 LGP의 선량 분포와 훌륭하게 일치했다. 최대반값폭의 최대 불일치는 모든 시준기 배치에서 2.3% 미만이었다. 반그늘의 최대 불일치는 z 축을 따라 8 mm 시준기에 대해서 0.07 mm로 주어졌다. VEMT와 LGP로 얻은 선량 분포에서 최대반값폭과 반그늘의 차이는 감마나이프 방사선수술에서 임상적 유의성을 부여하기에는 너무 작았다. 이 연구의 결과는 전 세계 감마나이프 방사선수술에 관련된 의학물리학자를 위한 참고 자료로 활용될 수 있으리라 사료된다. 따라서 우리는 LGP의 결과물에 대한 독립적인 검증방법 VEMT를 포함하는 정기 예방정비 프로그램을 통해 결정된 모든 시준기 배치에 대한 선량 분포의 유효성을 확인하고 감마나이프 방사선수술 환자에게 임상적으로 완벽한 치료를 보장할 수 있다. 그래서 VEMT의 활용은 시스템을 안전하게 검증하고 운영할 수 있는 정도관리의 한 부분이 될 것으로 기대한다.