• Title/Summary/Keyword: maintainer

Search Result 67, Processing Time 0.019 seconds

Influence of Band and Loop Type Space Maintainer on Intraoral Scanning Accuracy of an Adjacent Tooth

  • Ju Ri Ye;Yong Kwon Chae;Ko Eun Lee;Hyo-Seol Lee;Sung Chul Choi;Ok Hyung Nam
    • Journal of Korean Dental Science
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2023
  • Purpose: The purpose of this study was to evaluate whether the presence of a space maintainer affects the accuracy of an intraoral scanner. Materials and Methods: The maxillary primary first molar typodont tooth was removed from the primary dentition typodont model and a band and loop type space maintainer was delivered. After the model was connected to a dental phantom, intraoral scan was performed using TRIOS 4 (3Shape A/S, Copenhagen, Denmark). The scan was repeated with the same technique without the space maintainer. Each scan was performed 10 times. All scan files into a GOM inspect 2018 software and evaluated the accuracy. The accuracy was evaluated on trueness and precision, and calculated using the root mean square value. Result: When there was a space maintainer in the oral cavity, the trueness value was 0.10±0.02 mm and the precision value was 0.15±0.03 mm. In the absence of the space maintainer, the trueness value was 0.12±0.03 mm and the precision value was 0.16±0.04 mm. There were no significant differences depending on the presence of a space maintainer (P>0.05). Conclusion: Within the limits of this study, the accuracy of the intraoral scanner was not influenced by the presence of space maintainer.

Space maintainer using CAD/CAM system without a band: a case report (CAD/CAM 시스템을 이용하여 band 없이 공간유지 장치를 제작한 증례)

  • Eun-Sook Kang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.100-106
    • /
    • 2024
  • Early interceptive orthodontic interventions are often started in the developing dentition to guide normal occlusion. The simplest way to prevent eruption failure from deciduous tooth loss is to fix a space maintainer such as a band and loop. Band and loop space maintainer has several problems like cement loss, demineralization, locking of the adjacent tooth, and needs to take a pickup impression of the band. Computer-assisted design/computer-assisted manufacturing (CAD/CAM) space maintainer without band was developed to solve these problems. This case report describes successful eruption of the mandibular second premolar using CAD/CAM without a band.

EFFECTS OF FIXED SPACE MAINTAINER AFTER MISSING OF ANTERIOR TEETH (상악 유전치 조기상실시 고정성 공간유지장치의 효과)

  • Hwang, Dong-Hwan;Choi, Byung-Jai;Choi, Hyung-Jun;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.1
    • /
    • pp.186-194
    • /
    • 1997
  • The three child patients aged 3 to 5 years were worn by anterior space maintainer which are fixed type after missing of anterior teeth due to nursing caries, and were taken periodic follow check up. The results are : 1. At missing of anterior teeth, fixed space maintainer can be used. 2. Increased esthetic satisfaction and positive change of social behavior can be observed by these child patients. 3. Some phonations can be changed definitely after wearing the fixed space maintainer.

  • PDF

DESIGN & DELIVERY OF SPACE MAINTAINERS WHEN PREMATURE EXTRACTION OF PRIMARY MOLAR UNDER GENERAL ANESTHESIA : A CASE REPORT (전신마취하에서 유치 조기발거시 간격유지장치의 설계 및 장착에 대한 증례보고)

  • Kang, Dug-Il;Jung, Moon-Young;Lee, Sang-Ho;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.3
    • /
    • pp.704-709
    • /
    • 1997
  • Space maintainers needs following extraction of primary molars, due to severe dental caries under general anesthesia. Delivery of conventional space maintainers has three of the disadvantages of the method, there being a impression taking and time consuming due to laboratory procedure, and delivery problem due to relaxed tongue. For this problem improved, modified space maintainer is prefabricated before procedure, and adjust, delivery in operation room, favorable results were obtained. The following results were obtained. 1. Delivery time is very reduced than conventional space maintainers. 2. After space maintainer delivery, follow check-up, without impingement of soft tissue, distortion of wire. After space maintainer delivery, continuous research is required so that space maintainer delivery is applied to usual dental treatment, and it is necessary of long term research.

  • PDF

AN ELECTROMYOGRAPHIC STUDY OF THE MASSETER MUSCLES IN CHILDREN WITH SPACE MAINTAINER (보극장치(保隙裝置) 장착아동(裝着兒童)의 교근활성도(咬筋活性度)에 관(關)한 근전도학적(筋電圖學的) 연구(硏究))

  • Ahn, Kyu-So
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.1 no.1
    • /
    • pp.49-55
    • /
    • 1974
  • Electromyographic studies were performed on the action of the masseter muscles. Among the children aged from 6 to 8 years, ten children with normal occlusion and another ten with space maintainer were selected. The children were divided into 3 groups. They were: 1) A group: Children who removed space maintainer 2) B group: Children who inserted space maintainer 3) C group: Children with normal occlusion. The electromyogram was recorded with 4 channel polygraph. (Grass model VII) Electrodes which were cup-typed gold disks, 9 millimeters in the diameter, were located on the superficial layer of masseter muscles. The electromyogram was recorded in the physiologic rest position, molar occlusion, chewing movement, protraction, left lateral movement, and right lateral movement. The conclusions were as follows. 1. In the physiologic rest position, lateral movement, the electrical potentials of the masseter muscles were not changed clearly in each groups. 2. In molar occlusion, chewing movement, The electrical potentials of the masseter muscles of the B group were almost 10% higher than those of A group, and were almost 60-70% in comparision with C group. 3. In protraction, the electrical potentials of the masseter muscles of the B group were almost 40% higher than those of A group, and were almost equal to C group. 4. The electrical activities of the masseter muscles in the mandibular movements were in the following order: (1) Molar occlusion (2) Chewing movement (3) Protraction (4) Lateral movement.

  • PDF

Application of the Molecular Marker in Linkage Disequilibrium with Ms, a Restorer-of-fertility Locus, for Improvement of Onion Breeding Efficiency

  • Kim, Sujeong;Kim, Sunggil
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.550-558
    • /
    • 2015
  • To analyze the linkage relationships among molecular markers recently reported to be linked to onion (Allium cepa L.) Ms, a restorer-of-fertility locus, in onion (Allium cepa L.), three single nucleotide polymorphism markers were converted into cleaved amplified polymorphic sequence (CAPS) markers based on onion transcriptome sequences and the rice genome database. Analysis of the recombinants selected from 4,273 segregating plants using CAPS and other linked markers demonstrated the jnurf13 and jnurf610 markers to perfectly co-segregate with the Ms locus. In contrast to jnurf13, the jnurf610 marker was not in perfect linkage disequilibrium with the Ms locus in diverse breeding lines. Thus, the jnurf13 marker and the marker for identification of cytoplasm types were utilized to enhance the efficiency of onion breeding through four applications. First, 89 maintainer lines containing the normal cytoplasm and homozygous recessive Ms genotypes were successfully identified from 100 breeding lines. Second, these two molecular markers were used to analyze the main sources of male-fertile contaminants frequently found in the male-sterile parental lines during F1 hybrid seed production. The majority of the contaminants contained heterozygous Ms genotypes, indicating that pollen grains harboring the dominant Ms genotype may have been introduced during propagation of the maintainer lines. Therefore, the genetic purity of the two maintainer lines was analyzed in the third application, and the results showed that both maintainer lines contained 13-21% off-types. Finally, the two markers were used to increase the seed yield potentials of two open-pollinated varieties containing sterile cytoplasms by removing the plants harboring homozygous recessive and heterozygous Ms genotypes.

Longitudinal Study on Effects of Dfntal Arch Growth in the Case of Using a Space-Maintaier After Primary Tooth Extraction (유치조기발거후 보극장치물이 치궁발육에 미치는 영향)

  • Shon, Dong-Su
    • The Journal of the Korean dental association
    • /
    • v.11 no.4
    • /
    • pp.277-280
    • /
    • 1973
  • The author observed the changes of dental arch dimensions and compared spae-maintainer group with non-space-maintainer group after primary tooth extraction. The results were as follows 1) The rate of growth of dental arch of expeirmental group in intercanine width and in inter-1st molar width was more rapid than that of the control group. 2) Arch length is almost no dimensions but it was slightly decreased in lower arch. 3) Dental arch growth and tooth eruption were stimulated by space-maintainer appliance, so it is the best way to replace a new appliance at least once a year. 4) It is thought that satisfactory conclusions in this observation must be researched successively until the mixed dentition completes.

  • PDF

Studies on Heterosis Breeding in Rapeseed Using Cytoplasmic Male Sterility 2, Agronomic Characteristics of F_1 Seed Production Procedure in the Three-way Crossing of Cytoplasmic-genetic Male Sterile, Non-Isogenic Maintainer and Restorer on Rape (Brassica napus L.) (세포질 유전자적 웅성불임계통을 이용한 유체 Heterosis 육종 개발에 관한 연구 제2보 웅성불임계통에 Non-Isogenic Maintainer를 활용한 유체 3원교잡F_1의 형질발현과 F_1종자생육)

  • Jung-Il Lee;Jung-Il Lee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.25 no.2
    • /
    • pp.49-57
    • /
    • 1980
  • A $F_1$ hybrid out of 143 crosses of rape (Brassica napus) using cytoplasmic-genetic male sterility yielded 5.18 tons per hectare. European and native varieties used, were found out to have 78% and 58% of genes restoring fertility, respectively. The $F_1$ hybrids of three way cross using non-isogenic maintainer showed higher heteroses than those of double cross. To produce F 1 hybrids of three way cross, three stages of crossing operations are needed and seeds produced from about 60 hectares can be covered to 60, 000 hectares.

  • PDF

Utilization of Male Sterility Type and Frequency of Male Sterile Genes in Carrots (당근 웅성부임성(雄性不稔性)의 형태별(形態別) 이용현황(利用現況)과 핵내(核內) 웅성부임(雄性不稔) 유전자(遺傳子)의 분포(分布))

  • Suh, Young Ki;Youn, Goang Hyeon;Cho, Young Hwan;Paek, Kee Yoeop
    • Horticultural Science & Technology
    • /
    • v.17 no.4
    • /
    • pp.470-472
    • /
    • 1999
  • When the type and ratio of male-sterile plants in $F_1$ hybrids collected from several seed companies were investigated, there were differences in the male-sterile type depending upon region, seed company and variety group. The differences were inferred due to the easiness in breeding of maintainer line among the variety groups. American seed companies mainly used petaloid type male sterility with Imperater group varieties. European companies used brown anther type male sterility mainly with Nantes group but some companies used petaloid type also in varieties that were different from Nantes group. Asian companies (Japan, Korea) used both types with Chantaney and Kuroda group varieties, but one type was mainly used depending on individual seed company. Only one type of male-sterility in one variety was observed and the results were agreed well with other's results that male-sterility type was determined by cytoplasm factor. Some breeding lines were backcrossed to both types of cytoplasm (Sa, Sp) for maintainer line selection. We could select 15 maintainer lines from 20 lines in petaloid cytoplasm (Sp) and 3 from 4 lines in brown cytoplasm (Sa). In petaloid cytoplasm, maintainer lines can be selected at considerably high frequency. But in brown anther cytoplasm, the used materials are too restricted to tell general frequency maintainer lines.

  • PDF

소아치열기의 저작능률에 관한 실험적 연구

  • Kim, Jin-Tae
    • The Journal of the Korean dental association
    • /
    • v.12 no.4
    • /
    • pp.241-244
    • /
    • 1974
  • The author measured the masticatory efficiency in the 50 children with normal sound dentition, in the 20 children with amalgam filling and in the 20 children with fixed type space maintainer i.e. in the 90 children in total and got the following results. 1. the masticatory efficiency were 53.8% in children with normal sound primary dentition. 2. The masticatory efficiency 48.3% in children with amalgam filling and 40.0% in children with fixed type space maintainer 3. The masticatory efficiency of children were 60.0% of adult's in normal dentition.

  • PDF