DOI QR코드

DOI QR Code

Space maintainer using CAD/CAM system without a band: a case report

CAD/CAM 시스템을 이용하여 band 없이 공간유지 장치를 제작한 증례

  • Eun-Sook Kang (Department of Dentistry, College of Medicine, Kosin University)
  • 강은숙 (고신대학교 의과대학 치과학교실)
  • Received : 2024.01.30
  • Accepted : 2024.03.25
  • Published : 2024.05.31

Abstract

Early interceptive orthodontic interventions are often started in the developing dentition to guide normal occlusion. The simplest way to prevent eruption failure from deciduous tooth loss is to fix a space maintainer such as a band and loop. Band and loop space maintainer has several problems like cement loss, demineralization, locking of the adjacent tooth, and needs to take a pickup impression of the band. Computer-assisted design/computer-assisted manufacturing (CAD/CAM) space maintainer without band was developed to solve these problems. This case report describes successful eruption of the mandibular second premolar using CAD/CAM without a band.

조기 교정치료의 개입은 종종 성장하는 치열을 정상 교합으로 유도하는 것에서부터 시작된다. 유치의 상실로 인한 맹출 실패를 예방하는 가장 간단한 방법은 밴드 및 루프와 같은 공간 유지장치를 부착하는 것이다. 밴드 및 루프 공간 유지장치는 밴드의 픽업 인상 과정을 거쳐야 하며, 시멘트 소실과 탈회, 인접치의 locking과 같은 문제들을 갖고 있다. 이러한 문제를 해결하기 위해서 CAD/CAM을 이용한 band가 필요 없는 공간유지장치가 개발되었다. 본 증례는 밴드 없이 CAD/CAM을 이용하여 하악 제2소구치가 성공적으로 맹출할 수 있었기에 이를 보고하는 바이다.

Keywords

References

  1. Barberia E, Lucavechi T, Cardenas D, Marato M. Free-end space maintainers: Design, utilisation and advantages. J Clin Pediatr Dent 2006;31:5-8.
  2. Rao AK, Sarkar S. Changes in arch length following premature loss of deciduous molars. J Indian Soc Pedo Prev Dent 1999;17:29-32.
  3. Ngan P, Alkire RG, Fields H Jr. Management of space problems in the primary and mixed dentitions. J Am Dent Assoc 1999;130:1330-9.
  4. Setia V, Pandit IK, Srivastava N, Gugnani N, Sekhon HK. Space maintainers in dentistry: Past to present. J Clin Diagn Res 2013;7:2402-5.
  5. Kirzioglu Z, Erturk MS. Success of reinforced fiber material space maintainers. J Dent Child 2004;71:158-62.
  6. Bijoor RR, Kohli K. Contemporary space maintenance for the pediatric patient. N Y State Dent J 2005;71:32-5.
  7. Wright CZ, Kennedy DB. Space control in the primary and mixed dentitions. Dent Clin North Am 1978;22:579-601.
  8. Qudeimat MA, Fayle SA. The longevity of space maintainers: A retrospective study. Pediatr Dent 1998;20:267-72.
  9. Deshpande SS, Bendgude VD, Kokkali VV. Survival of bonded space maintainers: A systematic review. Int J Clin Pediatr Dent 2018;11:440-5.
  10. Dhanotra KG, Bhatia R. Digitainers-digital space maintainers: A review. Int J Clin Pediatr Dent 2021; 14 Suppl 1:S69-75.
  11. Vasudavan S, Sullivan SR, Sonis AL. Comparison of intraoral 3D scanning and conventional impressions for fabrication of orthodontic retainers. J Clin Orthod 2010;44:495-7.
  12. Ender A, Attin T, Mehl A. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. J Prosthet Dent 2016;115:313-20.
  13. Tokuc M, Yilmaz H. Comparison of fit accuracy between conventional and CAD/CAM-fabricated band-loop space maintainers. Int J Paediatr Dent 2022;32:764-71.
  14. Kravitz ND, Grauer D, Schumacher P, Jo YM. Memotain: A CAD/CAM nickel-titanium lingual retainer. Am J Orthod Dentofacial Orthop 2017;151:812-5.
  15. Jowett AC, Littlewood SJ, Hodge TM, Dhaliwal HK, Wu J. CAD/CAM nitinol bonded retainer versus a chairside rectangular-chain bonded retainer: A multicentre randomised controlled trial. J Orthod 2023;50:55-68.
  16. Gelin E, Seidel L, Bruwier A, Albert A, Charavet C. Innovative customized CAD/CAM nickel-titanium lingual retainer versus standard stainless-steel lingual retainer: a randomized controlled trial. Korean J Orthod 2020;50:373-82.
  17. Yoo JI, Kim SY, Batbayar B, Kim JW, Park SE, Cho KM. Comparison of flexural strength and modulus of elasticity in several resinous teeth splinting materials J Dent Rehabil Appl Sci 2016;32:169-75.
  18. Simsek S, Yilmaz Y, Gurbuz T. Clinical evaluation of simple fixed space maintainers bonded with flow composite resin. J Dent Child (Chic) 2004;71:163-8.