• Title/Summary/Keyword: main effects

Search Result 6,958, Processing Time 0.035 seconds

Simulation analysis of type I error and power for F test and rank transformed F test in $2 times 2$ factorial ANOVA ($2 times 2$ 요인 계획법의 F 검정과 순위 F 검정에 따른 제1종 오류와 검정력 분석에 대한 의태 연구)

  • 최영훈
    • The Korean Journal of Applied Statistics
    • /
    • v.8 no.2
    • /
    • pp.87-97
    • /
    • 1995
  • When there is no main effcts or only one main effect in a $2 \times 2$ factorial design, Type I error rates and power for the rank transformed F test (FR test) for interaction are nearly equal to those of the classical F test. However the power of FR test is quite superior under the exponential distribution rather than the of FR test is quite superior under the exponential distribution rather than the normal distribution. Meanwhile when both main effects are in the model, Type I error rates of FR test, compared with those of F test, decrease as the effect size increases and are dependent on the fashion in which main effects are constructed. In addition, the power of FR test increases as the effect size and the sample size increase and is highly dependent on the manner in which main effects are constructed and the type of population distribution.

  • PDF

ICING EFFECTS ON AERODYNAMIC CHARACTERISTICS OF THE MAIN WING SECTION OF KC-100 AIRCRAFT (KC-100 항공기 주날개의 결빙에 의한 공력 영향성 연구)

  • Lee, C.H.;Sin, S.M.;Jung, S.K.;Myong, R.S.;Cho, T.H.;Jung, J.H.;Jeong, H.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.464-467
    • /
    • 2010
  • Ice accretion on aircraft surface in icing condition induces external shape changes that may result in a hazard factor for aircraft safety. In case of aircraft main wing with high lift equipment, ice accretion is observed around leading edge and flap. During the design phase, location of ice accretion and associated aerodynamic characteristics must be investigated. In this study, icing effects on aerodynamic characteristics of the main wing section of KC-100 aircraft are investigated using an Eulerian-based FENSAP-ICE code in various icing conditions.

  • PDF

Buckling Design of Temporary Bridges Subjected to Both Bending and Compression (압축과 휨을 동시에 받는 가교량 주요부재의 좌굴설계)

  • So Byoung-Hoon;Kyung Yong-Soo;Bang Jin-Hwan;Kim Moon-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.977-984
    • /
    • 2006
  • Generally main girders and steel piers of temporary bridges form the steel rahmen structure. In this study, the rational stability design procedure for main members of temporary bridges is presented using 3D system buckling analysis and second-order elastic analysis. 2 types of temporary bridges, which are possible to be designed and fabricated in reality, are chosen and the buckling design for them is performed considering load combinations of dead and live loads, thermal load, and wind load. Effective buckling length of steel piers, effects of live loads on effective length of main members, transition of ~id buckling modes, and effects of second-order analysis are investigated through case study of 2 temporary bridges.

  • PDF

An Improved Stability Design of Steel Cable-Stayed Bridges using Second-Order Effect (2차효과를 고려한 강사장교의 개선된 좌굴해석)

  • Kyung Yong-Soo;Kim Nam-Il;Lee Jun-Sok;Kim Moon-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.993-1000
    • /
    • 2006
  • Practical stability design method of main members of cable-stayed bridges is proposed and discussed through a design example. For this purpose, initial tensions of stay cables and axial forces of main members are firstly determined using initial shaping analysis of bridges under dead loads. And then the effective buckling length using system elastic/inelastic buckling analysis and bending moments considering $P-{\delta}-{\Delta}$ effect by second-order elastic analysis are calculated for main girder and pylon members subjected to both axial forces and moments, respectively. Particularly, load combinations of dead and live loads, in which maximum load effects due to live loads are obtained, are taken into account and effects of live loads on effective buckling lengths are investigated.

  • PDF

Effects of Beam Configuration on Performances of NOMA System for Millimeter Wave Channels

  • Wonkyu Kim;Thanh Ngoc Nguyen;Taehyun Jeon
    • International journal of advanced smart convergence
    • /
    • v.13 no.3
    • /
    • pp.59-65
    • /
    • 2024
  • Non-orthogonal multiple access (NOMA) is a technique that forms a NOMA group composed of two or more users and transmits the superimposed signals of all users in the group through a single beam. In case all users in a NOMA group fall within the main lobe, a high data rate is guaranteed. However, in case not all users in the group fall within the main lobe due to the narrow beam width, the sum data rate decreases, and the data rate disparity between users inside and outside the main lobe widens significantly, leading to reduced fairness. On the other hand, an excessively wide beam might reduce the channel gain which lowers the sum data rate. This paper discusses the effects of beam configuration on the throughput and fairness performances of the NOMA system in the millimeter wave channel environments with simulation results for various channel parameters including the number of antennas and beam directions.

Air Pollutants and Vegetation -With Special Reference to Sulfur Dioxide- (대기오염물질과 식물환경 -아황산에 의한 영향을 중심으로)

  • 이미순
    • Journal of Plant Biology
    • /
    • v.18 no.2
    • /
    • pp.45-52
    • /
    • 1975
  • Effects of air pollutants on vegetation were reviewed and discussed with special reference to sulfur dioxide. Main contents were on the sources, meteorological factors, injury symptoms, relative sensitivity, growth/yield, indicator/diagnosis, combined effects, injury mechanism and effects on plant metabolism, injury diminishing measures, and future research needs.

  • PDF

A study on Protective Coordination of MCA for Performing of the Pad Mounted Transformer's inside Protective Device (지상변압기의 내부 보호장비 작동을 위한 MCA 보호협조에 대한 연구)

  • Hyun, Seung-Yoon;Kim, Chang-Hwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.5-7
    • /
    • 2022
  • KEPCO's plan is undergoing a trial operation to replace the open-loop section with ring main units configuration where underground distribution lines are installed, by linking the multi-way circuit breakers auto (MCA) on the power side of each pad-mounted transformer. However, ring main units application mentioned above may cause the ripple effects, when implementing the configuration without a study of protection coordination. Because ring main units with classical pre-set protection devices contribution in fault condition didn't consider yet. For the reliable ring main units operation, it is necessary to resolve several protection issues such as the protection coordination with substation side, prevention of the transformer inrush current. These issues can radically deteriorate the distribution system reliability Hence, it is essential to design proper protection coordination to reduce these types of problems. This paper presents a scheme of ring main units' configuration and MCA's settings of time-current curves to preserve the performance of protection coordination among the switchgears considering constraints, e.g. prevention of the ripple effects (on the branch section when a transformer failure occurs and the mainline when a branch line failure occurs). It was confirmed that the propagation of the failure for each interrupter segment could be minimized by applying the proposed TCC and the interrupter settings for the MCAs (branch, transformer). Further, it was verified that the undetected area of the distribution automation system (DAS) could be supplemented by having the MCA configurated ring main units operate first, instead of the internal protection equipment in the transformer such as the fuse, STP when a transformer failure occurs.

The Influence of Main Bearing Stiffness on the Gearbox of 3 Point Suspension Wind Turbine Drive Train (메인 베어링 강성이 풍력발전기용 3점 지지 드라이브 트레인의 기어박스에 미치는 영향)

  • Nam, Ju Seok;Nam, Yong Yun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.3
    • /
    • pp.278-286
    • /
    • 2015
  • The effects of the main bearing stiffness combined with vertical non-torque force on the input load and shaft deflection of a gearbox were investigated for the three-point suspension drive train of a wind turbine. A finite element analysis model for the drive train was studied experimentally, and its applicability to the present study was verified. The results show that, as the main bearing stiffness is increased, the input load of the gearbox decreases, whereas the input shaft deflection increases. The stiffness component for the pitch moment has the largest influence on the gearbox input load. Although the gearbox life increases at a higher main bearing stiffness, the economic efficiency and durability of the entire drive train system should also be considered in the selection of the main bearing stiffness.

Evaluation of Piping Integrity in Thinned Main Feedwater Pipes

  • Park, Young-Hwan;Kang, Suk-Chull
    • Nuclear Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.67-76
    • /
    • 2000
  • Significant wall thinning due to flow accelerated corrosion(FAC)was recently reported in main feedwater pipes in 3 Korean pressurized water reactor(PWR) plants. The main feedwater pipes in one plant were repaired using overlay weld method at the outside of pipe, while those in 2 other plants were replaced with new pipes. In this study, the effect of the wall thinning in the main feedwater pipes on piping integrity was evaluated using finite element method. Especially, the effects of both the overlay weld repair and the stress concentration in notch-type thinned area on the piping integrity were investigated. The results are as follows : (1) The piping load carrying capacity may significantly decrease due to FAC. In special, the load carrying capacity of the main feedwater pipe was reduced by about 40% during about 140 months operation in Korean PWR plants. (2) By performing overlay weld repair at the outside of pipe, the piping load carrying capacity can increase and the stress concentration level in the thinned area can be reduced.

  • PDF

Development and Applications of a Methodology and Computer Algorithms for Long-term Management of Water Distribution Pipe Systems (상수도 배수관로 시스템의 장기적 유지관리를 위한 방법론과 컴퓨터 알고리즘의 개발 및 적용)

  • Park, Suwan
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.3
    • /
    • pp.356-366
    • /
    • 2007
  • In this paper a methodology is developed to prioritize replacement of water distribution pipes according to the economical efficiency of replacement and assess the long-term effects of water main replacement policies on water distribution systems. The methodology is implemented with MATLAB to develop a computer algorithm which is used to apply the methodology to a case study water distribution system. A pipe break prediction model is used to estimate future costs of pipe repair and replacement, and the economically optimal replacement time of a pipe is estimated by obtaining the time at which the present worth of the total costs of repair and replacement is minimum. The equation for estimating the present worth of the total cost is modified to reflect the fact that a pipe can be replaced in between of failure events. The results of the analyses show that about 9.5% of the pipes in the case study system is required to be replaced within the planning horizon. Analyses of the yearly pipe replacement requirements for the case study system are provided along with the compositions of the replacement. The effects of water main replacement policies, for which yearly replacement length scenario and yearly replacement budget scenario are used, during a planning horizon are simulated in terms of the predicted number of pipe failures and the saved repair costs.