• Title/Summary/Keyword: magnification

Search Result 689, Processing Time 0.021 seconds

Measurements of Two-dimensional Gratings Using a Metrological Atomic Force Microscope with Uncertainty Evaluation

  • Kim, Jong-Ahn;Kim, Jae-Wan;Kang, Chu-Shik;Eom, Tae-Bong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.18-22
    • /
    • 2008
  • The pitch and orthogonality of two-dimensional (2-D) gratings were measured using a metrological atomic force microscope (MAFM), and the measurement uncertainty was analyzed. Gratings are typical standard devices for the calibration of precision microscopes, Since the magnification and orthogonality in two perpendicular axes of microscopes can be calibrated simultaneously using 2-D gratings, it is important to certify the pitch and orthogonality of such gratings accurately for nanometrology. In the measurement of 2-D gratings, the MAFM can be used effectively for its nanometric resolution and uncertainty, but a new measurement scheme is required to overcome limitations such as thermal drift and slow scan speed. Two types of 2-D gratings with nominal pitches of 300 and 1000 nm were measured using line scans to determine the pitch measurement in each direction. The expanded uncertainties (k = 2) of the measured pitch values were less than 0.2 and 0.4 nm for each specimen, and the measured orthogonality values were less than $0.09^{\circ}$ and $0.05^{\circ}$, respectively. The experimental results measured using the MAFM and optical diffractometer agreed closely within the expanded uncertainty of the MAFM. We also propose an additional scheme for measuring 2-D gratings to increase the accuracy of calculated peak positions, which will be the subject of future study.

A Clinical Experience of Cleft Palate Repair Using Operative Microscope: Sommerlad's Method (Sommerlad씨 술식에 따른 미세수술 술기를 이용한 구개성형술의 경험)

  • Park, Myong Chul;Shin, Seung Jun;Lee, Il Jae
    • Archives of Plastic Surgery
    • /
    • v.33 no.1
    • /
    • pp.61-66
    • /
    • 2006
  • The purpose of this study is to introduce the method of palate repair that combines minimal hard palate dissection and radical retropositiong of levator musculature, which was presented by Sommerlad. As this method presents, additional use of the operating microscope enables atraumatic and radical dissection, and it might provide more improved speech function to the patients. A total of 17 patients with cleft palate underwent Sommerlad's method from December 2003 to August 2004. The mean follow-up period was 4.5 months. The use of a microscope provided high quality variable magnification and good illumination at the operating field. Repair was carried out through incisions at the margins of cleft with mucoperiosteal flap elevation. Muscles were rearranged and repaired properly. It was unable to evaluate the improvement of speech because the patients were too young to learn meaningful speech. Average operating time including anesthetic induction time, V-tube insertion and recovery from anesthesia was 2 hours 45 minutes which was not quite different from conventional method's operating time. Oronasal fistula developed in 2 patients of them. One of them was healed spontaneously. As meticulous and radical muscle dissection was possible with Sommerlad's method, we could minimize the trauma to the muscular and neurovascluar structure. In addition, we expect better faculty of speech as a result of this method although longer follow-up time was unavailable.

Whether Pinhole Scan or Single Photon Emission Computed Tomography (SPECT) in the Diagnosis of Bone and Joint Diseases (골격계진단에 있어서 핀홀스캔의 우월성)

  • Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.1-14
    • /
    • 1996
  • Since the publication of the first bone scintiscans in 1962 three decades have elapsed. The bone scan has made great strides during this period, becoming one of the most commonly used nuclear imaging tests. In spite of the progress, however, the specificity of bone scan has remained relatively low. As the result it is a common practice to seek additional information from radiograph, CT scan and MR image, which is euphemistically termed as "image fusion or co-location." The basic reason is the inapplicability of the classical piecemeal analysis to interpreting planar and SPECT bone scans. Such analysis has its base on the observation of elemental features of morphology, which include the size, shape, contour, location, topography and internal architecture. The physiochemical profile may well also be included. Understandably, however, the miniatured images of the planar bone scan cannot provide these features in acceptable detail and the same holds true even with SPECT Images which are but sliced views of the reconstructed planar scans. Fortunately pinhole scanning has the capacity to portray both the morphological and chemical profiles of bone and joint diseases in greater detail through true magnification. The magnitude of pinhole scan resolution is practically comparable to that of radiography as far as gross anatomy is concerned. Thus, we feel strongly that pinhole scanning is a potential breakthrough of the long-lamented low specificity of bone scan. This presentation will discuss the fun-damentals, advantages and disadvantages and the most recent advances of pinhole scanning. It high-lights the actual clinical applications of pinhole scanning in relation to the diagnosis of infective and inflammatory diseases of bone and joint.

  • PDF

Molt-related Changes in the Granulocytes of the Spider Araneus ventricosus (Araneae: Arachnida) (탈피에 따른 산왕거미(Araneus ventricosus) 과립혈구의 미세구조 변화)

  • Moon, Myung-Jin
    • Applied Microscopy
    • /
    • v.38 no.2
    • /
    • pp.97-105
    • /
    • 2008
  • The fine structural modification of the granulocytes between the molt and intermolt period were investigated by the transmission electron microscopy. The granular hemocytes of the spider Araneus ventricosus were composed of three subtypes: eosinophilic granulocytes (EGs), basophilic granulocytes (BGs) and cyanocytes. Both of the EGs and BGs have electron dense granules within their cytoplasms, however the granules of BGs are larger than those of EGs. During the molt period, some of the EGs have fine structural modification in their cell organelles including formation of phagosomes as a result of active phagocytosis. However, the BGs have no phagosomes, but electron densities of the granules are changed to lower states than the intermolt period. The cyanocyte is the biggest hemocyte among the granulocytes. They contain numerous hemocyanin crystals in the cytoplasm with some electron-lucent vacuoles. During the molt period, some of the cyanocytes are changed to irregular shapes. High magnification electron micrographs reveal that the lattice sub-structure of the hemocyanin crystals are very similar to those of microtubules, and each tubule is composed of approximately 20 filaments with fine fibrillar structure.

An Immunohistochemical Study of Tumor Angiogenesity in Follicular Thyroid Carcinoma (여포상 갑상선암종의 종양맥관형성도)

  • Chung Woong-Youn;Lee Mi-Kyung;Chang Hang-Suk;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.191-198
    • /
    • 1998
  • Objectives: We performed an immunohistochemical study to examine the place of neovascularization in the tumorigenic process of follicular thyroid carcinoma and to determine whether tumor angiogenic activity in follicular carcinoma plays a role in tumor aggression. Materials & Methods: We studied 63 follicular thyroid carcinomas and compared with 22 follicular adenomas. The areas of capsular invasion, vascular invasion and cellular atypism of the tumor were confimed on H & E stains. The paraffin embedded tissues were stained by the use of monoclonal antibodies against Ag CD34. Microvesseles were counted in the area of highest vascular density at 200 times magnification. The microvessel densities(MVD) were analized in relation to histologic type and location of the tumors. Results: There were 59 minimal invasive types and 4 widely invasive types of carcinoma. In the histologic specimens of carcinomas, capsular invasion was identified in all the cases, vascular invasion in 46 and cellular atypism in 24. Mean values of the MVDs of the minimal invasive carcinomas, the widely invasive carcinomas and the adenomas were $263.8{\pm}69.2,\;256.l{\pm}49.3\;and\;241.5{\pm}159.4$, respectively and there was no significant difference between each group. In follicular carcinomas, there was a regional difference of the MVDs. The areas of tumor showing cellular atypism and adjacent to or penetrating the capsule, in which represents the tumorigenic process of carcinoma, had a higher rate of vascularization, than other areas of the tumor(p<0.05). However, these features were not noted in the follicular adenomas. Conclusion: Although there was no significant difference of the MVD between follicular carcinomas and adenomas, there was a regional difference of the MVD within the carcinomas and the values were significantly higher in the more malignant areas, as indicated by cellular atypism and capsular invasion. Therefore, tumor angiogenic activity measured by MVD may play a role in tumor aggression in follicular thyroid carcinoma.

  • PDF

Gemological Identification of Black Diamonds Roughs from Zimbabwe (짐바브웨산 블랙다이아몬드 원석의 보석학적 감별연구)

  • Song, Oh-Sung;Kim, Jun-Hwan;Kim, Ki-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3054-3059
    • /
    • 2009
  • Natural black diamonds of single crystal, polycrystalline, and agglomerated roughs become important for their industrial and gem stone application. We performed the conventional gemological tests of thermal diffusion, apparent density, scratch test, and magnification test as well as the advanced tests of Raman spectroscopy, X-ray diffraction test and Lang topography. We conclude that scratch test with SiC paper was the most efficient method in view point of speed and cost. Raman spectroscopy and XRD were useful for identification of diamond while Lang topography offered a good visualization method of the grain structure of polycrystalline black diamond roughs.

EVALUATION OF THE SEALING ABILITY OF Microseal® OBTURATION TECHNIQUE (Microseal®을 이용한 근관충전법의 근관폐쇄능력 평가)

  • Oh, Tea-Seok;Yoo, Hyeon-Mee;Hwang, Hea-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.682-689
    • /
    • 1998
  • The purpose of this study was to evaluate the sealing ability of the Microseal$^{(R)}$, which was new obturation system made by Tycom company, U.S.A. Forty-five extracted single-rooted human teeth were resected at cemento-enamel junction and divided three groups. All canals were prepared using Profile system, and then each group was obturated by lateral condensation technique (group 1), vertical condensation technique (group 2) and Microseal$^{(R)}$ condensation technique (group 3) with root canal sealer. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$ and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were resected horizontally at 1 mm (level I), 2 mm (level II), 3 mm (level III) from the anatomical root apex using low speed microtome and examined with Image analyzer (IBASR, Zeiss co., Germany.) at ${\times}25$ magnification. The gab between the canal wall and the filling material, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was expressed percentage by calculating the ratio of the area of the resin to the total area of the canal and was analyzed statistically (one-way ANOVA). The results were as follows; 1. The mean ratio of leakage (%) was 6.46% at group 1, 3.06% at group 2, 11.27% at group 3. 2. When evaluating the ratio of leakage at the three levels, there was level I> level II> level III in all groups. Especially, the difference between level I and level III was statistically significant (p<0.05). 3. When evaluating the ratio of leakage at the three groups, there was group 3> group 1> group 2 at all levels. Especially the difference between group 2 and group 3 was statistically significant (p<0.05).

  • PDF

A Study on the Visual System of the Digital Periapical Images (디지털 치근단방사선영상에 관한 시각 특성 연구)

  • Choi Eun-Suk;Koh Kwang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.261-274
    • /
    • 1999
  • Objectives: The purpose of this study was to evaluate the optimal distance and angle of observers by modulation transfer functions(MTFs) and receiver operating characteristics(ROCs), Material and Methods: Digital periapical radiograms were taken from 43 patients who have dental diseases(19 patients : dental caries. 12 patients : periapical lesions, 12 patients : periodontal diseases). Segmental images(4×4cm) were evaluated by 4 MTFs and ROC analysis. Results: The optimal distance(magnification) using MTF by Mannos & Sakrison was 12.97. and those by Nill. Ngan and Rao were 8.39, 4.78. 5.84 respectively. The optimal distance obtained from 4 radiologists by ROC analysis was 32cm(Az value: 0.89). and it was 40cm(Az value: 0.78) from 4 non-radiologists. There were significant differences of Az values between 4 radiologists and 4 non-radiologists at 24. 32 and 40cm (P<0.05). No significant differences of optimal distances were observed using 4 MTFs among +20, +10, 0, -10, -20 degrees(P>0.05). The optimal angle obtained from 4 radiologists by ROC analysis was +20 degree(Az value: 0.91). and no significant differences of Az values were observed among +20, +10, 0, -10 and -20 degrees(P>0.05). The optimal angle obtained from 4 non-radiologists by ROC analysis was 0 degree(Az value : 0.81). and no significant differences of Az values were observed among +20, +10, 0, -10 and -20 degrees(P>0.05). And there was significant difference of Az value between 4 radiologists and 4 non-radiologists at +20 degree(P<0.05). but no significant differences of Az values were observed among +10, 0, -10 and -20 degrees(P>0.05).

  • PDF

AN EVALUATION OF THE TIME-DEPENDENT DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS (인상채득 후 시간경과에 따른 고무인상재의 체적변화)

  • Lee Hong-Seok;Cho Suck-Kyu;Yoon Tae-Ho;Park Ju-Mi;Song Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.363-373
    • /
    • 2006
  • Statement of Problem : The accuracy and dimensional stability of elastomeric impression materials have been the subject of numerous investigation. Few studies have addressed the effect of changes in time on the dimensional stability of impression materials. Purpose: The purpose of this investigation was to evaluate the effects of elastomeric impression materials and storage time on dimensional stability. Materials and methods: A total of 75 impressions were made of epoxy resin dies mimicked prepared 3-unit fixed partial denture. The dies had 1 buccolingual, 1 mesiodistal and 1 occlusogingival lines and interpreped dot. Impression materials investigated included two polyether impression materials and three polyvinylsiloxane impression material. 15 specimens were made of each impression material and poured by type IV stone over times (30 minutes, 24 hours, 72 hours) after mixing; the same examiner measured each specimen 3 times at a magnification of 3.5$\times$. All statistical tests were performed with the level of significance set at .05. Results : The results indicated that significant difference at any measuring point of stone dies of the polyether impression materials and when measurements at 30 minutes, 24 hours, and 72 hours were compared ; the length of measuring point increased significantly as time passed by. However this result is not significant clinically. Analysis also showed significant differences at any measuring point when polyvinylsiloxane and polyether impression materials were compared and significant differences clinically. Conclusion: Under the conditions of this study, the shrinkage rate of the polyvinylsiloxane and polyether impression materials significantly increased as time passed by. The polyether impression materials showed higher shrinkage significantly, while the shrinkage rate of all five materials showed a significant time-dependent increase.

Effect of anatomic, semi-anatomic and non-anatomic occlusal surface tooth preparations on the adaptation of zirconia copings

  • Habib, Syed Rashid;Asiri, Waleed;Hefne, Mohammed Jameel
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.444-450
    • /
    • 2014
  • PURPOSE. To compare the accuracy of marginal and internal adaptation of zirconia (Zr) copings fabricated on anatomic (A), semi-anatomic (SA) and non-anatomic (NA) occlusal surface preparations. MATERIALS AND METHODS. 45 extracted bicuspid teeth were prepared for receiving zirconia crowns, with different occlusal preparation designs A=15, SA=15 & NA=15. The Zr copings were fabricated by using CAD4DENT, CAD/CAM. The copings were adjusted, cemented and were cross sectioned centrally from buccal cusp tip to lingual cusp tip into mesial and distal halves. The copings were examined under electron microscope at ${\times}200$ magnification and the measurements were recorded at 9 predetermined areas in micrometers. RESULTS. Overall mean gap values for the three groups was found to be $155.93{\pm}33.98{\mu}m$ with Anatomical Occlusal preparation design having the least gap value of $139.23{\pm}30.85{\mu}m$ showing the best adaptation among the groups. Post Hoc Tukey's test showed a statistically significant difference (P=.007) between the means of gap for A & NA preparation designs. Measurements recorded at 9 predetermined points showed variations for the three groups. CONCLUSION. Anatomical occlusal preparation designs resulted in better marginal and internal adaptation of Zr copings. There is a considerable variation between the measured marginal and internal gap values for the Zr copings fabricated by the (CAD4DENT-CAD/CAM). This variation may be associated with the lack of standardization of the preparation of teeth, computerized designing of the coping for each tooth, cement used, uniform pressure application during the cementation of the copings, sectioning of the copings and the microscopic measurements.