• Title/Summary/Keyword: magnification

Search Result 692, Processing Time 0.043 seconds

A Simple Method to Determination the Rotation Angle Between an Image and its Diffraction Pattern with LACBED Patterns (LACBED 패턴으로부터 전자현미경 상에 대한 회절도형의 회전각을 측정하는 간단한 방법)

  • Kim, Hwang-Su;Kim, Jong-Pil
    • Applied Microscopy
    • /
    • v.33 no.3
    • /
    • pp.187-193
    • /
    • 2003
  • When electron microscope images and selected area diffraction patterns of crystalline materials are being compared, it is important to know for the rotation of the diffraction pattern with respect to the image caused by the magnetic lens in the Electron Microscope. A well-known method to determine this rotation is to use a test crystal of $MoO_3$. But this method of determination of the rotation angle contains an uncertainty of $180^{\circ}$. Thus one has to devise another way to eliminate this uncertainty. In this paper we present a new and simple method of determining this rotation without any complexity. The method involves a process of obtaining LACBED patterns of crystalline materials. For the J2010 electron microscope, the rotation is determined to be $180^{\circ}$ and this angle remains unchanged for changing of the magnification and the camera length.

Investigation of Micromorphological Characteristics of Acupuncture Needle Tip Sold in Europe (유럽에서 유통되는 일회용침 끝의 미세 형태에 대한 관찰)

  • Jang, In-Soo;Lee, Tae-Ho;Lee, Chang-Hyun;Park, Jong-Bae
    • Korean Journal of Acupuncture
    • /
    • v.21 no.4
    • /
    • pp.43-51
    • /
    • 2004
  • Objectives : In order to ensure safe acupuncture treatment, the quality of the needle tip is essential. But, there have not been so many studies about the quality of the acupuncture needle tip. For this reason we have been already reported about the quality of acupuncture needle tip in Korea using scanning electron microscope(SEM) in 2002, 2003. In order to compare than other society, we investigated the current condition of the tips of the acupuncture needles sold in Europe. Methods : We obtained the needles made by 7 companies, which are sold currently in Europe, and selected 50 pieces out of 100 pieces from each company by randomized methods. And then we observed the tip of each needle using a scanning electron microscope at ${\times}800$ magnification. Results and Discussion : We found that needles had several defects such as scratch marks on the surface, metallic scuff, lumps and irregularities of the needle tips, stubbed or malformed tips, tips of point off-center, peeled off coated tips, same as Korean needles. There was much difference on the quality of needles among the manufacturers, and some needles seem to need thorough quality control. Allowing for the high price, the quality of some needle in Europe generally are better than that of Korean needles. But some Korean needles hold a top position than European ones in quality. We want a good industrial standard to be made in acupuncture manufacturing fields in the near future, because the safety is not less valuable than the efficacy in medicine.

  • PDF

Development of Line Standards Measurement System Using an Optical Microscope (광학 현미경을 이용한 선표준물 측정 시스템 개발)

  • Kim, Jong-Ahn;Kim, Jae-Wan;Kang, Chu-Shik;Eom, Tae-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.8
    • /
    • pp.72-78
    • /
    • 2009
  • We developed a line standards measurement system using an optical microscope and measured two kinds of line standards. It consists of three main parts: an optical microscope module including a CCD camera, a stage system with a linear encoder, and a measurement program for a microscopic image processing. The magnification of microscope part was calibrated using one-dimensional gratings and the angular motion of stage was measured to estimate the Abbe error. The threshold level in line width measurement was determined by comparing with certified values of a line width reference specimen, and its validity was proved through the measurement of another line width specimen. The expanded uncertainty (k=2) was about 100 nm in the measurements of $1{\mu}m{\sim}10{\mu}m$ line width. In the comparison results of line spacing measurement, two kinds of values were coincide within the expanded uncertainty, which were obtained by the one-dimensional measuring machine in KRISS and the line standards measurement system. The expanded uncertainty (k=2) in the line spacing measurement was estimated as $\sqrt{(0.098{\mu}m)^2+(1.8{\times}10^{-4}{\times}L)^2}$. Therefore, it will be applied effectively to the calibration of line standards, such as line width and line spacing, with the expanded uncertainty of several hundreds nanometer.

A Study on the Curvature Characteristic of the Incomplete Composite Girder Considering the Deflection Effect (처짐을 고려한 불완전합성형의 곡률특성에 관한 연구)

  • Yong, Hwan Sun;Kim, Yun Hwan;Park, Yong Chan;Song, Su Yeop
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.803-811
    • /
    • 2002
  • Current composite steel and concrete bridges are designed using full-interaction theory assuming there is no relative slip, between the steel and concrete components along their interface, because of the complexities of partial-interaction analysis techniques. However, in the assessment of existing composite bridges this simplification may not be warranted as it is often necesary to extract the correct capacity and endurance from the structure. This may only be achieved using partial-interaction theory which tuly reflects the behaviour of the structure. In this paper, Parametric analyses have been carried out in order to confirm the partial-interaction curvatures with deflection effect using the finite element method. Therefore, the model is considered for simply supported steel and concrete composite bridges with a uniform distribution of connectors subjected to a single concentrated load. For the case studies, this study applicate a parameters such as the number and space of stud shear connector and elastic modulus of concrete slabs. From this study, it is known that partial-interaction effect was in the increase to the increasing the deflection of composite bridges, and stiffness and strength of slab concrete considering the occurrence of crack effect seriously to the partial-interaction behavior.

A Study of Deformation Depicted on Moschino's Collection -Focusing on 2006~2010 Year Collection- (모스키노 컬렉션에 표현된 데포르마시옹에 관한 연구 -2006~2010년의 Collection을 중심으로-)

  • Lee, Jee-Yeon;Cho, Jean-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.3
    • /
    • pp.488-500
    • /
    • 2011
  • [ $D{\'{e}}formation$ ]is one of the most important cultural factor which puts people at ease and gives a sense of security. This study, in the process, analyzes the works of Moschino. Moschino's designs are rated to have approached the sublime when it comes to transforming the psychological anxiety of everyday living into a laughter. After selecting one hundred-two of Moschino's designs from the Internet Web site(www.cft.or.kr, www.samsungdesign.net), this study examines and analyzes the characteristics and types of deformation found in them. The result as follows. The examination of deformation found in Moschino designs can be classified into a transformation, distortion, exaggeration, and illusion. Transformation, a conscious change of the existing form or function, was shown as the change of an existing position, form, function and designation of a new function. Distortion, an interpretation away from the reality or a "wrong interpretation," was shown by placing opposing factors in left-right position as an extreme asymmetry. Exaggeration, always beyond the realm of reality, was shown thorough an enlargement or a magnification of a specific part and a repetition of a detail factors. Illusion, through a distortion of reality results in something that looks new, was expressed through the effects of wearing a two-pieces, an expression of details, effects of wearing accessories, and an expression of a dynamism. Therefore, Moschino has reflected the desire of homo modern to transform the existing situation through many techniques of deformation.

Microscopic Excision of Neurilemmoma of the Extremities (사지에 발생한 신경초종의 미세수술적 치료)

  • Lee, Kwang-Suk;Woo, Kyung-Jo;Kim, Jong-Won
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.2 no.1
    • /
    • pp.88-93
    • /
    • 1996
  • Neurilemmomas are the most common benign tumor of the peripheral nerve trunks, and arises from the cells in the sheath of Schwann. Neurilemmomas are well encapsulated and may be separated easily from surrounding tissue and lie completely within a larger nerve trunk, with bundles of neurofibrils spread out over the surface of the tumor. A careful dissection and retraction of the nerve bundles will allow the tumor to be enucleated from the parent nerve without any significant interference with the function of the nerve. Resection of the involved nerve is seldom necessary and should be avoided if at all possible. Our aim in microscopic excision of neurilemmoma of extremities is to reduce any disturbance of the intact neurofibrils of the parent nerve. Thirteen cases of neurilimmomas were treated by microscopic excision at the Department of Orthopaedic Surgery, Korea University Hospital between January 1990 and March 1995. The results was as follows ; 1. The average age at surgical intervention was 40.1 years. Cases in fourth and fifth decades predominated. 2. In their anatomical distribution, 8 cases were in the upper extremity and 5 cases in the lower extremity. 11 cases were on the flexor surface. 3. On the operative field, all the tumors were well encapsulated, however 1 case of 13 was adherent to the periosteum of fibula. 4. In all cases, the tumor were enucleated from the parent nerve without any injury to nerve under high-power magnification, preserving individual fascicles, and sensory and motor function.

  • PDF

Biomechanical Testing of Anterior Cervical Spine Implants: Evaluation of Changes in Strength Characteristics and Metal Fatigue Resulting from Minimal Bending and Cyclic Loading

  • Kim, Sung-Bum;Bak, Koang-Hum;Cheong, Jin-Hwan;Kim, Jae-Min;Kim, Choong-Hyun;Oh, Seong-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.217-222
    • /
    • 2005
  • Objective: To achieve optimal fit of implant, it is necessary to bend the implant during spine surgery. Bending procedure may decrease stiffness of plate especially made of titanium and stainless steel. Typically titanium suffers adverse effects including early crack propagation when it is bent. We investigate whether 6 degree bending of titanium plates would decrease the stiffness after full cyclic loading by comparing with non-bending titanium plates group. Methods: Authors experimented 40 titanium alloy plates of 57mm in length, manufactured by 5 different companies. Total 40 plates were divided into two groups (20 bent plates for experimental group and 20 non-bent plates for control group). Twenty plates of experimental group were bent to 6 degree with 3-point bending technique and verified with image analyzer. Using the electron microscope, we sought for a initial crack before and after 3-point bending. Mechanical testing by means of 6000 cyclic axial-compression loading of 35N in compression with moment arm of 35mm-1.1 Nm was conducted on each plate and followed by the electron microscopic examination to detect crack or fissure on plates. Results: The stiffness was decreased after 6000 cyclic loading, but there was no statistically significant difference in stiffness between experimental and control group. There was no evidence of change in grain structure on the electron microscopic magnification. Conclusion: The titanium cervical plates can be bent to 6 degree without any crack or weakness of plate. We also assume that minimal bending may increase the resistance to fatigue fracture in cervical flexion-extension movement.

High-Speed Inkjet Monitoring Module for Jetting Failure Inspection (잉크액적 토출불량 검출을 위한 고속 잉크젯 모니터링 모듈)

  • Shin, Dong-Youn
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1521-1527
    • /
    • 2010
  • Since inkjet printing is being employed in production lines of electronics and display industries, the tack time for inspection of jetting failure has become very important because the throughput of the inkjet printing system can be extended to the maximum limit by adopting a shorter jetting inspection time. The most popular method for inspecting jetting failure involves the use of a linear stage, a high magnification lens, and a charge coupled devicecamera. However, this conventional approach requires approximately 60 s to complete the jetting inspection and might not be suitable for a high-speed reciprocating jetting inspection in endurance tests due to the unwanted mechanical vibration. In this study, a novel concept of an inkjet monitoring module is introduced, which has an overall inspection time of 18 s. For the shorter tack time of jetting inspection, the parameters affecting the tack time are discussed in this paper.

Ultrastructure of the Integument of Adult Paragonimus westermani (폐흡충 표피의 미세구조)

  • 최원영;유재을
    • Parasites, Hosts and Diseases
    • /
    • v.23 no.1
    • /
    • pp.111-122
    • /
    • 1985
  • The present study was performed to observe the ultrastructure of the integument of adult Paragonimus westermani. Dogs experimentally infected with 60 metacercariae of F. westermani were autopsied 4 months after the infection. Adult p. westermani were extracted from the dogs and the fine structure was studied by means of scanning and transmission electron microscope. The findings are as follows: 1. Scanning electron microscopic findings showed that the spines and the papillae are distributed at whole body surface but the well developed spines or papaillae are shown around the oral sucker and ventral sucker. 2. At the end of the body, excretory pore was found, the shape was irregular. 3. Transmission electron microscopic findings showed that plasma membrane, tegument, basal lamina, connective tissue, circular muscle layer, longitudinal muscle layer. nerve axon and tegumental cell were observed. 4. In higher magnification, plasma membrance and bar-shaped granules were found at the outer surface of the tegument.

  • PDF

The Optimization of NDT Method for Real Time X-ray Imaging (X선 실시간 영상장치를 이용한 비파괴시험 조건 최적화 연구)

  • Na, Sung-Youb;Choi, Yong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.1
    • /
    • pp.19-28
    • /
    • 1996
  • This study has investigated the optimization of NDT method and the minimum detectable defect size for complex structures such as the solid propellant rocket motor using real time X-ray imaging system. Test specimens were made of steel plates with various defect size, and installed with proper thickness for which solid propellant, rubber, and case converted to the steel equivalent thickness according to the radiographic equivalent theory. As the results, this examination obtained optimum magnification and X-ray energy, dose rate according to steel equivalent thickness, also, obtained the relationship between minimum detectable defect size and the ratio(defect depot/object thickness). Thus, this simulated test is the preliminary procedure before performing NDT for real objects, and is possibly applied for NDT of other complex structures.

  • PDF