• Title/Summary/Keyword: magnetic treatment

Search Result 1,529, Processing Time 0.036 seconds

Effect of Heat Treatment on The Magnetic Properties of FeSiB Thin Film (열처리가 FeSiB 연자성 박막의 자기특성에 미치는 영향)

  • Hong, Jong-Wook;Jang, Tae-Suk;Park, Jong-Wan
    • Korean Journal of Materials Research
    • /
    • v.12 no.11
    • /
    • pp.880-882
    • /
    • 2002
  • We have prepared magnetic thin films of FeSiB by sputtering and examined microstructure and magnetic properties of the annealed films in order to investigate the feasibility of the films to microsensor application. Effects of vacuum annealing on the magnetic properties of $Fe_{84}$$Si_{6}$$B_{10}$ films have been examined as a function of temperature. The heating rate and the holding time were 10 K/min and 1 hour, respectively. Vacuum condition was held during cooling to prevent oxidation of the films. The coercivity did not show any noticeable change (~1500 A/m), although the grain size of the crystalline phase in the annealed films increased gradually up to about 16 nm until 673 K. However, both the grain size and the coercivity increased steeply when the annealing temperature increased over 723 K. Since the saturation magnetization is closely related to the phase evolution, the variation of the saturation magnetization of the annealed films was similar to that of the ribbon materials; the thin films were transformed from amorphous to crystalline with $\alpha$-(Fe,Si) phase by increasing annealing temperature.

Treatment of Various Auricular Diseases Using Magnetic Disks (자석 압박을 이용한 다양한 이개 질환의 치료)

  • Seo, Hyo Seuk;Hong, Yoon Gi;Chang, Choong Hyun
    • Archives of Plastic Surgery
    • /
    • v.34 no.3
    • /
    • pp.371-376
    • /
    • 2007
  • Purpose: The earlobe is one of the areas which are most vulnerable to trauma. Various auricular diseases need compression treatment. We report a new compression method using magnetic disks. Methods: Seventeen patients with auricular diseases were treated from October 2002 to September 2006. The mean age was 29.1 years. The diseases details were osteochondroma in 2 patients; cauliflower's ears in 2 patients; acute otohematoma in 1 patient; and hypertrophic scars in 11 patients. The most common cause of their disease was ear piercing. The mean follow-up period was 8.9 months. All surgical procedures were performed under local anesthesia. To compress immediately, a pair of magnetic disks was applied to the anterior and posterior surface of the earlobe. Results: The results were generally good. Major complications, such as recurrence, necrosis, dehiscence, or infection, did not occur. Conclusion: A pair of magnetic disks are useful compression tool in various auricular diseases.

A Study of Magnetic Properties of 410L Stainless Steel for Manufacture of ABS Sensor Ring (410L 스테인레스 강의 ABS센서 링 제조를 위한 자기적 특성에 관한 연구)

  • Yang, H.S.;Kwak, C.S.;Rhim, J.K.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.11 no.4
    • /
    • pp.241-246
    • /
    • 1998
  • It is well known for 410L ferritic stainless steel powder to applicate a sensor ring in anti-lock brake system of automobile, several studies, because of its excellent magnetic properties. This study was carried out to investigate the magnetic properties such as the maximum magnetic induction, coercivity and maximum permeability of the materials with functions of sintering density, time and temperature, and concluded as follows: 1. Sintering under the circumstances of Ar gas and the temperature of $1250^{\circ}C$ for 60min, showed that nitrogen was increased, whereas carbon and oxygen decreased in quantities. 2. Both maximum magnetic induction value of 4700Gauss and permeability of 200 were obtained at the maximum sintering density of $6.89g/cm^2$. Here, the properties showed a linear increasement with increasing the sintering density. 3. Coercivity sharply decreased with incresing the sintering density and reached to 7.6Oe at the maximum sintering density of $6.89g/cm^2$.

  • PDF

A Study on the Improvement of Urinary Incontinence Symptoms in Patients with Acupuncture, Moxibustion and Magnetic Innervation Therapy (침구치료 및 체외자기장신경치료의 병행을 통한 여성 요실금 판자 치료에 관한 증례 고찰)

  • Kim, Seok-Jung;Park, Yeong-Sun;Kim, Dong-Chul
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.19 no.2
    • /
    • pp.261-270
    • /
    • 2006
  • Purpose : The purpose of this study is to show the effect of acupuncture, moxibustion and magnetic innervation therapy for urinary incontinence symptoms. Methods : Ten female patients suffering from urinary incontinence had been given the treatments of acupuncture, moxibustion and magnetic innervation therapy for more than 8 times. Before and after treatment, they accomplished questionnaire for quality life survey and checked vaginal pressure measurement with perionometer. Results : The results were as follows 1) The mean${\pm}SD$ of Questionnaire score was significantly decreased from $35.40{\pm}11.88$ to $21.20{\pm}7.66$ after treatment(P<&0.047). 2) The mean${\pm}SD$ of maximum vaginal presssure was significantly increased from $48.80{\pm}25.35mmHg$ to $62.20{\pm}25.09mmHg$(p<&0.040). 3) The mean${\pm}SD$ of average vaginal presssure was significantly increased from $33.50{\pm}19.62mmHg$ to$43.10{\pm}16.49mmHg$(p<&0.015). Conclusion : Our results suggested that acupuncture, moxibustion and magnetic innervation therapy is effective for urinary incontinence symptoms.

  • PDF

Application of Superconducting Magnetic Separation for Condenser Water Treatment in Thermal Power Plant

  • Lee, You-Jin;Kwon, Jun-Mo;Baik, Seung-Kyu;Han, Kwang-Soo;Ko, Rock-Kil;Sohn, Myung-Hwan;Ha, Dong-Woo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.2
    • /
    • pp.21-24
    • /
    • 2011
  • Superconducting high gradient magnetic separation (HGMS) has advantages to treat wastewater because it can generate high magnetic field and achieve rapid purification. In this study superconducting HGMS was applied to remove impurities from the condenser water in thermal power plant. The condenser water contained mainly hematite and maghemite and it was highly magnetized than hematite. In the HGMS tests using a 6-T cryo-cooled Nb-Ti superconducting magnet, the turbidity of the condenser water was effectively reduced up to 99.6% and the result showed better performance than that of the 0.5-T permanent magnet test. The higher magnetic field was applied in the range of 1-6T, the more iron oxides were removed. The effect of magnetic filter configuration on the condenser water treatment was also investigated. Consequently superconducting HGMS system can be applicable to remove iron oxide impurities from condenser water in thermal power plant.

Magnetic Properties of Al-Co-N Thin Films Dispersed with Co Particles

  • Han, Chang-Suk
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.21 no.1
    • /
    • pp.3-9
    • /
    • 2008
  • Al-Co-N thin films, Al-Co-N/Al-N and Al-Co-N/Al-Co multilayers containing various amounts of Co content were deposited by using a two-facing targets type dc sputtering (TFTS) system. The films were also annealed successively and isothermally at different annealing temperatures. Irrespective of Co content and preparation methods, all the as-deposited films were observed non-magnetized. It was found that annealing conditions can control the magnetic and electrical properties as well as the microstructure of the films.

A STUDY ON THE PHYSICAL PROPERTIES AND BIOLOGICAL CHARACTERISTICS OF DENTAL MAGNETIC ATTACHMENTS (치과용 자석부착장치의 물리적, 생물학적 특성에 관한 연구)

  • Lim, Yong-Sik;Kim, Yung-Soo;Kim, Chang-Whe;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.1
    • /
    • pp.1-22
    • /
    • 1999
  • In order to investigate various physical and biological properties of dental magnetic attachments studies on retentive characteristics, corrosion properties, cytotoxicity of different magnetic systems for dental applications were done. For the study of retentive characteristics changes of retentive force by increasing air gap, wear properties of various attachment systems and loss of magnetic force by heat treatment were measured. Forte study of corrosion property of magnet covering metal electrochemical corrosion was done in artificial saliva and 0.9% NaCl solution between $-1,000mV_{SCE}\;and\;+1,000mV_{SCE}$. Anodic polarization curves are obtained about 6 types of samples and 2 types of solution. Corroded surfaces were examined with metallurgical microscope, scanning electron microscope and surface profilometer. For the study of cytotoxicity of magnetic attachment and its field cell growth and agar overlay test were done. The results of this study were as follows. 1. In Magnetic attachments using closed circuit retentive force at zero air gap was greater than magnets using open circuit, but decrease of retentive force by increasing air gap was also greater than open systems. 2. After 40,000 cycles of wear test all mechanical attachment resulted in varing degree of retention loss but in magnetic attachments no loss of retentive force was observed. 3. The magnetic attachment using Neodymium magnet showed early loss of retentive force about $200^{\circ}C$ but attachment using Samarium magnet showed some resistance to heat treatment and complete retention loss was observed about $500^{\circ}C$. The keeper was not influenced by heat treatment in retention. 4. In electrochemical corrosion test Dyna magnetic attachment covering metal showed the highiest corrosion resistance and Shiner magnet covering metal showed the least corrosion resistance and examination of corroded surface with metallurgical microscope, scanning electron micro-scope and surface profilometer also showed same results with anodic polarization corves. 5. The result of cell culture tests on the magnet covered with metal showed least recognizable cytotoxicity.

  • PDF

기능성기를 지닌 고분자 자성체를 이용한 수용액 중 납이온 추출

  • 서형석;최규찬;나인욱;황경엽
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.175-176
    • /
    • 2004
  • To develope of efficient method for decontaminating of lead ions from industrial wastewater, treatment of aqueous lead solution with magnetic beads was investigated. Immobilization of carboxyl groups on tile surface of magnetic beads was carried out to introduce chelate effect between lead ions and beads. Experiments were performed with lead solutions and magnetic beads at pH 6. Lead ions were extracted during 1 hour, After extraction, magnetic beads were separated from water by outer magnetic force and the solution was analysed by atomic absorption spectroscopy (AAS). Over 90 % of lead ions could be removed from aqueous solution after beads application. This result indicate that magnetic beads can be used as a efficient method for removing lead ions from industrial wastewater.

  • PDF

Influence of the tempering and magnetic annealing on soft magnetic properties for the KM35F alloy (템퍼링 및 자장열처리가 KM35F 합금의 연자성 특성에 미치는 영향)

  • Park, Byung-Ki;Jeon, Yong-Sik;Kim, Dong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1240-1243
    • /
    • 2008
  • The tempering and magnetic annealing are used to improve the soft magnetic properties such as initial permeability coercivity and core loss of the KM35F alloy. The first heat treatmentis performed at the temperature less than the curie temperature of the KM35F alloy to remove the thermal stress for few hours in nitrogen atmosphere. The second stage heat treatment is performed the magnetic annealing at $500{\sim}800^{\circ}C$ for few hours in nitrogen atmosphere, and then quenching to room temperature in absence of oxygen. Finally, magnetic properties of the thermally treated KM35F alloy are investigated for application as a soft magnetic material of the ISO solenoid valve core and plunger.

  • PDF

Improvement of Boar Semen Quality by Sperm Selection Using Magnetic Nano-particles (마그네틱 나노비드를 이용한 돼지 정자 품질의 향상)

  • Chung, KI-Hwa;Son, Jung-Ho
    • Journal of Life Science
    • /
    • v.26 no.8
    • /
    • pp.943-947
    • /
    • 2016
  • The objective of this study was to see if fairly simple magnetic nano-particle treatment enhances boar semen qualities. Boar semen samples were prepared from the swine AI center and samples were divided by 4 different motility groups (1, >90%; 2. 80~90%; 3. 70~80%; 4. <70%) using computer assisted sperm analysis (CASA) evaluation. Boar semen was extended using BTS extender and same number of magnetic nano-particles as total number of spermatozoa in each sample was treated for 20 min and collected for 5 min at room temperature. Sperm qualities such as motility and viability were evaluated by the CASA before and after treatment. Sperm abnormality and degree of agglutination were also evaluated under the microscopic examination before and after treatment. There were significant changes (p<0.05) on sperm motility from all 4 different groups in the average of 7.11% after treatment. The enhancement of sperm motility changes was more clear in the groups of lower sperm motile groups (<70% and 70~80%; 19.12±1.08% and 5.67±0.71%, p<0.05). The sperm motility character in terms of curvilinear velocity (VCL), straight line velocity (VSL), average path velocity (VAP) and linearity (LIN, %) showed also similar pattern but motility enhancement wear more clear in below 70% motile group. Average sperm viability was increased to 4% by magnetic nano-particles (p<0.05). The percentage of sperm abnormality was also reduced significantly (p<0.05) to the range of 3.7~4.5% before after treatment. The degree of sperm agglutination was also reduced in lower motility groups by the magnetic nano-particle purification.