• Title/Summary/Keyword: magnetic shielding

Search Result 204, Processing Time 0.041 seconds

Sheld of AC magnetic filed using High Temperature Superconductor (고온초전도체에 의한 교류자장 차폐효과)

  • Kim, Sung-Hoon;Kim, Woo-Seok;Hahn, Song-Yop;Choi, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.932-934
    • /
    • 2002
  • In this paper, we proposed a method to shield perpendicular magnetic fields in high Tc superconductor(HTS) tape of a shell-type HTS transformer with double pancake windings. A diamagnetism of characteristics of superconductor is used to shield magnetic field. For a shielding experiment, a proper shielding model is chosen, and several kinds of HTS are used such as a monofilament HTS tape, two kinds of multifilament HTS tapes and YBCO film disk. The effect of shielding for the perpendicular magnetic field is measured with HTSs for shielding and their utility for shielding is proved.

  • PDF

Optimized Magnetic Shielding for the MagLev Vechicles (자기부상열차의 최적 자기 차폐)

  • 윤현보;박찬일;박희창;손영수;임계재
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.3
    • /
    • pp.17-25
    • /
    • 1991
  • Magnetic leakage flux which is generated from the levitation magnets, linear induction motors, and guide magnets of a MagLev(Magnetic Levitation) system is directly related to inter - system EMI, intra - system EMI, and biological effects. In this paper, the magnetic leakage flux from MagLev vechicles designed by Korea Resarch Institute of Ships & Ocean Engineering was calculated considering the various parameters which influence ma- gnetic field intensity around the MagLev system. Based on the calculated field intensity, the thickness of shielding material and shielding position for MagLev floor and side walls are calculated, taking into account the shielding effectiveness of a shield with minimum weight. For the nonuniform shielding method derived from the above procedure, the weight of a shield con- sisting of floor and side walls shielding can be reduced to more 50% than uniform shielding method.

  • PDF

Design of MSR for Magnetic Field Shielding of Low Frequency (저주파 자기장 차폐를 위한 자기차폐실 설계)

  • Choi, Hak-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.154-159
    • /
    • 2010
  • In this paper, the magnetically shielded room for low magnetic field shielding is designed and measured by fabricated. The size of magnetically shielded room was 3.0[m](W)$\times$3.0[m](L)$\times$3.0[m](H) to enter the industrial measuring instruments and analyzed DC and AC shielding characteristics of magnetic materials with a high permeability and AC shielding characteristics by eddy current of conductive materials. As a results, shielded room dimensions were obtained. To verify the analysis results, magnetically shielded room is fabricated and the calculated results are compared with the measured results. The Measured results show good agreement with calculated results. According to measurements, 5 times of 0.1[Hz] and 86 times of 60[Hz] is achieved at low frequency. The fabricated shielding room can be used as the magnetically shielding room for low magnetic field shielding.

Analysis of Shielding Effect on Gamma Radiation of Magnetic Aggregate Concrete Applied to Protective Facility (군 방호시설에 자철석 콘크리트 적용 시 감마선 차폐효과 분석)

  • Lee, Sang-Kyu;Lee, Ho-Chan;Lee, Gun-Woo;Han, Da-Hee;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.2
    • /
    • pp.129-135
    • /
    • 2020
  • The purpose of this research is to analyze the gamma ray shielding effect of heavy concrete containing magnetic aggregate and to confirm the applicability to the military protective facilities. In general, a military concrete structure protects combatants from bullets, and also it provides some radiation shielding. In this research, experiments were conducted using a Cs-137 source to check the gamma ray shielding effect. In addition, the Monte Carlo N-Particle(MCNP) modeling was applied to evaluate the gamma ray shielding effect of a military structure. As a result, as the concrete thickness increased, the shielding performance improved according th the linear attenuation law. With that, as the ratio of magnetic aggregate was increased, gamma ray shielding performance was also improved. Therefore, this research verified that the application of magnetic aggregate concrete to military facilities for radiation shielding purposes would be useful.

Analysis of Shielding Effectiveness and Estimation of Shielding Factor in Conductive and Magnetic Shields (도전성 및 자성 차폐체의 차폐효과 해석과 차폐인수 산정)

  • Kang, Dae-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.30-40
    • /
    • 2013
  • In this study the method based on flux linkage in cell was introduced in calculation of eddy currents by cell method. According to this method eddy current distribution and the loss can be evaluated and since the shielding effectiveness by flux cancelation of eddy current can be analyzed, this method is applicable to design of conductive shield. And also the formula of shielding factor were so deduced as to be applicable to finite-width infinite-length shielding sheets and infinite-length underground cable shield. These formula are adaptable to magnetic materials as well as conductive materials. As the results of calculation in model shields are follows. In case of finite-width infinite-length shielding sheet, shielding effectiveness increases with increasing of conductivity. In case of infinite-length underground cable shield, the effectiveness become higher with increasing of permeability. Especially the effectiveness is very high in materials with both high conductivity and permeability in underground cable shield.

Calculation and Mitigation of Magnetic Field Produced by Straight Line-Conductor with Finite Length (유한장 직선도체에 의한 자계의 계산 및 감소대책)

  • Kang, Dae-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.57-67
    • /
    • 2011
  • Purpose of this study is to find the mitigation method of magnetic field by finite length multi-conductors such as indoor distribution lines and to be applicable to design of the distribution lines. For this purpose, exact formula about the components $B_x$, $B_y$, $B_z$ of magnetic field need in case of straight line-conductor with finite length forward any direction. In this study simple formula of the components were deduced and by using these formula magnetic fields for various models of line-configurations were calculated. And also a calculation method of induced currents in conductive shield was presented and using this method, programing of calculation is relatively easy and calculation time is short. The magnetic field after cancellation by these induced currents was calculated. All of calculations were performed by Matlab 7.0 programs. Through the calculation results it could be obtained followings for the mitigation of magnetic fields. The separation between conductors ought to be smaller than smaller as possible. In case of 3-phase, delta configuration is more effective than flat configuration. In case of 3-phase, unbalanced currents ought to be reduced as possible.. In case of more than two circuits of 3-phase, adequate locations of each phase-conductor such as rotating configuration of 3-phase conductors are more effective. The magnetic shielding effect of the conductive shielding sheet is very high.

Electromagnetic Shielding Effectiveness of a Soft Magnetic Film for Application of Noise Reduction In RE Range (RF대역 노이즈 저감용 연자성 필름의 전자기파 차폐효과)

  • Kim Sang-Woo;Yun Yong-Woon;Kim Gwang-Yoon;Lee Yo-Chun;Lee Kyung-Sup
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.3 s.32
    • /
    • pp.31-36
    • /
    • 2004
  • We charaterized electromagnetic shielding properties of a soft magnetic film using by a ASTM method and 2-port flanged coaxial line method in a RF range and quantitatively analyzed factors for the shielding effectiveness of the soft magnetic film in far field. The shielding effectiveness of the soft magnetic film was dominantly affected by absorption loss not reflection loss in high frequency range of 4-13.5 GHz.

  • PDF

Preliminary Study of Cosmic-ray Shielding Material Design Using Monte-Carlo Radiation Transport Code (몬테카를로 방사선 수송 모델을 활용한 우주방사선 차폐체 설계 관련 선행연구)

  • Kang, Chang-Woo;Kim, Yeong-Chan
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.527-536
    • /
    • 2022
  • The radiation shielding characteristic of neutron shielding material has been studied as the preliminary study in order to design cosmic-ray shielding material. Specially, Soft Magnetic Material, known to be effective in EMP and radiation shielding, has been investigated to check if the material would be applicable to cosmic-ray shielding. In this work, thermal neutron shielding experiment was conducted and the Monte Carlo N-Particle(MCNP) was applied to employ skymap.dat, which is cosmic-ray data embedded in MCNP. As a result, polyethylene, borated polyethylene, and carbon nano tube, containing carbon or hydrogen, have been found to be effective in reduction of neutron flux below 20 MeV (including thermal, epithermal, evaporation). In contrast, the materials composed of iron such as SS316 and Soft Magnetic Material show a good shielding performance in the cascade energy range (above 20 MeV). Since Soft Magnetic Material is consisting of 13% of boron, it can also decrease thermal neutron flux, so it is expected that it would show a significant reduction on the entire range of neutron energy if the Soft Magnetic Material is used with hydrogen and carbon, so called low Z material.

The Short Circuit Analysis of a Simplified Magnetic Shielding Type High-Tc Superconducting Fault Current Limiter (단순화된 자기차폐형 고온초전도한류기 단락 특성 해석)

  • 이찬주;이승제;장미혜;현옥배;최효상;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.97-100
    • /
    • 1999
  • Nowadays the high-Tc Superconducting Fault current Limiter (SFCL) is one of the superconducting devices which are very closed to commercialization. The most popular model of High-Tc SFCL is a magnetic shielding type. A superconductor of magnetic shielding type SFCL can be stable in the superconducting state, because there is no contact between the superconductor and the normal conductor. But this model needs large place to set up and in a fault condition, mechanical vibrations may happen to damage the superconductor or total device. In this paper, to solve these problems, the simplified model of magnetic shielding type SFCL was introduced.

  • PDF

The Study on Current Limiting Characteristic Analysis of Magnetic Shielding Type Fault Current Limiter

  • Lee, Jae;Lim, Sung-Hun;Kang, Hyeon-Gon;Ko, Seok-Cheol;Han, Byoung-Sung
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.235-240
    • /
    • 2002
  • In this paper, we investigated the current limiting characteristic in the magnetic shielding type fault current limiter(MSFCL). The circuit analysis was executed by using finite differential method(FDM). This paper suggests that the current limiting performance can be achieved in two ways (resistive and inductive one), according to design parameter. By comparing current limiting characteristics in two ways and surveying the important parameters which determine the operational way after fault occurs in the design of MSFCL, it is shown that the magnetic shielding type fault current limiter can be operated in either resistive or inductive way.

  • PDF