• Title/Summary/Keyword: magnetic resonance imaging measurement

Search Result 151, Processing Time 0.028 seconds

Imaging Technologies for Nondestructive Measurement of Internal Properties of Agricultural Products: A Review

  • Ahmed, Mohammed Raju;Yasmin, Jannat;Lee, Wang-Hee;Mo, Changyeun;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.42 no.3
    • /
    • pp.199-216
    • /
    • 2017
  • Purpose: This study reviewed the major nondestructive measurement techniques used to assess internal properties of agricultural materials that significantly influence the quality, safety, and value of the products in markets. Methods: Imaging technologies are powerful nondestructive analytical tools that possess specific advantages in revealing the internal properties of products. Results: This review was exploring the application of various imaging techniques, specifically, hyperspectral imaging (HSI), magnetic resonance imaging (MRI), soft X-ray, X-ray computed tomography (XRI-CT), thermal imaging (TI), and ultrasound imaging (UI), to investigate the internal properties of agricultural commodities. Conclusions: The basic instruments used in these techniques are discussed in the initial part of the review. In the context of an investigation of the internal properties of agricultural products, including crops, fruits, vegetables, poultry, meat, fish, and seeds, various extant studies are examined to understand the potential of these imaging technologies. Future trends for these imaging techniques are also presented.

Peach & Pit Volume Measurement and 3D Visualization using Magnetic Resonance Imaging Data (자기공명영상을 이용한 복숭아 및 씨의 부피 측정과 3차원 가시화)

  • 김철수
    • Journal of Biosystems Engineering
    • /
    • v.27 no.3
    • /
    • pp.227-234
    • /
    • 2002
  • This study was conducted to nondestructively estimate the volumetric information of peach and pit and to visualize the 3D information of internal structure from magnetic resonance imaging(MRI) data. Bruker Biospec 7T spectrometer operating at a proton reosonant frequency of 300 MHz was used for acquisition of MRI data of peach. Image processing algorithms and visualization techniques were implemented by using MATLAB (Mathworks) and Visualization Toolkit(Kitware), respectively. Thresholding algorithm and Kohonen's self organizing map(SOM) were applied to MRI data fur region segmentation. Volumetric information were estimated from segemented images and compared to the actual measurements. The average prediction errors of peach and pit volumes were 4.5%, 26.1%, respectively for the thresholding algorithm. and were 2.1%, 19.9%. respectively for the SOM. Although we couldn't get the statistically meaningful results with the limited number of samples, the average prediction errors were lower when the region segmentation was done by SOM rather than thresholding. The 3D visualization techniques such as isosurface construction and volume rendering were successfully implemented, by which we could nondestructively obtain the useful information of internal structures of peach.

Method of tumor volume evaluation using magnetic resonance imaging for outcome prediction in cervical cancer treated with concurrent chemotherapy and radiotherapy

  • Kim, Hun-Jung;Kim, Woo-Chul
    • Radiation Oncology Journal
    • /
    • v.30 no.2
    • /
    • pp.70-77
    • /
    • 2012
  • Purpose: To evaluate the patterns of tumor shape and to compare tumor volume derived from simple diameter-based ellipsoid measurement with that derived from tracing the entire tumor contour using region of interest (ROI)-based 3D volumetry with respect to the prediction outcome in cervical cancer patients treated with concurrent chemotherapy and radiotherapy. Materials and Methods: Magnetic resonance imaging was performed in 98 patients with cervical cancer (stage IB-IIIB). The tumor shape was classified into two categories: ellipsoid and non-ellipsoid shape. ROI-based volumetry was derived from each magnetic resonance slice on the work station. For the diameter-based surrogate "ellipsoid volume," the three orthogonal diameters were measured to calculate volume as an ellipsoid. Results: The more than half of tumor (55.1%) had a non-ellipsoid configuration. The predictions for outcome were consistent between two volume groups, with overall survival of 93.6% and 87.7% for small tumor (<20 mL), 62.9% and 69.1% for intermediate-size tumor (20-39 mL), and 14.5% and 16.7% for large tumors (${\geq}$40 mL) using ROI and diameter based measurement, respectively. Disease-free survival was 93.8% and 90.6% for small tumor, 54.3% and 62.7% for intermediate-size tumor, and 13.7% and 10.3% for large tumor using ROI and diameter based method, respectively. Differences in outcome between size groups were statistically significant, and the differences in outcome predicted by the tumor volume by two different methods. Conclusion: Our data suggested that large numbers of cervical cancers are not ellipsoid. However, simple diameter-based tumor volume measurement appears to be useful in comparison with ROI-based volumetry for predicting outcome in cervical cancer patients.

[ $T_2$ ]-relaxation Time Measurement of ex vivo $^1H$ MR Metabolite Peaks for Evaluation of Human Stomach Cancer

  • Mun Chi-Woong;Choi Ki-Sueng;Shin Oon-Jae;Yang Young-Ill;Chang Hee-Kyung;Hu Xiaoping;Eun Chung-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.2
    • /
    • pp.53-58
    • /
    • 2006
  • In this study, transverse relaxation time (T2) measurement and the evaluation of the characteristics of the spectral peak related to stomach tissue metabolites were performed using ex vivo proton magnetic resonance spectroscopic imaging (MRSI) at 1.5-T MRI/S instruments. Thirty-two gastric tissues resected from 12 patients during gastric cancer surgery, of which 19 were normal tissue and 13 were cancerous tissue, were used to measure the $T_2$ of the magnetic resonance spectroscopy (MRS) peaks. The volume of interest data results from the MRSI measurements were extracted from the proper muscle (MUS) layer and the composite mucosa/submucosa (MC/SMC) layer and were statistically analyzed. MR spectra were acquired using the chemical shift imaging (CSI) point resolved spectroscopy (CSI-PRESS) technique with the parameters of pulse repetition time (TR) and echo times (TE) TR/(TE1,TE2)=1500 msec/(35 msec, 144 msec), matrix $size=24{\times}24$, NA=1, and voxel $size=2.2{\times}2.2{\times}4mm^3$. In conclusion, the measured $T_2$ of the metabolite peaks, such as choline (3.21ppm) and lipid (1.33ppm), were significantly decreased (p<0.01 and p<0.05, respectively) in the cancerous stomach tissue.

Distortion Correction in Magnetic Resonance Images on the Measurement of Muscle Cross-sectional Area (자기공명영상을 이용한 근육 단면적 측정법의 활용을 위한 영상왜곡보정)

  • Hong, Cheol-Pyo;Lee, Dong-Hoon;Park, Ji-Won;Han, Bong-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.66-72
    • /
    • 2012
  • Purpose: The purpose of this study is to explore the importance of the image distortion correction in the cross sectional area measurement for the iliopsas muscle, tensor fasciae latae muscle, gluteus maximus muscle and the knee extensor muscles, by using (magnetic resonance imaging) MRI. Methods: This study was performed using an open 0.32T MRI system. To estimate the image distortion, T1 images for an AAPM homogeneity/linearity phantom were acquired, and the region in which the maximum geometric distortion was less than or equal to the pixel size (1.6 mm) of the images, it was defined as the distortion correction-free region. The T2 images for a human subject's pelvis and thigh in normal positions were obtained. Then, after the regions of interest in the pelvis and thigh were moved into the distortion correction-free region, T2 images for the pelvis and thigh were scanned with the same imaging parameters used in the previous T2 imaging. The cross-sectional areas were measured in the two T2 images that were obtained in the normal position, and the distortion correction-free region, as well as the area error caused by geometric image distortion was calculated. Results: The geometrical distortion is gradually increased, from the magnet center to the outer region, in axial and coronal plane. The cross-sectional area error of gluteus maximus muscle and the knee extensors was as high as 9.27% and 3.16% in before and after distortion correction, respectively. Conclusion: The cross-sectional area of the muscles that suffered from the geometrical distortion is necessary to correct for the estimation of the intervention.

Overview of Arterial Spin Labeling Perfusion MRI (동맥스핀표지 관류 자기공명영상의 개요)

  • Kang, Sung-Jin;Han, Man-Seok
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.4
    • /
    • pp.145-152
    • /
    • 2017
  • The arterial spin labeling (ASL) is a magnetic resonance imaging (MRI) method that can evaluate tissue perfusion using blood in the body. The characteristic of non-invasive examinations without contrast agents and the quantitative measurement of perfusion volume is possible, which are increasingly being used for clinical and research purposes. Up to the present, The ASL method has lower SNR than the perfusion imaging method using contrast agent and because optimization of various parameter in the imaging process is difficult, Which may result in measurement errors. To improve this, ASL methods using various technologies are introduced. This paper briefly introduces the outline of ASL, its features in imaging process, various techniques, and clinical application.

Magnetic Resonance Imaging of the Temporomandibular Joint (측두하악관절의 핵자기공명영상 촬영에 관한 연구)

  • Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.407-410
    • /
    • 1999
  • Purpose; To find out the best imaging parameters for the diagnosis of disc in MRI imaging. Materials and methods; The diagnostic quality of the disc among the Tl, PD and T2 images of same patients02 joints, 223 images) was compared by visual(I-IV grades) and gray level measurement (pre- and infra-discal area) method. Results; PD images showed best results with 43.7% of the images belonging to grade III (good) and with statistically significant higher difference of the gray levels at pre- and infra-discal areas. But there were no grade N (excellent) images. Conclusions; PD images are best method among Tl. PD and T2 images in diagnosing the disc but since there were no excellent images further imaging parameters should be studied for better images.

  • PDF

Improvement of Gibb's Phenomena in Fast Spin Echo Imaging Using Symmetric Echo Arrangement and Filtering (대칭적 에코 배치 및 필터링을 통한 Fast Spin Echo 영상에서의 Gibb's 현상 개선)

  • 안창범;김치영;오창현;신진교
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.79-85
    • /
    • 1997
  • Fast spin echo imaging utilizes multiple spin echoes to encode multiple k-space lines instead of multiple $T_2-weighted$ images. As results, intensities in k-space data are varying according to T2 decay, which generates Gibb's artifact in the reconstructed image. The echo time for e encoding dc block determines contrast, as is specified by the effective echo time, however, all location of other echoes to different k-space frequency blocks in fast spin echo imaging is not f fully investigated. In this study, symmetric arrangement of multiple echoes in k-space is investigated to reduce Gibb's artifact. Design of filters based on the measurement of multiple e echo intensities is also proposed in two stage manner, i.e., equalization and filtering. From s simulation and experiment, it was observed that Gibb's phenomena were substantially reduced b by the proposed methods.

  • PDF

Morphologic Assessment of Corpus Callosum in the Patient of Alzheimer Disease using Magnetic Resonance Imaging

  • Seoung, Youl-Hun;Choe, Bo-Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.13 no.2
    • /
    • pp.84-95
    • /
    • 2009
  • The purpose of this study was to evaluate the usefulness of the measurement of corpus callosum (CC) size in the Alzheimer patient by using magnetic resonance (MR) midsagittal image. We performed MR scanning in 20 normal high age group, and in 20 mild cognitive impairment (MCI) group, and in 20 Alzheimer disease (AD) group. The following parameters were employed in AD group: TRITE/FA 6650ms/66ms/$90^{\circ}$, NEX 2, Thickness/Gap 2/0, FOV 220mm. The magnetic field strength was used at 3.0 Tesla. We selected midsagittal image of the brain by using view forum program, measured CC size, which were anteroposterior length, diameter of genu, body, narrowing portion, and splenium. The present study demonstrates that CC size of Alzheimer disease can be useful for clinical assessment concerning the diameter of genu, body, and splenium.