• 제목/요약/키워드: magnetic resonance image

검색결과 944건 처리시간 0.032초

자기 공명 영상을 이용한 악관절 기능 장애에 관한 연구 (A STUDY ON TEMPOROMANDIBULAR JOINT DYSFUNCTION USING MAGNETIC RESONANCE IMAGING)

  • 이문배;김재덕
    • 치과방사선
    • /
    • 제22권1호
    • /
    • pp.29-37
    • /
    • 1992
  • The temporomandibular joint was evaluated using magnetic resonance imaging using a urface coil in 11 patients having reciprocal clicking or locking and compared with the normal joint in five subjects. Serial multisection 3㎜-thick parasagittal, paracoronal, and axial image on both closing and opening mouth were obtained with a 1.5 Tesla MR system and surface coil using CSMEMP, GRASS, MPGR, powerful extensions of fast imaging that is currently under clinical evaluation. MR images obtained were analized correlating with the theory of internal derangement. The obtained results were as follows: 1. The serial findings of structures in joint were determined on the serially sectioned images of joint with reciprocal clicking or locking by CSMEMP and MPGR on closing mouth. 2. The delta shaped white images of synovial fluid in the glenoid fossa and on the posterior surface of condyle were revealed on the parasagittal images by MPGR on opening mouth as in the normal joints. 3. The white image of joint fluid surrounding meniscus was recognized on the paracoronal image by GRASS on opening mouth as in the normal joints. 4. In joints having temporomandibular dysfunction the smooth image of displaced meniscus was recognized, but otherwise in the normal joints the image of muscle was noted on the paracoronal image sectioned at the anterior portion of condyle by GRASS. 5. The more thickened fascial plane between superior and inferior belly of lateral pterygoid muscle was not recognizable in joints having temporomandibular dysfunction than in the normal joints.

  • PDF

뇌열 1예의 기능적 자기공명영상과 경두부 자기자극 (Functional-Magnetic Resonance Imaging and Transcranial Magnetic Stimulation in a Case of Schizencephaly)

  • 변우목;한봉수;이재교;장용민
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권1호
    • /
    • pp.14-19
    • /
    • 2000
  • 목적 : 뇌열환자에서 기능적 자기공명영상과 경두부 자기자극을 이용하여 뇌기능을 지도화하고자하였다. 대상 및 방법: 자기공명영상에서 우측 대뇌반구에 뇌열 소견이 있으며 좌측 편측부전마비를 보인 28세 남자환자를 대상으로 기능적 자기공명영상과 경두부 자기자극을 시행하였다. 임상적으로 좌측 손의 운동기능은 감소되어 있었고, 우측 손의 운동기능은 정상범주에 속하였다. 뇌기능적 자기공명영상은 EPI 기법을 이용하였고 운동자극은 1-2 Hz의 주기로 손가락을 아래위로 구부리게 하는 운동을 시행하였고 15초의 휴식기와 15초의 운동기를 반복하여 절편당 60 개의 영상을 획득하였다. 두부자기자극은 지름 90mm의 원형 자성자극기를 이용하여 maximal out-put의 80%로 자극하여 양측 단무지 외 전근에서 유발된 운동유발전위의 잠시와 진폭을 구하였다. 결과: 기능적 자기공명영상을 시행한 결과 정상적인 우측손의 운동자극시에 좌측 운동피질이 활성화되었고 좌측손의 운동자극시에는 좌측운동피질, 좌측 부가운동영역, 그리고 자측 전운동영역에 활성화소견이 나타났다. 두부자기자극에서는 우측 대뇌반구에서는 한군데에서도 운동유발 전위가 발생되지 않았다. 좌측 대뇌반구에서는 5군데에서 운동유발전위가 유발되었으며 모두 양측 단무지 외 전근에서 운동유발전위가 유발되었다. 양손에서 운동유발전위의 잠시 , 진폭 모양이 유사하였다. 결론: 뇌열환자의 손운동기능의 피지도화는 기능적 자기공명영상과 두부자기자극을 이용하여 성공적으로 시행할 수 있었다. 뇌열환자의 동측 운동경로는 동일한 운동피질로부터 기원한 동측피질척수로에 의한 것으로 추정된다.

  • PDF

종합병원 자기공명단층촬영유니트에 관한 건축계획적 연구 (A Study on the Architectural Planning of the Magnet Resonance Imaging Unit in General Hospital)

  • 윤우용;채철균
    • 한국실내디자인학회논문집
    • /
    • 제15권4호
    • /
    • pp.89-96
    • /
    • 2006
  • Magnetic Resonance Imaging (MRI) scanner is the device to draw an image of conditions and the spread of various tissue in the body. It is used by making the patient into rounded superconductor and using high frequency which cause resonances. It uses superconduction magnet and high frequency that is non-ionizing radiation so can acquire biochemical, physical, and functional information of tissue. It is also very useful because it can scan tomography from many different angles to diagnose disease of a nervous system, the heart, and a skeletal structure. It also has advantages of that there is no risk of radiation exposure and the ability of observation on organizations such as brains, livers and the spinal cord of people. Since these features, the rate of use has been increased accordingly more considerations of the security are required when it plans. The weight of devices and the cover problem of the strong magnetic field which is occurred by magnetic resonance at the time of diagnosis can cause very important structure problems and architectural condition. That also the recent tendency which needs stronger equipment means that planning of the MRI unit should generally aim at purposing of the proximity for the device maintenance and up-grade and of further expansion. However there are not enough studies and data on the magnet resonance imaging in domestic hospitals. According to these reasons, this study has an object of indicating basic data on MRI unit plan standard and alternative proposals.

인($^{31}$P) 자기공명분광법을 사용하여 사립체 근질병환자와 정상인과의 대사물질 비교조사 (Metabolic Abnormalities in Patients with Mitochondrial Myopathy Evaluated by In Vivo $^{31}$P Magnetic Resonance Spectroscopy)

  • Bo-Young Choe
    • Investigative Magnetic Resonance Imaging
    • /
    • 제2권1호
    • /
    • pp.89-95
    • /
    • 1998
  • 목적 : 인($^{31}P$) 자기공명분광법을 사용하여 사립체 근병(mitochondria myopathy) 환자의 대퇴부 근조직의 대사물질의 변화를 정상인과 비교조사하였다. 대상 및 방법 : 사립체 근병환자 10명과 정상인 10명을 대상으로 1.5T MRI/MRS 장비를 사용하여 인($^{31}P$) 자기공명분광법을 적용하였다. 오른쪽 대퇴부위의 근조직에 $4{\;}{\times}{\;}4{\;}{\times}4{\;}cm^{3}$ 의 관심부위 (volume of interest ; VOI)를 선정하여 image selected in vivo spectroscopy (ISIS)를 저용하였다. 인대사불질의 정\ulcorner분석은 Marquart algorithm을 사용하였다. 결과 : 사립체 근병환자의 특징은 정상인과 비교하여 Pe/PCr 대사비율이 상당히 증가하고 (P=0.003), ATP/PCr 대사비율은 상당히 감소하였다(p=0.004). 특히 ATP 중 ${\beta}-ATP/PCr$ 비율의 변화가 가장 심하게 나타났다. 환자군과 정상군의 pH 차이는 통계학적으로 큰 의의는 없었다. 결론 : 인($^{31}P$) 자기 공명분광법은 사립체 근병환자의 대퇴부 근조직의 ATP/PCr 과 Pi/PCr 대사비율을 토대로 유용한 임상 평가 자료를 제공하고, 따라서 근대사물질의 질병을 이해하는데 도움을 줄 것으로 사료된다.

  • PDF

Prior to Breast MRI Guidelines in Korea, Where Were We?

  • Hwang, Cheong Hoon;Rho, Miribi;Lee, Minah;Kim, Ga Ram;Park, Vivian Youngjean;Yoon, Jung Hyun;Kim, Min Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권1호
    • /
    • pp.35-42
    • /
    • 2021
  • Purpose: To evaluate and analyze the adequacy of breast magnetic resonance imaging (MRI)s taken before publication of the 2018 recommendation in South Korea. Materials and Methods: We enrolled 87 cases of breast MRIs, from January 2010 to November 2013, taken at external hospitals in the study. Breast MRI protocol elements are divided into three categories based on the recommendation by the Breast Imaging Study Group of the Korean Society of Magnetic Resonance: (1) Essential elements for breast MRI protocol; (2) Element to consider when evaluating imaging quality; and (3) Optional element for breast MRI protocol. Also, we divided enrolled cases into three groups based on their conducting locations -- (1) Primary hospitals, (2) Secondary hospitals, and (3) Tertiary hospitals-and analyzed them for the adequacy of imaging protocols based on the 2018 recommendation. We used a Chi-square test and Fisher's exact test to identify differences between categorical variables. Results: Over 98% of the criteria for 'essential elements for breast MRI protocol' were satisfied when compared with the 2018 Recommendation. Over 96% of the criteria for 'elements to consider when evaluating imaging quality' were also satisfied, except for the slice thickness (83.9%). Optional elements for breast MRI protocol were satisfied with various percentages. There were no statistically significant differences between groups of tertiary, secondary, and primary hospitals; however, 3 tesla of MRI (P = 0.04), subtraction image protocol (P = 0.032), and DWI protocol (P = 0.03) were used more frequently in the tertiary hospitals than in the others. Conclusion: We found that the categories of 'essential elements' and 'elements to consider when evaluating imaging quality' were satisfied at 98% and 96%, respectively, when compared with the 2018 Recommendation by the Breast Imaging Study Group of the Korean Society of Magnetic Resonance.

Two Paralleled Four Quadrant DC Chopper for Gradient Coil Magnetic Fields in MRI System

  • Park, Hyung-Beom;Mun, Sang-Pil;Park, Han-Seok;Woo, Kyung-Il
    • 조명전기설비학회논문지
    • /
    • 제23권11호
    • /
    • pp.22-27
    • /
    • 2009
  • This paper presents a two-paralleled four quadrant DC chopper type PWM power conversion circuit in order to generate a gradient magnetic field in the Magnetic Resonance Imaging (MRI) system. This circuit has 8-IGBTs at their inputs/outputs to realize further high-power density, high speed current tracking control, and to get a low switching ripple amplitude in a controlled current in the Gradient Coils (GCs). Moreover, the power conversion circuit has to realize quick rise/fall response characteristics in proportion to various target currents in GCs. It is proposed in this paper that a unique control scheme can achieve the above objective DSP-based control system realize a high control facility and accuracy. It is proved that the new control system will greatly enlarge the diagnostic target and improve the image quality of MRI.

측두하악관절의 핵자기공명영상 촬영에 관한 연구 (Magnetic Resonance Imaging of the Temporomandibular Joint)

  • 나경수
    • 치과방사선
    • /
    • 제29권2호
    • /
    • pp.407-410
    • /
    • 1999
  • Purpose; To find out the best imaging parameters for the diagnosis of disc in MRI imaging. Materials and methods; The diagnostic quality of the disc among the Tl, PD and T2 images of same patients02 joints, 223 images) was compared by visual(I-IV grades) and gray level measurement (pre- and infra-discal area) method. Results; PD images showed best results with 43.7% of the images belonging to grade III (good) and with statistically significant higher difference of the gray levels at pre- and infra-discal areas. But there were no grade N (excellent) images. Conclusions; PD images are best method among Tl. PD and T2 images in diagnosing the disc but since there were no excellent images further imaging parameters should be studied for better images.

  • PDF

고속 Burst 영상법 - pulse sequence 중심으로 (Fast Burt Imaging)

  • 강호경;노용만
    • Investigative Magnetic Resonance Imaging
    • /
    • 제3권1호
    • /
    • pp.13-19
    • /
    • 1999
  • MRI imaging provides many benefits such as noninvasive, 3-dimensional imaging capabilities. But it has relatively serious drawback that is the long data collection time, compared with other imaging modality. Many studies have been performed for fast MR imaging. But EPI and SEPI (4-6) are required to expensive hardware. In this paper, we introduce to Burst imaging technique. It can reduce imaging time by use of a mulitple RF excitation technique. Further it is easily implemented to the normal MRI system. But a pixel profile in the conventional burst sequence is so poor that excited area by burst sequence is a small portion of a pixel. This causes poor signal to noise ratio in burst image. therefore frequency sweeping of RF pulse for burst imaging sequence is proposed to improve pixel profile. A burst pulse train is shaped by liner or nonlinear frequency sweeping function so that all the spins within a pixel are excited, thereby improving the signal to noise ratio. It also shows that the pixel profiles are dependent on how frequency sweep is made. Computer simulations with Bloch equation and experimental results obtained using a 1.0 T NMR imaging system are presented.

  • PDF

A NOTE ON OPTIMAL RECONSTRUCTION OF MAGNETIC RESONANCE IMAGES FROM NON-UNIFORM SAMPLES IN k-SPACE

  • Lee, June-Yub
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제14권1호
    • /
    • pp.35-42
    • /
    • 2010
  • A goal of Magnetic Resonance Imaging is reproducing a spatial map of the effective spin density from the measured Fourier coefficients of a specimen. The imaging procedure can be done by inverse Fourier transformation or backward fast Fourier transformation if the data are sampled on a regular grid in frequency space; however, it is still a challenging question how to reconstruct an image from a finite set of Fourier data on irregular points in k-space. In this paper, we describe some mathematical and numerical properties of imaging techniques from non-uniform MR data using the pseudo-inverse or the diagonal-inverse weight matrix. This note is written as an easy guide to readers interested in the non-uniform MRI techniques and it basically follows the ideas given in the paper by Greengard-Lee-Inati [10, 11].