• Title/Summary/Keyword: magnetic pulse forming

Search Result 22, Processing Time 0.026 seconds

A Fundamental Study on Magnetic Pulse Forming with Bar Forming Coil (Bar 성형 코일을 이용한 전자기 성형에 관한 기초 연구)

  • Shim, Ji-Yeon;Kang, Bong-Yong;Park, Dong-Hwan;Kim, Ill-Soo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.3
    • /
    • pp.292-297
    • /
    • 2011
  • MPF(Magnetic pulse forming) process refers to the high velocity and high strain rate deformation of a low-ductility materials driven by electromagnetic forces that are generated by the rapid discharge current through forming coil. The goal of this study was to find the characteristics of dynamic behavior of workpiece and to find the main design process on MPF using bar forming coil. For these purposes, thin Al5053 sheet were used for the experiment. The measured strain data were analyzed by developed electromagnetic FE-model. The main design parameter is location of coil, electromagnetic force. In case of the bar forming coil, there exists the dead regions where the low electromagnetic force applied on the workpiece.

Study on Design Parameters that Affect the Forming Force of the Magnetic Pulse Forming Device (자기 펄스 성형장치의 성형력에 영향을 미치는 설계 파라미터에 관한 연구)

  • Lee, Man Gi;Yi, Hwa Cho;Kim, Jin Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.3
    • /
    • pp.79-82
    • /
    • 2015
  • The design parameter study about the magnetic pulse forming is performed using finite element analysis with MAXWELL. The first case of design parameters is about the initial charging voltage and the capacitance and the second case of design parameters are about the winding turns and the spacing of electromagnetic coil. The 3D finite element model of electromagnetic forming system is created and the magnetic force is calculated. The effects of design parameters on the magnetic forming force are investigated.

Pulse forming's switching control adopted a Transcranial Magnetic Stimulation Biomedical engineering, Dongju College University (펄스포밍의 스위칭 제어기술을 적용한 경두개 자기자극장치)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.729-736
    • /
    • 2010
  • In this study, a magnetic stimulation (MS) device with controllable pulse forming technology and pulse shape (MS) is described. The MS device uses an IGBT with appropriate snubbers to switch coil currents up to 6 kA, enabling pulse forming technology control from 5 s to over 100 s. The induced electric field pulses use 2% - 34% less energy and generate 57% - 67% less coil heating compared to matched conventional cosine pulses. MS is used to stimulate rhesus monkey motor cortex in vivo with pulse forming technology of 20 to 100 s, demonstrating the expected decrease of threshold pulse amplitude with increasing pulse forming technology. The technological solutions used in the MS prototype can expand functionality, and reduce power consumption and coil heating in MS, enhancing its research and therapeutic applications.

A Study on the Design of Branch Conductor in the Magnetic Pulse Generator (자기 펄스 발생기의 연결 도체 설계에 관한 연구)

  • SUH, JUBA
    • Journal of Industrial Technology
    • /
    • v.9
    • /
    • pp.101-107
    • /
    • 1989
  • The magnetic forming system must be able to store very important electric energy, several tens kilojoules, and flow this energy through the forming coil within some hundreds microseconds. So several hundreds kiloamperes of current can flow through the branch conductor. For the good performance of this type of machine, internal impedance must be minimized. By the computation of distribution of current inside the conductors using integral equation method, we can obtain the inductance and resistance of some dispositions of branch conductors and by comparison obtain some principles for the design of branch conductors in the high power magnetic pulse generator.

  • PDF

3 Stage 2 Switch Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.234-239
    • /
    • 2011
  • Transcranial magnetic stimulation utilizes the method of controlling applied time and changing pulse by output pulse through power density control for diagnosis purposes. Transcranial magnetic stimulation can also be used in cases where diagnosis and treatment are difficult since output pulse shape can be changed. As intensity, pulse range, and pulse shape of the stimulation pulse must be changed according to lesion, the existing sine wave-shaped stimulation treatment pulse poses limitations in achieving various treatments and diagnosis. This study actualized a new method of transcranial magnetic stimulation that applies a 3 Stage 2 Switch( power semiconductor 2EA) for controlling pulse repetition rate by achieving numerous switching control of stimulation coil. Intensity, pulse range, and pulse shape of output can be freely changed to transform various treatment pulses in order to overcome limitations in stimulation treatment presented by the previous sine wave pulse shape. The method of freely changing pulse range by using 3 Stage 2 Switch discharge method is proposed. Pulse shape, composed of various pulse ranges, was created by grafting PFN (Pulsed Forming Network) through AVR AT80S8535 one-chip microprocessor technology, and application in transcranial magnetic stimulation was achieved to study the output characteristics of stimulation treatment pulse according to delaying time of the trigger signal applied in section switch.

전자기 성형에서의 테이퍼진 지속집중기의 자기압력에 관한 연구

  • Choe, Jae-Chan;Jo, Yong-Cheol;Lee, Jong-Su;Hwang, Un-Seok;Kim, Nam-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.7 no.2
    • /
    • pp.14-27
    • /
    • 1990
  • Electromagnetic Pulse Forming is the one of the high velocity forming method. When the electric energy which is charged in the capacitor bank is suddenly discharged into the electromagnetic coil, the high magnetic field occurs at the airgap between the electromagnetic coil and workpiece. Thus we can obtain the high electromagnetic pressure, which is proportional to the square of magnetic flux density. This is the basic principle of the electromagnetic pulse forming. In this paper, the equivalent L-R-C circuit is derived by computing the magnetic field and its loss of the total system. Thus, the values of the magnetic flux density and pressure can be obtained from the equation of this circuit. As a result, the computed and measured values of the maximum magnetic flux density and pressure are compared and the characteristics of the tapered field shaper are further discussed as follows; 1) The strength of magnetic flux density and pressure can be controlled by the charged energy and the size of the airgap between the inner field shaper and the workpiece. 2) During the design of the tapered field shaper, the penetration of the magnetic flux through the sharp edge should be considered.

  • PDF

The simulator loop probe style magnetic stimulation design for a nervous system treatment (신경계 치료를 위한 루프 프로브형 자기자극기의 시뮬레이터)

  • Kim, Whi Young
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.3
    • /
    • pp.29-37
    • /
    • 2009
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Simulator and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of loop object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment digital forming etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Neuralgia, muscular disease and Altzheimer, with stroke etc. is becoming the matter of concern and interest which disease of adult etc. it is same is important. And the melancholia in compliance with the modern direction of a ceremony which is complicated and garrulous, trillion it will cry and symptoms, it is a tendency where the emotional obstacle etc. nervous psychiatric disorder patient is increasing at class speed. But currently the applicator it will be able to treat like this disease almost it is a condition which is wholly lacking. Consequently like this disease it used magnetic stimulation and it diagnosed and the equipment it will be able to treat plan and it embodied.

Full Wave Cockroft Walton Application for Transcranial Magnetic Stimulation

  • Choi, Sun-Seob;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.246-252
    • /
    • 2011
  • A high-voltage power supply has been built for activation of the brain via stimulation using a Full Wave Cockroft-Walton Circuit (FWCW). A resonant half-bridge inverter was applied (with half plus/half minus DC voltage) through a bidirectional power transistor to a magnetic stimulation device with the capability of producing a variety of pulse forms. The energy obtained from the previous stage runs the transformer and FW-CW, and the current pulse coming from the pulse-forming circuit is transmitted to a stimulation coil device. In addition, the residual energy in each circuit will again generate stimulation pulses through the transformer. In particular, the bidirectional device modifies the control mode of the stimulation coil to which the current that exceeds the rated current is applied, consequently controlling the output voltage as a constant current mode. Since a serial resonant half-bridge has less switching loss and is able to reduce parasitic capacitance, a device, which can simultaneously change the charging voltage of the energy-storage condenser and the pulse repetition rate, could be implemented. Image processing of the brain activity was implemented using a graphical user interface (GUI) through a data mining technique (data mining) after measuring the vital signs separated from the frequencies of EEG and ECG spectra obtained from the pulse stimulation using a 90S8535 chip (AMTEL Corporation).

Starting Current Application for Magnetic Stimulation

  • Choi, Sun-Seob;Bo, Gak-Hwang;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.51-57
    • /
    • 2011
  • A power supply for magnetic-stimulation devices was designed via a control algorithm that involved a start current application based on a resonant converter. In this study, a new power supply for magnetic-stimulation devices was designed by controlling the pulse repetition frequency and pulse width. The power density could be controlled using the start-current-compensation and ZCS (zero-current switching) resonant converter. The results revealed a high-repetition-frequency, high-power magnetic-stimulation device. It was found that the stimulation coil current pulse width and that pulse repetition frequency could be controlled within the range of 200-450 ${\mu}S$ and 200-900 pps, respectively. The magnetic-stimulation device in this study consisted of a stimulation coil device and a power supply system. The maximum power of the stimulation coil from one discharge was 130 W, which was increased to 260 W using an additional reciprocating discharge. The output voltage was kept stable in a sinusoidal waveform regardless of the load fluctuations by forming voltage and current control using a deadbeat controller without increasing the current rating at the starting time. This paper describes this magnetic-stimulation device to which the start current was applied.

Numerical Simulation of Thin Sheet Metal Forming Process using Electromagnetic Force (전자기력을 이용한 박판 성형공정의 해석적 연구)

  • Seo, Y.H.;Heo, S.C.;Ku, T.W.;Song, W.J.;Kang, B.S.;Kim, J.
    • Transactions of Materials Processing
    • /
    • v.17 no.1
    • /
    • pp.35-45
    • /
    • 2008
  • Electromagnetic Forming (EMF) technology such as magnetic pulse forming, which is one of the high velocity forming methods, has been used for the joining and forming process in various industry fields. This method could be derived a series of deformation of sheet metal by using a strong magnetic field. In this study, numerical approach by finite element simulation of the electromagnetic forming process was presented. A transient electromagnetic finite element code was used to obtain the numerical model of the time-varying currents that are discharged through the coil in order to obtain the transient magnetic forces. Also, the body forces generated in electromagnetic field were used as the loading condition to analyze deformation of thin sheet metal workpiece using explicit dynamic finite element code. In this study, after finite element analysis for thin sheet metal forming process with free surface configuration was performed, analytical approach for a dimpled shape by using EMF was carried out. Furthermore, the simulated results of the dimpled shape by EMF were compared with that by a conventional solid tool in view of the deformed shape. From the results of finite element analysis, it is confirmed that the EMF process could be applied to thin sheet metal forming.