• Title/Summary/Keyword: magnetic noise

Search Result 1,054, Processing Time 0.024 seconds

Noise Level Evaluation According to Slice Thickness Change in Magnetic Resonance T2 Weighted Image of Multiple Sclerosis Disease (다발성 경화증 질환의 자기공명 T2 강조영상에서 단면 두께 변화에 따른 잡음 평가)

  • Hong, Inki;Park, Minji;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.327-333
    • /
    • 2021
  • Magnetic resonance imaging(MRI) uses strong magnetic field to image the cross-section of human body and has excellent image quality with no risk of radiation exposure. Because of above-mentioned advantages, MRI has been widely used in clinical fields. However, the noise generated in MRI degrades the quality of medical images and has a negative effect on quick and accurate diagnosis. In particular, examining a object with a detailed structure such as brain, image quality degradation becomes a problem for diagnosis. Therefore, in this study, we acquired T2 weighted 3D data of multiple sclerosis disease using BrainWeb simulation program, and used quantitative evaluation factors to find appropriate slice thickness among 1, 3, 5, and 7 mm. Coefficient of variation and contrast to noise ratio were calculated to evaluate the noise level, and root mean square error and peak signal to noise ratio were used to evaluate the similarity with the reference image. As a result, the noise level decreased as the slice thickness increased, while the similarity decreased after 5 mm. In conclusion, as the slice thickness increases, the noise is reduced and the image quality is improved. However, since the edge signal is lost due to overlapped signal, it is considered that selecting appropriate slice thickness is necessary.

A Study on Analysis and Effect of Electronic Noise in an Inductive Displacement Sensor (유도형 변위 센서의 전기 노이즈 분석과 센서 성능에 미치는 영향 고찰)

  • 신우철;홍준희;이동주
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.379-384
    • /
    • 2003
  • Noise is a problem in many electronic circuits and active control system. Arising from spuriously coupled noise from other circuits, it corrupts the signal of interest and introduces an uncertainty into information it contains. In this paper, re have researched noise characteristics of the inductive displacement sensor which has been designed. n first present basic concept and characteristics of magnetic field-coupled noise in the sensor output signal. Then, n are present relation noise and sensor performances. Finally, we concentrate low noise design of a sensor driver and a signal detection circuit.

  • PDF

The evaluation of fracture characteristics and the analysis of stress distribution of ferromagnetic materials by Barkhausen noise method (자기적 비파괴 방법으로서의 Barkhausen Noise를 이용한 강자성체의 파괴인성 및 응력분포해석)

  • Kim, Dong-Won;Kwon, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1864-1866
    • /
    • 1999
  • The magnetic nondestructive test can be applied to evaluate the magnetic material characteristics and the fracture properties through the internal defects of SA-508 used in the pressure vessels of the nuclear power plants as the direct and accurate in-situ testing methods. The fracture toughness, yield strength and the stress distribution around the defects in the surface and sub-surface of magnetic materials can be directly estimated by Bark-hausen noise(BN) methods as NDT. The testing process of SA-508 by Barkhausen noise method was advanced by controlling the austenizing peak temperature and the time of maintenance at a constant austenizing peak temperature, therefore causing the variation of fracture toughness. Through above process. we can evaluate the variations of effective grain size and the correlation of effective grain size and FATT at each situation. And the stress distribution around the defects can be quantified nondestructively through Barkhausen method.

  • PDF

Low Frequency Noise Properties of YBCO SQUID Gradiometers (YBCO SQUID gradiometers의 저주파 잡음 특성 연구)

  • 황태종;김인선;김동호;박용기
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.68-73
    • /
    • 2002
  • We have fabricated YBCO SQUID 1st order gradiometers on $30^{\circ}$STO bicrystal substrate. The pickup coil size was 3.8mm$\times$3.8mm and baseline was 5mm. Three types of SQUID gradiometer were designed and tested for unshielded operation; solid pickup coil, pickup coil consisting of 4 parallel $ 50\mu\textrm{m}$-wide loops, and solid pickup coil with flux dam. We have investigated external magnetic field dependence of the SQUID gradiometers on the magnetic field noiseproperties. Significant increase of low frequency noise with the application of static field has been observed in the case of parallel and flux dam type pickup coil above threshold field of $1.3 \mu$T. Magnetic field noise at 1 Hz measured in the magnetically shielding room was 30, 165, 480 fTcm/sup -1/Hz/sup -1/2/ for solid type and slot type and parallel loops type, respectively.

  • PDF

Evaluation of 1Cr-1Mo-0.25V Steel Degradation Using Magnetic Barkhausen Noise (Magnetic Barkhausen Noise를 이용한 1Cr-1Mo-0.25V강의 열화도 평가)

  • Lee, J.M.;Ahn, B.Y.;Nam, Y.H.;Nahm, S.H.;Lee, S.S.;Lee, O.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.250-255
    • /
    • 2001
  • It is inevitable to evaluate the life of turbine rotor because the operating periods of power plants need to be extended. The magnetic methods utilizing Magnetic Barkhausen noise curve were applied to detect the degradation caused by thermal aging. The Magnetic property of material depends on the domain dynamics and it is affected by the microstructure of material. Therefore the magnetic property is very sensitive to the microstructure change of the material. It is, thus, very useful to detect the state of degradation of varying materials. The test specimen made of 1Cr-1Mo-0.25V steel was used widely for turbine rotor material, and seven kinds of specimens with different degradation levels were prepared by the isothermal heat treatment at $630^{\circ}C$. With the increase of degradation, BHN was decreased. The result was compared with coercive force and vickers hardness.

  • PDF

Evaluation of Noise Power Spectrum Characteristics by Using Magnetic Resonance Imaging 3.0T (3.0T 자기공명영상을 이용한 잡음전력스펙트럼 특성 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.31-37
    • /
    • 2021
  • This study aim of quantitative assessment of Noise Power Spectrum(NPS) and image characteristics of by acquired the optimal image for noise characteristics and quality assurance by using magnetic resonance imaging(MRI). MRI device was (MAGNETOM Vida 3.0T MRI; Siemense healthcare system; Germany) used and the head/neck shim MR receive coil were 20 channels coil and a diameter 200 mm hemisphere phantom. Frequency signal could be acquired the K-space trajectory image and white image for NPS. The T2 image highest quantitatively value for NPS finding of showed the best value of 0.026 based on the T2 frequency of 1.0 mm-1. The NPS acquired of showed that the T1 CE turbo image was 0.077, the T1 CE Conca2 turbo image was 0.056, T1 turbo image was 0.061, and the T1 Conca2 turbo image was 0.066. The assessment of NPS image characteristics of this study were to that could be used efficiently of the MRI and to present the quantitative evaluation methods and image noise characteristics of 3.0T MRI.

Base Acceleration Feedforward Control For An Active Magnetic Bearing System Subject To Base Motion (베이스 가진을 받는 전자기 베어링계의 베이스 가속도 피드포워드 제어)

  • Kang, Min-Sig
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.399.2-399
    • /
    • 2002
  • This paper concerns on a non-rotating single-DOF beam-active magnetic bearing(AMB) system subject to arbitrary shaped base motion. In such a system, it is desirable to retain the beam within the predetermined air-gap under foundation excitation. Motivated form this, an adaptive acceleration feedforward control is proposed to reduce the base motion response without deteriorating other feedback control performances. Experimental results demonstrate the effectiveness of the acceleration feedforward control.

  • PDF