• 제목/요약/키워드: magnetic interference

검색결과 303건 처리시간 0.029초

의료기관 내 전자파 환경 (Electromagnetic Fields in General Hospital)

  • 신세원;윤상모;신현진;안현수;안희덕
    • Journal of Yeungnam Medical Science
    • /
    • 제21권2호
    • /
    • pp.167-176
    • /
    • 2004
  • Background: Electromagnetic fields (EMF) are ubiquitous in modern society including medical field. As the technology of medical instruments and telecommunications has developed rapidly, it has influenced on our lives in many ways. Modern medical practice requires high quality medical equipments, which have a great deal of electromagnetic interference and susceptibility. The purpose of this study were to evaluate electromagnetic condition under usual clinical condition and to suggest a practical guideline in general hospital. Materials and Methods: The actual state of the electromagnetic interference in the medical field was studied under usual clinical conditions including operating rooms, intensive care units, magnetic resonance imaging unit, and hyperthermia unit. Results: There was considerable noise as a result of electromagnetic fields from medical equipments including electrosurgical units and hyperthermia unit, and cellular phones, which could induce serious functional derangements of functioning medical devices. Conclusion: It will be necessary to evaluate the individual electromagnetic situations under various medical conditions and to define a limited zone for cellular phone as well as reposition medical equipments to secure a safer medical practice and to minimize electromagnetic interference.

  • PDF

A Magneto-Optic Waveguide Isolator Using Multimode Interference Effect

  • Yang, J.S.;Roh, J.W.;Lee, W.Y.;Ok, S.H.;Woo, D.H.;Byun, Y.T.;Jhon, Y.M.;Mizumoto T.;Lee,S.
    • Journal of Magnetics
    • /
    • 제10권2호
    • /
    • pp.41-43
    • /
    • 2005
  • We have investigated an optical waveguide isolator with a multimode interference section by wafer direct bonding, operating at a wavelength $1.55\;{\mu}m$. In order to fabricate the device for monolithic integration, the wafer direct bonding between a magnetic garnet material as a cladding layer and a semiconductor guiding layer has been achieved. We found that wafer direct bonding between InP and GGG $(Gd_3Ga_5O_{12})$ is effective for the integration of a waveguide optical isolator. The isolation ratio was obtained to be 2.9 dB in the device.

레이저 간섭 석판술로 전처리된 AAO을 이용한 Fe 나노점 제작 (Fabrication of Fe Nanodot Using AAO Prepatterned by Laser Interference Lithography)

  • 강진혁;황현미;이성구;이재용
    • 한국자기학회지
    • /
    • 제17권3호
    • /
    • pp.137-140
    • /
    • 2007
  • 레이저 간섭 석판 장비(Laser Interference Lithography; LIL)를 이용하여, Anodic Aluminum Oxide(AAO) 나노기공의 배열을 향상 시켰다. 이후 진공에서 Fe와 Cu를 AAO/Si에 성장하고, AAO를 제거하여 Cu/Fe(20 nm) 나노구조를 제작하였다. AAO의 나노기공과 나노구조는 전처리 과정에서 제작된 PR(photoresist) 나노선을 따라 1차원으로 배열되었다. 자성 나노구조의 자기이력곡선으로부터 이들이 vortex 구조를 가지며, 쌍극자 상호작용이 지배적임을 확인하였다.

Evolution Strategy 알고리즘을 이용한 송진선로 주변에서의 최적 자계차폐 위치선정 (Decision of Optimal Magnetic Field Shielding Location around Power System Using Evolution Strategy Algorithm)

  • 최세용;나완수;김동훈;김동수;이준호;박일한;신명철;김병성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권1호
    • /
    • pp.5-14
    • /
    • 2002
  • In this paper, we analyze inductive interference in conductive material around 345 kV power transmission line, and evaluate the effects of mitigation wires. Finite element method (FEM) is used to numerically compute induced eddy currents as well as magnetic fields around powder transmission lines. In the analysis model, geometries and electrical properties of various elements such as power transmission line, buried pipe lines, overhead ground wire, and conducting earth are taken into accounts. The calculation shows that mitigation wire reduces fairly good amount of eddy currents in buried pipe line. To find the optimum magnetic field shielding location of mitigation wire, we applied evolution strategy algorithm, a kind of stochastic approach, to the analysis model. Finally, it was shown that we can find more effective shielding effects with optimum location of one mitigation wire than with arbitrary location of multi-mitigation wires around the buried pipe lines.

하나의 코아로 집적화된 PFC 인덕터와 LLC 공진변압기 적용 AC-DC 컨버터 (AC-DC Converter using the PFC Inductor and LLC Resonant Transformer with an Integrated Magnetic Core)

  • 노영재;강철하;메아스사란;김은수;원종섭;김동희;이영수
    • 전력전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.262-272
    • /
    • 2015
  • An integrated two-in-one transformer applicable to PSUs for a 120 W LED TV is proposed. This transformer comprises a PFC inductor and an LLC transformer placed and integrated on an E-I-E type magnetic core. Performance is evaluated by observing the coupling coefficients of the proposed two-in-one transformer under various air gap topologies. Among the topologies studied, an integrated transformer with centered air gap shows stable operational characteristics with a minimized mutual coupling (interference). Furthermore, applicability of the proposed integrated transformer to PSUs for a 120 W LED TV is studied from the viewpoint of integrating different magnetic components into one core, resulting to low weight, low cost, and high power density.

YBCO SQUID 자력계를 이용한 자기심장검사장치 개발 (Development of magnetocardiograph system using YBCO SQUID magnetometers)

  • 김인선;오수호;임현균;이용호;이순걸;박용기
    • Progress in Superconductivity
    • /
    • 제8권2호
    • /
    • pp.158-163
    • /
    • 2007
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal junctions have been fabricated for magnetocardiograph (MCG) measurements. We could fabricate YBCO SQUID magnetometers having magnetic field noise of about $20fT/Hz^{1/2}$ at white noise region. We have developed an MCG system employing the high performance SQUID magnetometers. The lightweight MCG system, requiring liquid nitrogen as a coolant, consists of 6-channel SQUID sensors, an adjustable patient bed with sliding motion, and data analyses software. The MCG system could record quite clear MCG signals in a room with moderate magnetic shielding. In normal operation with multi-position MCG measurements, we could obtain clear 48-point mappings of magnetic field map and current source map with high enough signal qualities far clinical trials.

  • PDF

Preparation of Chitosan-coated Magnetite Nanoparticles by Sonochemical Method for MRI Contrast Agent

  • Cho, Jun-Hee;Ko, Sang-Gil;Ahn, Yang-Kyu;Choi, Eun-Jung
    • Journal of Magnetics
    • /
    • 제14권3호
    • /
    • pp.124-128
    • /
    • 2009
  • Magnetic nanoparticles were synthesized by using the sonochemical method with oleic acid as a surfactant. The average size of the magnetite nanoparticles was controlled by varying the ratio R=[$H_2O$]/[surfactant] in the range of 2 to 9 nm. To prepare chitosan-coated magnetite nanoparticles, chitosan solution was added to a magnetite colloid suspension under ultrasonication at room temperature for 20 min. The chitosan-coated magnetite nanoparticles were characterized by several techniques. Atomic force microscopy (AFM) was used to image the chitosan-coated nanoparticles. Magnetic hysteresis measurement was performed by using a superconducting quantum interference device (SQUID) magnetometer to investigate the magnetic properties of the magnetite nanoparticles and the chitosan-coated magnetite nanoparticles. The SQUID measurements revealed the superparamagnetism of both nanoparticles. The T1- and T2-weighted MR images of these chitosan-coated magnetite colloidal suspensions were obtained with a 4.7 T magnetic resonance imaging (MRI) system. The chitosancoated magnetite colloidal suspensions exhibited enhanced MRI contrasts in vitro.

MCG 영상진단 검사에 관한 연구 (A Study on MCG Imaging)

  • 김종규
    • 대한임상검사과학회지
    • /
    • 제38권2호
    • /
    • pp.135-140
    • /
    • 2006
  • Magnetocardiography (MCG) is the measurement and analysis of the magnetic component of the electro-magnetic field of the human heart, usually conducted externally, using extremely sensitive devices such as a Superconducting Quantum Interference Device (SQUID). MCG is a totally noninvasive method, it uses neither radiation nor ultrasonics. The magnetic activity of the heart is registered from outside the thorax. MCG has a very high sensitivity and a high spatial resolution for very a small, local myocardial current. In comparison to the electrical signals measured by an ECG, the magnetic signal does not disturb the boundaries of tissues with different electrical properties. MCG measures the myocardial function rather than describing the morphology. MCG is a relatively new technique that promises good spatial resolution and extremely high temporal resolution, thus complementing other heart activity measurement techniques such as Electrocardiography (ECG). The clinical uses of MCG are in detecting various cardiac disorders including myocardial infarction, ventricular hypertrophy, ventricular conduction defects, Wolff-Parkinson-White (WPW) syndrome, sudden cardiac death and fetal magnetocardiography. Magnetocardiography may be used alone or together with electrcardiography for the measurement of spontaneous or overloaded activity and for research or clinical purposes.

  • PDF

줄 인형의 2차원 이동 및 회전을 위한 자석기반 전 방향 로봇시스템 (Omni-directional Mobile Robot for 2D Translation and Rotation of a Puppet using Magnet)

  • 김병열;한영준;한헌수
    • 로봇학회논문지
    • /
    • 제5권4호
    • /
    • pp.326-331
    • /
    • 2010
  • Marionette controlling robot has a problem that generates interference in rotation and intersection, therefore, the research on the independent shifter to move freely on the stage is required. Connecting omni-directional mobile robot with marionette controlling robot can solve this problem. Omni-directional mobile robot makes itself rotate and translate in 2D plane freely. Magnetic device is used to connect the moving part with the control part of the robot to minimize the intereference generated by the movement of robot. When robot moves, it can move to all directions with the suitalbe setting of banlance power. The moment of inertia is minimized by dividing the robot to the upper and lower parts in the marionette performance stage. Rotation and interference problem of independent omni-wheel Robot can be solved by using the permanent magnet. The efficiency and safety of the marionette controlling robot is proved by the experiment.

Double Resonance Perfect Absorption in a Dielectric Nanoparticle Array

  • Hong, Seokhyeon;Lee, Young Jin;Moon, Kihwan;Kwon, Soon-Hong
    • Current Optics and Photonics
    • /
    • 제1권3호
    • /
    • pp.228-232
    • /
    • 2017
  • We propose a reflector-type perfect absorber with double absorption lines using electric and magnetic dipoles of Mie resonances in an array of silicon nanospheres on a silver substrate. In the visible range, hundreds of nanometer-sized nanospheres show strong absorption lines up to 99%, which are enhanced by the interference between Mie scattering and reflections from the silver substrate. The air gap distance between the silicon particles and silver substrate controls this interference, and the absorption wavelengths can be controlled by adjusting the diameter of the silicon particles over the entire range of visible wavelengths. Additionally, our structure has a filling factor of 0.322 when the absorbance is nearly 100%.