• Title/Summary/Keyword: magnetic hysteresis

Search Result 370, Processing Time 0.024 seconds

APPLICATIONS OF ASYMMETRIC HYSTERESIS LOOPS IN AMORPHOUS ALLOYS

  • Jr., C.D. Graham;Shin, K-H.;Zhou, Peter Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.579-582
    • /
    • 1995
  • The use of amorphous magnetic alloys as tags or targets in electronic article surveillance systems such as antishoplifting desvices is briefly reviewed. Improved tags became possible with the discovery in 1988 of asymmetric magnetization reversal (AMR) in certain amorphous alloys annealed in applied field approximately equal to the earth's field. These asymmetric hysteresis loops are highly unusual, if not unique, and so greatly diminish the probability of false alarms in a detection system. furthermore, the jump field Hj, which is the coercive field in negative applied fields, can be controlled over a useful range by controlling the field applied to the sample during annealing. By applying several tags to an object, each with a different jump field, it is possible to identify the object with a numeric code that can be remotely read by nonoptical means.

  • PDF

Effect of SRA on Hysteresis and Eddy Current Components of Iron Loss in Non-Oriented Steels (무방향성 전기 강판 철손의 자기 이력 손실과 와전류 손실에 미치는 SRA의 영향)

  • 송창열;강이국;신용덕
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.208-211
    • /
    • 1995
  • This proper focuses on results of relative permeability(${\mu}$$\sub$r/), core loss(W) and magnetic induction [B] measurements on some of the most commonly used core materials(PN-18, 20, 30, 60, Pohang Iron '||'&'||' Steel Co., Ltd.) In case of Stress Relief Annealing(SRA). Results of magnetic induction[B] showed weak variations but core lass reduced strongly after SRA Core loss reduced from 3.071 ∼7.819(W/kg) and 11.377~3.988[W/kg] to 2.88~5.492[W/kg] and 1.213~2.134[W/kg] at 1.5[T] 50 Hz and 1.0 [T] 50Hz respectively after SRA. This SRA process leads to significant changes In magnetic properties and core loss of non-oriented silicon steel sheet.

  • PDF

Reduction of Cogging Torque of BLDC Motors by Realizing Sinusoidal Air-Gap Flux Density Distribution (BLDC 전동기의 정현파 공극 자속밀도 구현에 의한 코깅토오크 저감)

  • Kim, Samuel;Jeong, Seung-Ho;Kwon, Byung-Il;Lee, Chul-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.140-142
    • /
    • 2006
  • Cogging torque is often a principal source of vibration, noise and difficulty of control in permanent-magnet brushless DC motors. Cogging torque can be minimized by sinusoidal air-gap flux density waveform because it is produced by the interaction of the rotor magnetic flux and angular variation in the stator magnetic reluctance. Therefore, this paper will present a design method of magnetization system of bonded isotropic neodynium-iron-boron(Nd-Fe-B) magnets in ring type with sinusoidal air-gap flux density distribution and low manufacturing cost. An analytical technique of magnetization makes use of two-dimensional finite element method(2D FEM) and Preisach model that expresses the hysteresis phenomenon of magnetic materials in order for accurate calculation.

  • PDF

Comparison of Different Techniques for Measurement of Cold Work in Mild Steel

  • Badgujar, B.P.;Jha, S.K.;Goswami, G.L.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.6
    • /
    • pp.616-621
    • /
    • 2003
  • There are various Non-Destructive Evaluation (NDE) techniques used for measurement of residual stresses in material, such as magnetic methods, X-ray diffraction, Ultrasonic velocity measurement etc. The capabilities, applications and limitations of these techniques for evaluation of cold work/plastic deformation were studied and compared. Mild steel plates were subjected to different degree of cold deformation and were analyzed by Magneto-mechanical Acoustic Emission (MAE), Barkhausen Noise (BN) and magnetic properties (hysteresis loop parameters analysis). Further, these specimens were analyzed by X-ray diffraction and ultrasonic velocity measurements. The microhardness measurement and microstructure studies of these cold worked plates were also carried out. The results of all these studies and comparison of different techniques are discussed in this paper.

Simulation and analysis of the magnetic inrush for the 765kV transformer using EMTP-RV (EMTP-RV를 이용한 765kV 변압기의 여자 돌입 현상 모의 및 분석)

  • Kang, Yong-Cheol;Lee, Mi-Sun;Lee, Byung-Eun;Jang, Sung-Il;Kim, Yong-Gyun;Ju, Haeng-Ro;Yu, Yeong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.157-159
    • /
    • 2008
  • This paper describes modeling and analysis of magnetic inrush for a 765kV transformer using EMTP-RV. EMTP-RV generates the core flux and thus helps show the behavior of the core, i.e. hysteresis characteristics. The results of three kinds of the magnetic inrush such as initial inrush, sympathetic inrush, and recovery inrush are included. This modelling can help the design of a protection relay for a transformer.

  • PDF

Development of an Inductive Position Sensor Using Magnetic Bearing Technology (자기 베어링 기술을 이용한 유도형 변위센서 개발)

  • 노명규;박병철;노승국;경진호;박종권
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.4
    • /
    • pp.72-78
    • /
    • 2004
  • In this paper, a development of an inductive position sensor is described. The sensor is similar to a radial magnetic bearing in that the sensor stator is shaped like a heteropolar magnetic bearing and is driven by a switching amplifier. A demodulation filter extracts the gap information from the switching current ripples. A prototype sensor exhibits the resolution of $0.43\mum$ and the dynamic bandwidth of about 800Hz. The dynamic performance can be improved by increasing the switching frequency. However, the eddy current effects become noticeable at high switching frequency, thus limiting the improvement of the bandwidth.

Finite Element Analysis of Magnetostrictive Linear Actuator (자왜재료를 이용한 선형 작동기의 유한요소 해석)

  • Kim, Yoon-Chang;Kim, Jae-Hwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.4 s.121
    • /
    • pp.356-362
    • /
    • 2007
  • Magnetostrictive materials have been used for linear actuators due to its large strain, large force output with moderate frequency band in the presence of magnetic field. However their performance analysis is difficult because of nonlinear material behaviors in terms of coupled strain-magnetic field dependence, nonlinear permeability, pre-stress dependence and hysteresis. This paper presents a finite element analysis technique for magnetostrictive linear actuator. To deal with coupled problems and nonlinear behaviors, a simple finite element approach is proposed, which is based on separate magnetic field calculation and displacement simulation. The finite element formulation and an in-house program development are illustrated, and a simulation model is made for a magnetostrictive linear actuator. The fabrication and performance test of the linear actuator are explained, and the performance comparison with simulation result is shown. Since this approach is simple, it can be applied for analyzing magnetostrictive underwater projectors and ultrasonic transducers.

Detection of Magnetic Nanoparticles and Fe-hemoglobin inside Red Blood Cells by Using a Highly Sensitive Spin Valve Device

  • Park, Sang-Hyun;Soh, Kwang-Sup;Hwang, Do-Guwn;Rhee, Jang-Roh;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.13 no.1
    • /
    • pp.30-33
    • /
    • 2008
  • A highly sensitive, giant magnetoresistance-spin valve (GMR-SV) biosensing device with high linearity and very low hysteresis was fabricated by photolithography. The detection of magnetic nanoparticles and Fe-hemoglobin inside red blood cells using the GMR-SV biosensing device was investigated. When a sensing current of 1 mA was applied to the current electrode in the patterned active devices with an area of $2{\times}6{\mu}m^2$, the output signals were about 13.35 mV. The signal from even one drop of human blood and nanoparticles in distilled water was sufficient for their detection and analysis.

Magnetization Loss Characteristics of a Bi-2223 Tape in Parallel Magnetic Fields (수평자장에 대한 Bi-2223테이프의 자화손실 특성)

  • Ryu, Kyung-Woo;Han, Hyung-Ju;Choi, Byung-Ju;Nah, Wan-Soo;Joo, Jin-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.4
    • /
    • pp.158-163
    • /
    • 2001
  • Magnetization losses of a Bi-2223 tape in magnetic fields parallel to the tape surface were measured by a room temperature cancellation and a cryogenic temperature cancellation. The results indicate that the same loss data are observed for both methods. The magnetization losses are hysteretic because the measured losses agree well with calculated ones based on a critical state model. In the full field penetration cases the magnetization losses increase with the frequency but in the partial field penetration cases the influence of the frequency is opposite.

  • PDF

Degradation of 0.2PMN-0.8PZT Multilayer Ceramic Actuators

  • Song, Jae-Sung;Koh, Jung-Hyuk;Jeong, Soon-Jong;Wee, Sang-Bong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.1
    • /
    • pp.6-9
    • /
    • 2005
  • Aging characteristics of 0.2PMN-0.8PZT multilayer ceramic actuators (MCA) has been investigated by applying both triangular wave function for unpoled and unipolar wave for poling. P-E hysteresis loops of the MCA had been distorted after about 90 million cycles running in triangular wave function. Effective electromechanical coupling coefficient was calculated in resonant and anti resonant frequencies. And pseudo-piezoelectric constant $d_{33}$ was also estimated from the strain versus electric field characteristics. The crack growth of MCA was clearly observed along to the boundary between electrode and inactive area. That results were thought due to the internal tensile stress came from both actuation of $d_{33}$ mode and motion of Poisson ratio.