• Title/Summary/Keyword: magnetic filed

Search Result 75, Processing Time 0.024 seconds

Arc behaviors and electrode surface damage under the axial magnetic field (축 방향 자기장애 의한 아크의 거동과 전극표면의 손상)

  • Cho, Chu-Hyun;Choi, Young-Wook;Han, Yong-Ki;Han, Hyun;Kwon, Oh-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.188-189
    • /
    • 2007
  • Axial magnetic field was applied into the hollow anode of plasma torch for the purpose of extension of electrode lifetime. The average arc voltage increased because the arc column became longer, the arc voltage ripple frequency became low. The steady state of arc voltage was removed by applied magnetic filed. The lifetime of electrode was over 1000 hours which is 100 times longer than operation without magnetic field.

  • PDF

Generation of n Precision Magnetic Filed Using Electromagnet and NMR Magnetometer (전자석과 핵자기공명 자장측정기를 이용한 정밀자장의 발생)

  • Kim, Young-Gyun;Park, Po-Gyu;Park, Jeong-Kwon
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.4
    • /
    • pp.137-142
    • /
    • 2002
  • A precision magnetic field was generated by the NMR magnetometer and electromagnet system. The current and field feedback systems are used to control of magnetic field in the electromagnet using computer. Stability of magnetic field according to results that compare field and current feedback, current method is better than 2 times. The stability of magnetic field with current feedback improved 10 times compared with no feedback. This system is used for the calibration of magnetometers and the testing related to magnetic fields.

Non-contact critical current measurement using hall probe (Hall probe를 이용한 비접촉 임계전류 측정)

  • Kim, Ho-Sup;Lee, Nam-Jin;Ha, Dong-Woo;Baik, Seung-Kyu;Kim, Tae-Hyung;Ko, Rock-Kil;Ha, Hong-Soo;Oh, Sang-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.7-8
    • /
    • 2009
  • Non-contact critical current measurement apparatus was developed using hall probe which measures the magnetic field distribution across the width of superconducting tape. The hall probe consists of 7 independent hall sensors which lie in a line 600 ${\mu}m$. The difference between maximum and minimum magnetic field in the magnetic filed distribution is a main parameter to determine the critical current. As preliminary research, we calculated the magnetic field intensity at the middle sensor, which is a minimum magnetic field and generated by the circular shielding current modeled by Bean model. We confirmed that there are some parameters that affect on the minimum magnetic field; the distance between superconducting layer and hall sensor, the width of superconducting tape, and the critical current distribution across the width of superconducting tape. Among these parameters, the distance between superconducting layer and hall sensor highly influences on the minimum magnetic field.

  • PDF

Effects of the External Magnetic field on the Critical Current and AC Loss of HTS Stacked Tapes

  • Lee, Seungwook;Hyoungwoo Lim;Park, Myeongseob;Lee, Heejoon;Gueesoo Cha;Lee, Jikwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.87-91
    • /
    • 2003
  • According to the improvement of the HTS wires performance, several types of HTS superconducting machines are being developed. Stacked HTS tapes are used to conduct the current of the HTS power machines. To develop the HTS power machines, the critical current characteristics of a stacked HTS tapes in external field need be examined. In this paper, we present effect of the external magnetic field on the critical current of HTS stacked tapes. The critical current of various Hinds of multi-stacked HTS tapes in external magnetic filed are compare with that of a single HTS tape. Test results show that critical current of single HTS tape is smaller than that of multi-stacked HTS tape in the external field.

An Analysis on Core Loss Characteristics for Linear Oscillatory Motor with Permanent Magnet Mover (영구자석 가동자를 갖는 직선형 왕복운동 전동기의 철손 특성 해석)

  • Jang, Seok-Myeong;Kim, Kwan-Ho;Choi, Jang-Young;Cho, Han-Wook;Jeong, Sang-Sub;Seo, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1023-1024
    • /
    • 2011
  • This paper deals with an improved core loss calculation of Linear Oscillatory Motor from curve fitting method using modified Steinmetz equation considered anomalous loss. For an accurate calculation, magnetic field analyses in stator core considering, magnetic field analyses in stator core considering the time harmonics are performed. And using the nonlinear finite element analysis (FEM), we applied separated rotating and alternating magnetic filed to core loss calculation.

  • PDF

Setup and Operating Characteristics of the Experimental Apparatus for Magnetization Measurements of Sperconductor (초전도체 자화특성 측정을 위한 실험장치의 구축 및 그 동작 특성)

  • 최세용;나완수;주진호
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.30-36
    • /
    • 1999
  • Superconductors are dissipative when exposed to time-varying magnetic fields. To analyze the AC characteristics of a superconductor, one usually needs to know magnetization curves of it. Good magnetization curves can be obtained only in homogeneous magnetic filed. In This paper, we report the setup and test results of a magnetization measurement system, which consists mainly of frequency-variable power supply and homeogenous magnet with 7-cm long air gap. Special emphasis are foused on the design and fabrication of the magnet, which aims to give background magnetic fields, and on the overall characteristics of the system.

  • PDF

Srability Analysis Of High-Tc Superconducting Tape Through Magnetic Field Analysis Of The High-Tc Superconducting synchronous Motor (고온초전도동기모터의 자계분포해석에 따른 테이프선재의 안정도해석)

  • 송명곤;윤용수;홍계원;이산진;고태국
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.25-29
    • /
    • 1999
  • The purpose of this paper is to find the magnetic filed distribution inside the motor in order to find out if the high-Tc superconducting tapes operate stably in actual motor operation in a detailed model of the actual motor was analyzed through F.E.M.(finite Element Method). As a result, it has been proved that the high-Tc superconducting tapes can with-stand 4 A of current with staility. 4 A was the amount of current with stability. 4 A was the amount of current needed to achieve 600 A·turns which is required by the previous simulation aimed at developing this the flux damper reduces armature reactance during the motor operation. But it was observed that the flux damper generates loss by means of leakage flux and this decreases the output of the motor by about 5%.

  • PDF

Dynamic Properties of Squeeze Type Mount Using MR Fluid (MR유체를 이용한 스퀴즈모드형 마운트의 동특성)

  • 하종용;안영공;양보석;정석권;김동조
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.374-378
    • /
    • 2003
  • This paper presents investigation of damping characteristics of squeeze mode type MR (Magneto-Rheological) mount experimentally. Since damping property of the MR fluid is changed by variation of the applied magnetic field strength, squeeze mode type MR mount proposed in the study has variable damping characteristics according to the applied magnetic field s strength. In the present work, the performance of the mount was experimentally investigated according to the magnetic field strength and exciting frequencies. The experimental results present that the MR mount can effectively reduce the vibration in a wide range of frequency by controlling the applied electromagnetic filed strength. Viscous damping and stiffness coefficients of the MR mount tend to be changed according to the variation of the applied currents in this study and MR effect is reduced by increasing exciting frequency.

  • PDF

Travelling Magnetic Field Problem Analyses by Finite Element Method (운동자계문제의 해석을 위한 유한요소법에 관한 연구)

  • Han, Pil-Wan;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.76-78
    • /
    • 1999
  • This paper presents Galerkin- and Upwind-finite element analyses solution in the travelling magnetic filed problem. The travelling magnetic field problem is subject to convective- diffusion equation. Therefore, the solution derived from Galerkin-FEM with linear interpolation function may oscillate between the adjacent nodes. A simple model with Derichlet, Noumann and periodic boundary condition respectively, have been analyzed to investigate stabilities of solutions. It is concluded that the solution of Galerkin-FEM may oscillate according to boundary condition and element type, but that of Upwind-FEM is stable regardless boundary condition.

  • PDF