• Title/Summary/Keyword: magnetic diagnostic

Search Result 714, Processing Time 0.024 seconds

Magnetic Resonance Imaging Meets Fiber Optics: a Brief Investigation of Multimodal Studies on Fiber Optics-Based Diagnostic / Therapeutic Techniques and Magnetic Resonance Imaging

  • Choi, Jong-ryul;Oh, Sung Suk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.218-228
    • /
    • 2021
  • Due to their high degree of freedom to transfer and acquire light, fiber optics can be used in the presence of strong magnetic fields. Hence, optical sensing and imaging based on fiber optics can be integrated with magnetic resonance imaging (MRI) diagnostic systems to acquire valuable information on biological tissues and organs based on a magnetic field. In this article, we explored the combination of MRI and optical sensing/imaging techniques by classifying them into the following topics: 1) functional near-infrared spectroscopy with functional MRI for brain studies and brain disease diagnoses, 2) integration of fiber-optic molecular imaging and optogenetic stimulation with MRI, and 3) optical therapeutic applications with an MRI guidance system. Through these investigations, we believe that a combination of MRI and optical sensing/imaging techniques can be employed as both research methods for multidisciplinary studies and clinical diagnostic/therapeutic devices.

The Optimization of Scan Timing for Contrast-Enhanced Magnetic Resonance Angiography

  • Jongmin J. Lee;Phillip J. Tirman;Yongmin Chang;Hun-Kyu Ryeom;Sang-Kwon Lee;Yong-Sun Kim;Duk-Sik Kang
    • Korean Journal of Radiology
    • /
    • v.1 no.3
    • /
    • pp.142-151
    • /
    • 2000
  • Objective: To determine the optimal scan timing for contrast-enhanced magnetic resonance angiography and to evaluate a new timing method based on the arteriovenous circulation time. Materials and Methods: Eighty-nine contrast-enhanced magnetic resonance angiographic examinations were performed mainly in the extremities. A 1.5T scanner with a 3-D turbo-FLASH sequence was used, and during each study, two consecutive arterial phases and one venous phase were acquired. Scan delay time was calculated from the time-intensity curve by the traditional (n = 48) and/or the new (n = 41) method. This latter was based on arteriovenous circulation time rather than peak arterial enhancement time, as used in the traditional method. The numbers of first-phase images showing a properly enhanced arterial phase were compared between the two methods. Results: Mean scan delay time was 5.4 sec longer with the new method than with the traditional. Properly enhanced first-phase images were found in 65% of cases (31/48) using the traditional timing method, and 95% (39/41) using the new method. When cases in which there was mismatch between the target vessel and the time-intensity curve acquisition site are excluded, erroneous acquisition occurred in seven cases with the traditional method, but in none with the new method. Conclusion: The calculation of scan delay time on the basis of arteriovenous circulation time provides better timing for arterial phase acquisition than the traditional method.

  • PDF

Accelerating Magnetic Resonance Fingerprinting Using Hybrid Deep Learning and Iterative Reconstruction

  • Cao, Peng;Cui, Di;Ming, Yanzhen;Vardhanabhuti, Varut;Lee, Elaine;Hui, Edward
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.293-299
    • /
    • 2021
  • Purpose: To accelerate magnetic resonance fingerprinting (MRF) by developing a flexible deep learning reconstruction method. Materials and Methods: Synthetic data were used to train a deep learning model. The trained model was then applied to MRF for different organs and diseases. Iterative reconstruction was performed outside the deep learning model, allowing a changeable encoding matrix, i.e., with flexibility of choice for image resolution, radiofrequency coil, k-space trajectory, and undersampling mask. In vivo experiments were performed on normal brain and prostate cancer volunteers to demonstrate the model performance and generalizability. Results: In 400-dynamics brain MRF, direct nonuniform Fourier transform caused a slight increase of random fluctuations on the T2 map. These fluctuations were reduced with the proposed method. In prostate MRF, the proposed method suppressed fluctuations on both T1 and T2 maps. Conclusion: The deep learning and iterative MRF reconstruction method described in this study was flexible with different acquisition settings such as radiofrequency coils. It is generalizable for different in vivo applications.

A Study on Utility of Magnetic Resonance Imaging for Female Pelvic Cavity using Enteral MRI Contrast Media (Enteral MRI contrast media를 이용한 여성골반 자기공명영상의 유용성)

  • Kim, Ham-Gyum
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.29-34
    • /
    • 1997
  • For radiological test in soft tissue or neighboring part with same signal intensity, proper test method and equipment shall be selected as needed. In case of female pelvic cavity, ultrasonography or computed tomography alternatively used, but MRI can be more usefully applied to design treatment method or operation plan by improving the diagnostic accuracy and careful observation of lesion characteristics. Magnetic Resonance Imaging using recently developed Enteral MRI contrast media can acquire more diagnostic information than using only intravenous contrast media. Thus this study attempted to examine the utility of anatomic structure and diagnostic acquisition by imaging the female pelvic cavity using Enteral MRI contrast media. As a result of analyzing magnetic resonance Imaging after administering Enteral MRI contrast media to pelvic cavity suspect patients, more diagnostic information media could be acquired than only using Intravenous contrast. Expecially, in the diagnosis of lesion position, shape, distinction from neighboring tissues it is thought that external Enteral MRI contrast media should be used.

  • PDF

Magnetic Resonance Imaging of Placenta Accreta Spectrum: A Step-by-Step Approach

  • Sitthipong Srisajjakul;Patcharin Prapaisilp;Sirikan Bangchokdee
    • Korean Journal of Radiology
    • /
    • v.22 no.2
    • /
    • pp.198-212
    • /
    • 2021
  • Placenta accreta spectrum (PAS) is an abnormal placental adherence or invasion of the myometrium or extrauterine structures. As PAS is primarily staged and managed surgically, imaging can only guide and facilitate diagnosis. But, imaging can aid in preparations for surgical complexity in some cases of PAS. Ultrasound remains the imaging modality of choice; however, magnetic resonance imaging (MRI) is required for evaluation of areas difficult to visualize on ultrasound, and the assessment of the extent of placenta accreta. Numerous MRI features of PAS have been described, including dark intraplacental bands, placental bulge, and placental heterogeneity. Failure to diagnose PAS carries a risk of massive hemorrhage and surgical complications. This article describes a comprehensive, step-by-step approach to diagnostic imaging and its potential pitfalls.

Embodiment of Spatially Arterial Pulse Diagnostic Apparatus using Array Multiple Hall Devices

  • Lee, Sang-Suk;Kim, Gi-Wang;Ahn, Myung-Cheon;Park, Young-Seok;Choi, Jong-Gu;Choi, Sang-Dae;Park, Dal-Ho;Hwang, Do-Guwn;Yoon, Hyung-Rho
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.721-726
    • /
    • 2007
  • The study relates to achievement and analysis of 3-dimensional spatial pulse wave archived by a spatially arterial pulse diagnostic apparatus (SAPDA), wherein a pulse sensing part array consists of multiple hall devices and is located over a skin contacting part which consists of a magnetic material. When a radially arterial pulse is transferred to the magnetic material, which is contacted skin that results in changes in a magnetic field of the lower part of the pulse sensing part array, the changes in a magnetic field can be detected by the commercial Hall semiconductor device of the pulse sensing part array. Finally, according to development of SAPDA, the 3-dimensionally arterial pulse waveform can be measured noninvasively by detecting the changes of the magnetic field.