• 제목/요약/키워드: magnetic curve

검색결과 442건 처리시간 0.026초

편광-자기장 눈금조정 곡선 (POLARIZATION-MAGNETIC FIELD CALIBRATION CURVE)

  • 김갑성
    • 천문학논총
    • /
    • 제12권1호
    • /
    • pp.1-21
    • /
    • 1997
  • We have obtained theoretical calibration curves to convert the amount of polarization into the strength of magnetic field, by a numerical calculation of radiation transfer for the polarized spectral line of FeI $6303{\AA}$. In our calculation, three kinds of atmospheric models (VAL-C, penumbra, umbra) have been used to make a proper calibration for an active region composed of quiet, penumbral and umbral areas. It was found that firstly, the results of our calculation depend highly on a kind of atmospheric model rather than on any other input parameters used in a model. Secondly, observed line profile showed m solar spectrum atlas proved to be very similar to the calculated profiles obtained by using a penumbra model. Finally, another method except this calibration curve should be developed to estimate correctly the distribution of magnetic field in solar active region from the observation of polarized spectral line.

  • PDF

동기릴럭턴스전동기의 자기포화를 고려한 최대토크제어 (A Maximum Torque Control of Synchronous Reluctance Motors Considering Magnetic Saturation)

  • 신명호
    • 조명전기설비학회논문지
    • /
    • 제28권10호
    • /
    • pp.89-94
    • /
    • 2014
  • This paper presents a synchronous reluctance motor drive for maximum torque to current (MTC) considering magnetic saturation. Measured d-axis and q-axis inductances are used to obtain current angle vs. maximum torque curve using torque equation. Maximum torque to current control is achieved by the current angle and stator current for maximum torque from the current angle vs. maximum torque curve at a given torque reference.

철심의 자화곡선을 이용한 자기차폐형 고온초전도 전류제한기 특성 (Characteristic of Magnetic Shielding Type High-Tc Superconducting Fault Current Limiter Using Magnetization Curve of Iron Core)

  • 이재;임성훈;송재주;김준혁;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.511-514
    • /
    • 2002
  • In this paper, we compared the characteristic of fault current liminting in the magnetic shielding type High-Tc superconducting fault current limiter(FCL) using both Piecewise linear magnetization curve and real magnetization one of iron core. From this paper, the characteristics of fault current limiting in both cases showed many differences. The latter has higher fault current than the former, because the saturation of iron core was reflected and more accumulated during fault. It is expected that the more exact characteristic of magnetic shielding type High-Tc superconducting FCL was obtained in the case of design and modeling.

  • PDF

자기 베어링 시스템의 모델링 및 동정에 관한 연구 (A Study on Modeling and Identification for the Magnetic Bearing System)

  • 심성효;김창화;양주호
    • 동력기계공학회지
    • /
    • 제5권4호
    • /
    • pp.44-52
    • /
    • 2001
  • This paper considers a modeling and identification for the MIMO magnetic bearing system. To obtain the nominal plant transfer functions, we have experimented on the frequency response by a closed-loop identification method because the system is unstable essentially. We suggest a method of curve-fitting for obtaining the transfer function from the frequency responses by using the system's modeling structure and two controllers which are different from each other. From the frequency response results, we found the effects of coupling by opposing controllers. And using this effects and the system's modeling structure, we could obtain the transfer functions of which have the same modularized denominators.

  • PDF

Study of the Hopkinson Effect in the HDDR-treated Nd-Fe-B-type Material

  • Kwon, H.W;Shon, S.W
    • Journal of Magnetics
    • /
    • 제6권2호
    • /
    • pp.61-65
    • /
    • 2001
  • The Hopkinson effect in the HDDR-treated $Nd_{15}Fe_{77}B_8$ allay was examined in detail by means of a thermo-magnetic analysis with low magnetic field (600 Oe). The emergence and magnitude of maximum in magnetisation in the thermomagnetic curve due to the Hopkinson effect was correlated with the grain structure and coercivity of the HDDR-treated material. The HDDR-treated materials showed a clear Hopkinson effect (maximum in magnetisation just below the Curie temperature of the $Nd_2Fe_{14}B\;$ phase) on heating. The magnitude of the magnetisation rise due to the Hopkinson effect became smaller as the recombination time increased. The magnetisation recovery at room temperature on cooling from above the Curie temperature became smaller as the recombination time increased. The HDDR-treated materials with shorter recombination time, finer grain size and higher coercivity showed larger magnetisation maximum due to the Hopkinson effect in the thermo-magnetic curve.

  • PDF

자화이력 해석을 위한 hysteresis 모델에 관한 연구 (Study of hysteresis model for magnetic hysteresis analysis)

  • 이정종;송백기;홍정표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.871_872
    • /
    • 2009
  • This paper presents study of hysteresis model for magnetic hysteresis analysis by Preisach model. In ferromagnetic material, magnetization is non-linear and varies according to magnetic field which is called B-H curve. As hysteresis phenomenon affect on performance of motor, magnetic hysteresis analysis is essential and needed for designing motor that satisfies specification. Therefore, in this paper, methods for calculating magnetization are presented and discussed.

  • PDF

BPSCCO 초전도체의 전기 자기적 효과 (Electromagnetic Effects of BPSCCO Superconductor)

  • 이상헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.112-114
    • /
    • 2001
  • The magnetic suspension of a high T$\sub$c/ BipbSrCaCuO superconductor beneath toroial Permanent magnet was examined by means of an improved magneto-balancing method at 77K. Both the experimental values of the suspending position and the force exerted upon the superconducting specimen were in good agreement with those calculated from the magnetization curve of the specimen and the magnetic field map of the used permanent magnet.

  • PDF

Determination of the Size Distribution of Magnetite Nanoparticles from Magnetic Measurements

  • Yoon, Sung-Hyun
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.368-373
    • /
    • 2011
  • Particle size distributions in 10 nm magnetite ferrofluids are analyzed based on both dc and ac magnetic measurements. Modified log-normal distributions are used for fitting the experimental results, which allows for a proper account of the narrow distributions. The calculated average particle sizes are in good agreement with the TEM results. However the ac method gives a much narrower distribution width than that of the dc magnetization curve fit. The proposed measurements combined with the analysis methods are useful for the characterization of ferrofluids being considered for biomedical applications.

MAGNETIC CURVES IN ℍ3 × ℝ

  • Erjavec, Zlatko;Inoguchi, Jun-ichi
    • 대한수학회지
    • /
    • 제58권6호
    • /
    • pp.1501-1511
    • /
    • 2021
  • In this paper we study magnetic trajectories on ℍ3 × ℝ with respect to the strictly almost Kähler structure. We find three types of magnetic curves which correspond to the almost complex structure compatible to the product metric on ℍ3 × ℝ.

Development of Micro-size Search Coil Magnetometer for Magnetic Field Distribution Measurement

  • Ka, E.M.;Son, De-Rac
    • Journal of Magnetics
    • /
    • 제13권1호
    • /
    • pp.34-36
    • /
    • 2008
  • For the measurement of the magnetic field distribution with high spatial resolution and high accuracy, the magnetic field sensing probe must be non-magnetic, but the MFM probe and sub-millimeter-meter size Hall probe use a ferromagnetic tip and block, respectively, to increase the sensitivity. To overcome this drawback, we developed a micro-size search coil magnetometer which consists of a single turn search coil, Terfenol-D actuator, scanning system, and control software. To reduce the noise generated by the stray ac magnetic field of the actuator driving coil, we employed an even function $\lambda$-H magnetostriction curve and lock-in technique. Using the developed magnetometer, we were able to measure the magnetic field distribution with a magnetic field resolution of 1 mT and spatial resolution of $0.1mm{\times}0.2mm$ at a coil vibration frequency of 1.8 kHz.