• Title/Summary/Keyword: machined

Search Result 1,237, Processing Time 0.028 seconds

Translucency and Color Stability of Various Core Ceramics for All-Ceramic Restoration (전부도재수복물을 위한 수종의 코어 세라믹의 반투명도 및 색 안정성)

  • Oh, Sang-Chun;Lee, Hae-Hyoung;Shin, Mee-Ran;Park, Kwang-Su
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.2
    • /
    • pp.157-170
    • /
    • 2007
  • Purpose: This investigation was designed to determine the translucency and color stability of various core ceramics for all-ceramic restoration using the CIE $L^*a^*b^*$ system. Material and Methods: IPS e.max Press ceramic(Ivoclar-Vivadent, Liechtenstein), $LAVA^{TM}$ All Ceramic(3M-Espe, Germany), Cercon Smart Ceramic(Dentsply, Germany), and Z-match Ceramic(DentAim, Korea) were used for this study. For the specimens of zirconia oxide ceramics, the as-sintered cylindrical blanks($11.0{\times}25.0mm$) were machined into the shape of a disk(0.4, 0.8, 1.5 mm in thickness, 10 mm in diameters) with a diamond grind machine. The IPS e.max Press specimens ($0.8{\times}10mm$) were fabricated using the "lost wax" technique. CIE $L^*a^*b^*$ coordinates and light transmission were recorded for each specimen with a spectrophotometer(CM-2600d, Minolta, Japan). Color differences were calculated using the equation, ${\Delta}E^*ab=[({\Delta}L^*)2+({\Delta}a^*)2+({\Delta}b^*)2]1/2$. Results: The results were obtained as follows: 1. The most translucent group was IPS e.max Press ceramic that is a glass-ceramic, and $Lava^{TM}$ and Z-match ceramic were more translucent than Cercon Smart ceramic in zirconia ceramic group. 2. In the all groups, there was no significant translucent change after 6 times heat-treatments required to make a final restoration. 3. Colored zirconia was showed more yellowish and dark than uncolored zirconia. 4. After heat-pressing, IPS e.max Press ceramic was showed high ${\Delta}E^*ab$ value(4.1 of eM1, 6.8 of eM2) that means to be more whiter than before heat-pressing. However, there was no color change after additive heat treatments for final restoration. 5. In the colored zirconia groups, there was no significant color change after some heat-treatments required to make a final restoration.

Effects of electrical stimulation on healing of endo-osseous titanium implants in circumferential defect (전기자극이 성견 골결손부에 매식된 임플란트 주위조직의 치유에 미치는 영향)

  • Shim, Jae-Chang;Kim, Young-Jun;Chung, Hyun-Ju;Kim, Ok-Su
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.177-193
    • /
    • 2004
  • Several experimental studies showed that the application of small amounts of electric current to bone stimulated osteogenesis at the site of the cathode and suggested that electrical currents promote osseointegration around dental implants. The purpose of this study was to determine the effect of direct microcurrent to endosseous titanium implants placed in bone defects. The right and left 2nd, 3rd and 4th mandibular premolars in ten mongrel dogs (15Kg of weight) were extracted. One monthe later, Ti-machined screw type implants(3.8 mm diameter x 8.5 mm length, $AVANA^{(R)}$, Ostem) were placed in surgically created circumferential defect area(width 5mm, depth 4mm). The implants were divided into three groups according to the treatment modalities: Control group- implants without electrical stimulation; Experimental group I- implants with allogenic demineralized freeze dried bone grafting; and Experimental group II-implants allogenic demineralized freeze dried bone grafting and electric stimulation. The animals were sacrificed in the 4th and 8th week after implant placement and un-decalcified specimens were prepared for histological and histometrical evaluation of bone-implant contact ratio (BIC) and bone formation area ratio (BFA) in defect area. Some specimens at 8 weeks after implantation were used for removal torque testing. Histologically, there was connective tissue infiltration in the coronal part of defect area in control and the experimental group I, whereas direct bone contact was found in the experimental group II without connective tissue invasion. Average BIC ratios at 4 weeks of healing were 60.1% in the experimental group II, 47.4% in the experimental group I and 42.7% in the control. Average BIC ratios at 8 weeks after implantation were 67.6% in the experimental group II, 55.9% in the experimental group I and 54.6% in the control. The average BFA ratio was 84.0% in the experimental group II, 71.8% in the experimental group I and 58.8% in the control at 4 weeks, and the BFA ratios were 89.6% in the experimental group II, 81.4% in the experimental group I and 70.5% in the control at 8 weeks after implantation. The experimental group II showed also significantly greater BIC and BFA ratios compared to the control and the experimental group I (p<0.05). The removal torque values at 8 weeks after implantation were 56 Ncm in the experimental group II, 49 Ncm in the experimental group I and 43 Ncm in the control. There was a statistically significant difference among 3 groups (p<0.05). These results suggest that electrical stimulation improve and accelerate bone healing around endosseous titanium implants in bone defect.

The Characteristics of Acoustic Emission Signal under Composite Destruction on GFRP Gas Cylinder (유리섬유강화 복합재료 가스실린더의 복합재료 파괴시 발생하는 음향방출 특성)

  • Jee, Hyun-Sup;Lee, Jong-O;Ju, No-Hoe;So, Cheal Ho;Lee, Jong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.430-435
    • /
    • 2013
  • This study is investigation of the characteristics for acoustic emission signal generated by destruction on glass fiber bundles and specimen that was machined composite materials surrounding the outside of GFRP cylinder. The Amplitude of acoustic emission signal gets bigger as the cutting angle of knife increases. Accordingly, the number of hits in destruction of composite materials specimen have more in longitudinal direction (longitudinal direction to the glass fiber) than in hoop direction (horizontal direction to the glass fiber) while the amplitude of signals were bigger in hoop direction than longitudinal direction. It was found out that the amplitude of the glass fiber breakage is more than 40 dB and that the amplitude of signal for matrix crack was less than 40 dB because matrix crack signal was not observed when threshold value is 40 dB and matrix crack signal suddenly appered when threshold value is 32 dB. The slope of the amplitude is related to the acoustic emission source and the slope of the amplitude of the horizontal and vertical directions are 0.16 and 0.08. In particular, The slope of the amplitude of longitudinal direction breakage appear similar to the glass fiber breakage and therefore Acoustic emission source of longitudinal direction breakage is estimated the glass fiber breakage.

Finite Element Simulation of Laser-Generated Ultrasound and Interaction with Surface Breaking Cracks (유한요소법을 이용한 레이저 유도 초음파와 표면 균열과의 상호작용 모델링)

  • Jeong, Hyun-Jo;Park, Moon-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • A finite element method is used to simulate interaction of laser-based ultrasounds with surface breaking tracks in elastic media. The laser line source focused on the surface of semi-infinite medium is modeled as a shear dipole in 2-D plane strain finite elements. The shear dipole-finite clement model is found to give correct directivity patterns for generated longitudinal and shear waves. The interaction of surface waves with surface breaking cracks (2-D machined slot) is considered in two ways. Both the source and receiver are fixed with respect to the cracks in the first case, while the source is moving in another case. It is shown that the crack depth tested in the range of 0.3-5.0mm $({\lambda}_R/d=0.21{\sim}3.45)$ can be measured using the corner reflected waves produced by the fixed laser source. The moving laser source is found to cause a large amplitude change of reflected waves near crack, and the crack whose depth is one order lower than the wavelength ran be detected from this change.

The Modelling and Machining of Leisure Boat Plug using CAD/CAM System (CAD/CAM 시스템을 이용한 레저보트의 플러그 모델링 및 가공)

  • Kim, Seong-Il
    • 대한공업교육학회지
    • /
    • v.33 no.2
    • /
    • pp.259-272
    • /
    • 2008
  • In order to improve the productivity and quality of boat's mold in leisure boat industry, the development of modelling and machining technology of leisure boat's plug is strongly required. The traditional lines drawing approach by hand required the designer to both create fair curves and to make sure that the curves matched up to each other in the three main drawing views: profile, plan, and section. However, one will find when studying lines drawings in books that the curves might look smooth and fair, but the lines do not agree exactly in the three views. Therefore, the 2 dimensional drawing data of leisure boat are transformed using 3 dimensional design s/w and CAM s/w. In addition, the leisure boat is designed with a 3 dimensional s/w. The NC cutting data are generated by the CAM s/w. The surface characteristics of machined surface are investigated at various cutting conditions such as spindle speed, feed speed, and cutting material.

A Study on the Inflow Pattern of Paint according to the Hole Design of the Drum-base in the Pressure-roller (압송롤러 드럼베이스의 홀 설계에 따른 페인트 유입양상에 대한 연구)

  • Jeong, Nam-Gyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.487-493
    • /
    • 2020
  • Recently, the ministry of environment banned the use of the existing airless method using the spray in painting industrial facilities. Therefore, it is necessary to develop a pressure-roller attached to existing airless painting systems. The hole design of the SUS piping and drum-bases of pressure-rollers currently developed and sold have not been studied in detail, so their efficiency is questionable. In particular, if sufficient paint is not supplied to both ends of the roller, it is necessary to rework with a brush after painting. Therefore, the holes of the drum base need to be distributed so that the paint can flow to both ends of the roller. In this study, numerical analysis was performed to determine the effects of the hole design in the SUS piping and drum-base on the flow patterns of the paint and to suggest more efficient design measures. The analysis results showed that the uniform placement of the holes in the SUS piping is good for the balanced inflow of the paint. For the drum-base, the paint can flow better into both ends of the roller when the holes are concentrated and machined on both ends of the drum-base.

The Development of Height Adjustable Steel Manhole cover (높이조절이 가능한 강재 맨홀뚜껑의 개발)

  • Park, Woo-Cheul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.581-586
    • /
    • 2018
  • Cast iron manhole lids cause environmental pollution during the manufacturing process, and the work environment is very poor. In addition, if the height of the manhole cover does not match the height of the road surface, it causes considerable inconvenience and safety problems. This study proposes a height - adjustable steel manhole cover that can replace cast iron manhole covers and easily match the road surface with the upper surface of the manhole cover. Structural analysis was performed to grasp the design variable of the structure of the manhole cover, satisfying the required quality performance. To fabricate a manhole cover that satisfies the required load capacity, the optimal design for the U-shaped reinforcement structure was made. The cylindrical shape of the height adjustment part and the low frame were formed by bending the steel sheet into a circular shape and then welding. Reinforcing bars were also made by bending a steel plate. The height adjustment groove was machined by a CNC milling machine. Four prototypes were fabricated and a load bearing test was carried out, and new manhole cover was made reflecting results of the test. In the load bearing test, there was no breakage of the welded part, and deformation occurred mainly at the contact area between the groove and gusset plate. Deformation of 1 to 2.7mm occurred due to a load of 450kN. On the other hand, after removing the load, there was almost no residual deformation, and the load bearing evaluation was judged to be satisfactory because the manhole cover could be disassembled and reassembled.

In vivo assessment of Fibroblast growth factor(FGF)-Fibronectin fusion protein coating on titanium;Histomorphometric analysis in rabbit tibia (섬유아세포 성장인자와 파이브로넥틴 복합 단백질로 처리한 타이태늄의 생물학적 효과;가토의 경골을 이용한 조직계측학적 분석)

  • Na, Ho-Kyun;Kim, Tae-Il;Lim, Sang-Hoon;Cho, Ki-Young;Chung, Chong-Pyoung;Han, Soo-Boo;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.1
    • /
    • pp.153-161
    • /
    • 2005
  • 파이브로넥틴은 세포외기질에 존재하는 당단백질로 세포의 부착, 이동, 성장 및 분화에 관여하며, 섬유아세포 성장인자는 세포의 증식 이동 및 분화에 영향을 주는 중요한 성장인자로 알려져 있다. 최근 연구에 의하면, 파이브로넥틴은 조골세포의 타이태늄 임플란트 표면으로 이주와 증식 및 골생성을 촉진하며, 섬유아세포 성장 인자는 파이브로넥틴에 상승작용을 한다고 보고된 바 있다. 이 실험의 목적은 파이브로넥틴 및 섬유아세포 성장인자의 복합 단백질을 이용하여 타이태늄 임플란트의 골 반응을 알아보는 것이다. 체중 2.5 kg 내외의 건강한 18 마리의 웅성가토를 준비하여 무균 사육하였고, 순수 타이태늄을 절삭가공하여 직경 3.5mm, 길이 6mm 의 machined surface를 지니는 screw type 의 임플란트를 준비하였다. 사람의 유전자를 기초로, 유전자 재조합법을 통해, 적절한 primer를 이용하여 얻은 섬유아세포 성장인자를 파이브로넥틴 III 형 분절의 9-10 번 도메인에 결합시켜 얻은 복합 단백질을 준비된 임플란트에 표면처리하여 실험군으로 하였고, 표면처리하지 않은 임플란트를 대조군으로 하여, 가토의 좌우 경골에 각각 2 개씩의 임플란트를 식립하였다. 4주 후, 가토를 희생시켜 각 경골 당 한 개의 임플란트에서 뒤틀림 제거력을 측정하였고 나머지 임플란트 식립 부위 에서는 경골을 포함하는 조직표본을 제작하였다. 조직표본상에서 골접촉이 가장 좋은 3 개의 나사산의 길이를 측정하고, 나사와 접촉하는 골의 길이를 측정하여 골-임플란트 접촉도를 구하고, 같은 부위에서 나사산 사이의 면적과 골이 차지하는 면적을 비교하여 골생성률을 얻었다. 실험군과 대조군의 결과는 Student t-test 를 이용하여 신뢰도 95% 수준에서 통계학적 유의성을 검정하였다. 파이브로넥틴과 섬유아세포 성장인자의 복합 단백질로 표면처리된 임플란트와 표면처리를 하지 않은 임플란트는 뒤틀림 제거력에서는 통계적 유의성이 나타나지 않았으나, 골-임플란트 접촉도와 골생성률에서 복합 단백질로 처리된 임플란트가 통계적으로 유의하게 높은 결과를 보였다. 이상의 연구결과로, 섬유아세포 성장인자와 파이브로넥틴 복합 단백질로 처리한 타이태늄 임플란트가 주변 골 형성을 촉진시켜, 골유합을 증진시킴을 알 수 있었다. 따라서, 복합 단백질이 타이태늄 임플란트의 성공률을 높이기 위한 표면개질 물질로 이용될 가능성을 확인할 수 있었다.

Avoidance of Internal Resonances in Hemispherical Resonator Assemblies from Fused Quartz Connected by Indium Solder

  • Sarapuloff, Sergii A.;Rhee, Huinam;Park, Sang-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.835-841
    • /
    • 2013
  • Modern solid-state gyroscopes (HRG) with hemispherical resonators from high-purity quartz glass and special surface superfinishing and ultrathin gold coating become the best instruments for precise-grade inertial reference units (IRU) targeting long-term space missions. Designing of these sensors could be a notable contribution into development of Korea as a space nation. In participial, 40mm diameter thin-shell resonator from high-purity fused quartz, fabricated as a single-piece with its supporting stem has been designed, machined, etched, tuned, tested, and delivered by STM Co. (ATS of Ukraine) several years ago; an extremely-high Q-factor (upto 10~20 millions) has been shown. Understanding of the best way how to match such a unique sensor with inner glass assembly of the gyro means how to use the high potential in a maximal extent; and this has become the urgent task. Inner quartz glass assembly has a very thin indium (In) layer soldered the resonator and its silica base (case), but effects of internal resonances between operational modal pair of the shell-cup and its side (parasitic) modes can notable degrade the potential of the sensor as a whole, instead of so low level of resonator's intrinsic losses. Unfortunately, there are special combinations of dimensions of the parts (so-called, "resonant sizes"), when intensive losses of energy occurs. The authors proposed to use the length of stem's fixture as an additional design parameter to avoid such cases. So-called, a cyclic scheme of finite element method (FEM) and ANSYS software were employed to estimate different combinations of gyro assembly parameters. This variant has no mismatches of numerical origin due to FEM's discrete mesh. The optimum length and dangerous "resonant lengths" have been found. The special attention has been paid to analyses of 3D effects in a cup-stem transient zone, including determination of a difference between the positions of geometrical Pole of the resonant hemisphere and of its "dynamical Pole", i.e., its real zone of oscillation node. Boundary effects between the shell (cup) and 3D short "beams" (inner and outer stems) have been ranged. The results of the numerical experiments have been compared with the classic model of a quasi-hemispherical shell band with inextensional midsurface, and the solution using Rayleigh's functions of the $1^{st}$ and $2^{nd}$ kinds. To guarantee the truth of the recommended sizes to a designer of the real device, the analytical and FEM results have been compared with experimental data for a party of real resonators. The consistency of the results obtained by different means has been shown with errors less than 5%. The results notably differ from the data published earlier by different researchers.

  • PDF

LED Beam Shaping and Fabrication of Optical Components for LED-Based Fingerprint Imager (LED 빔조형에 의한 초소형 이미징 장치의 제조 기술)

  • Joo, Jae-Young;Song, Sang-Bin;Park, Sun-Sub;Lee, Sun-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1189-1193
    • /
    • 2012
  • The Miniaturized Fingerprint Imager (MFI) is a slim optical mouse that can be used as an input device for application to wireless portable personnel communication devices such as smartphones. In this study, we have fabricated key optical components of an MFI, including the illumination optical components and imaging lens. An LED beam-shaping lens consisting of an aspheric lens and a Fresnel facet was successfully machined using a diamond turning machine (DTM). A customized V-shaped groove for beam path banding was fabricated by the bulk micromachining of silicon that was coated with aluminum using the shadow effect in thermal evaporation. The imaging lens and arrayed multilevel Fresnel lenses were fabricated by electron beam lithography and FAB etching, respectively. The proposed optical components are extremely compact and have high optical efficiency; therefore, they are applicable to ultraslim optical systems.