• Title/Summary/Keyword: machine

Search Result 24,492, Processing Time 0.047 seconds

THE EFFECT OF THERMOCYCLING ON THE DURABILITY OF DENTIN ADHESIVE SYSTEMS (열순환이 상아질 접착제의 결합 내구성에 미치는 영향)

  • Moon, Young-Hoon;Kim, Jong-Ryul;Choi, Kyung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.222-235
    • /
    • 2007
  • The objectives of this study was to evaluate the effect of thermocycling on the ${\mu}TBS$ (microtensile bond strength) to dentin with four different adhesive systems to examine the bonding durability. Freshly extracted $3^{rd}$ molar teeth were exposed occlusal dentin surfaces, and randomly distributed into 8 adhesive groups 3-steps total-etching (Scotchbond Multi-Purpose Plus; SM, All Bond-2; AB), 2-steps total-etching (Single Bond; SB, One Step plus; OS), 2-steps self-etching (Clearfil SE Bond; SE, AdheSE AD) and single-step self-etching systems (Promp L-Pop; PL, Xeno III; XE) Each adhesive system in 8 adhesives groups was applied on prepared dentin surface as an instruction and resin composite (Z250) was placed incrementally and light-cured. The bonded specimens were sectioned with low-speed diamond saw to obtain $1\times1mm$ sticks after 24 hours of storage at $37^{\circ}C$ distilled water and proceeded thermocycling at the pre-determined cycles of 0, 1,000 and 2,000. The ${\mu}TBS$ test was carried out with EZ-tester at 1mm/min. The results of bond strength test were statistically analyzed using one-way ANOVA/ Duncan's test at the a < 0.05 confidence level. Also, the fracture mode of debonded surface and the interface were examined under SEM. The results of this study were as follows ; 1. 3-step total etching adhesives showed stable, but bond strength of 2-step adhesives were decreased as thermocycling stress. 2. SE showed the highest bond strength, but single step adhesives (PL, XE) had the lowest value both before and after thermocycling. 3 Most of adhesives showed adhesive failure. The total-etching systems were prone to adhesive failure and the single-step systems were mixed failure after thermocycling. Within limited results of this study, the bond strength of adhesive system was material specific and the bonding durability was affected by the bonding step/ procedure of adhesive Simplified bonding procedures do not necessarily imply improved bonding performance.

EFFECT OF INTERMITTENT POLYMERIZATION ON THE RATE OF POLYMERIZATION SHRINKAGE AND CUSPAL DEFLECTION IN COMPOSITE RESIN (복합 레진의 간헐적 광중합 방법이 중합 수축 속도와 치아의 교두 변위에 미치는 영향)

  • Kim, Min-Kyung;Park, Sung-Ho;Seo, Deog-Gyu;Song, Yun-Jung;Lee, Yoon;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.341-351
    • /
    • 2008
  • This study investigated the effect of intermittent polymerization on the rate of polymerization shrinkage and cuspal deflection in composite resins. The linear polymerization shrinkage of each composite was measured using the custom-made linometer along with the light shutter specially devised to block the light at the previously determined interval. Samples were divided into 4 groups by light curing method; Group 1) continuous light (60s with light on); Group 2) intermittent light (cycles of 3s with 2s light on & 1s with light off for 90s): Group 3) intermittent light (cycles of 2s with 1s light on & 1s with light off for 120s); Group 4) intermittent light (cycles of 3s with 1s light on & 2s with light off for 180s). The amount of linear polymerization shrinkage was measured and its maximum rate (Rmax) and peak time (PT) in the first 15 seconds were calculated. For the measurement of cuspal deflection of teeth, MOD cavities were prepared in 10 extracted maxillary premolars. Reduction in the intercuspal distance was measured by the custom-made cuspal deflection measuring machine. ANOVA analysis was used for the comparison of the light curing groups and t-test was used to determine significant difference between the composite resins. Pyramid showed the greater amount of polymerization shrinkage than Heliomolar (p < 0.05). There was no significant difference in the linear polymerization shrinkage among the groups. The Rmax was group 4 < 3, 2 < 1 in Heliomolar and group 3 < 4 < 2, 1 in Pyramid (p < 0.05). Pyramid demonstrated greater cuspal deflection than Heliomolar. The cuspal deflection in Heliomolar was group 4 < 3 < 2, 1 and group 4, 3 < 2, 1 in Pyramid (p < 0.05). It was concluded that the reduced rate of polymerization shrinkage by intermittent polymerization can help to decrease the cuspal deflection.

Studies on Seed Germination Characteristics of Rice Cultivar ‘Danmi’ and Its Optimum Seeding Rates for Seedling Raising in Machine Transplanting (단미벼의 발아 특성 및 기계이앙 육묘시 적정 파종량)

  • Kim, Sang-Yeol;Oh, Seong-Hwan;Lee, Jong-Hee;Jeong, Kuk-Hyun;Cho, Jun-Hyeon;Lee, Ji-Yoon;Park, Sung-Tae;Song, You-Chun;Yeo, Un-Sang;Kim, Jeong-Il;Seo, Woo-Duck;Kang, Hang-Won
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.55 no.2
    • /
    • pp.126-132
    • /
    • 2010
  • A high sugar rice cultivar 'Danmi' which has been recently developed and released in the Functional Crop Resource Development Division, Department of Functional Crop, National Institute of Crop Science, has high glucose and sucrose contents but has a poor seed development. This defect poses some problem in ensuring stable seedling establishment in the nursery bed. We examined the germination and seedling emergence characteristics of 'Danmi' and determined an optimum seeding rate for seedling establishment. 'Danmi' seeds has a light 1,000-grain weight of 18.2g compared with Ilmibyeo's 26.7g. The 97.4% of 'Danmi' seeds has specific gravity below 1.0 while only 2.0% of seeds was fully developed with specific gravity above 1.12. However, the reverse is true in the Ilmibyeo seed used as a control cultivar. Although the seed germination of Danmi was 89-91% regardless of seed specific gravity but at a slower rate than Ilmibyeo regardless of water soaking temperatures of $20-30^{\circ}C$ because of high seed amount of specific gravity below 1.0 in 'Danmi'. It took 2~4 days longer of seed soaking in the Danmi seeds than Ilmibyeo before germination. 'Danmi' has low normal seedling emergence rate than Ilmibyeo in the seedbed soil due to high percentage of abnormal seedlings like stunting and incomplete growth. Normal seedling emergence rate of 'Danmi' in the seedbed was 62.6~64.9% for 10-day old seedling and 83.5~86.7% for 30-day old seedling which is lower by 29.6~30.0% and 11.3~12%, respectively than Ilmibyeo. Although 'Danmi' has low normal seedling emergence rate, but it has greater seed number per weight basis. Therefore, based on the normal seedling number per unit area of Ilmibyeo(control cultivar) for seedling rate of 10-day and 30-day old seedlings, the recommended seeding rate of 'Danmi' for transplanting rice is 220g seeds for 10-day old seedling and 130g for 30-day old seedling per nursery box, which is equivalent to 1.5 times seed volumes of Ilmibyeo.

Status of Brain-based Artistic Education Fusion Study - Basic Study for Animation Drawing Education (뇌기반 예술교육 융합연구의 현황 - 애니메이션 드로잉 교육을 위한 기초연구)

  • Lee, Sun Ju;Park, Sung Won
    • Cartoon and Animation Studies
    • /
    • s.36
    • /
    • pp.237-257
    • /
    • 2014
  • This study is the process of performing the interdisciplinary fusion study between multiple fields by identifying the status on the previous artistic education considering the brain scientific mechanism of image creativity and brain-based learning principles. In recent years, producing the educational methods of each field as the fusion study activities are emerging as the trend and thanks to such, the results of brain-based educational fusion studies are being presented for each field. It includes artistic fields such as music, art and dance. In other words, the perspective is that by understanding the operating principles of the brain while creativity and learning is taking place, when applying various principles that can develop the corresponding functions as a teaching method, it can effectively increase the artistic performance ability and creativity. Since the animation drawing should be able to intuitively recognize the elements of movement and produce the communication with the target beyond the delineative perspective of simply drawing the objects to look the same, it requires the development of systematic educational method including the methods of communication, elements of higher cognitive senses as well as the cognitive perspective of form implementation. Therefore, this study proposes a literature study results on the artistic education applied with brain-based principles in order to design the educational model considering the professional characteristics of animation drawing. Therefore, the overseas and domestic trends of the cases of brain-based artistic education were extracted and analyzed. In addition, the cases of artistic education studies applied with brain-based principles and study results from cases of drawing related education were analyzed. According to the analyzed results, the brain-based learning related to the drawing has shown a common effect of promoting the creativity and changes of positive emotion related to the observation, concentration and image expression through the training of the right brain. In addition, there was a case of overseas educational application through the brain wave training where the timing ability and artistic expression have shown an enhancement effect through the HRV training, SMR, Beta 1 and neuro feedback training that strengthens the alpha/seta wave and it was proposing that slow brain wave neuro feedback training contributes significantly in overcoming the stress and enhancing the creative artistic performance ability. The meaning of this study result is significant in the fact that it was the case that have shown the successful application of neuro feedback training in the environment of artistic live education beyond the range of laboratory but the use of the machine was shown to have limitations for being applied to the teaching methods so its significance can be found in providing the analytical foundation for applying and designing the brain-based learning principles for future animation drawing teaching methods.

Evaluation on the radiation exposure from activated wedge filter (10MV 이상 고에너지 사용시 wedge filler의 방사화가 작업환경에 미치는 영향평가)

  • Lee HwaJung;Kim DaeYoung;Kim WonTaek;Lee KangHyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.69-79
    • /
    • 2004
  • In the process of photon treatments, linear accelerators with energies higher than 10 MV produce neutrons through the (${\gamma}$, n) interactions with the composite materials of the linac head md these materials further produce the induced radiations. We investigate the possible risks from these induced radiations especially in the wedge filters to the radiation workers. Wedge filters are used to modify the isodose profiles in the radiation treatment using the linear accelerator and always be handled by the radiation workers. For the background radiation, we measured the radiation in both the waiting room and the outside of the building for two hospitals, S and H. The results of S hospital were $0.11\;{\mu}Sv/hr$ and $0.10\;{\mu}Sv/hr$ for waiting room and outside respectively, and in the case of H hospital, they were $0.12\;{\mu}Sv/hr$ and $0.11\;{\mu}Sv/hr$. Using a survey meter, we measured the radiation from wedge filters inserted in 10 MV and 15 MV Siemens linear accelerators. The time series measurements were done in ${\sim}1$ minutes after exposure of 5 Gy of monitor units for the field size of $25{\times}25cm^2$. The starting value of 10 MV machine was about $3.26\;{\mu}Sv/hr$, which was three times higher than that of 10 MV. The measured radiation was from $^{28}Al$ and $^{53}Fe$ with a half life of 3.5 min. If the treatment patients are $20{\sim}50$ per day and the number of process of wedge filter change per patient is one or two, the annual dose equivalent is $0.08{\sim}0.4\;mSv$ for 10 MV, and $0.27{\sim}1.36\;mSv$ for 15 MV, which are in the range of dose equivalent limits of radiation workers.

  • PDF

An Integrated Model based on Genetic Algorithms for Implementing Cost-Effective Intelligent Intrusion Detection Systems (비용효율적 지능형 침입탐지시스템 구현을 위한 유전자 알고리즘 기반 통합 모형)

  • Lee, Hyeon-Uk;Kim, Ji-Hun;Ahn, Hyun-Chul
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.1
    • /
    • pp.125-141
    • /
    • 2012
  • These days, the malicious attacks and hacks on the networked systems are dramatically increasing, and the patterns of them are changing rapidly. Consequently, it becomes more important to appropriately handle these malicious attacks and hacks, and there exist sufficient interests and demand in effective network security systems just like intrusion detection systems. Intrusion detection systems are the network security systems for detecting, identifying and responding to unauthorized or abnormal activities appropriately. Conventional intrusion detection systems have generally been designed using the experts' implicit knowledge on the network intrusions or the hackers' abnormal behaviors. However, they cannot handle new or unknown patterns of the network attacks, although they perform very well under the normal situation. As a result, recent studies on intrusion detection systems use artificial intelligence techniques, which can proactively respond to the unknown threats. For a long time, researchers have adopted and tested various kinds of artificial intelligence techniques such as artificial neural networks, decision trees, and support vector machines to detect intrusions on the network. However, most of them have just applied these techniques singularly, even though combining the techniques may lead to better detection. With this reason, we propose a new integrated model for intrusion detection. Our model is designed to combine prediction results of four different binary classification models-logistic regression (LOGIT), decision trees (DT), artificial neural networks (ANN), and support vector machines (SVM), which may be complementary to each other. As a tool for finding optimal combining weights, genetic algorithms (GA) are used. Our proposed model is designed to be built in two steps. At the first step, the optimal integration model whose prediction error (i.e. erroneous classification rate) is the least is generated. After that, in the second step, it explores the optimal classification threshold for determining intrusions, which minimizes the total misclassification cost. To calculate the total misclassification cost of intrusion detection system, we need to understand its asymmetric error cost scheme. Generally, there are two common forms of errors in intrusion detection. The first error type is the False-Positive Error (FPE). In the case of FPE, the wrong judgment on it may result in the unnecessary fixation. The second error type is the False-Negative Error (FNE) that mainly misjudges the malware of the program as normal. Compared to FPE, FNE is more fatal. Thus, total misclassification cost is more affected by FNE rather than FPE. To validate the practical applicability of our model, we applied it to the real-world dataset for network intrusion detection. The experimental dataset was collected from the IDS sensor of an official institution in Korea from January to June 2010. We collected 15,000 log data in total, and selected 10,000 samples from them by using random sampling method. Also, we compared the results from our model with the results from single techniques to confirm the superiority of the proposed model. LOGIT and DT was experimented using PASW Statistics v18.0, and ANN was experimented using Neuroshell R4.0. For SVM, LIBSVM v2.90-a freeware for training SVM classifier-was used. Empirical results showed that our proposed model based on GA outperformed all the other comparative models in detecting network intrusions from the accuracy perspective. They also showed that the proposed model outperformed all the other comparative models in the total misclassification cost perspective. Consequently, it is expected that our study may contribute to build cost-effective intelligent intrusion detection systems.

Product Recommender Systems using Multi-Model Ensemble Techniques (다중모형조합기법을 이용한 상품추천시스템)

  • Lee, Yeonjeong;Kim, Kyoung-Jae
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.2
    • /
    • pp.39-54
    • /
    • 2013
  • Recent explosive increase of electronic commerce provides many advantageous purchase opportunities to customers. In this situation, customers who do not have enough knowledge about their purchases, may accept product recommendations. Product recommender systems automatically reflect user's preference and provide recommendation list to the users. Thus, product recommender system in online shopping store has been known as one of the most popular tools for one-to-one marketing. However, recommender systems which do not properly reflect user's preference cause user's disappointment and waste of time. In this study, we propose a novel recommender system which uses data mining and multi-model ensemble techniques to enhance the recommendation performance through reflecting the precise user's preference. The research data is collected from the real-world online shopping store, which deals products from famous art galleries and museums in Korea. The data initially contain 5759 transaction data, but finally remain 3167 transaction data after deletion of null data. In this study, we transform the categorical variables into dummy variables and exclude outlier data. The proposed model consists of two steps. The first step predicts customers who have high likelihood to purchase products in the online shopping store. In this step, we first use logistic regression, decision trees, and artificial neural networks to predict customers who have high likelihood to purchase products in each product group. We perform above data mining techniques using SAS E-Miner software. In this study, we partition datasets into two sets as modeling and validation sets for the logistic regression and decision trees. We also partition datasets into three sets as training, test, and validation sets for the artificial neural network model. The validation dataset is equal for the all experiments. Then we composite the results of each predictor using the multi-model ensemble techniques such as bagging and bumping. Bagging is the abbreviation of "Bootstrap Aggregation" and it composite outputs from several machine learning techniques for raising the performance and stability of prediction or classification. This technique is special form of the averaging method. Bumping is the abbreviation of "Bootstrap Umbrella of Model Parameter," and it only considers the model which has the lowest error value. The results show that bumping outperforms bagging and the other predictors except for "Poster" product group. For the "Poster" product group, artificial neural network model performs better than the other models. In the second step, we use the market basket analysis to extract association rules for co-purchased products. We can extract thirty one association rules according to values of Lift, Support, and Confidence measure. We set the minimum transaction frequency to support associations as 5%, maximum number of items in an association as 4, and minimum confidence for rule generation as 10%. This study also excludes the extracted association rules below 1 of lift value. We finally get fifteen association rules by excluding duplicate rules. Among the fifteen association rules, eleven rules contain association between products in "Office Supplies" product group, one rules include the association between "Office Supplies" and "Fashion" product groups, and other three rules contain association between "Office Supplies" and "Home Decoration" product groups. Finally, the proposed product recommender systems provides list of recommendations to the proper customers. We test the usability of the proposed system by using prototype and real-world transaction and profile data. For this end, we construct the prototype system by using the ASP, Java Script and Microsoft Access. In addition, we survey about user satisfaction for the recommended product list from the proposed system and the randomly selected product lists. The participants for the survey are 173 persons who use MSN Messenger, Daum Caf$\acute{e}$, and P2P services. We evaluate the user satisfaction using five-scale Likert measure. This study also performs "Paired Sample T-test" for the results of the survey. The results show that the proposed model outperforms the random selection model with 1% statistical significance level. It means that the users satisfied the recommended product list significantly. The results also show that the proposed system may be useful in real-world online shopping store.

Influence of the curing time for the adhesive on the oxygen-inhibited layer thickness and the shear bond strength to dentin (광조사 시간이 접착제의 표면 미중합층의 두께와 전단접착강도에 미치는 영향에 관한 연구)

  • Choi, Yong-Hoon;Bae, Ji-Hyun;Son, Ho-Hyun;Lee, In-Bog;Um, Chung-Moon;Baek, Seung-Ho;Kim, Oh-Young;Kim, Chang-Keun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.177-184
    • /
    • 2004
  • Objectives : This study investigated the hypothesis that increasing light-curing time would leave the oxygen-inhibited layer (OIL) of the adhesive thinner, and in turn, result in lower shear bond strength (SBS) than those obtained by the routine curing procedures. Methods:120 human extracted posterior teeth were randomly divided into three groups for bonding with three adhesives:All Bond 2/sup (R)/, One Step/sup (R)/, and Adper Prompt/sup (R)/. They were subsequently divided into four subgourps with different light-curing time (10, 20, 30 and 60s). The assigned adhesives were applied on superficial occlusal dentin according to the manufacturer's instructions and cured with one of the four curing times. Composite resin cylinder, 2.35㎜ in diameter, were built on the cured adhesive and light-cured for 40s. SBS were measured after 24h from the bonding using a universal testing machine (crosshead speed 1.0 ㎜/min). The relative thickness of the OIL and the degree of conversion (DC) were determined from the adhesive on a slide glass using FT-NIR in an absorbance mode. Data were analysed with One-way ANOVA and Duncan's multiple test (p〈0.05), Results:With increasing cure time, although there were no significant difference in th SBS of One-step and Adper Prompt (p〉0.05), those of All Bond 2 decreased significantly (p〈0.05). The relative thicknesses of the OIL on each adhesive were not affected by the cure time (p〉0.05). Although the DC of All-Bond 2 were statistically not different with increasing cure time (p〉0.05), those of One-Step and Adper Prompt showed an increasing trends with increasing cure time (p〈0.05). Conclusions:Increasing light-curing time did not affect on the relative thickness of the OIL of the adhesives, and in turn, on the SBS to dentin.

THE BONDING DURABILITY OF RESIN CEMENTS (레진시멘트의 접착 내구성에 관한 연구)

  • Cho, Min-Woo;Park, Sang-Hyuk;Kim, Jong-Ryul;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.343-355
    • /
    • 2007
  • The objectives of this study was to evaluate the durability of 4 resin cements by means of microtensile bond strength test combined with thermocycling method and fractographic FE-SEM analysis. Experimental groups were prepared according to thermocycling (0, 1,000, 5,000) and the kind of resin cements, those were Variolink II, Multilink, Panavia F 2.0, Rely X Unicem. Flat dentin surfaces were created on mid-coronal dentin of extracted third molars. Then fresh dentin surface was grounded with 320-grit silicon carbide abrasive papers to create uniform smear layers. Indirect composite block (Tescera, Bisco Inc., Schaumburg, IL, USA) was fabricated ($12\;{\times}\;12\;{\times}\;6\;mm^3$). It's surface for bonding to tooth was grounded with silicon carbide abrasive papers from 180- to 600-grit serially, then sandblasted witk $20\;-\;50\;{\mu}m$ alumina oxide. According to each manufacturer's instruction, dentin surface was treated and indirect composite block was luted on it using each resin cement. For Rely X Unicem, dentin surface was not treated. The bonded tooth-resin block were stored in distilled water at $37^{\circ}C$ for 24 hours. After thermocycling, the bonded tooth-resin block was sectioned occluso-gingivally to 1.0 mm thick serial slabs using all Isomet slow-speed saw (Isomet, Buehler Ltd, Lake Bluff, IL, USA). These sectioned slabs were further sectioned to $1.0\;{\times}\;1.0\;mm^2$ composite-dentin beams. The specimens were tested with universal testing machine (EZ-Test, Shimadzu, Japan) at a crosshead speed of 1.0 mm/min with maximum load of 500 N. The data was analyzed using one-way ANOVA and Duncan's multiple comparison test at $p\;{\leq}\;0.05$ level. Within the limited results, we conclude as follows; 1. The bond strength of Variolink II was evaluated the highest among experimental groups and was significantly decreased after 1,000 thermocycling (p < 0.05). 2. The bond strength of Multilink was more affected by thermocycling than the other experimental groups and significantly decreased after 1,000 thermocycling (p < 0.05). 3. Panavia F 2.0 and Rely X Unicem showed the gradually decreased tendency of microtensile bond strength according to thermocycling but there was no significant difference (p > 0.05). 4. Adhesive based-resin cements showed lower bond strength with or without thermocycling than composite based-resin cements. 5. Variolink II & Multilink showed high bond strength and mixed failure, which was occurred with a thin layer of luting resin cement before thermocycling and gradually increased adhesive failure along the dentin surface after thermocycling. The bonding performance of resin cement can be affected by application procedure and chemical composition. Composite based-resin cement showed higher bond strength and durability than adhesive based-resin cement.

A Clinical Study of Tinnitus (耳鳴에 관한 임상적 연구)

  • Choi, In-Hwa
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.14 no.2
    • /
    • pp.134-145
    • /
    • 2001
  • Introduction: Noises in the ear, whether real or imagined, are called tinnitus. Subjective causes of tinnitus(which is heard only by the patient) are extremely common and the majority of them are treated conservatively. For certain individuals their tinnitus is a major handicap; for others a trivial concern. The most common from of subjective tinnitus is a rushing, hissing or buzzing noise; it is frequently associated with sensorineural heanng loss. The patient may be unaware of the hearing loss, especially if it is a high frequency deficit of moderate severity. The character of the tinnitus may give a clue to the etiology. But the patient often has difficulty in explaining his/her tinnitus in absolute terms, as they have no other tinnitus with which to compare it but their own Tinnitus, like pain, is a subjective state and trying to objectively assess the severity is problematic. Audiological techniques to match subjective loudness to machine-produced noise may offer some help, in that sound intensity matches can bear little correspondence to subjective complaint. In spite of many studies, most patients presently seen complaining of tinnitus are told by their doctors that there is no treatment and that they will have to learn to live with this symptom. Objectives: To perform a clinical analysis of tinnitus and estimate the efficacy of Oriental Medical treatment according to the Byeonjeung(辨證). Subject: We studied 34 patients with complaints of tinnitus who had visited Pundang Cha Oriental Medicine Hospital Department of Otorhinolaryngology from March 1998 to February 2000. All of them had been treated 2 or 3 times a week with acupuncture treatment and had taken herbs according to the Byeonjeung(辨證) method. It was therefore possible for me to know whether their symptoms improved or not. Parameters Observed and Method: We treated them with acupuncture & herb-medication. Sometimes we gave them moxibustion or negative therapy with bloodletting at the acupuncture points(耳門, 聽宮, 聽會). Parameters Observed 1) Distribution of age & sex 2) Chief complaints 3) The sites of tinnitus 4) The quality of tinnitu 5) The duration of disease 6) The problem induced tinnitus 7) Factors increasing disease severity 8) The classification of the Byeonjeung(辨證) 9) The efficacy of treatments Results: 1. Age and sex distribution: The most common occurrence was found in males in their twenties: 6 males($17.7\%$), and in females in their thirties and over sixty: 8 females($23.5\%$). Total patient numbers for men and women were 20 men($58.8\%$), 14 women ($41.2\%$). 2. The most frequent major complaints were hearing disturbances related to tinnitus; and dizziness with tinnitus; each comprising 10 cases($29.4\%$). There were also 7 patients($20.6\%$) with only tinnitus. 3. Tinnitus sites: 13($38.2\%$) said that they felt tinnitus in both ears, equally. In the right ear, 9($26.5\%$), in the left, 6($17.7\%$). 4. The most frequent descriptive symptoms of tinnitus were: humming, hissing, buzzing etc. 5. The duration of disease. 14cases($41.2\%$) had a duration of less than 1 year. 6. 15cases($44.1\%$) complained that it was hard to watch TV or make a phone call because of tinnitus. 10 cases($29.4\%$) complained about depression. 7. Factors increasing severity of tinnitus: ⅰ) fatigue: 18cases($52.9\%$) ⅱ) stress/ tension: 10 cases($29.4\%$) ⅲ) alcohol and tobacco: 5cases($l4.7\%$) 8. Classification through Byeonjeung : ⅰ) 19 cases($55.9\%$) were classified as showing Deficiency syndrome. ⅱ) 15 cases($44.l\%$) were classified as showing Excess syndrome. The deficiency of Qi was 7($20.6\%$), deficiency of Xue, 8($23.5\%$) and insufficiency of the Kidney Yin & Yang, 4($11.8\%$). The flare of Liver fire was 8($23.5\%$) and phlegm-fire, 7($20.6\%$), 9. The efficacy of treatments showed: an improvement in 17cases($50.0\%$); no real improvement or changes in 13 cases($38.2\%$); and some worsening in 4 cases($11.8\%$). In the group with deficiency in Qi, 4($57.1\%$) improved, 1($14.3\%$) showed no change and 2($28.6\%$) were aggravated. In the cases of deficiency in Xue, 6($75.0\%$) improved, 2($25.0\%$) showed no change. In the cases of insufficiency of Kidney Yin & Yang, 3($75.0\%$) showed no change and 1($25.0\%$) were aggravated. In the group of flare of Liver fire, 4($50.0\%$) improved, 3($37.5\%$) no change and 1($12.5\%$) were aggravated. In the cases of phlegm-fire, 3($42.9\%$) improved, 4($57.1\%$) showed no change. Conclusion: We would recommend that any further studies of tinnitus utilize trial treatments of longer than 2 months duration, as any positive effects observed in our study showed that improvement occurred fairly slowly. And we suggest that this study could be utilized as a reference for clinical Oriental Medical treatment of tinnitus. If we try to apply music or sound therapy treatment properly combined with ours, we expect it to provide psycological stability in addition to inducing masking effects, even though it may not directly decrease or completely remove tinnitus.

  • PDF