• Title/Summary/Keyword: m_1)-system$

Search Result 13,976, Processing Time 0.046 seconds

Analysis of the M/G/1 Queueing System with Randomized Control of T-Policy ((p, T)-정책을 갖는 M/G/1 대기행렬 시스템의 분석)

  • Lee, Doo Ho;Chae, Kyung C.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.33 no.4
    • /
    • pp.419-423
    • /
    • 2007
  • In this paper, we consider the M/G/1 queueing system with randomized control of T-policy. Whenever the busy period ends, the server is turned off and takes multiple vacations whose interval is fixed time T with probability p or stays on and waits for arriving customers with probability 1-p. We introduce the cost function and determine the optimal combination of (p, T) to minimize the average cost per unit time.

A Batch Arrival Queue with Bernoulli Vacation Schedule under Multiple Vacation Policy

  • Choudhury Gautam;Madan Kailash C.
    • Management Science and Financial Engineering
    • /
    • v.12 no.2
    • /
    • pp.1-18
    • /
    • 2006
  • We consider an $M^x/G/1$ queueing system with Bernoulli vacation schedule under multiple vacation policy. where after each vacation completion or service completion the server takes sequence of vacations until a batch of new customer arrive. This generalizes both $M^x/G/1$ queueing system with multiple vacation as well as M/G/1 Bernoulli vacation model. We carryout an extensive analysis for the queue size distributions at various epochs. Further attempts have been made to unify the results of related batch arrival vacation models.

Micro-screening Method for the Anticomplement Substances from Natural Resources (천연유래의 항보체 활성물질 선발을 위한 미량탐색법)

  • Oh, Sei-Ryang;Jung, Keun-Young;Lee, Hyeong-Kyu
    • Applied Biological Chemistry
    • /
    • v.39 no.2
    • /
    • pp.147-152
    • /
    • 1996
  • To screen inhibitors on complement system from natural resources, micro-screening method was established by using hemolytic complement assay. Complement fixation reaction was carried out in the microplate system. For standard hemolysis (50% hemolysis) of the classical pathway (CP), hemolysin and complement serum were diluted to $1/75{\sim}1/100\;and\;1/80{\sim}1/120$, respectively, when sheep erythrocytes were $5.0{\times}10^8\;cells/ml$. In case of the alternative pathway (AP), complement serum was diluted to 1/5 and EGTA and $Mg^{2+}$ were added 4 mM, $4{\sim}8\;mM$, respectively, when rabbit erythrocytes were $4.0{\times}10^8\;cells/ml$. Dimethyl sulfoxide was used for the assay of non-aquous soluble compounds or extracts and its final concentration was not more than 1%. Three phenylpropanoids showed anticomplementary activities in proportion to the concentration for both pathways and rosmarinic acid exihibited the highest inhibitory activities: $5.4{\pm}3.6%(0.063\;mM){\sim}95.8{\pm}0.2%(0.5\;mM)\;and\;35.1{\pm}0.9%(0.063\;mM){\sim}95.6{\pm}1.1%(1\;mM)$ on the CP and the AP, respectively.

  • PDF

Mapping Technique for Heavy Snowfall Distribution Using Terra MODIS Images and Ground Measured Snowfall Data (Terra MODIS 영상과 지상 적설심 자료를 이용한 적설분포도 구축기법 연구)

  • Kim, Saet-Byul;Shin, Hyung-Jin;Lee, Ji-Wan;Yu, Young-Seok;Kim, Seong-Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.4
    • /
    • pp.33-43
    • /
    • 2011
  • This study is to make snowfall distribution map for the 4 heavy snowfall events of January 2001, March of 2004, December of 2005 and January of 2010, and compare the results for three cases of construction methods. The cases are to generate the map by applying IDW(Inverse Distance Weighting) interpolation to 76 ground measured snowfall point data (Snow Depth Map; SDM), mask out the SDM with the MODIS snow cover area (MODIS SCA) of Terra MODIS (MODerate resolution Imaging Spectroradiometer) (SDM+MODIS SCA; SDM_M), and consider the snowdepth lapse rate of snowfall by elevation (Digital Elevation Model; DEM) to the second case (SDM_M+DEM; SDM_MD). By applying the MODIS SCA, the SCA of 4 events was 62.9%, 44.1%, 52.0%, and 69.0% for the area of South Korea. For the average snow depth, the SDM_M decreased 0.9cm, 1.9cm, 0.8cm, and 1.5cm compared to SDM and the SDM_MD increased 1.3cm, 0.9cm, 0.4cm, and 1.2cm respectively.

Development of Daylighting System with Modified Light Pipe for Longer Transmission Distance and Higher Illuminance

  • Vu, Hoang;Kim, Youngil;Park, Chaehwan;Park, Jongbin;Bae, Hojune;Shin, Seoyong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.93-102
    • /
    • 2021
  • In this research, we present a natural lighting system with transmission distance of 30m and lighting efficiency of 35% (30m standard) for operating hours of 7h/day (based on clear sky). The system is composed of parabolic reflective mirror and modified light pipe that can secure more than 88% of light concentration efficiency. The light loss rate of newly designed light pipe transmission system is demonstrated to 0.8 %/m in the straight-line part and 2%/m in the curved part. Modified light pipe daylighting system shows better performance over fiber optic daylighting system in terms of transmission distance (1.5 times longer) and illuminance (3.05 times higher).

A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume (Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰)

  • Kim, Jin Gu;Ham, Jun Cheol;Oh, Shin Hyun;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • Purpose It is intended to figure out the errors derived from changes in depth and volume when measuring the Standard source and 99mTc-pertechnetate by using a Dose calibrator. Then recommend appropriate measurement depth and volume. Materials and Methods As a Dose calibrator, CRC-15βeta and CRC-15R (Capintec, New Jersey, USA) was used, and the measurement sources were 57Co, 133Ba, 137Cs and 99mTc-pertechnetate was also adopted due to its high frequency of use. The Standard source was respectively measured the changes according to its depth without changing the volume, in a range of 0 cm to 15 cm from the bottom of the ion chamber. 99mTc-pertechnetate was measured at each depth by changing the volume with 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL and 0.9 mL Respectively. And the depth range was from 0 cm to 15 cm at the bottom of the ion chamber. Results In the case of Standard source 57Co, 133Ba, 137Cs and 99mTc-pertechnetate, there were significant differences according to the measurement depth(p<0.05). 99mTc-pertechnetate has a negative correlation coefficient according to the depth, and the error of the measured value was negligible at a depth from 0 cm to 7 cm at 0.3 mL and 0.5 mL, and the range of error increased as the volume increased. Conclusion In clinical practice, it is sometimes installed differently than the Standard depth recommended by the equipment company. If it's measured at the recommended depth and volume, it could be thought that unnecessary exposure of the operator and the patient will be reduced, and more accurate radiation exams will be possible in quantitative analysis.

Wastewater Flowrate Analysis of Drainage Basin for Application of Total Water Pollution Load Management System (수질오염총량관리제도 적용을 위한 도시유역의 하수발생량 분석)

  • Kwon, Jun-Hee;Park, In-Hyeok;Ha, Sung-Ryoung
    • Journal of Wetlands Research
    • /
    • v.11 no.1
    • /
    • pp.75-82
    • /
    • 2009
  • The regulation of emission concentration for stream water qualities doesn't control quantitative increase on pollution loads, it has limits for improvement of water qualities. Total water pollution load management system(TMDL) can control the total amount of pollutant in waste water which is allowed to assign and control the total discharged pollutant loads in a permissible level. When it comes to generated wastewater value of TMDL system, there is difference between calculated value based on individual pollutant unit load and observed value. Calculated sewer inflow, calculated sewer outflow, measured sewer inflow, and measured sewer outflow at dry season are $26,460.9m^3$/d, $17,778.6m^3$/d, $17,106.1m^3$/d and $19,033.9m^3$/d respectively, Calculated sewer inflow, calculated sewer outflow, measured sewer inflow, and measured sewer outflow at rainy season are $49,512.2m^3$/d, $18,628.7m^3$/d, $30,918.2m^3$/d, $19,700.7m^3$/d respectively. This result presents the necessity to acquire the precise observed data to fulfill the efficient TMDL system.

  • PDF

Analysis on G/M/1 queue with two-stage service policy

  • KIM SUNGGON;KIM JONGWOO;LEE EUI YONG
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2004.11a
    • /
    • pp.295-300
    • /
    • 2004
  • We consider a G/M/1 queue with two-stage service policy. The server starts to serve with rate of ${\mu}1$ customers per unit time until the number of customers in the system reaches A. At this moment, the service rate is changed to that of ${\mu}2$ customers per unit time and this rate continues until the system is empty. We obtain the stationary distribution of the number of customers in the system.

  • PDF

MURO - Mangpo high school Unmanned Robotic Observatory

  • Kim, Hyunjong;Pak, Soojong;Kim, Youngjong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.52.1-52.1
    • /
    • 2016
  • We introduce the characteristics and performance of the 0.25m telescope at Mangpo high school Unmanned Robotic Observatory (MURO) which was established in Yangpyeong-gun, Gyeongi-do, KOREA in 2015 January. MURO system included Astrohaven 2.1m non-rotation fiberglass clamshell dome, Paramount MEII mount, Takahashi CCA 0.25m wide field telescope, FLI PL 16803 4K CCD with 7-positions filter wheel system, all sky camera and point grey wide field camera, IR 4 chanel heat sensor camera for security, DAVIS realtime weather cast, and power controled by ARS system. All control softwares are from off-the-shelf products based on Windows 7 OS to be easily operated and maintained. We expect to perform variety of science programs ranging from supernovae follow-up observation to narrow band imaging survey as well as science class activities at Mangpo high school.

  • PDF

Vacancy Ordering and Physical Properties in Defect NaCl-type Solids; M-X (M = Yb, Y, X = S, Se) System

  • Lee Ji-Yun;Kim Sung-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.1
    • /
    • pp.64-74
    • /
    • 1994
  • The nonstoichiometric chalcogenides with NaCl-type structure were prepared and the physical and structural properties were studied. The homogeneous range and the structural change were studied based on X-ray powder diffractions using Rietveld-type full-profile fitting technique. Wide homogeneous ranges were observed in Y-S and Y-Se systems, and relatively narrow homogeneous ranges were observed in Yb-S and Yb-Se systems. Both in $Yb_{1-x}S\;and\;Yb_{1-x}Se$, a vacancy ordering transition occurred in (111) plane direction. The ordered superstructure had cubic symmetry(Fm$\bar{3}m) with doubled unit cell "a" parameter compared to the original NaCl-type. The superlattice developed in a continuous second-order transitiion was characterized by the reduced waved vector k= $(a^*+b^*+c^*)/2$. Y-S system had metallic, and YSe, YbSe system had semiconducting properties in their homogeneous ranges. It was observed that the change of electronic transport properties in extended homogeneous range did not depend on the relativeratio of metal to nonmetal, but on the quantities of vacancies.