• 제목/요약/키워드: m_1)-system$

검색결과 13,976건 처리시간 0.042초

Construction of the Smoke Exhaust System and Its Applicability by the Fire Model Test for a Bidirectional Tunnel (대면교행터널에서 배연시스템의 구축과 화재모형실험에 의한 적정성 평가)

  • Lee Sang-Eun;Lee Chang-Woo
    • Tunnel and Underground Space
    • /
    • 제15권6호
    • /
    • pp.452-461
    • /
    • 2005
  • In a bidirectional tunnel, the accident rate is 1.5 times as high as that of one directional tunnel , the risk of a fire is increased. On fire, there is a problem that the jet fan should not be operated until completion of refuge. To be special, as the great damages occur owing to the expansion of smoke in long tunnels, there is a need to minimize fatality by constructing cross passage and smoke removal system. This study aims at verifying the efficiency of smoke exhaust system through fire propagation simulation as well as scale model test. The results show that completion of escape through emergency exit requires 335 seconds, while addition of smoke exhaust system reduce the escape time to 185 seconds. Also, near the fire source temperature decreased by about $60^{\circ}C$. Without the exhaust system, fire propagation speed was in the range of 0.36 and 0.82 m/s, and it dropped to $0.27\~0.58\;m/s$ with the exhaust system on. Taking into account the escape speed of tunnel users, usually $0.7\~1.0\;m/s$, the emergency exit built every 150m is sufficient for the safe egress. The ultimate goal of this study is to provide fundamental information for the smoke exhaust system in bidirectional tunnels.

A Numerical Study on the Performance Analysis of a Solar Air Heating System with Forced Circulation Method (강제순환 방식의 공기가열식 태양열 집열기의 성능분석에 관한 수치해석 연구)

  • Park, Hyeong-Su;Kim, Chul-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제18권3호
    • /
    • pp.122-126
    • /
    • 2017
  • The aim of this study was to develop a device for solving the heating problem of living space using heated air, utilizing a simple air heater type collector for solar energy. At the present time, this study assessed the possibility of a development system through theoretical calculations for the amount of available energy according to the size change of the air-heated solar energy collector. To produce and supply hot water using the heat energy of the sun, hot water at $100^{\circ}C$ or less was produced using a flat or vacuum tube type collector. The purpose of this study was to research the air heating type solar collector that utilizes heating energy with heating air above $75^{\circ}C$, by designing and manufacturing an air piping type solar collector that is a simpler type than a conventional solar collector system. The analysis results were obtained for the generated air temperature ($^{\circ}C$) and the production of air (kg/h) to determine the performance of air heating by an air-heated solar collector according to the heat transfer characteristics in the collector of the model when a specified amount of heat flux was dropped into a solar collector of a certain size using PHOENICS, which is a heat flow analysis program applying the Finite Volume Method. From the analysis result, the temperature of the air obtained was approximately $40.5^{\circ}C$, which could be heated using an air heating tube with an inner diameter of 0.1m made of aluminum in a collector with a size of $1.2m{\times}1.1m{\times}0.19m$. The production of air was approximately 161 m3/h. This device can be applied to maintain a suitable environment for human activity using the heat energy of the sun.

Analysis of Relationship Between Injection Dose and Exposure Dose in PET/CT Scan: Initial Study (PET/CT에서 방사성 의약품 주입량이 방사선 피폭에 미치는 영향분석: 초기연구)

  • Park, Hoon-Hee;Lyu, Kwang-Yeul
    • Journal of radiological science and technology
    • /
    • 제34권4호
    • /
    • pp.351-357
    • /
    • 2011
  • The $^{18}F$-FDG is one of the widely used isotopes for PET/CT scans. Dose amount injected to the patient depends on the characteristics of PET/CT systems. Obviously, the technologists who contact with patients would be exposed as well. In this study, we evaluated the exposed dose of the technologist who works on the PET/CT scanner. The exposed dose were measured every month with the TLDs from 6 technologists. Each technologist is shift-worker who manages 3 different PET/CT systems(Scanner 1(S1): 0.15 mCi/kg, Scanner 2(S2): 0.17 mCi/kg, Scanner 3(S3): 0.12 mCi/kg). The average exposed doses of technologists for each PET/CT system were measured as 0.76 mSv for S1, 0.93 mSv for S2 and 0.47 mSv for S3. The maximum dose was 1.12 mSv and minimum was 0.42 mSv. The results showed that there was a correlation between exposed dose and PET/CT system(p<0.005). Less injected dose for patient occurs less exposed dose for technologist. Various studies for the low dose PET/CT system are required for not only the patient but also the technologist.

Improvement of Transformation Efficiency Through In Vitro Methylation and SacII Site Mutation of Plasmid Vector in Bifidobacterium longum MG1

  • Kim, Jin-Yong;Wang, Yan;Park, Myeong-Soo;Ji, Geun-Eog
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권6호
    • /
    • pp.1022-1026
    • /
    • 2010
  • The different cleavage patterns of pYBamy59 plasmid isolated from E. coli $DH5{\alpha}$ and B. longum MG1 by the cell extract of B. longum MG1 suggested that the main reason for its low transformation efficiency was related to the restriction modification (R-M) system. To confirm the correlation between the R-M system and transformation efficiency, in vitro methylation and site-directed mutagenesis were performed in pYBamy59. Sequence analysis of pYBamy59 fragments digested by the cell extract of B. longum MG1 revealed that all fragments were generated by restriction of the sequence recognized by SacII endonuclease. When pYBamy59 from E. coli was methylated in vitro by CpG or GpC methyltransferase, it was protected from SacII digestion. Site-directed mutagenesis, which removed SacII sites from pYBamy59, or in vitro methylation of pYBamy59 showed 8- to 15-fold increases in the transformation efficiency over intact pYBamy59. Modification of the SacII-related R-M system in B. longum MG1 and in vitro methylation in pYBamy 59 can improve the transformation efficiency in this strain. The results showed that the R-M system is a factor to limit introduction of exogenous DNA, and in vitro modification is a convenient method to overcome the barrier of the R-M system for transformation.

Study on The System Suitability Test for Alcohols Separation by GCOTC (GCOTC에 의한 알코올류 분리를 위한 시스템 적합성에 관한 연구)

  • Oh, Doe Seok;Kim, Sung Hwa;Lee, Seul;Choi, Jae Gu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • 제27권2호
    • /
    • pp.123-129
    • /
    • 2017
  • Objectives: The purpose of this study is to enhance the application of analytical method of polar solvents(alcohols) by GCOTC (gas chromatography open tubular column) through the system suitability test(SST) to estimate the whole chromatographic system performance(integral part). Methods: To perform the SST, carried out repeatability(n=6) as analytical method of polar solvents by GCOTC, got the retention time($t_R$), standard deviation(${\sigma}_{n-1}$) of $t_R$, baseline width($w_b=4{\sigma}_{n-1}$) and calculated dead time($t_m$) by $v_m=d^2{\pi}L(f/4)$ and $v_m=t_m$ x flow rate. Results: In this experiment, obtained the basic data, there were $t_m=2$ min, methanol($t_R=3.569$, ${\sigma}_{n-1}=0.01$, $w_b=0.04$), ethanol ($t_R=3.892$, ${\sigma}_{n-1}=0.004$, $w_b=0.016$), isopropanol($t_R=4.209$, ${\sigma}_{n-1}=0.004$, $w_b=0.016$). By using these data, calculated the corrected retention time($t_R{^{\prime}}$), capacity factor(k), separation factor(${\alpha}$), number of theoretical plate(n) and resolution($R_s$) for SST and got the good results. Conclusions: Through the SST, could reconfirm the whole chromatographic performance system(integral part) for analytical method of polar solvents by GCOTC. Therefore, this analytical method expect to be widely applied at the related areas.

Development of the Automatic Hauling Operation System by Three boats for Anchovy Boat Seine (기선권현망어업의 3척식 자동화 양망시스템 개발)

  • An, Young-Su;Jang, Choong-Sik;Lee, Myeong-Kyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • 제41권2호
    • /
    • pp.147-155
    • /
    • 2005
  • This study was conducted in order to improve the automatic fishing operation system for anchovy boat seine by comparison with the fishing gear geometry and efficiency using the labor saving nets and the combined type net with midwater trawl. Field experiments were carried out to observe the geometry of nets and improve the fishing operation system by catcher boats. The vertical net opening of fore wing net, square, fore bag net and after bag net of the combined type net were varied in the range of 9.9~12.9. 16.2~28.2, 6.8~12.1 and 9.5~15.2m respectively, when the towing speed was 1.0m/sec and the distance between boats were 100m, 200m, 300m. The vertical net opening of the combined type nets was gradually decreased as function of with increasing the distance between catcher boats. Labor saving net which was maintained the net opening and towing depth stable was more suitable for the automatic hauling operation system by improvement of bag net rather than the combined type nets which was impossible in swallow depth and near to anchovy school. 3 boats hauling operation system of the labor saving net was carried out by crane with power block in 2 catcher boats for improvement of hauling operation and pushing equipment of anchovy cooking system in the processing boat for maintain more anchovy in dry frame. From the results of field experiments, 3 boats hauling operation system with power block and improved cooking system was very 3 boats hauling operation system with power block and improved cooking system was very useful and more practical as hauling time 20~35min and No. of fishermen 12~13 in comparison with the traditional system such as hauling time 30~50 min and No. of fishmen 28~38.

Operational characteristics analysis of a 8 mH class HTS DC reactor for an LCC type HVDC system

  • Kim, S.K.;Go, B.S.;Dinh, M.C.;Kim, J.H.;Park, M.;Yu, I.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • 제17권1호
    • /
    • pp.32-35
    • /
    • 2015
  • Many kinds of high temperature superconducting (HTS) devices are being developed due to its several advantages. In particular, the advantages of HTS devices are maximized under the DC condition. A line commutated converter (LCC) type high voltage direct current (HVDC) transmission system requires large capacity of DC reactors to protect the converters from faults. However, conventional DC reactor made of copper causes a lot of electrical losses. Thus, it is being attempted to apply the HTS DC reactor to an HVDC transmission system. The authors have developed a 8 mH class HTS DC reactor and a model-sized LCC type HVDC system. The HTS DC reactor was operated to analyze its operational characteristics in connection with the HVDC system. The voltage at both ends of the HTS DC reactor was measured to investigate the stability of the reactor. The voltages and currents at the AC and DC side of the system were measured to confirm the influence of the HTS DC reactor on the system. Two 5 mH copper DC reactors were connected to the HVDC system and investigated to compare the operational characteristics. In this paper, the operational characteristics of the HVDC system with the HTS DC reactor according to firing angle are described. The voltage and current characteristics of the system according to the types of DC reactors and harmonic characteristics are analyzed. Through the results, the applicability of an HTS DC reactor in an HVDC system is confirmed.

Improvement of Accuracy on Dynamic Position Determination Using Combined DGPS/IMU (DGPS/IMU 결합에 의한 동적위치결정의 정확도 향상)

  • Back, Ki-Suk;Park, Un-Yong;Hong, Soon-Heon
    • Journal of the Korean Geophysical Society
    • /
    • 제9권4호
    • /
    • pp.361-369
    • /
    • 2006
  • This study conducted an initialization test to decide dynamic position using AHRS IMU sensor, and derived attitude correction angles of vehicles against time through regression analysis. It was also found that the heading angle was stabilized with variation less than 1°after 60 seconds. Using these angles, this study carried out an experiment on the determination of dynamic position for each system in the open sky and in a semi-open sky. According to the results, in the open sky, DGPS alone systems were excellent in accuracy but poor in data acquisition, so the moving distance was around 12m. In DGPS/IMU combined system, accuracy and data acquisition were satisfactory and the moving distance was around 0.3m. In a semi-open sky, DGPS alone systems were excellent in accuracy in order of DGPS < FIMU < DGPS/IMU according to average and standard errors obtained with exclusion of places where data were not be obtained. The moving distance was the same as that in the open sky. For DGPS, when places where data were not obtainable were divided into Several block and they were compared, the maximum deviation from the trajectory was up to 41.5m in DGPS alone system, but it was less than 2.2m and average and standard errors were significantly improved in the combined system. When the navigation system was applied to surveys and the result was compared with position error 0.2mm under the guideline for digital map, it was possible to work on maps on a scale of up to 1 : 1,000.

  • PDF

Pulsed Ferrite Magnetic Field Generator for Through-the-earth Communication Systems for Disaster Situation in Mines

  • Bae, Seok;Hong, Yang-Ki;Lee, Jaejin;Park, Jihoon;Jalli, Jeevan;Abo, Gavin S.;Kwon, Hyuck M.;Jayasooriya, Chandana K.K.
    • Journal of Magnetics
    • /
    • 제18권1호
    • /
    • pp.43-49
    • /
    • 2013
  • A pulsed ferrite magnetic field generator (FMFG) was designed for the use in the 1000 m long through-the-earth (TTE) communication system for mining disaster situations. To miniaturize the TTE system, a ferrite core having 10,000 of permeability was used for the FMFG. Attenuation of the magnetic field intensity from the FMFG (200-turn and 0.18 m diameter) was calculated to be 89.95 dB at 1000 m depth soil having 0.1 S/m of conductivity. This attenuation was lower than 151.13 dB attenuation of 1 kHz electromagnetic wave at the same conditions. Therefore, the magnetic-field was found to be desirable as a signal carrier source for TTE communications as compared to the electromagnetic wave. The designed FMFG generates the magnetic field intensity of $1{\times}10^{-10}$ Tesla at 1000 m depth. This magnetic field is detectable by compact magnetic sensors such as flux gate or magnetic tunneling junction sensor. Therefore, the miniature FMFG TTE communication system can replace the conventional electromagnetic wave carrier type TTE system and allow reliable signal transmission between rescuer and trapped miners.

Evaluation of Lethality by Chemical Marker (Chemical Marker를 이용한 살균도 예측)

  • Choi, Yang-Mun;Kim, Hie-Joon
    • Korean Journal of Food Science and Technology
    • /
    • 제29권1호
    • /
    • pp.32-37
    • /
    • 1997
  • The rate constants and activation energies for formation of two chemical markers, M-1 and M-2 at sterilization temperatures were determined in a meatball system. Destruction rates for bacterial spores were also determined. The rate constants for M-1 and M-2 formation at $121^{\circ}C$ were 0.03 and 0.28 Abs/min, respectively. The activation energies for M-1 and M-2 were 27.9 and 24.6 Cal/mol. M-2 was formed faster than M-1 and reached a maximum and decreased. M-1 formation continued up to 30 min at $121^{\circ}C$ and 10 min at $131^{\circ}C$, which makes M-1 a more useful chemical marker for high $F_0$ values. The D-values for spores (B. stearothermophilus ATCC 12980) at 111, 114.4, 117.7 and $121^{\circ}C$ were 7.5, 4.5, 1.9 and 0.58 respectively. At temperatures between 111 and $121^{\circ}C$, there was a liner correlation between destruction of the spores and the M-1 formation. It was difficult to get accurate D-value at $126^{\circ}C\;and\;131^{\circ}C$, because almost all spores were dead before temperature at the center of the meatball reached $126^{\circ}C$. These data suggest that the chemical marker should be used to evaluate overprocessing as well as microbial lethality in aseptic processing.

  • PDF