• Title/Summary/Keyword: m_1)-system$

Search Result 13,976, Processing Time 0.043 seconds

LINER STABILITY OF A PERIODIC ORBIT OF TWO-BALL LINEAR SYSTEMS

  • Chi, Dong-Pyo;Seo, Sun-Bok
    • Journal of the Korean Mathematical Society
    • /
    • v.36 no.2
    • /
    • pp.403-419
    • /
    • 1999
  • We introduce a Hamiltonian system which consists of two balls in the vertical line colliding elastically with each other and the floor. Wojtkowski proved that for the system of two linear balls with a linear potential (with gravity), there is a periodic orbit which becomes linearly stable if m1

  • PDF

Electricity Generation Using Cyanobacteria Synechocystis PCC 6803 in Photosynthetic Bio-Electrochemical Fuel Cell (남조류 Synechocystis PCC 6803을 이용한 생물전기화학적 물분해 전기 생산)

  • Kim, Min-Jin;Oh, You-Kwan;Kim, Mi-Sun
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.6
    • /
    • pp.529-536
    • /
    • 2008
  • Cyanobacteria Synechocystis PCC 6803 or the extracted thylakoid membrane from this strain was appled to photosynthetic bio-electrochemical fuel cell(PBEFC) for the production of hydrogen under the illumination of 48Klux using halogen lamp. PBEFC was composed of anode, cathode and membrane between them. Electrode material was carbon paper while electron mediator and receptor were added phenazine methosulfate(PMS) and potassium ferricyanide respectively. When water and 50 mM tricine buffer and $300{\mu}M$ PMS were added to the anode under the light condition, PBEFC produced the current density $4.4{\times}10^{-5}\;mA/cm^2$, $1.4{\times}10^{-4}\;mA/cm^2$ and $2.4{\times}10^{-4}\;mA/cm^2$, respectively. And the addition of the thylakoid membrane to the system increased current density to $1.3{\times}10^{-3}\;mA/cm^2$. Two times increase of the thylakoid membrane into the anode doubled the current density to $2.6{\times}10^{-3}\;mA/cm^2$. But the current density was not increased proportionally to the amount of thylakoid membrane increased. The system was unstable to measure the electricity output due to the foam production in the anode. Addition of triton X-100 and tween 80 stabilized the system to measure the electricity output but the current density was not increased higher than $8.4{\times}10^{-4}\;mA/cm^2$ and $2.3{\times}10^{-3}\;mA/cm^2$. When the thylakoid membrane was substituted to Synechocystis PCC 6803 cells of four-day culture which has chlorophyll contents $20.5{\mu}g/m{\ell}$, maximum current density was $1.3{\times}10^{-3}\;mA/cm^2$ with $1\;k{\Omega}$ resistance.

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

THE ${M_1},{M_/2}/G/l/K$ RETRIAL QUEUEING SYSTEMS WITH PRIORITY

  • Choi, Bong-Dae;Zhu, Dong-Bi
    • Journal of the Korean Mathematical Society
    • /
    • v.35 no.3
    • /
    • pp.691-712
    • /
    • 1998
  • We consider an M$_1$, M$_2$/G/1/ K retrial queueing system with a finite priority queue for type I calls and infinite retrial group for type II calls where blocked type I calls may join the retrial group. These models, for example, can be applied to cellular mobile communication system where handoff calls have higher priority than originating calls. In this paper we apply the supplementary variable method where supplementary variable is the elapsed service time of the call in service. We find the joint generating function of the numbers of calls in the priority queue and the retrial group in closed form and give some performance measures of the system.

  • PDF

Application of X-Y Dissociation of Mice as the in vivo Assaying System for Environmental Mutagens (Mouse 제 1정모세포에서의 X-Y 염색체 조기 분리;in vivo 환경성 변이원 검출계로서의 응용 가능성)

  • 최영현;권용원;최병태;조운복;이원호
    • Toxicological Research
    • /
    • v.11 no.1
    • /
    • pp.51-55
    • /
    • 1995
  • The present experiment was carried out to investigate whether X and Y chromosome dissociation in the primary spermatocytes of mice can be used as an in vivo assaying system that detect environmental mutagens. For this purpose, alkylating agents (EMS, MMS and MMC), which are strong mutagens, were administered to ICR male mice 12-15 weeks old. The mean frequencies of previously dissociated X-Y chromosomes and autosomes of the control group were 7.34-7.45% and 0.92-1.04%, respectively. The frequencies of X-Y dissociation in the mutagen-treated groups with 10.0 mM EMS and 5.0 mM MMS were about 3.3-4.6 times higher than that in the control group, but there were no significant differences in dissociation of autosomes in both the control and the mutagen-treated groups. These results suggest that X-Y dissociation in the primary spermatocytes of mice can be used as an in vivo short-term assaying system for environmental mutagens.

  • PDF

Measurements of Temperature and Flow Fields with Sub-Millimeter Spatial Resolution Using Two-Color Laser Induced Fluorescence (LIF) and Micro-Particle Image Velocimetry (PIV)

  • Kim Hyun Jung
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.716-727
    • /
    • 2005
  • Comprehensive measurements for velocity and temperature fields have been conducted. A Micro PIV 2-color LIF system have been setup to measure the buoyancy driven fields in a 1-mm heated channel with low Grashof-Prandtl numbers [$86]. Fluorescence microscopy is combined with an MPIV system to obtain enough intensity images and clear pictures from nano-scale fluorescence particles. The spatial resolution of the Micro PIV system is $75{\mu}m\;by\;67{\mu}m$ and error due to Brownian motion is estimated $1.05\%$. Temperature measurements have achieved the $4.7\;{\mu}m$ spatial resolution with relatively large data uncertainties the present experiment. The measurement uncertainties have been decreased down to less than ${\pm}1.0^{\circ}C$ when measurement resolution is equivalent to $76\;{\mu}m$. Measured velocity and temperature fields will be compared with numerical results to examine the feasibility of development as a diagnostic technique.

Comparison of the Nitrification Efficiencies of Three Biofilter Media in a Freshwater System

  • Harwanto, Dicky;Oh, Sung-Yong;Jo, Jae-Yoon
    • Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.363-369
    • /
    • 2011
  • Total ammonia nitrogen (TAN) removal efficiencies of a sand filter (SF), polystyrene microbead filter (PF), and Kaldnes bead filter (KF) media were evaluated under ammonia loading rates of 5, 25, and 50 g $m^{-3}day^{-1}$. The volume of each filter media tested was 7 L, and the water flow rate for all filter media was 24 L/min. The specific surface areas of the SF, PF, and KF were 7,836, 3,287, and 500 $m^2/m^3$, respectively. Sand was fluidized and the other two media were trickle filtered. The volumetric TAN removal rate increased with increasing ammonia loading rate for all filter media. Mean volumetric TAN removal rates under the ammonia loading rates of 5, 25, and 50 g $m^{-3}day^{-1}$ in SF (39.3, 168.6, and 322.7 g $m^{-3}day^{-1}$, respectively) were higher than those in PF (35.0, 157.4, and 310.5 g $m^{-3}day^{-1}$, respectively) and KF (32.1, 142.5, and 288.1 g $m^{-3}day^{-1}$, respectively). These results were related to differences in the specific surface areas of the filter media. PF was the most economic media for efficiently removing TAN.

A STUDY ON THE IMPROVEMENT OF NEAR-REAL TIME GPS PHASE DATA PROCESSING ALGORITHM (준실시각 GPS 위상자료 처리 알고리즘 성능 개선에 관한 연구)

  • 손동효;조정호;박종욱;임형철;박필호;최규홍
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.2
    • /
    • pp.129-140
    • /
    • 2004
  • KAO(Korea Astronomy Observatory) GPS group has developed an iRTK system as a near-real time positioning system using GPS carrier phase data. We focused on improving the accuracy of positioning through the updated capability of data processing of KAO's iRTK system using low-cost L1 carrier phase receiver. The accuracy of a positioning was demonstrated by Extended Kalman filter. Experiments were accomplished using from 30m to 20km baselines. Within 10km, the positioning accuracy was improved by approximately 50-70% to the previous study using one minute observable data. However, it took two minutes to obtain 1m level positioning accuracy at 20km point. We expect that the developed iRTK system can be applied to the various fields of GPS in near-real time positioning.

An ESR Study of Amino Acid and Protein Free Radicals in Solution Part VI. Enzymatic Inactivation of Lysozyme in Aqueous Solution Resulting from Exposure to $Ti-H_2O_2$ System and Gamma-Irradiation

  • Hong, Sun-Joo;Piette, L.H.
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.2
    • /
    • pp.80-83
    • /
    • 1972
  • The activity change of lysozyme resulted from its exposure to $Ti-H_2O_2$system in aqueous liquid at room temperature and to ${\gamma}$-irradiation in ice at $195^{\circ}K$ has been measured at room temperature with a Cary-14 spectrophotometer. The enzymatic activity of lysozyme which had been added to a previously flow-mixed solution of $TiCl_3$ and $H_2O_2$ (System I) was compared with the activity of a lysozyme-$H_2O_2$ solution after flow-mixing with $TiCl_3$ (System II), considering the differences between these two activity changes as the extent of the enzymatic inactivation by the involvement of OH radical reaction. The fraction of lysozyme inactivated by OH radical in the system containing 0.0025 M $TiCl_3-0.1M$ $H_2O_2$ (ph 3.5) was 13%, When the $TiCl_3$ concentration is double (pH 3.0), the fraction of enzyme inactivated increases to 36%. The activity of the system containing 0.025 M $TiCl_3-0.1$ M $H_2O_2$ (pH 1.5) was essentially zero. The results seem to support the previos view that the production of OH radical should be proportional to $TiCl_3$ concentration when $H_2O_2$ is present in excess. Increase in the extent of inactivation found in system I with increasing $TiCl_3$ concentration may be due to a pH effect. $H_2O_2$ seems to be less effective than $TiCl_3$ in the inactivation. 1% lysozyme solution, when ${\gamma}$-irradiated with a total dose of 3M rads, loses about 20% of its activity. Lowering of temperature also was found to yield a reduction in enzymatic activity.

  • PDF

The Threshold Policy in the M/M/2 Queue with Server Vacation (휴가가 존재하는 M/M/2 대기 시스템의 한계치를 이용한 제어정책)

  • 이효성
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.20 no.2
    • /
    • pp.1-10
    • /
    • 1995
  • In this study, a threshold policy is considered for the M/M/2 queueing system with server vacations. The probability generating function for the number of customers present in the system is derived using an embedded Markov chain approach. Then, assuming a linear cost structure, an efficient procedure to find an optimal threshold policy is presented. The Laplace-Stieltjes transofrm for th waiting time of an arbitrary customer under a "FIFO" discipline is also derived.o derived.

  • PDF