• Title/Summary/Keyword: mDixon

Search Result 39, Processing Time 0.028 seconds

Comparison of mDixon, T2 TSE, and T2 SPIR Images in Magnetic Resonance Imaging of Lumbar Sagittal Plane (요추 시상면 자기공명 영상검사에서 mDixon과 T2 TSE, T2 SPIR 영상의 비교 연구)

  • Jung, Da-Bin;Lee, Hae-Kag;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.927-933
    • /
    • 2021
  • The purpose of this study was to compare and analyze the differences in scan time, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the third lumbar vertebral region including the back fat, spinal cord, and cerebrospinal fluid using the mDixon, T2 TSE, and T2 spectral pre-saturation with inversion-recovery (SPIR) techniques. With the factors affecting the SNR fixed, the lumbar sagittal plane images of 30 adults were compared on mDixon, T2 TSE, and T2 SPIR imaging tests. The test times for mDixon, T2 TSE, and T2 SPIR were 115 seconds, 60 seconds, and 60 seconds, respectively. The mDixon T2 images showed higher SNR than the T2 TSE images at the third lumbar vertebral region (p<0.05), lower SNR in the back fat and cerebrospinal fluid (p<0.05) areas, and comparable SNR in the spinal cord (p>0.05). The CNR between the third lumbar vertebral area and back fat was higher in the mDixon T2 images, and the CNR of the cerebrospinal fluid and spinal cord images was higher in the T2 TSE images (p<0.05). The mDixon T2 FS images CNR was lower for the 3rd lumbar vertebral body region and back fat than the T2 SPIR images, and higher for the spinal cord and cerebrospinal fluid images (p<0.05). The CNR between the third lumbar body and back fat areas was higher in the mDixon T2 FS images (p<0.05), and there was no difference in the CNR in the images of the cerebrospinal fluid and the spinal cord (p>0.05). It is difficult to determine whether the mDixon technique is superior to the conventional T2 TSE and T2 SPIR techniques in terms of test time, SNR, and CNR. This study was confined to patients with simple lower back pain and was limited by controlled experimental conditions. Studies using clinically applied protocols are warranted in the future.

Evaluation of Usefulness of an m-DIXON Technique during an Abdomen MRI Examination : A Comparison with an e-THRIVE Technique (복부 MRI검사에서 m-DIXON기법의 유용성 평가: e-THRIVE기법과 비교 분석)

  • Lee, Bo-Woo;Park, Myung-Cheol;Lee, Jin-Hoi;Kim, Ki-Jin;Bae, Seok-Hwan
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.385-390
    • /
    • 2014
  • This research is conducted to identify whether an m-DIXON technique which is useful for an abdomen MRI examination compared with an existing e-THRIVE technique is a clinically useful or not. There was evaluated quantitative and qualitative to 84 subjects who had abdomen MRI exam due to their liver disease were conducted during a period from September in 2013 to February in 2014. First of all the quantitative evaluation, the m-DIXON technique's SNR was $90.42{\pm}16.90$ and the e-THRIVE technique was $60.42{\pm}11.54$ and the m-DIXON technique's CNR was $52.38{\pm}22.58$ and the e-THRIVE technique was $46.31{\pm}20.25$. Secondly in the qualitative evaluation, the m-DIXON technique's image quality was $4.06{\pm}0.34$, a artifact was $3.64{\pm}0.22$, and fat suppression was $4.16{\pm}0.15$, the e-THRIVE technique's image quality was $3.14{\pm}0.35$, a artifact was $3.06{\pm}0.38$, fat suppression was $3.14{\pm}0.30$. In conclusion, m-DIXON technique for abdomen MRI examination showed superiority over both SNR as a quantitative anaylsis, CNR and a qualitative analysis.

Fat Quantification in the Vertebral Body: Comparison of Modified Dixon Technique with Single-Voxel Magnetic Resonance Spectroscopy

  • Sang Hyup Lee;Hye Jin Yoo;Seung-Man Yu;Sung Hwan Hong;Ja-Young Choi;Hee Dong Chae
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.126-133
    • /
    • 2019
  • Objective: To compare the lumbar vertebral bone marrow fat-signal fractions obtained from six-echo modified Dixon sequence (6-echo m-Dixon) with those from single-voxel magnetic resonance spectroscopy (MRS) in patients with low back pain. Materials and Methods: Vertebral bone marrow fat-signal fractions were quantified by 6-echo m-Dixon (repetition time [TR] = 7.2 ms, echo time (TE) = 1.21 ms, echo spacing = 1.1 ms, total imaging time = 50 seconds) and single-voxel MRS measurements in 25 targets (23 normal bone marrows, two focal lesions) from 24 patients. The point-resolved spectroscopy sequence was used for localized single-voxel MRS (TR = 3000 ms, TE = 35 ms, total scan time = 1 minute 42 seconds). A 2 × 2 × 1.5 cm3 voxel was placed within the normal L2 or L3 vertebral body, or other lesions including a compression fracture or metastasis. The bone marrow fat spectrum was characterized on the basis of the magnitude of measurable fat peaks and a priori knowledge of the chemical structure of triglycerides. The imaging-based fat-signal fraction results were then compared to the MRS-based results. Results: There was a strong correlation between m-Dixon and MRS-based fat-signal fractions (slope = 0.86, R2 = 0.88, p < 0.001). In Bland-Altman analysis, 92.0% (23/25) of the data points were within the limits of agreement. Bland-Altman plots revealed a slight but systematic error in the m-Dixon based fat-signal fraction, which showed a prevailing overestimation of small fat-signal fractions (< 20%) and underestimation of high fat-signal fractions (> 20%). Conclusion: Given its excellent agreement with single-voxel-MRS, 6-echo m-Dixon can be used for visual and quantitative evaluation of vertebral bone marrow fat in daily practice.

A GENERALIZATION OF PREECE`S IDENTITY

  • Kim, Yong-Sup;Arjun K.Rathie
    • Communications of the Korean Mathematical Society
    • /
    • v.14 no.1
    • /
    • pp.217-222
    • /
    • 1999
  • The aim of this research is to provide a generalization of the well-known, interesting and useful identity due to Preece by using classical Dixon`s theorem on a sum of \ulcornerF\ulcorner.

  • PDF

Detecting Peripheral Nerves in the Elbow using Three-Dimensional Diffusion-Weighted PSIF Sequences: a Feasibility Pilot Study

  • Na, Domin;Ryu, Jaeil;Hong, Suk-Joo;Hong, Sun Hwa;Yoon, Min A;Ahn, Kyung-Sik;Kang, Chang Ho;Kim, Baek Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.81-87
    • /
    • 2016
  • Purpose: To analyze the feasibility of three-dimensional (3D) diffusion-weighted (DW) PSIF (reversed FISP [fast imaging with steady-state free precession]) sequence in order to evaluate peripheral nerves in the elbow. Materials and Methods: Ten normal, asymptomatic volunteers were enrolled (6 men, 4 women, mean age 27.9 years). The following sequences of magnetic resonance images (MRI) of the elbow were obtained using a 3.0-T machine: 3D DW PSIF, 3D T2 SPACE (sampling perfection with application optimized contrasts using different flip angle evolution) with SPAIR (spectral adiabatic inversion recovery) and 2D T2 TSE (turbo spin echo) with modified Dixon (m-Dixon) sequence. Two observers used a 5-point grading system to analyze the image quality of the ulnar, median, and radial nerves. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of each nerve were measured. We compared 3D DW PSIF images with other sequences using the Wilcoxon-signed rank test and Friedman test. Inter-observer agreement was measured using intraclass correlation coefficient (ICC) analysis. Results: The mean 5-point scores of radial, median, and ulnar nerves in 3D DW PSIF (3.9/4.2/4.5, respectively) were higher than those in 3D T2 SPACE SPAIR (1.9/2.8/2.8) and 2D T2 TSE m-Dixon (1.7/2.8/2.9) sequences (P < 0.05). The mean SNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR, but there was no difference between 3D DW PSIF and 2D T2 TSE m-Dixon in all of the three nerves. The mean CNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR and 2D T2 TSE m-Dixon in the median and ulnar nerves, but no difference among the three sequences in the radial nerve. Conclusion: The three-dimensional DW PSIF sequence may be feasible to evaluate the peripheral nerves around the elbow in MR imaging. However, further optimization of the image quality (SNR, CNR) is required.

MR Lymphangiography (자기공명영상 림프관조영술)

  • Sang Hoon Lee;Joon Pio Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.70-80
    • /
    • 2020
  • Currently, there has been an increase in the use of surgical modalities to treat lymphedema and MR imaging to examine lymphatic vessels. Furthermore, there have been several advancements in the field of MR imaging, from the traditional heavily T2-weighted images to three-dimensional images. Three-dimensional images include spoiled gradient echo images, and numerous advanced techniques have been implemented. Among the fat suppression techniques, mDixon technique has recently been in the spotlight.

Correlation Between Vertebral Marrow Fat Fraction Measured Using Dixon Quantitative Chemical Shift MRI and BMD Value on Dual-energy X-ray Absorptiometry (Dixon 정량 화학적 변위 자기공명영상을 이용한 척추 골수 지방함량과 이중에너지 방사선 흡수법의 BMD 값의 비교)

  • Youn, In-Young;Lee, Hwa-Yeon;Kim, Jae-Kyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.16-24
    • /
    • 2012
  • Purpose : The purpose of this study was to determine whether there is a significant correlation between vertebral marrow fat fraction measured using Dixon quantitative chemical shift MRI (QCSI) and BMD on dual-energy X-ray absorptiometry (DXA). Materials and Methods: This retrospective study included 68 healthy individuals [mean age, 50.7 years; range, 25-76; male/female (M/F) = 36/32] who underwent DXA of the L-spine and whole body MRI including QCSI of the L-spine and chemical shift MRI of the liver. The enrolled individuals were divided into subgroups according to sex and T-score [i.e., normal bone density (M/F=27/23) and osteopenia (M/F=9/9)]. Vertebral marrow (Dixon QCSI, TR/TE 10.2/4.8 ms) and hepatic fat fractions (chemical shift technique, TR/TE 110/4.9 and 2.2 ms) were calculated on MRI. We evaluated whether there were significant differences in age, body mass index (BMI), vertebral marrow fat fraction, or hepatic fat fraction among the subgroups. Whether or not the participant had reached menopause was also evaluated in females. The correlations among variables (i.e., age, BMI, vertebral marrow and hepatic fat fractions, BMD) were evaluated using Spearman's correlation method. Results: There were no significant differences in age, BMI, or vertebral marrow and hepatic fat fractions between the two male subgroups (normal bone density vs. osteopenia). In female subjects, mean age in the osteopenic subgroup was greater than that in the normal subgroup (p=0.01). Presence of menopause was more common in the osteopenic subgroup [77.8% (7/9)] than the normal subgroup [26.1% (6/23), p<0.05]. The other variables showed no significant difference between female subgroups. The only significant correlation with marrow fat fraction after partial correlation analysis was that with age in the female subjects (r=0.43, p<0.05). Conclusion: The vertebral marrow fat fraction calculated using the Dixon QCSI does not precisely reflect the mild decrease in BMD for either sex.

Comparative Analysis on the Outlier Data of Each Parameter in Automatic Water Quality Monitoring Networks (수질자동측정망 자료의 항목별 이상치 비교 분석)

  • Lim, Byungjin;Hong, Eunyoung;Yeon, Insung
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.4
    • /
    • pp.700-706
    • /
    • 2010
  • Along the 4 major rivers in korea, there are automatic water quality monitoring (AWQM) stations to immediately respond to any pollution incident. Real-time data (temperature, DO, pH, EC and TOC) collected at each station were statistically treated to exclude outliers and keep valid data using Dixon's test and Discordance test. These applied methods were compared in terms of the number of the outliers sorted out. There was no significant difference between these methods. On the other hand, more outliers were sorted out from EC and TOC data, comparing with other water quality items. EC data did not show partly any variation for a long time at H station. If measured signal does not exceed ${\pm}0.001mS/cm$ from the sectional mean, the signal should be treated as normal data. Therefore, another routine was added to the data screening system, some data which were removed as outlier were restored.