• Title/Summary/Keyword: m-point

Search Result 5,525, Processing Time 0.041 seconds

The Effects of a MR Torso Coil on CT Attenuation Correction for PET (PET/CT 검사에 있어서 MR Torso Coil의 CT 감쇄보정에 대한 영향 평가)

  • Lee, Seung Jae;Bahn, Young Kag;Oh, Shin Hyun;Gang, Cheon-Gu;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho;Seo, Soo-Hyun;Park, Yong Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.81-86
    • /
    • 2012
  • Purpose : Combined MR/PET scanners that use the MRI for PET AC face the challenge of absent surface coils in MR images and thus cannot directly account for attenuation in the coils. To make up for the weak point of MR attenuation correction, Three Modality System (PET/CT +MR) were used in Severance hospital. The goal of this work was to investigate the effects of MR Torso Coil on CT attenuation correction for PET. Materials and Methods : PET artifacts were evaluated when the MR Torso Coil was present of CTAC data with changing various kV and mA in uniformity water phantom and 1994 NEMA cylinderical phantom. They evaluated and compared the following two scenarios: (1) The uniform cylinder phantom and the MR Torso Coil scanned and reconstructed using CT-AC; (2) 1994 NEMA cylinderical phantom and the MR Torso Coil scanned and reconstructed using CT-AC. Results : Streak artifacts were present in CT images containing the MR Torso Coil due to metal components. These artifacts persisted after the CT images were converted for PET-AC. CT scans tended to over-estimate the linear attenuation coefficient when the kV and mA is increasing of the metal components when using conventional methods for converting from CT number. Conclusion : The presence of MR coils during PET/CT scanning can cause subtle artifacts and potentially important quantification errors. Alternative CT techniques that mitigate artifacts should be used to improve AC accuracy. When possible, removing segments of an MR coil prior to the PET/CT exam is recommended. Further, MR coils could be redesigned to reduce artifacts by rearranging placement of the most attenuating materials.

  • PDF

Influence of Temperature on the Egg Production and Hatching of Microcotyle sebastis (Monogenea : Microcotylidae), Parasitic on Rockfish, Sebastes schlegeli (수온이 조피볼락에 기생하는 아가미흡충(Microcotyle sebastis)의 산란과 부화에 미치는 영향)

  • Kim, Ki-Hong;Choi, Eun-Seok;Cho, Jae-Bum;Hwang, Yoon-Jung;Park, Soo-Il
    • Journal of fish pathology
    • /
    • v.11 no.2
    • /
    • pp.113-117
    • /
    • 1998
  • The influence of temperature on the rate of egg production and embryonic development of Microcotyle sebastis was investigated to determine the precise time of a second treatment. The survival time of the adults of M. sebastis was inversely proportional to temperature. The number of laid eggs per each replicate during the first 24 h was $39.3{\pm}4.0$ at $10^{\circ}C$, $62.7{\pm}14.2$ at $15^{\circ}C$, $101.0{\pm}5.6$ at $20^{\circ}C$ and $89.0{\pm}11.0$ at $25^{\circ}C$. The time required for egg hatching of M. sebastis was $31.30{\pm}4.88$, $17.52{\pm}3.24$, $11.59{\pm}3.02$ and $10.76{\pm}3.10$ days at 10, 15, 20 and $25^{\circ}C$, respectively. The regression models of the time required for the beginning and 50% point of hatching according to the different temperatures were as follows; Beginning of hatch: D=58.2000-$4.2067{\times}Temp+0.0867{\times}(Temp)^2$ ($P\leq0.01$), 50% of hatch: D=91.3833-$7.5767{\times}Temp+0.1767{\times}(Temp)^2$ ($P\leq0.01$).

  • PDF

Establishing Process of the 1st 10-year National Greening Project : At the Turning Point between the Management-oriented Approach and Administration-oriented Approach (제1차 치산녹화10년계획의 수립 과정:경영중심 임정과 행정중심 임정의 갈림길)

  • Bae, Jae-Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.3
    • /
    • pp.269-282
    • /
    • 2007
  • The purpose of this study is to investigate the causes of the dramatic process in forest policies from July of 1972 to June of 1973. In 1972, the core forest problem calling for an immediate solution was the severe forest degradation such as a low growing stock ($11m^3/ha$) and lots of non-tree forest land corresponding to 12% of total forest land. There could have been various approaches to solve the problem at that time. By the end of 1972, the Korean government was afoot to choose the management-oriented approach to carry out reforestation as a part of forest management. In order to implement this approach, the Korean government established the Forest Development Law enforcing establishment of the Forest Management Corporation as a public organization to carry out forest management in the special development land. However, the Korean government changed the management-oriented approach into the administration-oriented approach to carry out reforestation as a part of forest greening in order to rehabilitate severe degraded forests as soon as possible in early 1973. The Forestry Administration (refer to Forest Service) was transferred from the Department of Agriculture and Forestry to the Department of Interior for the efficient rehabilitation in advance, before the 1st 10-year National Greening Project. After the organization's transfer, the government established the 1 st 10-year National Greening Project aiming to reforest one million ha from 1973 to 1982 to use activities like the national greening campaign and the administrative organization mobilization including police force. Reforestation policy as a part of forest management lost effect due to the greening-oriented approach choice. Moreover, the Government struggled to provide 20 billion won for the establishment of the Forest Management Corporation. After all, on March 5th of 1973, the management-oriented approach dropped a curtain deleting the clauses defining the establishment of the Forest Management Corporation. Park, Chung-hee who was the then president of Korea might have felt the 'time restriction' to lose no time to habilitate degraded forests. Due to his awareness, the approach regarding reforestation was changed into administration-oriented activities. The president's awareness was considered as an invisible cause at that time.

Changes in Transpiration Rates and Growth of Cucumber and Tomato Scions and Rootstocks Grown Under Different Light Intensity Conditions in a Closed Transplant Production System (식물공장형육묘시스템 내 광량에 따른 오이와 토마토 접수 및 대목의 증발산량 및 생육 변화)

  • Park, Seon Woo;An, Sewoong;Kwack, Yurina
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.399-405
    • /
    • 2020
  • Recently, it is difficult to produce uniform scions and rootstocks with high quality in a greenhouse due to weather extremes. The closed transplant production system is useful for producing scions and rootstocks with desirable morphological characteristics by environment control regardless of weather outside. In this study, we investigated transpiration rates and growth of cucumber and tomato scions and rootstocks grown under different light intensity conditions for precise irrigation control in a closed transplant production system. Hanging system to measure continuously the weight of plug tray consisting of seedlings and substrate with load-cell was installed in each growing bed. Using this system, we confirmed initial wilting point of cucumber and tomato seedlings, and conducted subirrigation when moisture content of substrate was not below 50%. The irrigation time of cucumber scions and rootstocks were 7 and 6 days after sowing, respectively. In tomato scions and rootstocks grown under PPF (photosynthetic photon flux) 300 μmol·m-2·s-1, the irrigation time were 5, 8, 11, and 13 days after sowing. Increasing light intensity increased transpiration rates and differences of transpiration rates by light intensity was higher in tomato seedlings. The growth of cucumber and tomato seedlings was promoted by increasing light intensity, especially, hypocotyl elongation and stem thickening was affected by light intensity. Cumulative transpiration rate of plug tray in cucumber and tomato seedlings was increased by increasing light intensity, and daily transpiration rate per seedling was regressed by 1st-order linear equation with high correlation coefficient. Estimation of transpiration rates by weighing continuously plug tray of vegetable seedlings can be useful to control more accurately irrigation schedule in a closed transplant production system.

A Low-Dose High-Resolution SPECT System with CdTe for Small-Animal Imaging Applications: A GATE Simulation Study (GATE 시뮬레이션을 통한 고해상도 저선량용 소동물 영상화를 위한 CdTe 검출기 기반의 SPECT 기기 연구)

  • Park, Su-Jin;Yu, A Ram;Kim, Yeseul;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.162-170
    • /
    • 2013
  • Dedicated single-photon emission computed tomography (SPECT) systems based on pixelated semiconductors are being developed for studying small animal models of human disease. To clarify the possibility of using a SPECT system with CdTe for a high resolution low-dose small animal imaging, we compared the quality of reconstructed images from pixelated CdTe detector to those from a small SPECT system with NaI(Tl). The CdTe detector was $44.8{\times}44.8$ mm and the pixels were $0.35{\times}0.35{\times}5$ mm. The intrinsic resolution of the detector was 0.35 mm, which is equal to the pixel size. GATE simulations were performed to assess the image quality of both SPECT systems. The spatial resolutions and sensitivities for both systems were evaluated using a 10 MBq $^{99m}Tc$ point source. The quantitative comparison with different injected dose was performed using a voxelized MOBY phantom, and the absorbed doses for each organ were evaluated. The spatial resolution of the SPECT with NaI(Tl) was about 1.54 mm FWHM, while that of the SPECT with a CdTe detector was about 1.32 mm FWHM at 30 mm. The sensitivity of NaI(Tl) based SPECT was 83 cps/MBq, while that of the CdTe detector based SPECT was 116 cps/MBq at 30 mm. The image statistics were evaluated by calculating the CNR of the image from both systems. When the injected activity for the striatum in the mouse brain was 160 Bq/voxel, the CNR of CdTe based SPECT was 2.30 while that of NaI(Tl) based SPECT was 1.85. The CNR of SPECT with CdTe was overall higher than that of the NaI(Tl) based SPECT. In addition, the absorbed dose was higher from SPECT with CdTe than those from NaI(Tl) based SPECT to acquire the same quantitative values. Our simulation results indicated that the SPECT with CdTe detector showed overall high performance compared to the SPECT with NaI(Tl). Even though the validation study is needed, the SPECT system with CdTe detector appeared to be feasible for high resolution low-dose small animal imaging.

Development of Automated Region of Interest for the Evaluation of Renal Scintigraphy : Study on the Inter-operator Variability (신장 핵의학 영상의 정량적 분석을 위한 관심영역 자동설정 기능 개발 및 사용자별 분석결과의 변화도 감소효과 분석)

  • 이형구;송주영;서태석;최보영;신경섭
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.41-50
    • /
    • 2001
  • The quantification analysis of renal scintigraphy is strongly affected by the location, shape and size of region of interest(ROI). When ROIs are drawn manually, these ROIs are not reproducible due to the operators' subjective point of view, and may lead to inconsistent results even if the same data were analyzed. In this study, the effect of the ROI variation on the analysis of renal scintigraphy when the ROIs are drawn manually was investigated, and in order to obtain more consistent results, methods for automated ROI definition were developed and the results from the application of the developed methods were analyzed. Relative renal function, glomerular filtration rate and mean transit time were selected as clinical parameters for the analysis of the effect of ROI and the analysis tools were designed with the programming language of IDL5.2. To obtain renal scintigraphy, $^{99m}$Tc-DTPA was injected to the 11 adults of normal condition and to study the inter-operator variability, 9 researchers executed the analyses. The calculation of threshold using the gradient value of pixels and border tracing technique were used to define renal ROI and then the background ROI and aorta ROI were defined automatically considering anatomical information and pixel value. The automatic methods to define renal ROI were classified to 4 groups according to the exclusion of operator's subjectiveness. These automatic methods reduced the inter-operator variability remarkably in comparison with manual method and proved the effective tool to obtain reasonable and consistent results in analyzing the renal scintigraphy quantitatively.

  • PDF

Variation of Air Temperature Inside Carbonate Area Caves (석회암 지역에 분포하는 동굴의 내부 온도 변동 특성)

  • Kim, Lyoun;Park, Youngyun;Lee, Jonghee;Choi, Jaehun;Jung, Qyusung;Kim, Jungtae;Kim, Insu
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.1
    • /
    • pp.52-63
    • /
    • 2020
  • This study was conducted in order to evaluate the characteristics of air temperature fluctuation inside the Daegeumgul, Ondaldonggul, and Seongnyugul Caves, which are the most representative limestone caves in Korea, and also to assess the effects of air temperature on cave temperature. Temperature was measured hourly at three sites in Daegeumgul, Ondaldonggul, and Seongnyugul Caves from April 13 to June 25, 2019. Additionally, air temperature data for the areas around the caves was provided by the Meteorological Administration. Using this collected data, the basic statistical measure of fluctuation characteristics over time was ascertained, and time series analyses were performed. Wide variation of temperature was exhibited in the order of the cave entrance, the cave water inflow point, and the midpoint. Cave temperature was observed to increase gradually during the study period. There was a vast range in temperature at the Daegeumgul station located approximately 150 m outside the cave, but it remained nearly constant beyond the midpoint. Although the effect of air temperature was not significant due to the influence of visitors, the effect of air temperature on cave temperature gradually decreased from the entrance to the interior. At Ondaldonggul, there was a wide range in temperature recorded at the entrance due to the influence of air temperature, but it stayed almost constant in the interior. However, at the site where cave water flows into the cave, temperature was influenced by the cave water temperature. At Seongnyugul, there was a distinct fluctuation in temperature recorded at the cave entrance, while the middle of the cave remained nearly constant. Temperature fluctuated due to the air temperature at the entrance, while at the middle of the cave, measurements were expected to be affected to a greater extent by the lake water temperature than by the air temperature. However, this pattern was not observed. According to the time series analysis results, in all caves, fluctuations of air temperature affected cave temperature after approximately one hour. Cave size and structure, water presence, the entrance's size and shape, air flow, and visitor patterns can all influence cave temperature. Therefore, consideration of these factors is very important in the pursuit to clearly understand cave temperature characteristics.

Groundwater-Stream Water Interaction Induced by Water Curtain Cultivation Activity in Sangdae-ri Area of Cheongju, Korea (청주 상대리지역에서 수막재배가 지하수-하천수 상호작용에 미치는 영향)

  • Moon, Sang-Ho;Kim, Yongcheol;Jeong, Youn-Young;Hwang, Jeong
    • Economic and Environmental Geology
    • /
    • v.49 no.2
    • /
    • pp.105-120
    • /
    • 2016
  • Most of riverside in Korea, in case of application of water curtain cultivation (WCC) technique, has been inveterately suffering from the gradual drawdown of groundwater level and related shortage of water resources during the WCC peak time. We believe that the water resources issue in these riverside areas can be effectively solved when the interaction between groundwater and nearby surface water is well understood. To investigate the connection between stream and ground water, and the influence of stream water on the nearby aquifer, this study examined the water temperature and oxygen and hydrogen stable isotopic compositions. The study area is well-known strawberry field applying the WCC technique in Sangdae-ri, Gadeok-myon, Cheongju City, and the sampling was done from February 2012 through June 2014 for stream and ground water. Some groundwater wells near stream showed big temporal variations in water temperature, and their oxygen and hydrogen stable isotopes showed similar compositions to those of adjacent stream water. This indicates that the influence of stream water is highly reflected in the stable isotopic composition of groundwater. Four cross-sectional lines from stream to hillside were established in the study area to determine the spatial differences in water quality of wells. At the late stage of WCC in February to March, groundwater of wells in line with short cross-sectional length showed the narrow range of isotopic compositions; however, those in the long cross-sectional line showed a wide compositional range. It was shown that the influence of the stream water at the late WCC stage have reached to the distance of 160 to 165 m from stream line, which is equivalent to the whole length and one-third point in each short and long cross-sectional line, respectively. Therefore, the wide compositional range in the long cross-sectional lines was not only due to the influence of stream water, but apparently resulted from the change of relative impact of each groundwater supplying from two or more aquifers. In view of stable isotopic compositions, there seems to be three different aquifers in this study area, which is competing for dominance of water quality in wells at each period of WCC.

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

Sequence and Time Interval in Combination of Irradiation and Cis-Diamminedichloroplatinum in C3H Mouse Fibrosarcoma (C3H 마우스 섬유육종에 있어서 방사선 조사와 Cis-diamminedichloroplatinum의 병용시 순서 및 시간간격의 영향)

  • Ha, Sung-Whan;Choi, Eun-Kyung;Park, Charn-Il
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.29-34
    • /
    • 1993
  • Experiments have been carried out with C3H mouse fibrosarcoma (FSa II) to determine the effect of different sequence and time intervals between irradiation and administration of cis-diammihedichloroplatinum (cis-DDP) with gross tumors (6 mm in diameter), microscopic tumors (3 days after transplantation of $10^3$ cells) and cells in culture. The drug was administered either 24, 12, 8, 4, 2, 1, 0.5 hour before irradiation, immediately before irradiation, or 0.5, 1, 2, 4, 8, 12, 24 hours after irradiation. In case of in vivo studies, tumor growth delay was used as an end point. Clonogenic cell surviving fraction was used for in vitro studies. Tumor growth delay for gross tumor after 10 Gy radiation plus 10 mg/kg cis-DDP ranged from 6.3 to 10.66 days and the enhancement ratio ranged from 1.37 to 2.23. The most effective combination was when cis-DDP was given 4 hours before irradiation. Tumor growth delay for microscopic tumor after 5 Gy of radiation and 5 mg/kg of cis-DDP ranged from 3.55 to 11.98 days with enhancement ratio from 2.05 to 6.92. Microscopic tumors showed response significantly greater than additive in every time interval and the most effective treatments were when cis-DDP was given 2 and 1 hour before irradiation. In in vitro experiment, the surviving fraction after 6 Gy of radiation and 1 hour exposure to 4 ${\mu}M$ cis-DDP fluctuated as a function of time between treatments, but the difference between maximum and minimum surviving fractions was very small. According to the above results the sequence and time interval between irradiation and chemotherapy is very critical especially for the management of microscopic tumors as in the case of postoperative adjuvant treatment.

  • PDF