• 제목/요약/키워드: m-factor

검색결과 8,669건 처리시간 0.039초

더미 안테나를 사용한 모노폴 안테나 보정계수 추출 (Use of Dummy Antenna to Monopole Antenna Factor)

  • 안형배;이종악
    • 한국전자파학회논문지
    • /
    • 제13권9호
    • /
    • pp.932-936
    • /
    • 2002
  • 이번 연구는 국제전자파장해특별위원회(CISPR A)에서 논의되고 있는 30 MHz 이하의 전계 세기 측정에 사용되는 1 m 모노폴 측정용 안테나의 계수를 설명하고 이를 대체하여 사용할 수 있는 더미안테나를 제작하여 측정을 하였다. 주파수 150 kHz ~ 30 MHz에 사용할 수 있는 더미 안테나를 제작하여 안테나 계수를 측정한 결과 주파수 150 kHz ~ 25 MHz에서는 양호한 결과를 얻을 수 있었다. 따라서 더미 안테나를 사용함으로써 1 m 모노폴 안테나 계수 확인을 위한 대체 측정방법으로 활용될 수 있음을 확인할 수 있었다.

Factor Rank and Its Preservers of Integer Matrices

  • Song, Seok-Zun;Kang, Kyung-Tae
    • Kyungpook Mathematical Journal
    • /
    • 제46권4호
    • /
    • pp.581-589
    • /
    • 2006
  • We characterize the linear operators which preserve the factor rank of integer matrices. That is, if $\mathcal{M}$ is the set of all $m{\times}n$ matrices with entries in the integers and min($m,n$) > 1, then a linear operator T on $\mathcal{M}$ preserves the factor rank of all matrices in $\mathcal{M}$ if and only if T has the form either T(X) = UXV for all $X{\in}\mathcal{M}$, or $m=n$ and T(X)=$UX^tV$ for all $X{\in}\mathcal{M}$, where U and V are suitable nonsingular integer matrices. Other characterizations of factor rank-preservers of integer matrices are also given.

  • PDF

구획 화재에서 스프링클러 열 손실계수 변화에 따른 작동 시간 분석 (Analysis on the Effects of the Heat Loss Coefficient on the Operation Time of Sprinkler in Compartment Fire)

  • 유우준
    • 한국화재소방학회논문지
    • /
    • 제32권5호
    • /
    • pp.34-39
    • /
    • 2018
  • 본 연구에서는 구획 공간 화재 시 발열량이 급격히 변하는 조건에서 스프링클러헤드의 손실인자 변화에 따른 작동시간을 분석하였다. 이를 위해서 내화보드로 구성된 구획 공간의 크기가 폭 0.3 m, 세로 0.5 m, 길이 3.0 m인 구조물을 제작하고 헵탄(n-Heptane) 풀 화재 실험을 수행하여 구획 공간 내부의 온도 분포, 헵탄의 질량감소율 그리고 발열량을 산출하였다. 또한, Fire Dynamics Simulator (FDS) Version 6.5를 사용하여 실험 조건과 동일한 발열량을 가정하고 스프링클러헤드의 설치위치 및 손실인자(C-factor) 변화에 따른 작동 시간을 분석하였다. 그 결과 반응시간지수(Response Time Index, RTI)가 $100(m{\cdot}s)^{0.5}$이고 작동온도가 $72^{\circ}C$인 스프링클러는 화원 상층부의 기류 온도가 $100^{\circ}C$에서 $300^{\circ}C$로 상승하고, 기류의 속도가 약 0.7 m/s인 경우 C-factor = 0과 1일 때 스프링클러의 작동시간은 최소 30 s~60 s, C-factor = 3일 때 62 s에서 최대 92 s, C-factor = 5일 때 120 s 이상으로 나타났다.

LEVEL-m SCALED CIRCULANT FACTOR MATRICES OVER THE COMPLEX NUMBER FIELD AND THE QUATERNION DIVISION ALGEBRA

  • Jiang, Zhao-Lin;Liu, San-Yang
    • Journal of applied mathematics & informatics
    • /
    • 제14권1_2호
    • /
    • pp.81-96
    • /
    • 2004
  • The level-m scaled circulant factor matrix over the complex number field is introduced. Its diagonalization and spectral decomposition and representation are discussed. An explicit formula for the entries of the inverse of a level-m scaled circulant factor matrix is presented. Finally, an algorithm for finding the inverse of such matrices over the quaternion division algebra is given.

실험 계획법을 이용한 초정밀 연마 가공에 관한 연구 (A Study on the Ultra-precision Mirror Finishing Using the System of Experiments)

  • 김홍배
    • 한국생산제조학회지
    • /
    • 제7권5호
    • /
    • pp.134-139
    • /
    • 1998
  • There have been so manu study in the ultra-precision mirror finishing. Already Using system of experiments extract factors effecting surface roughness and find optimal machining conditions in 40${\mu}{\textrm}{m}$, 30${\mu}{\textrm}{m}$, 15${\mu}{\textrm}{m}$ abrasive film. So in this study, Using Abrasive film of 12~3${\mu}{\textrm}{m}$ extract factors effecting surface roughness and results are follows; Factor A(film feed) in 12${\mu}{\textrm}{m}$ and 5${\mu}{\textrm}{m}$ abrasive film, Factor A(film feed) and B(applied force) in 9${\mu}{\textrm}{m}$ abrasive film, Factor C(grinding speed) in 3${\mu}{\textrm}{m}$ abrasive film are main factor effecting surface roughness.

  • PDF

MG-63 세포주에서 Vascular Endothelial Growth Factor (VEGF) mRNA 발현에 대한 Insulin-like Growth Factor I (IGF-I)의 효과에 대한 연구 (THE EFFECTS OF INSULIN-LIKE GROWTH FACTOR I (IGF-I) ON EXPRESSION OF VASCULAR ENDOTHELIAL GROWTH FACTOR (VEGF) MRNA IN MG-63 OSTEOBLASTLIKE CELLS)

  • 서제덕;명훈;강나라;정필훈
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권5호
    • /
    • pp.363-369
    • /
    • 2005
  • Purpose: To determine the role of Insulin-like Growth Factor-I (IGF-I) in the regulation of Vascular Endothelial Growth Factor (VEGF) expression in MG-63 cells and then to find the mechanism b which this regulation occurs. Materials and methods: MG-63 cells were grown to confluence in 60-mm dishes. To determine the effects of IGF-I on expression of VEGF mRNA according to time and concentration, the cells were treated with 10 nM IGF-I, following isolation of total RNA and Northern blot analysis after 1, 2, 4, 8, 12, 24 hours and after 2 hours of treatment with 0.5, 2, 10, 25, 50 nM IGF-I respectively, isolation of total RNA and Northern blot analysis were followed. To determine the mechanism of action of IGF-I, inhibitors such as hydroxyurea $(76.1\;{\mu}g/ml)$, actinomycin D $(2.5\;{\mu}g/ml)$, cycloheximide $(10\;{\mu}g/ml)$ were added 1 hour after treatment of 10 nM IGF-I. Results: 1. the expression of VEGF mRNA was increased with treatment of IGF-I. 2. The expression of VEGF mRNA was increased according to time-and concentration dependent manner of IGF-I. 3. The effect of IGF-I was decreased by hydroxyuera, actinomycin D, but not by cycloheximide. Conclusion: IGF-I regulate the expression of VEGF mRNA in the level of DNA synthesis and transcription. These results could suggest that IGF-I plays an important role in angiogenesis in the process of new bone formation and remodeling.

하지동작(下肢動作)에 따른 Slacks 구성요인(構成要因) 분석(分析) (An Analysis on the Constructional Factor of Slacks by Lower-Limb Movement)

  • 박영득;서영숙
    • 한국의류학회지
    • /
    • 제17권4호
    • /
    • pp.648-662
    • /
    • 1993
  • The summarized findings resulted from experiments and investigation are suggested as follows ; The analysis of measurements on the lower limb movements : For this experimentation, data was collected from three hundred and eighty female, age 19 to 23, who answered five lower limb movements(M1~M5). The statistics show that the order of the expansion ratio is gluteal area-length/knee-girth/back-line/knee-depth/thigh-depth/hip-girth, from the highest to the lowest in all movements. When comparing the correlation coefficient of the measurements, the values of the correlation coefficient of the height and the length items are very low, but those of the girth, the breadth, and the depth items are relatively high and those of the waist and the hip items are highest. For more sophisticated analysis, the factor analysis was conducted on the lower limb movements. Four factors were classified on the factor load by the "varimax rotation" method. Each movement shows the most important factor differently, as follows ; the most important factor in M1 is "the shape factor of lower limb below hip-line", that in M2 is "the cross-sectional shape factor", that in M3 is "the size factor of abdominal and loins region", and those in M4 and M5 accord with the interpretation of M3. When the investigation of the estimated function was conducted, in the selectional case of representative items on the slacks construction, it found that it would be better to add abdomen and thigh items as important considerations to waist girth, hip girth and crotch length.

  • PDF

Revisiting the virial factor with the updated $M_{BH}-{\sigma}_*$ relation

  • 박대성;우종학
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.35.1-35.1
    • /
    • 2012
  • Determining the virial factor of the broad-line region (BLR) gas is crucial in calibrating AGN black hole mass estimators, since the measured line-of-sight velocity needs to be converted into the representative velocity of the BLR gas. The unknown virial factor has been empirically calibrated based on the $M_{BH}-{\sigma}_*$ relation of non-AGN galaxies, but the claimed values are different by a factor of 2 in recent studies. We investigate the origin of the difference by measuring the $M_{BH}-{\sigma}_*$ relation using the most updated nearby galaxy sample, and explore the dependence of the virial factor on the various fitting methods. We find that the discrepancy is mostly caused by the sample bias while the difference stemming from various regression methods is marginal. Based on the best-determined virial factor, we present the updated $M_{BH}-{\sigma}_*$ relation of local active galaxies.

  • PDF

Cloning of Bovine Macrophage Colony-stimulating Factor

  • Kim, Tae-Yung;Kim, Cheol-Ho;Lee, Sang-Gil;Kang, Chung-Boo
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권6호
    • /
    • pp.892-897
    • /
    • 2005
  • Macrophage colony-stimulating factor (M-CSF) is a growth factor required for growth and differentiation of mononuclear phagocyte lineage. Total and 16 poly (A) mRNA of bovine M-CSF were isolated from healthy bovine peripheral mononuclear cells stimulated by phobol 12-myristste 13-acetate (TPA). The more compatible cultured mononuclear cells were 5${\times}$10/ml for RNA isolation. TPA-activated mononuclear cells increased the level of M-CSF-mRNA more than concanavalin A (Con A) and lipopolysaccharide (LPS). The optimal analysis of reverse transcriptase-polymerase chain reaction (RT-PCR) for14 Macrophage colonystimulating factor (M-CSF) as a growth factor required for bovine M-CSF was denaturation at 94$^{\circ}C$ for 1 minute, annealing at 57$^{\circ}C$ for 1 minute, extension at 72$^{\circ}C$ for 1 minute for 30 cycles. The size of cDNA of bovine M-CSF by RT-PCR was 774 base pairs. A 774 base pairs cDNA encoding bovine M-CSF was synthesized by reverse transcriptase polymerase chain reaction (RT-PCR). Ligated cDNA was transformed to competent cells and then plasmid isolation and digestion was performed. Molecular cloning and sequencing were performed for cDNA of bovine M-CSF. The size of cloned cDNA of bovine M-CSF was 774base pairs. The homology of base sequence and amino acid sequence was 88% and 86% compared with known human M-CSF, respectively. From a high degree of sequence similarity, the obtained cDNA of bovine M-CSF is thought be a specific gene of bovine M-CSF.

Uptake and Phytotoxicity of TNT in Onion Plant

  • Kim, Jaisoo;Yavuz Corapcioglu;Malcolm C. Drew
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.102-106
    • /
    • 2003
  • The uptake of $^{14}C$-2, 4, 6-trinitrotoluene (TNT) in hydroponics was studied using onion plants. Of the total TNT mass (5 $\mu\textrm{M}$ concentration), 75% was in the roots, 4.4% in the leaves, and 21% in the external solution at 2 days, The percent distribution in roots was lower with higher concentration in the external solution, but in leaves it was comparable at all concentrations (5-500 $\mu\textrm{M}$). Root concentration factor (RCF) in hydroponics was more than 85 in constant hydroponic experiment (CHE) at 5 $\mu\textrm{M}$ and 150 in non-constant hydroponic experiment (NHE) at 5 $\mu\textrm{M}$. The maximum RCF values in the hydroponic system were greater with lower solution concentration. Transpiration stream concentration factor (TSCF) values in the present study (NHE only: 0.31-0.56) were relatively similar to the values with predicted values (0.43-0.78), increasing with higher external TNT concentration. For phytotoxicity tested in hydroponics and wet paper method, 500 $\mu\textrm{M}$ was toxic to onion plant, 50 $\mu\textrm{M}$ was non-toxic for plant growth but limited the transpiration rate, and 5 $\mu\textrm{M}$ was non-toxic as control.

  • PDF